Accurate gamma-ray spectrometry of environmental samples: a challenge O. Sima - Bucharest University D. Arnold - PTB Braunschweig C. Dovlete - ERL Bucharest.

Slides:



Advertisements
Similar presentations
Stefan Roesler SC-RP/CERN on behalf of the CERN-SLAC RP Collaboration
Advertisements

Advanced GAmma Tracking Array
Activity measurement of phosphorus-32 in the presence of pure beta-emitting impurities The CSIR Research and Innovation Conference National Metrology Laboratory.
1 Low-Dose Dual-Energy CT for PET Attenuation Correction with Statistical Sinogram Restoration Joonki Noh, Jeffrey A. Fessler EECS Department, The University.
Radiation Detection and Measurement, JU, First Semester, (Saed Dababneh). 1 Radioactivity HW 7 How can the element 106 (seaborgium) in general.
Evaluation the relative emission probabilities for 56 Co and 66 Ga Yu Weixiang Lu Hanlin Huang Xiaolong China Nuclear Data Center China Institute of Atomic.
Analysis and Results 3.Gamma-ray Spectra of 134 Cs The background subtracted spectra of 605 keV and 796 keV in multiple hit events, and their coincidence.
Accelerator Physics, JU, First Semester, (Saed Dababneh). 1 Principles of Spectrometry.
Radioactivity – review of laboratory results For presentation on May 2, 2008 by Dr. Brian Davies, WIU Physics Dept.
Introduction Radioactive nuclei decay in numerous ways: emitting electrons, protons, neutrons, alpha particles, gamma rays, x-rays, or some combination.
GAMMA RAY SPECTROSCOPY
Radioactivity – inverse square law, absorption, and rates presentation for Apr. 30, 2008 by Dr. Brian Davies, WIU Physics Dept.
Qualitative, quantitative analysis and “standardless” analysis NON DESTRUCTIVE CHEMICAL ANALYSIS Notes by: Dr Ivan Gržetić, professor University of Belgrade.
Planar X-ray Imaging Measure the integeral of the linear attenuation coefficient over the beam path through the object. has two main contributions 1.Photoelectric.
Lecture 2-Building a Detector George K. Parks Space Sciences Laboratory UC Berkeley, Berkeley, CA.
Compton Scattering Reporter: Hui He. Outline Theory Experimental setup Experimental results (1) Calibration (2) Angular Distribution of the 137 Cs Source.
Planar scintigraphy produces two-dimensional images of three dimensional objects. It is handicapped by the superposition of active and nonactive layers.
Gamma Spectroscopy HPT TVAN Technical Training
Types of Analyses Single Collector –Uses only one collector or detector –This is the case with a Daly or EM Advantages: –Need only one detector –Peaks.
Gamma ray spectrum, its acquiring and analysis
Joint IAEA-ICTP Workshop on Nuclear Reaction Data for Advanced Reactor Technologies Student’s presentation Calculation of correction factors for neutron.
Korea Hydro & Nuclear Power Company Seulki Kim
Rob Hewitt, Robyn Reist, Jason Sadowski Engineering Physics College of Engineering Student Paper Presentation Competition March 26, 2009 Supervisors: Mike.
Assement of radionuclide concentration in various samples by gamma spectrometry and LSC J. Berzins, D.Riekstina, O. Veveris Institute of Solid State Physics.
Radiation Detection and Measurement, JU, First Semester, (Saed Dababneh). 1 Spectrum if all energy is captured in detector. Allows identification.
Decay Data in View of Complex Applications Octavian Sima Physics Department, University of Bucharest Decay Data Evaluation Project Workshop May 12 – 14,
Gamma-ray efficiency of a HPGe detector as a function of energy and geometry of energy and geometry Mohsen B. Challan Physics Department, Faculty of Education.
1 Lecture 5 Overview on the Analytical Procedures (  ) Lecture 5 Overview on the Analytical Procedures (  ) Moncef Benmansour Moncef Benmansour CNESTEN,
INTRODUCTION TO ANALYTICAL CHEMISTRY ERT 207 ANALYTICAL CHEMISTRY SEMESTER 1, ACADEMIC SESSION 2015/16.
