Analog Discovery Arbitrary Function Generator for Windows 7 by Mr

Slides:



Advertisements
Similar presentations
Velleman Arbitrary Function Generator: Windows 7 by Mr. David Fritz
Advertisements

1 1 Mechanical Design and Production Dept, Faculty of Engineering, Zagazig University, Egypt. Mechanical Design and Production Dept, Faculty of Engineering,
Installing the MATLAB Add-On
Velleman Oscilloscope: Windows 7 by Mr. David Fritz
© 2002 QxDesign, Inc. Building a PI controller This unit discusses Installation of Visual ModelQ The Visual ModelQ default model Placing and configuring.
X-Call Version V3.0 User Guide
Sweeping a Variable Resistor Wheatstone Bridge. Place the Parts 1.VDC 2.R, which you place 3 times. The numbering of the resistor increases sequentially.
Introduction to Multisim ECE 1020 Professor Ahmadi.
LogTag Training January 2015
Introduction to the Oscilloscope Professor Ahmadi ECE 002.
DAP-1520 FAQ’s Wireless AC750 Dual Band Range Extender.
Introduction to electronics lab ENGRI 1810 Using: Solderless prototype board (white board) Digital multimeter (DMM) Power Supply Signal Generator Oscilloscope.
X-Call Version 2.0 user guide A manual to explain how to identify arrived patients and call into a preferred location. A manual to explain.
Analog Discovery Oscilloscope for Windows 7 by Mr. David Fritz and Ms. Ellen Robertson Financial support to develop this tutorial was provided by the Bradley.
1 Alan Rux Electrical and Computer Engineering Department University of Massachusetts Lowell Campus Lecture 1 of 4 Analog Discovery Design Kit Analog Discovery.
Experiment 11: An Inverting Amplifier
Experiments 8 and 9. Same Circuit: Experiment 8 and 9 You should use the +5 V and +9 V supplies on the ANDY board. You should use red wire to bring the.
1 Alan Rux Electrical and Computer Engineering Department University of Massachusetts Lowell Campus Analog Discovery Design Kit Analog Discovery Design.
Tabor Electronics Ltd. Hands-on Training - ArbConnection By Moti Glazer.
1 EE 188L Lab #2 Test Bench Photos. 2 Vout R1 R5 R4 R3 R C2 C1 R7 R6 At this end there will be a cut-out and/or a dot next to pin 1 -15V.
1 Lab Equipment. 2 TopicSlides DC Power Supply3-4 Digital Multimeter5-8 Function Generator9-12 Scope – basic controls13-20 Scope – cursors21-24 Scope.
MEASUREMENT DEVICES OUTLINE Multimeters Analog Multimeters
Using the Unity 98 Cordless Response System Directions : Courtesy of IHC public relations.
1 AC Measurements Using the Oscilloscope and Multimeter by Mr. David Fritz.
Magnitude and Phase Measurements
Pulse Width Modulation (PWM) LED Dimmer Circuit
 Distortion – the alteration of the original shape of a waveform.  Function of distortion analyzer: measuring the extent of distortion (the o/p differs.
Purpose Learn how to use basic electronic equipment:
Dr. Hoganson CSIS HC11 Demo Program This is our first lab using the 68HC11 microcontroller. We will “talk” to the microcontroller from a PC, run.
1 QED In Vivo USB Input Output Box configuration This tutorial contains a number of instructions embedded in a great deal of explanation. Procedures that.
Week 9: Series RC Circuit Experiment 14. Circuit to be constructed Shunt resistor It is good practice to short the unused pin on the trimpot when using.
The Function Generator and the Oscilloscope Dr. Len Trombetta 1 ECE 2100.
DWR-113 FAQ’s 3G WiFi Router.
Week 7: Design a Logarithmic Voltmeter A variation on Experiment 19 Validation by 8pm on October 14.
Experiment 12 Non-Inverting Amplifier. Experimental Procedure Clarification in Step 3 (Modeling) – To perform the DC Sweep in the sinusoidal voltage source.
TRANSMILLE PATs The New Alternative To Fast, Easy & Efficient Portable Appliance Testing.
TA: Chris Reilly Group 5: Benjamin, Ramie, Zachary, Dinal.
CH 6 Configuring Server Hardware and power options.
Basic Pspice Instructions Stuart Tewksbury
Velleman Oscilloscope: Windows XP by Mr. David Fritz.
Designing Interface Components. Components Navigation components - the user uses these components to give instructions. Input – Components that are used.
1 © 2006 Cisco Systems, Inc. All rights reserved.Cisco ConfidentialPresentation_ID Scientific Atlanta Configuration Module 2.3.
Experiment 21 Design a Traffic Arrow.
Vadodara Institute of Engineering kotanbi Active learning Assignment on Single phase AC CIRCUIT SUBMITTED BY: 1) Bhatiya gaurang.(13ELEE558) 2)
Physics 2225: Working With Electronic Equipment Purpose  Learn how to use basic electronic equipment: Digital multi meter Oscilloscope Function generator.
© 2007 Ideal Industries 1 of 32 Intro To Ideal 800 Power Analyzer Basics of IDEAL Industries 800 Series Power Analyzer.
Introduction to the Oscilloscope Professor Ahmadi ECE 002.
Week 1: Preparing for PSpice Simulations.  Week 1 is composed of two experiments from the lab manual ◦ Experiment 1: Breadboard Basics ◦ Experiment 3:
Due DateWeek Experiment in Lab ManualTitle Pre-Lab Report Validation Post- Validation Report 3/13/20123/14/20123/17/20126To be distributedMake-up Lab for.
ADS – APPLICATION IN FILTER DESIGN
Velleman Oscilloscope: Windows 7 by Mr. David Fritz.
Installation instructions for the Digilent Analog Discovery software interface By Ellen Robertson Financial support to develop this tutorial was provided.
Phasors and Kirchhoff’s Current Law
Important! Be sure to connect the communication cable to your computer before opening the Aqua4Plus Lite software. (Click to continue)
Wheatstone Bridge. Schematic of a Wheatstone Bridge V BA = 0V and I R3 = I R4 if R 1 = R 2 and R 3 = R 4. Typically, the resistors are selected such that.
BASIC INSTRUMENTS - oscilloscopes
Week 3: Experiment 4 Kirchhoff’s Laws.
Lego Mindstorm Robots 9797 kit.  Students will learn how to identify how to detect a change in a condition.  Students will learn where and how to identify.
The Function Generator and the Oscilloscope Dr. Len Trombetta and Dr. Dave Shattuck 1 ECE 2100.
Transient Response. Transient Analysis Plot of the voltages or currents as a function of time. – Output plot mimics the oscilloscope display. If simulating.
Making a 24hr Timer.
The first change to your project files that is needed is to change the device to the correct FPGA. This is done by going to the Assignments tab on the.
Week 9: Series RC Circuit
fischertechnik® RoboPro Software for Gateway To Technology® RoboPro
Crossover Distortion Hands-on Experiment TIPL 4101-L TI Precision Labs – ADCs Hello and welcome to the TI Precision labs hands-on experiment on crossover.
McCrometer Nano Board Test Procedure
Oscilloscopes HP 54600B Digital Oscilloscope Alex Jones COE 0501.
Exporting Data from the Analog Discovery to Excel
2019 Investing Now Summer Program
Presentation transcript:

