BDS Magnet-Power System-Facility Optimization1 ILC BDS Kickoff Meeting Basis for Magnet, Power System and Cooling Facility Optimization Discussion Paul.

Slides:



Advertisements
Similar presentations
Nov. 17, 2008 ILC08 Global Design Effort 1 Americas KlyCluster Cost Analysis Overview Tom Lackowski RF & Sum reported by Peter H. Garbincius.
Advertisements

11/27/2007ILC Power and Cooling VM Workshop Mike Neubauer 1 RF Power and Cooling Requirements Overview from “Main Linac Power and Cooling Information”
Nov. 07 DR-KOM-CFS 1 Damping Rings KOM Conventional Facility & Siting Overview Tom Lackowski Acknowledgment: Atsushi Enomoto, Jean-Luc Baldy, John Osborne,
9/17/07 ILC Detectors 1 Conventional Utilities Tom Lackowski.
Global Design Effort - CFS TILC09 and GDE AAP Review Meeting - Tsukuba, Japan 1 GDE ACCELERATOR ADVISORY PANEL REVIEW CONVENTIONAL FACILITIES.
Oct 24, 2007 C.Spencer Magnet EDR Planning 1 GDE Generating Magnet Work Packages: Planning for the Engineering Design Phase Cherrill Spencer, SLAC with.
Nov. 19, 2008 ILC08 Global Design Effort 1 Status Report Alternative Siting and Tunnel Design Tom Lackowski.
November 17, 2008 ILC08 HVAC and VE Update November 17, 2008 ILC CFS Workshop 2008 Chicago Lee Hammond, Fermilab Global Design Effort.
44 th Annual Conference & Technical Exhibition By Thomas Hartman, P.E. The Hartman Company Georgetown, Texas Sustainable Chilled Water.
UTSW Thermal Energy Plants, Power Generation and Electrical System What do we do to meet the Emission Reduction, Energy usage Reduction and Electrical.
CONVENTIONAL ELECTRICAL TDR DESIGN Randy Wielgos March 22, 2012 ILC CFS Baseline Technical Review.
3/2011 CFS BTR Global Design Effort 1 Americas Region Civil Design Tom Lackowski.
1 ILC Mechanical & Electrical Review Conventional MECHANICAL System Design Summary Emil Huedem, FNAL Lee Hammond, FNAL Parsons Mechanical Team (Tim Sheehan,
Global Design Effort - CFS Baseline Assessment Workshop 2 - SLAC Reduced Bunch Number 1 BASELINE ASSESSMENT WORKSHOP 2 CONVENTIONAL FACILITIES.
1 HVAC OVERVIEW and VALUE ENGINEERING ITEMS August 13, 2008 CLIC Working Group CES Lee Hammond, Fermilab.
Value Engineering Session Air Treatment / HVAC November 27, 2007 Lee Hammond, FNAL CFS.
Central Region Discussion Power and Cooling GDE Beijing-CFS.
INTRODUCTION to the DESIGN and FABRICATION of IRON- DOMINATED ACCELERATOR MAGNETS Cherrill Spencer, Magnet Engineer HOMEWORK PROBLEM for Lecture # 2 of.
Powering the main linac implications Daniel Siemaszko, Serge Pittet OUTLINE : Cost impact of power converters, power consumption and powering.
Global Design Effort 1 Conventional Facilities and Siting Overview A. Enomoto, J-L. Baldy, V. Kuchler GDE.
E Huedem, Nov ILC VALUE ENGINEERING SESSION of POWER & COOLING (Focus on Main Shaft 7) November 27, 2007 INFORMATION PHASE Conventional.
1 Process Water and Air Treatment 01 June 2007 Emil Huedem, Maurice Ball, Lee Hammond Fermilab.
ILC Energy Efficiency Marc Ross and Ewan Paterson, SLAC CFS-ADI Joint Meeting ICEPP University of Tokyo 9 April 2014 Three examples: 1) higher quality.
LCC Linear Collider Collaboratio ILC - CFS 12 November 2013 LCWS13 Tokyo University 1 Site-specific CF design from TDR LCWS13, 12 November 2013 Atsushi.
Global Design Effort - CFS ILC CFS and Global Systems Meeting 1 ILC CFS AND GLOBAL SYSTEMS MEETING CONVENTIONAL FACILITIES AND SITING GROUP GENERAL.
Global Design Effort - CFS Baseline Assessment Workshop 2 - SLAC Positron Source Relocation 1 BASELINE ASSESSMENT WORKSHOP 2 CONVENTIONAL FACILITIES.
Global Design Effort - CFS LCWS CONVENTIONAL FACILITIES AND SITING GROUP Parallel Session Overview A. Enomoto, V. Kuchler, J. Osborne.
Fred Asiri1 Conventional Facilities and Siting Global Group (CFS) SLAC Update Conventional Facilities and Siting Global Group (CFS) SLAC Update November.
November 2004 Low Hanging Fruit Low Cost Energy Efficiency Opportunities in Cleanrooms.
BDS Pulsed Magnets RDR Completeness BDS EDR Kickoff Meeting SLAC October 2007 Thomas Mattison University of British Columbia.
Global Design Effort Beam Delivery System => EDR LCWS07 June 2, 2007 at DESY Andrei Seryi for BDS Area leaders Deepa Angal-Kalinin, A.S., Hitoshi Yamamoto.
