Announcements Please read Chapter 4 HW 1 is due now

Slides:



Advertisements
Similar presentations
EE369 POWER SYSTEM ANALYSIS
Advertisements

Lecture 2 Complex Power, Reactive Compensation, Three Phase Dr. Youssef A. Mobarak Department of Electrical Engineering EE 351 POWER SYSTEM ANALYSIS.
Announcements Be reading Chapters 9 and 10 HW 8 is due now.
Announcements Be reading Chapters 8 and 9
ECE 530 – Analysis Techniques for Large-Scale Electrical Systems
EE 369 POWER SYSTEM ANALYSIS
Lecture 3 Three Phase, Power System Operation Professor Tom Overbye Department of Electrical and Computer Engineering ECE 476 POWER SYSTEM ANALYSIS.
Announcements Be reading Chapter 6, also Chapter 2.4 (Network Equations). HW 5 is 2.38, 6.9, 6.18, 6.30, 6.34, 6.38; do by October 6 but does not need.
ECE 333 Renewable Energy Systems Lecture 6: Power System Operations Prof. Tom Overbye Dept. of Electrical and Computer Engineering University of Illinois.
ECE 333 Renewable Energy Systems Lecture 14: Power Flow Prof. Tom Overbye Dept. of Electrical and Computer Engineering University of Illinois at Urbana-Champaign.
BASIC ELECTRICAL TECHNOLOGY Chapter 3 - Three Phase System
ECE 333 Renewable Energy Systems Lecture 13: Per Unit, Power Flow Prof. Tom Overbye Dept. of Electrical and Computer Engineering University of Illinois.
Announcements Be reading Chapters 1 and 2 from the book
ECE 530 – Analysis Techniques for Large-Scale Electrical Systems Prof. Hao Zhu Dept. of Electrical and Computer Engineering University of Illinois at Urbana-Champaign.
Announcements Be reading Chapter 3
Chapter 12 Three-Phase Circuit Analysis
Lecture 8 Transmission Lines, Transformers, Per Unit Professor Tom Overbye Department of Electrical and Computer Engineering ECE 476 POWER SYSTEM ANALYSIS.
EET 103 Chapter 3 (Lecture 1) Three Phase System.
Lecture 5 Power System Operation, Transmission Lines Professor Tom Overbye Department of Electrical and Computer Engineering ECE 476 POWER SYSTEM ANALYSIS.
Lecture 4 Power System Operation Professor Tom Overbye Department of Electrical and Computer Engineering ECE 476 POWER SYSTEM ANALYSIS.
EE369 POWER SYSTEM ANALYSIS
ECE 476 Power System Analysis Lecture 6: Power System Operations, Transmission Line Parameters Prof. Tom Overbye Dept. of Electrical and Computer Engineering.
ECE 530 – Analysis Techniques for Large-Scale Electrical Systems
BALANCED THREE-PHASE CIRCUITS
Announcements For lectures 8 to 10 please be reading Chapter 3
Announcements Please read Chapter 3 H4 is 4.34, 4.41, 5.2, 5.7, 5.16
ECE 476 Power System Analysis Lecture 7: Transmission Line Parameters Prof. Tom Overbye Dept. of Electrical and Computer Engineering University of Illinois.
ECE 476 Power System Analysis Lecture 5:Transmission Line Parameters Prof. Tom Overbye Dept. of Electrical and Computer Engineering University of Illinois.
1 ELECTRICAL CIRCUIT ET 201  Become familiar with the operation of a three phase generator and the magnitude and phase relationship.  Be able to calculate.
Review 1. Review of Phasors Goal of phasor analysis is to simplify the analysis of constant frequency ac systems: v(t) = V max cos(  t +  v ), i(t)
Power System Fundamentals EE-317 Lecture 3 06 October 2010.
ECE 576 – Power System Dynamics and Stability Prof. Tom Overbye Dept. of Electrical and Computer Engineering University of Illinois at Urbana-Champaign.
Fundamentals of Electric Circuits Chapter 12
Announcements Please read Chapter 3; start on Chapter 6
Lecture 2 Complex Power, Reactive Compensation, Three Phase Professor Tom Overbye Department of Electrical and Computer Engineering ECE 476 POWER SYSTEM.
ECE 476 Power System Analysis Lecture 11: Ybus, Power Flow Prof. Tom Overbye Dept. of Electrical and Computer Engineering University of Illinois at Urbana-Champaign.
Announcements For lectures 9 and 10 please be reading Chapter 3
ECE 476 Power System Analysis Lecture 15: Power Flow Sensitivities, Economic Dispatch Prof. Tom Overbye Dept. of Electrical and Computer Engineering University.
ECE 476 Power System Analysis Lecture 8: Transmission Line Parameters, Transformers Prof. Tom Overbye Dept. of Electrical and Computer Engineering University.
ECE 476 Power System Analysis Review 1 Prof. Tom Overbye Dept. of Electrical and Computer Engineering University of Illinois at Urbana-Champaign
Announcements Read Chapters 8 and 9
Announcements Read Chapters 8 and 9 HW 9 quiz today
Announcements Please read Chapters 1 and 2
ECE 476 Power System Analysis Lecture 22: System Protection, Transient Stability Prof. Tom Overbye Dept. of Electrical and Computer Engineering University.
Announcements Read Chapters 10 and 11
ECE 476 Power System Analysis Lecture 14: Power Flow Prof. Tom Overbye Dept. of Electrical and Computer Engineering University of Illinois at Urbana-Champaign.
Announcements Read Chapters 11 and 12 (sections 12.1 to 12.3)
ECE 530 – Analysis Techniques for Large-Scale Electrical Systems Prof. Tom Overbye Dept. of Electrical and Computer Engineering University of Illinois.
Announcements Homework 8 is 11.19, 11.21, 11.26, 11.27, due now
ECE 476 Power System Analysis Lecture 18: LMP Markets, Symmetrical Faults and Components Prof. Tom Overbye Dept. of Electrical and Computer Engineering.
ECE 476 Power System Analysis Lecture 13: Power Flow Prof. Tom Overbye Dept. of Electrical and Computer Engineering University of Illinois at Urbana-Champaign.
Lecture 19 Fault Analysis, Grounding, Symmetrical Components Professor Tom Overbye Department of Electrical and Computer Engineering ECE 476 POWER SYSTEM.
Lecture 15 Economic Dispatch Professor Tom Overbye Department of Electrical and Computer Engineering ECE 476 POWER SYSTEM ANALYSIS.
0 Balanced 3 Phase (  ) Systems A balanced 3 phase (  ) system has three voltage sources with equal magnitude, but with an angle shift of 120  equal.
Lecture 14 Power Flow Professor Tom Overbye Department of Electrical and Computer Engineering ECE 476 POWER SYSTEM ANALYSIS.
Announcements Please read Chapter 6
Announcements Please read Chapters 1, 2,
Reading and Homework For lecture 3 please be reading Chapters 1 and 2
Announcements Please read Chapters 8 and 9
Announcements Please read Chapter 3
Announcements Homework 7 is 6.46, 6.49, 6.52, 11.19, 11.21, 11.27; due date is October 30 Potential spring courses: ECE 431 and ECE 398RES (Renewable Electric.
Announcements Please read Chapters 4 and 5
ECE 476 POWER SYSTEM ANALYSIS
ECE 476 POWER SYSTEM ANALYSIS
ECE 476 Power System Analysis
ECEN 460 Power System Operation and Control
ECE 476 POWER SYSTEM ANALYSIS
ECE 333 Green Energy Systems
Power system operation and control
ECE 476 POWER SYSTEM ANALYSIS
Presentation transcript:

ECE 476 Power System Analysis Lecture 4: Three-Phase, Power System Operations Prof. Tom Overbye Dept. of Electrical and Computer Engineering University of Illinois at Urbana-Champaign overbye@illinois.edu

Announcements Please read Chapter 4 HW 1 is due now It does not need to be turned in, but will be covered by an in-class quiz on Sept 10 San Diego Gas & Electric is on campus for the ECE Career Fair on 9/9) (ARC Gym) and then for interviews on 9/10

Three-Phase - Wye Connection There are two ways to connect 3 systems Wye (Y) Delta ()

Wye Connection Line Voltages Van Vcn Vbn Vab Vca Vbc -Vbn (α = 0 in this case) Line-to-line voltages are also balanced

Wye Connection, cont’d Define voltage/current across/through device to be phase voltage/current Define voltage/current across/through lines to be line voltage/current

Delta Connection Ica Ic Iab Ibc Ia Ib

Three-Phase Example Assume a -connected load is supplied from a 3 13.8 kV (L-L) source with Z = 10020W

Three-Phase Example, cont’d

Delta-Wye Transformation

Delta-Wye Transformation Proof

Delta-Wye Transformation, cont’d

Three Phase Transmission Line

Per Phase Analysis Per phase analysis allows analysis of balanced 3 systems with the same effort as for a single phase system Balanced 3 Theorem: For a balanced 3 system with All loads and sources Y connected No mutual Inductance between phases

Per Phase Analysis, cont’d Then All neutrals are at the same potential All phases are COMPLETELY decoupled All system values are the same sequence as sources. The sequence order we’ve been using (phase b lags phase a and phase c lags phase a) is known as “positive” sequence; later in the course we’ll discuss negative and zero sequence systems.

