Mobile Radiography Course 1304 RAD 1304 Instructor: TAGELDIN ABUGROON.

Slides:



Advertisements
Similar presentations
EMERGENCY MEDICAL MANAGEMENT OF RADIATION CAUSALTIES IN HOSPITAL Module XVII.
Advertisements

Clean, Aseptic and Sterile Technique
Mobile Radiographic Equipment. Introduction In-patients who could not leave their beds In-patients who could not leave their beds Surgeons who required.
Veterinary Radiation Safety 4 Students Radiation Safety MA Law requires that persons who perform diagnostic radiology procedures on animal patients be.
Topic 3 Selection of kV High kV scattered radiation is energetic. Angle of rays is same as those of primary beam and is not deflected very much. Follows.
Disease Transmission Precautions. Standard Precautions These are applied to all __________________ at all times because not all diseases are readily observable.
Dental X-ray Machine 118 Radiology.
DESIGNING FOR RADIATION PROTECTION. TUBE HOUSING  REDUCES LEAKAGE TO LESS THAN 100 mR PER HOUR AT A DISTANCE OF ONE METER FROM HOUSING  One meter is.
CVT 102.  Time  Distance  Shielding.
Digital FLUORO Summer 2008.
Radiation Occupational exposures and protection A. H. Mehrparvar, MD Occupational Medicine department Yazd University of Medical Sciences.
Veterinary Radiology Safety and Procedures. What is a radiograph? When an xray beam (a form of electromagnetic radiation) penetrates tissue to form a.
Radiography Introduction. Objectives To describe  Properties of x-rays  Production of x-rays  Formation of radiographic image  Components of an x-ray.
Special Radiographic examination
Basic quality control tests in medical radiography
Occupational exposure and protective devices
Quality Assurance/Quality Control Chapter 10. Quality Assurance Definition A system of activities whose purpose is to provide assurance that the overall.
Fluoroscopy and Radiation Exposure
RADIATION SAFETY Phil Facey Lead Superintendent Radiographer
Industrial Radiography Basic Safety Requirements
CREATION OF AN OPTIMAL ANGIO SUITE A. CHATZIOANNOU.
Personal Radiation and Occupational Safety – CT Policy This policy is in both paper form in the lab’s compliance manual, and on a Power Point presentation.
Dental Assisting Radiology
Mosby items and derived items © 2007, 2003, 1999 by Mosby, Inc., an affiliate of Elsevier Inc. Surgical Radiography.
Introduction to Fluoroscopy & Radiation Safety
RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY
Current UK legislation and guidelines for radiation protection of patients and staff Prepared by: Dr D. Mladenova.
Chapter 3 Radiation Safety Vet Tech Institute. Radiation should be respected not Feared! Safety is Always important! Safety is Always important! Stray.
FLUOROSCOPY EQUIPMENT
ERCP Q&A.
FLUROSCOPY. What is Fluoroscopy? Fluoroscopy is a method of using low intensity X-ray beams to continuously visualize the area of interest in "real.
Radiography Testing 1 Radiography Testing (RT), or industrial radiography is a nondestructive testing (NDT) method of inspecting materials for hidden flaws.
Spot Filming Cinefluorography Fluoro Room Shielding Radiation Areas.
Northern California SGNA Meeting September 22, 2012.
ABCs of Radiation Safety Joseph D. Babb, MD FACC FSCAI Professor of Medicine East Carolina University.
Horizontal Laminar Air Flow Vertical Laminar Air Flow.
Sterile Techniques. Surgical Asepsis A. Involves keeping the clinical setting and objects as free from microorganisms as possible. B. Used in operating.
RADIATION SAFETY Mrs. Brinston. Introduction As a healthcare worker, you know that radiation is an important tool for detecting and treating diseases.
Basic radiation protection & radiobiology
Large Animal Radiography Chapter 19 Radiology. Introduction Large animal radiography requires patience and time. Radiography of large animals must be.
Radiation Sources in medicine diagnostic Radiology
©2013 Delmar, Cengage Learning. All Rights Reserved. May not be scanned, copied, duplicated, or posted to a publicly accessible website, in whole or in.
Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. Chapter 23 Extraoral Imaging.
Designing for Radiation Protection. Design Standards for Radiation Protection – Leakage Radiation.
Part No...., Module No....Lesson No
Week 2 :Radiation Protection
Fluoroscopy. Real-time imaging Most general-purpose fluoroscopy systems use TV technology, operating at 30 frames/sec May be recorded (barium swallow.
IAEA International Atomic Energy Agency General Radiography Radiation Sources in medicine diagnostic Radiology Day 7 – Lecture 1(1)
Radiation hazards Mamoun Kremli, SA AOT Basic Principles Course.
Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. 1 Extraoral Imaging.
Week 2: Radiographic Equipment
X-RAY IMAGING INTENSIFIER
فرهاد نعلینی. رادیولوژیست. دانشگاه علوم پزشکی کرمانشاه.
IAEA International Atomic Energy Agency Fluoroscopy Radiation Sources in medicine diagnostic Radiology Day 7 – Lecture 1(2)
Diagnostic Radiology II X-ray Tubes. Anode angle Anode angle defined as the angle of the target surface with respect to the central ray in the x-ray field.
AJADI ADETOLA DEPARTMENT OF VETERINARY MEDICINE AND SURGERY.
RADIATION PROTECTION 04/12/2016.
GENERAL EXPOSURE FACTORS
Pediatric Radiology By Dr. Wambani, J.S. Chief Radiologist
RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY
Factors Effecting the Production
Pediatric Fluoroscopy
Mobile Fluoroscopy Based on:
Mobile Fluoroscopy Based on:
Pediatric Fluoroscopy
Fluoroscopy Static Image Recording Systems
Pediatric Fluoroscopy
Occupational Radiation Dose Management
Fluoroscopy: Static Image Recording Systems
Mobile Fluoroscopy.
Presentation transcript:

Mobile Radiography Course 1304 RAD 1304 Instructor: TAGELDIN ABUGROON

Mobile Image intensifier (C arm)

Mobile Image intensifier Units (C arm Unit) Mobile image intensifier are designed primarily for use in any case needs screening image or immediate X-ray Visualization especially in : (A) The operation room with: 1.Orthopedic patients (for reduction & fixation of the fractured femoral neck) 2. Urinary cases (e.g. remove calculi). 3. Biliary system cases (e.g. removal gall stones). (B) The intensive care departments for : 1. Introduction of cardiac catheters. 2. Implantation of cardiac pace-maker.

Central venous Access Catheter

Peripherally Inserted Central Catheters (PICC Lines)

Placement of the Catheter

Hickman Catheter

Advantages: 1.Immediate localization & manipulation of fractures, calculi & catheters under direct vision. 2. Fewer radiographs are needed to provide the required information.( Low dose to operator & patient). 3. Reduced operation time can be achieved, which result in; (A) Less Anesthesia. (B) More efficient use of theatre operating time.

Disadvantages:  Very close control must be kept on the length of fluoroscopy which should be kept as minimum as you can to avoid accumulating dose. The method used to limit the exposure time include: 1.The use of fluoroscopic time display & alarm. 2. The used of pulsed fluoroscopy.

components of mobile image intensifier (C-arm) 1.X-ray tube with it’s collimator. 2. Image intensifier & TV camera. 3. C-arm showing rotation possible. 4. C- arm support allowing rotation. 5. Vertical column showing movement. 6. Transverse movement. 7. Control unit & HT generator. 8. Base extending forward to give stability. 9. Castors for easy movement.

components of mobile image intensifier (C-arm) 1. The tube head : ( X-ray tube & collimator) - Is mounted on the end of the of the “C” shaped arm. The X-ray tube has a dual focus,commonly: i. 0.6mm for fluoroscopy. ii. 1.2mm for radiography. - It has two collimators: 1. One to restrict the beam size to the intensifier 2. Additional one to collimate X-ray field size.