19 July 2006 Vancouver Global Design Effort 1 Cryogenic Systems Review Tom Peterson for the cryogenics global group.
SLAC_OCT07 BDS-KOM-CFS 1 Beam Delivery System & Interaction Region KOM Conventional Facility & Siting Overview Fred Asiri/SLAC Acknowledgment: Atsushi.
Global Design Effort1 September 20-22, 2006 MAC Review Power and Water breakout (mixed results) Marc Ross GDE.
ILC BDS Kickoff Meeting Magnet Power Supplies RDR Concepts and Completeness Paul Bellomo SLAC Power Conversion Department October, 2007.
1 HVAC OVERVIEW for Single Tunnel Configuration November 17, 2008 ILC CFS Workshop 2008 Chicago, IL Lee Hammond, Fermilab.
Fermilab February 1, 2007 J. Tompkins -1- Comments on the EDR and Magnet Systems JCT for the Magnet Systems Group
Global Design Effort - CFS Accelerator Advisory Panel Review - Oxford UK 1 ACCELERATOR ADVISORY PANEL REVIEW CONVENTIONAL FACILITIES AND SITING.
Aug 23, 2006 Half Current Option: Impact on Linac Cost Chris Adolphsen With input from Mike Neubauer, Chris Nantista and Tom Peterson.
Global Design Effort - CFS TILC08 Working Group 1 - March 5, CFS Cost Reductions Conventional Facilities and Siting Group A. Enomoto, V.
BDS: 1 October 13, 2007 BDS KOM EDR planning discussion Andrei Seryi October 13, 2007.
Global Design Effort - CFS Damping Ring Baseline Technical Review 1 DAMPING RING BASELINE TECHNICAL REVIEW CONVENTIONAL FACILITIES AND SITING.
1 V. Kashikhin for ILC ALCPG 2007, FNAL Meeting October 23, 2007 Ring to Main Linac Magnets.
Global Design Effort Working Group C Conventional Facilities Parallel Session IRENG07 V. Kuchler, A. Enomoto, J. Osborne September 19, 2007.
Global Design Effort - CFS DESY Accelerator Design and Integration Meeting 1 ACCELERATOR INTEGRATION AND DESIGN MEETING CONVENTIONAL FACILITIES.
October 25, 2007 A. Brachmann Slide 1 ILC polarized Electron Source EDR Work Packages ALCPG/GDE Meeting Fermilab, October 25, 2007 Axel Brachmann.
ILC Cryogenic Systems Status and EDR Plans Tom Peterson 25 October 2007.
August 11, 2011 FNAL Meeting Global Design Effort 1 DR-CFS Discussion Mark Palmer GDE.
Global Design Effort - CFS ILC Source/RTML/BDS + MDI Technical Baseline Review October ILC SOURCES/RTML/BDS + MDI TECHNICAL BASELINE.
ATF2 Magnets ATF2 Magnets 14 Sep 2007Cherrill Spencer, SLAC. Cooling Solid Wire Sextupoles 1 Report of the effort to cool an old FFTB solid wire sextupole.
Global Design Effort - CFS ILC CFS and Global Systems Meeting 1 ILC CFS AND GLOBAL SYSTEMS MEETING CONVENTIONAL FACILITIES AND SITING GROUP CFS.
Fred Asiri1 Conventional Facilities and Siting Global Group (CFS) SLAC Update Conventional Facilities and Siting Global Group (CFS) SLAC Update December.
August 2007Andrea Gaddi, CERN Physics Dept. Detectors Infrastructures & Services Baseline to design detectors infrastructures. Tentative arrangement of.
1 CFS Utilities – What’s included in RDR for IR July CFS Utilities – IRENG WG C WATER COOLING: none. Unknown loads on IR. Only have water plants.
E Huedem, June RDR PROCESS WATER & VALUE ENGINEERING ITEMS June 5, 2008 GDE Meeting-ILC CFS Workshop in Dubna, Russia Emil Huedem, Fermilab.
CFS EDR KICK OFF MEETING Air Treatment August 23, 2007 Lee Hammond, FNAL CFS.
E- source kick-off meeting e- Source RDR- Conventional Facility & Siting Overview Fred Asiri/SLAC.
CBETA Technical Review
Conventional Facility & Siting (CF&S) Overview for the Positron Source
CFS EDR KICK OFF MEETING Process Water August 23, 2007
Americas KlyCluster Cost Analysis Overview
ILC RTML Meeting EDR Planning for Magnet Power Systems
Calculating Heat Loads of Normal Conducting ILC Magnets
BDS Cryogenic System RDR Status and EDR Plans
DR Magnets & Power Supply System ILC-ADI Meeting March 14, 2012
COOLING & VENTILATION INFRASTRUCTURE
Conventional Facilities and Siting Global Group (CFS) SLAC Update December 10, 2007 Acknowledgment: Jerry Aarons, Clay Corvin, and Esther Kweon Fred Asiri.
ILC Cryogenic Systems Draft EDR Plan
Extract from today’s talk given to DCB
ILC Cryogenics -- Technical Design Report Planning
Presentation transcript:

BDS Magnet-Power System-Facility Optimization1 ILC BDS Kickoff Meeting Basis for Magnet, Power System and Cooling Facility Optimization Discussion Paul Bellomo and Cherrill Spencer - SLAC Emil Huedem, Lee Hammond, Tom Lackowski and John Tompkins – FNAL October, 2007

BDS Magnet-Power System-Facility Optimization2 October, Topics Scope is cooling infrastructure, magnets, and magnet PS operating at 1TeV as conceived for the RDR Overview cooling infrastructure and assumptions Overview of magnet quantity and power systems Overview of magnet and power system losses Discuss RDR completeness regarding losses EDR areas for potential loss reductions, tradeoffs and cost optimization SLAC PCD EDR Expression of Interest pertaining to magnet power system design and optimization

BDS Magnet-Power System-Facility Optimization3 October, Cooling System Overview BDS Cooling infrastructure concept and cost scaled from Main Linac Plant, except the BDS Dump near surface distribution, which was cost estimated separately. Main Linac process water uses 20F temp rise. The same is assumed for the BDS. There are two basic water cooling infrastructure system, the chilled water and the process water (which includes LCW). The LCW supply temperature is 95F. The air system used same as ML. No details, - didn’t consider multiple tunnels in BDS/KAS area. Still need to layout/conceptualize LCW?, establish other heat load components in service tunnel, get updated loads, firm up environmental criteria. See next diagram for more description

BDS Magnet-Power System-Facility Optimization4 Cooling Towers 85F Process Water Heat Exchangers (BDS Cavern ) 90F Process Water LCW Skid 95F LCW Chiller ~48F Chilled Water “?” Quantities Chilled Water Fan Coil Process Water Fan Coil To Magnets To Power Supplies BDS RDR Simplified Process Water Concept (Not shown: CFS Cooling for BDS Dumps) Service Tunnel BeamTunnel 78F Wet Bulb RDR BDS Cooling Infrastructure October, 2007

BDS Magnet-Power System-Facility Optimization5 Chiller “?” Quantities Chilled Water Fan Coil Process Water Fan Coil To Magnets To Power Supplies RDR % of BDS Process Water Cost Service Tunnel BeamTunnel RDR BDS Cooling Cost Distribution CHW 16% NonLCW 19+% Dump Infra 25% LCW 28% Others 11+% Procs 47+% October, 2007

BDS Magnet-Power System-Facility Optimization6October, Overview of RDR Power System Quantities and Types Rollup as of December individually powered magnets, 276 magnets on strings

BDS Magnet-Power System-Facility Optimization7 October, Overview of RDR Power Systems Small or Intermediate, rack- mounted, unipolar or bipolar power supply, powers an individual, normal temperature magnet Power supplies are distributed in service tunnels adjacent to beamline. Cable runs are relatively short