Per Phase Analysis Procedure To do per phase analysis Convert all  load/sources to equivalent Y’s Solve phase “a” independent of the other phases Total system power S = 3 Va Ia* If desired, phase “b” and “c” values can be determined by inspection (i.e., ±120° degree phase shifts) If necessary, go back to original circuit to determine line-line values or internal  values.

Per Phase Example Assume a 3, Y-connected generator with Van = 10 volts supplies a -connected load with Z = -j through a transmission line with impedance of j0.1 per phase. The load is also connected to a -connected generator with Va”b” = 10 through a second transmission line which also has an impedance of j0.1 per phase. Find 1. The load voltage Va’b’ 2. The total power supplied by each generator, SY and S

Per Phase Example, cont’d

Per Phase Example, cont’d

Per Phase Example, cont’d

Per Phase Example, cont’d

Power System Operations Overview Goal is to provide an intuitive feel for power system operation Emphasis will be on the impact of the transmission system Introduce basic power flow concepts through small system examples

Power System Basics All power systems have three major components: Generation, Load and Transmission/Distribution. Generation: Creates electric power. Load: Consumes electric power. Transmission/Distribution: Transmits electric power from generation to load. Lines/transformers operating at voltages above 100 kV are usually called the transmission system. The transmission system is usually networked. Lines/transformers operating at voltages below 100 kV are usually called the distribution system (radial).

Simulation of the Eastern Interconnect

Small PowerWorld Simulator Case Load with green arrows indicating amount of MW flow Note the power balance at each bus Used to control output of generator Direction of arrow is used to indicate direction of real power (MW) flow

Power Balance Constraints Power flow refers to how the power is moving through the system. At all times in the simulation the total power flowing into any bus MUST be zero! This is know as Kirchhoff’s law. And it can not be repealed or modified. Power is lost in the transmission system.

Basic Power Control Opening or closing a circuit breaker causes the power flow to instantaneously(nearly) change. No other way to directly control power flow in a transmission line. By changing generation or load, or by switching other lines, we can indirectly change this flow.

Modeling Consideration – Change is Not Really Instantaneous! The change isn’t really instantaneous because of propagation delays, which are near the speed of light; there also wave reflection issues This will be addressed more in Chapters 5 and 13 Red is the vs end, green the v2 end

Transmission Line Limits Power flow in transmission line is limited by heating considerations. Losses (I2 R) can heat up the line, causing it to sag. Each line has a limit; Simulator does not allow you to continually exceed this limit. Many utilities use winter/summer limits.

Overloaded Transmission Line

Interconnected Operation Power systems are interconnected across large distances. For example most of North America east of the Rockies is one system, with most of Texas and Quebec being major exceptions Individual utilities only own and operate a small portion of the system, which is referred to an operating area (or an area).

Operating Areas Transmission lines that join two areas are known as tie-lines. The net power out of an area is the sum of the flow on its tie-lines. The flow out of an area is equal to total gen - total load - total losses = tie-flow

Area Control Error (ACE) The area control error is the difference between the actual flow out of an area, and the scheduled flow. There is also a frequency dependent component that we’ll address in Chapter 12 Ideally the ACE should always be zero. Because the load is constantly changing, each utility must constantly change its generation to “chase” the ACE.

Automatic Generation Control Most utilities use automatic generation control (AGC) to automatically change their generation to keep their ACE close to zero. Usually the utility control center calculates ACE based upon tie-line flows; then the AGC module sends control signals out to the generators every couple seconds.

Three Bus Case on AGC Generation is automatically changed to match change in load Net tie flow is close to zero

MISO Real-Time ACE Previously individual utilities did their own ACE calculations; now we are part of MISO, which does one for the region https://www.misoenergy.org/MARKETSOPERATIONS/REALTIMEMARKETDATA/Pages/ACEChart.aspx

MISO Real-Time ACE MISO's real-time ACE is available online (along with lots of other data) https://www.misoenergy.org/MARKETSOPERATIONS/REALTIMEMARKETDATA/Pages/ACEChart.aspx