Analog Discovery Arbitrary Function Generator for Windows 7 by Mr Analog Discovery Arbitrary Function Generator for Windows 7 by Mr. David Fritz and Ms. Ellen Robertson Financial support to develop this tutorial was provided by the Bradley Department of Electrical and Computer Engineering. Virginia Tech and the National Science Foundation [Award # 0817102, Lab-in-a-Box: Development of Materials to Support Independent Experimentation on Concepts from Circuits and Electronics]

Starting the Analog Discovery Install the Waveforms software from the Digilent Incorporated website. Attach the Analog Discovery to one of the USB ports on your computer. The device drivers will install automatically. Launch the Waveforms software Start -> Programs -> Digilent -> WaveForms (You will probably want to make a shortcut) Note: When closing, the WaveForms software stores the last configuration, if set to do so. To make sure that you have the factory default settings (even if somebody previously saved a different WaveForms configuration on your computer), click “Options” in the WaveForms main window, then “Erase configuration” in the Options window. Close the Options window. D. Fritz and E. Robertson

What if the software doesn’t find the Analog Discovery? You may see a pop-up that states that you are in Demo mode because the software did not find the scope. Click OK to use Demo mode. Check to make sure that you plugged the Analog Discovery into one of your computer’s USB ports. Next, click on Demo on the Device Manager window that pops up, then click Select. D. Fritz and E. Robertson

Connect to the Analog Discovery Click > Device Manager >Digilent Discovery > Select A red LED will light up inside the case of the Analog Discovery when the scope is attached, powered on, and is ready to use. Each Analog Discovery has its own unique Serial Number. If “Digilent Discovery” does not appear in the list, uninstall and reinstall the WaveForms software. D. Fritz and E. Robertson

Cables The Analog Discovery comes with a wire assembly with 30 wires, which plug into the connector on the side of the black case. The individual wires can be inserted into a header with sets of male pins, which can then be plugged into the breadboard. The output signals from the arbitrary function generator can be wired from the correct pin on the header to the appropriate point in the circuit. D. Fritz and E. Robertson Header with 6 pins

Output Pins for the Arbitrary Function Generator The outputs of the function generators are marked W1 and W2. Looking at the Analog Discovery in the photo to the left, these are the fifth (5th) wires from the bottom on the connector. W1 is located along the upper row of connector (pin 5 - yellow wire) W2 is located along the bottom row of the connector (pin 20 - yellow wire with white marking). D. Fritz and E. Robertson

Complete Pin-Out for Analog Discovery D. Fritz and E. Robertson Image provided by Digilent, Inc.