BDS Magnet-Power System-Facility Optimization8 October, Overview of RDR Power System Losses Water flow based on 1TeV losses and 18 O F rise in water LCW water 95 O F in, 115 O F out, maximum Beam tunnel ambient 100 O F to 105 O F Service tunnel ambient 80 O F to 85 O F

BDS Magnet-Power System-Facility Optimization9 October, Overview of RDR Power System Losses E- or e+ Common Service TunnelE- or e+ Common Beam Tunnel Length = 866m PS loss to air+50% cable loss=182.5kW 50% cable loss to air = 46.5kW Heat Loading = 212W/m Heat Loading = 53W/m E- or e+ 14mr Service TunnelE- or e+ 14mr Beam Tunnel Length = 1,360m PS loss to air+50% cable loss=273.5kW 50% cable loss to air = 99.5kW Heat Loading = 201W/m Heat Loading = 73W/m

BDS Magnet-Power System-Facility Optimization10 October, RDR Completeness Estimate BDS Cooling infrastructure concept and cost was scaled from Main Linac Plant, except for the BDS Dump near surface distribution, which was cost estimated separately. Main Linac process water use 20F temp rise. The same is assumed for the BDS. Cooling infrastructure is conceptual, and very little on paper. The only loads used for costing was the total kW load for 1 TeV dated Sep 06, adjusted for 1 IR. Cost was completed in November 2006 Still need to layout/conceptualize LCW?, establish other heat load components in service tunnel, get updated loads, firm up environmental criteria. All power system designs conceptual, very little is on paper. Written specifications, building/equipment layouts, rack profiles, wiring diagrams, cable tray or raceway layouts do not exist Accurate estimate of losses and their distributions cannot be made until layouts and equipment profiles are made Environmental and facility Project specifications needed for design are not available

BDS Magnet-Power System-Facility Optimization11 October, EDR Areas of Potential Optimization BDS has 53,700m of cable. This is the smallest amount of cable in all the ILC areas 23,000m of this cable is larger than 500kcmil in size. These are candidates for water cooled cable. Changing from air-cooled to water-cooled cable will have the following implications:  Smaller diameter, and in the cases of paralleled cable, less cable is needed. Although this has the potential for a smaller, less expensive cable tray system, the cable itself will be more expensive on a per meter basis, but possibly less expensive overall.  The replacement of larger, air-cooled, copper cable with smaller, water-cooled (possibly aluminum) cable will cause an increase in power losses. Detailed deigns are needed  Even with the larger cable losses, the losses will be re-directed from the building cooling system to the cooling water system  The next slide tabulates the loss transfer from air to water for the large cables.

BDS Magnet-Power System-Facility Optimization12 October, EDR Areas of Potential Future Optimization Here are the cable losses that could be transferred from air to water. This table does not take into account the possible increase in cable loss from smaller water-cooled cables and thus underestimates the new water heat load Area Present Cable Loss to Air (kW) New Water Losses from Air Cooled Cable (kW) New Cable Loss to Air (kW) E- Common E+ Common E- 14mr E+ 14mr Total

BDS Magnet-Power System-Facility Optimization13 October, EDR Areas of Potential Optimization Load to Chilled Water Assumed 50% to service tunnel (Chilled Water), and 50% to beam tunnel (process water via fancoil) Load to Process Water Adjusted from Nov 2006 load assumptions Reduction in CHW load by ~200kW, BUT how much reduction in net cost? Increase in Process/LCW load by ~200kW, BUT how much increase in net cost?

BDS Magnet-Power System-Facility Optimization14 October, EDR Areas of Potential Optimization The magnet – power supply/cable interface is another optimization area. If the magnet currents are lowered, since cable losses go as I 2, for a given cable size the cable losses are reduced. This would reduce heat loading and the facility plant. It might also be possible to reduce the size of the cable and reduce cable tray system costs. Stringing more magnets will reduce cable and raceway costs, cable loss heat loading and reduce power system (less power supplies and controls) costs

BDS Magnet-Power System-Facility Optimization15 October, Last Slide – EDR EOI The SLAC Power Conversion Department (PCD) prepared an Expression of Interest (EOI) proposal for design and engineering of pulsed and DC magnet power systems. Expect design effort involving electrical engineer, control engineer (hardware) and layout designers to achieve the EDR goals. The EDR EOI includes an estimate of the interdisciplinary effort to optimize the tradeoffs between cable costs, raceway costs and facility costs.