R. Kass/W03P416/Lecture 7 1 Lecture 7 Some Advanced Topics using Propagation of Errors and Least Squares Fitting Error on the mean (review from Lecture.
DDEP 2012 | C. Bisch – Study of beta shape spectra 1 Study of the shape of  spectra Development of a Si spectrometer for measurement of  spectra 
Geant4 Event Biasing Marc Verderi, LLR (Heavily copied from Jane Tinslay, SLAC) June 2007.
Measurements and calculations of the neutron spectrum in different irradiation channels of the TRIGA Mark II reactor, Slovenia R. Jaćimović 1, A. Trkov.
Octavian Sima Physics Department Bucharest University
Luis Avila Isabelle Vu Trieu Intensive General Chemistry Uncertainty Analysis Wet Techniques.
Duncan Weathers Department of Physics University of North Texas.
Accelerator Physics, JU, First Semester, (Saed Dababneh). 1 Principles of Spectrometry.
1 Scale Detection in Geothermal Systems The use of nuclear monitoring techniques E. Stamatakis a,b, T. Bjørnstad b, C. Chatzichristos b, J. Muller b and.
G4GeneralParticleSource Class: Developed by ESA as the space radiation environment is often quite complex in energy and angular distribution, and requires.
Stellenbosch University
Increase in Photon Collection from a YAP:Ce Matrix Coupled to Wave Lenght Shifting Fibres N. Belcari a, A. Del Guerra a, A. Vaiano a, C. Damiani b, G.
Determination of activity of 51 Cr source on gamma radiation measurements V.V.Gorbachev, V.N.Gavrin, T.V.Ibragimova, A.V.Kalikhov, Yu.M.Malyshkin,A.A.Shikhin.
Accelerator Physics, JU, First Semester, (Saed Dababneh). 1 In the figure: Photoelectric suppressed. Single Compton (effect of crystal dimensions).
Simulation of HPGe detector efficiency Eunkyung Lee Ewha Womans University.
Radiopharmaceutical Production Radionuclidic identity STOP.
Summer Student Practice, 2007, JINR Dubna 1 Corelative Gamma Spectroscopy of Neutron-Nucleus Interactions Using the COCOS Setup Students: Jan Žemlička,
Considerations on the possibility of Phase Contrast Mammography using ICS sources B. Golosio a, P. Delogu b, I. Zanette b, M. Carpinelli a, G. L. Masala.
PET Imaging Positron Emission Tomography
Simulations in Medical Physics Y. TOUFIQUE*, R.CHERKAOUI EL MOURSLI*, M.KACI**, G.AMOROS**, *Université Mohammed V –Agdal, Faculté des Sciences de Rabat,
Calculation of efficiency for a high-resolution gamma-ray spectrometer used for environmental radioactivity measurements Ileana Radulescu, Marian Romeo.
Monte Carlo methods in spallation experiments Defense of the phD thesis Mitja Majerle “Phasotron” and “Energy Plus Transmutation” setups (schematic drawings)
Fast neutron flux measurement in CJPL
Preliminary data analysis on 16x16 modules
M.I. Abbas - Alexandria University - EGYPT.
Radioactivity – review of laboratory results
Solving Systems of Linear Equations: Iterative Methods
The Interplay Between the Statistical Correlations of g-ray Emission Probabilities and Efficiency Calibration * Ruy M. Castro 1,2, Vito R. Vanin 3, Paulo.
Gamma spectrometric measurements of uranium isotopic composition:
Sr-84 0n EC/b+ decay search with SrCl2 crystal
Chapter 1: The Nature of Analytical Chemistry
An-Najah National University Research Day in Theoretical and Applied Physics    "Measurement of Natural Radioactivity in Some Granite Samples : Prelimenary.
Unfolding performance Data - Monte Carlo comparison
G4GeneralParticleSource Class:
Recent check of calibration across detectors
Korea Hydro & Nuclear Power Company Seulki Kim
Log-log graph of the exponential exp(-x)
Uranium enrichment measurement in UF6 cylinders by HRGS : an evaluation of the measurement uncertainty Jean-Luc DUFOUR, Nicolas PEPIN, Clément DEYGLUN,
Radiopharmaceutical Production
Radioactivity – review of laboratory results
Uncertainty Propagation
Presentation transcript:

Accurate gamma-ray spectrometry of environmental samples: a challenge O. Sima - Bucharest University D. Arnold - PTB Braunschweig C. Dovlete - ERL Bucharest

Accurate gamma-ray spectrometry of environmental samples: a challenge Introduction Problems in efficiency calibration of the spectrometer Coincidence summing effects Matrix effects Geometry effects GESPECOR Summary and conclusions

Introduction Assessment of radioactivity of environmental samples: –carefully designed sampling procedures –appropriate sample preparation –accurate sample measurement –rigorous analysis of the results Modern requirements and conditions: –low detection limits –accurate evaluation of uncertainty –high number of samples, various types, matrices, available quantities –high efficiency detectors available

Problems in efficiency calibration Low level activity + low detection limit: –high efficiency measurement conditions –volume sources Detection efficiency for volumic samples: –dependent upon sample matrix and density => Direct experimental calibration: - limited number of matrices - specific nuclides - expensive, problems with the management of radioactive material => Additional procedures for a complete calibration required Detection efficiency for high efficiency measurements: –nuclide specific coincidence summing effects

Coincidence summing effects Are encountered in the case of measurement of nuclides which decay through the emission of coincident radiation (cascading photons, X-rays, annihilation photons etc) Depend on the details of the decay scheme: –Nuclide and peak specific effects Are much enhanced in high efficiency measurement conditions Effects: –summing out (coincidence losses from the peak) => decrease of the apparent efficiency –summing in (additional counts in the sum peak) => increase of the apparent efficiency

SPECTRUM OF 22 Na (WELL-TYPE DETECTOR)

Coincidence summing: - sample analysis - efficiency calibration: ex: 1 l Marinelli beaker Co-60 => 1173 keV 0.926, 1332 keV Y-88 => 898 keV 0.932, 1836 keV ex: Well-type detector: Co-60 => 1173 keV 0.445, 1332 keV Y-88 => 898 keV 0.472, 1836 keV => Accurate procedures for the evaluation of the effects required

Matrix effects Matrix effects are encountered when the calibration source has a different composition and density than the sample of interest Depend on: –sample geometry –linear attenuation coefficient –photon energy –detector parameters Linear attenuation coefficient obtained from: –sample composition and density; –transmission experiments

- Transmission factor approximated by exp(-  d) ?

Transmission factors (log scale). Sample: R=3.5, H=2 cm Linear attenuation coefficient (1/cm) exp(-  d)

Relative error  (%). Soil sample, R=3.5 cm, H=2 cm. Energy (keV)

Geometry effects For samples measured close to the end cap of a closed end coaxial detector efficiency very sensitive to geometry details For some samples (e.g. powder) it is difficult to assure exactly the standard geometry Detectors parameters may vary in time (e.g. the entrance window of the end cap)

Relative error of activity  (A) (%). Soil sample, R=3.5 cm Energy (keV)

GESPECOR Monte Carlo based software dedicated to solve problems in gamma spectrometry: - computation of coincidence summing corrections - computation of self-attenuation effects (matrix effects) - computation of the efficiency Typical applications: environmental spectrometry - detectors: HPGe (closed end or well-type), Ge(Li) - sources: cylinder, Marinelli, point, parallelepiped, ring - matrix: any (known composition) or known  - nuclides: ~ 100 (for coincidence summing effects) Extension for very large samples: variance reduction techniques (focused photon emission, weighted emission point)

Direct efficiency calibration: - typical sources (cylinder, Marinelli, point sources) - special geometries: Parallelepiped (Al-26 in meteorite samples) Spherical source (Rn-222 sources) In situ measurements Drum waste containers Efficiency transfer – less sensitive to detector details

Summary and conclusions Accurate assessment of the radioactivity of environmental samples – a challenge –Coincidence summing effects –Matrix effects –Geometry effects The GESPECOR software can solve typical problems required by an accurate assessment of the radioactivity of environmental samples