Arbitrary Function Generator Calibration The calibration of Arbitrary Waveform Generator (AWG) can be initiated through the Device Manager, which can be launched from the main Waveforms control window. In Device Manager, click on the words Show Advanced Features D. Fritz and E. Robertson

Run Calibration Click on Calibrate and then double click on the row for AWG 1 or 2 from the drop down menu that appears. Given that many of the experiments require both function generators, it is best to calibrate both AWG 1 and AWG 2 each time you launch the Analog Discovery Wave Generator. D. Fritz and E. Robertson

Launch the Arbitrary Waveform Generator Go back to the main control window. Click on the button. This will cause a new window to open immediately. Or, click on the arrow to the left of this button and select Open New. D. Fritz and E. Robertson

Select one or both arbitrary waveform generators, Channel 1 (AWG 1) and Channel 2 (AWG 2), and set the parameters of operation. Note that AWG 1 corresponds to output W1 and AWG 2 to output WG2. D. Fritz and E. Robertson

Signal Generator built into the Analog Discovery Wave Gen generates sine, square, and triangle waveforms, plus other functions. Select the waveform type with the buttons. Select Frequency, Amplitude, and DC offset ranges with the menus, then adjust the actual value with the slider or type the values into the boxes. Similarly, you can select the Symmetry and Phase, which will be covered in another lecture. The generator output (automatically graphed on the right) is set for a 1000Hz, 10Vpp sine wave with a 0 V DC offset. D. Fritz and E. Robertson

Maximum and Minimum Menus You can select the maximum and minimum allowable frequencies, amplitudes, dc offset, symmetry of the signal shape, and phase angle with respect to a reference signal. When you click on the arrow next to the words Max and Min, you can select the maximum (or minimum) values for the slider for the particular parameter in the specific box. In this case, 10 kHz has been selected as the maximum frequency that can be set using the slider for the frequency of operation of the sinusoidal signal. You can also type in a value for the maximum and minimum frequencies into the boxes next to the words Max and Min. So, you could type 10 kHz into the box that currently has 50 kHz displayed instead of using the drop-down menu. Values not listed in the drop-down menu can be entered this way. D. Fritz and E. Robertson

Actual Value Menu To set the value of the frequency of the sine wave that will be outputted by the Arbitrary Waveform Generator: The slider can be moved to the desired frequency. The value will be displayed in the box below Frequency . Or, a value between the Min and Max values can be typed into the box below Frequency . If the value is larger than the Max or smaller than the Min values, then the Max or Min value will be displayed instead. Or, select a value from the drop- down menu available by clicking on the arrow. The range of values listed in the drop- down menu is determined by the size of the Max-Min range. In this example, 6 kHz and 8 kHz have been typed into the boxes next to the words Min and Max as the range for the Frequency of the Sine wave. D. Fritz and E. Robertson

Other Settings For the first experiments, leave the default settings for the other parameters – Trig (None), Wait (none), and Run (continuous) in the left-hand side of the controls for the Arbitrary Waveform Generator and Components (Auto scale) on the right-hand side. Also, keep the Offset at 0V, the Symmetry at 50% and Phase at 0 deg. There are instructions on how to use the other settings for the Arbitrary Waveform Generator in the Advanced_AWG presentation. D. Fritz and E. Robertson

Next? To start and stop the function generator output, Toggle the Run AWG 1 button or the Run All button. The latter will turn on AWG 2 also if both channels were selected. Connect pin 5 (W1) to the circuit to apply power to the node. Connect one of the grounds to complete the circuit (black wires - pin 3, 6, 18, or 21) Make your DC current and voltage measurements using the DMM. Make your voltage measurements as a function of time using the oscilloscope. D. Fritz and E. Robertson

Fixed DC Outputs The Analog Discovery can also output a constant DC signal of +5V and/or -5V. Click on the Voltage icon . Click the toggle buttons on the window that opens. +5V is applied to pin 4 on the connector, the red wire, when Power is ON and VP+ ON -5V is applied to pin 19 on the connector, the white wire, when Power is ON and VP- ON. VP+ and VP- may be turned on simultaneously. D. Fritz and E. Robertson

DC Output To generate a DC output from the Digilent Analog Discovery, make a sine wave with a 0V amplitude and then use the offset to move the signal to the DC voltage needed (3 V in this example). Note that the graphical display of the output for AWG 1 is a straight line equal to 3 V. D. Fritz and E. Robertson

Enabling the Waveform Generator The default for the Arbitrary Waveform Generators is Disabled, which means that there is no signal being outputted from the Analog Discovery to W1 pin for AWG 1. The setting must be changed to Enabled so that the signal that has been set using the control window is available on pin 5 (W1) for AWG 1 [or pin 20 (W2) for AWG 2]. Click on the word Disabled to toggle the Waveform Generator to Enabled. The default idle output is the initial value of the sine wave. In this case, the output of the AWG 1 was set to 2 V sin[7 kHz (t)] + 1.5 V. Since t = 0 s, the initial value is the offset voltage (1.5 V), which is the signal that is now the signal available on pin 4. This is another way to obtain a DC output using the Arbitrary Waveform Generator. D. Fritz and E. Robertson