2. Image intensifier & TV camera:  They are mounted on the opposite end of the “C” arm.  The image intensifier may be 5 inch input phosphor. 3. The “C” shaped supported arm: Is mounted on a vertical column to provide: a. Considerable vertical movement. b. Rotation about the fixing to allow. i. a vertical beam. Or ii. Horizontal beam. Or iii. Angles between.

4. The vertical column: Is mounted on the mobile base. The mobile base carries: 1. The control unit (fluoroscopy factors are normally automatically control) The high tension generator ( behind the vertical column). 2. H.T generator making a counterbalance for “C” arm. All movements of the column must have secure mechanical lockers. The wheels on the base must be large to allow easy movement.

5. TV monitor trolley: A separate trolley carrying the TV monitor. 6. Power supply: 13Amp. 240 volt main. For fluoroscopy a maximum of 3mA is provided. For radiography mA with a kV range of Methods of recording the image: 1.By video-tape to record the moving image: 2. CD: Compact disc or DVD. 3. By radiography, either by the cassette holder or by sorting imaging during fluoroscopy and transfer it to the X-ray films

 Care must be taken in setting up this equipment to ensure that the x-ray tube is as far as possible from the patient to minimize the patient dose especially patient skin.  If the focus-skin distance is short the dose received by the patient will be high & the image quality will be poor which occur because of the high object-phosphor distance & enlarged image.

Exposure levels-CR Vertical PA Projection Exposure levels-CR 30 degree from vertical

Exposure patterns & levels-CR horizontal Exposure levels AP projection (Tube on Top) not recommended

Work with C arm Equipment in the Operating Room  Undertaking radiography in conditions other than the controller ones of the x-ray department has psychological effect on the radiographer especially in the operating theatre.  This work has an emergency nature, & the time factor is important. The aim usually in surgical procedures is to be as quick as is consistent with efficient, the prolonging the length of time during the patient under anesthesia will increase the patient risk, so the radiographer should be calm & fast.

Risks in Operating Theatre Risk of Importing Infection Risk of Explosion Radiation Risk

1. Risk of importing infection (Asepsis) How we can reduced this risk? A. cleaning the machine surface before and after usage by sterilized or antiseptic solution in alcohol base. B. placing a plastic cover on the places of the unit that may touch the sterilization area. 2.Risk of explosion  This risk may occurred by using ignitable anesthetic gases during exposure which sometimes produces sparks.  These sparks could be produced from the units wheels or from the electrical parts of the control panel.

How the risk of explosion can be eliminated? (A). using non- ignitable anesthesia gases. (B). special conducting wheels, which manufactured by conducting material to pass small currents from static charges directly to the theatre ground (earthing). (C). special spark-proof X-ray units and electrical plugs are used. Radiation Risk  This risk involves anyone in operating theatre. The radiation protection is the responsibility of the radiographer before starting any exposure.

How the Radiation Risk can be minimized in OR? (1).Wearing lead apron, thyroid collar, glasses, gloves and TLD, the Radiological technologist and the staff must wearing this accessories during fluoroscopy and during taking radiographs. (2) Using the inverse square law with the staff: How? i. By standing at maximum distance. ii. By standing outside from the path of radiation source. (3) Collimation the radiation beams on the required area of the patient. (4) Minimize the screening time as possible as you can. (5)Giving clear instructions to staff before any exposure is made.

Inverse square law I 1 / I 2 = ( d 2) 2 / ( d 1) 2

Lead Apron & Thyroid Shield

Lead Gloves & Goggles

Mobile Barrier Mobile Curtain Face Shield

Collimator

Special Concerns:  In many modern theatre suites it is normally that you find a special room for the x-ray equipment & for processing facilities.  The first thing that the radiographers must be concerned with, is their own personal preparation entering an aseptic controlled area. The radiographer should change clothes & wearing theatre uniform & wear (shoe cover, hair cover, mask & washing hand).  Before unit is removed from it’s store & after it is placed in the theatre, it should be tested. This procedure should be done before surgical procedure.

 The processing equipment should be switched on & tested. Adequate levels of replenisher solutions & supply of cassettes & films should be checked.  All needed accessory equipment should be available (e.g cassette holder).  Always the examination request should be checked before starting the preparation.

Any Questions