Lecture #11 EGR 272 – Circuit Theory II

Slides:



Advertisements
Similar presentations
EE369 POWER SYSTEM ANALYSIS
Advertisements

Presentation : IMS – Tech Managers ConferenceAuthor : IMS StaffCreation date : 08 March 2012Classification : D3Conservation :Page : ‹#› 10 – Three Phase.
Lecture 2 Complex Power, Reactive Compensation, Three Phase Dr. Youssef A. Mobarak Department of Electrical Engineering EE 351 POWER SYSTEM ANALYSIS.
Lecture #12 EGR 272 – Circuit Theory II
Announcements Be reading Chapters 8 and 9
Chapter 24 Three-Phase Systems.
Chapter 12 Three Phase Circuits
ENERGY CONVERSION ONE (Course 25741)
BASIC ELECTRICAL TECHNOLOGY Chapter 3 - Three Phase System
ECE 4411 Introduction to Three-Phase Power. ECE 4412 Typical Transformer Yard.
CHAPTER 11 Balanced Three - Phase Circuits. CHAPTER CONTENTS 11.1 Balanced Three-Phase Voltages 11.1 Balanced Three-Phase Voltages 11.2 Three-Phase Voltage.
Balanced Three-Phase Circuits
Lesson 33 AC Generators.
Lecture 101 EEE 302 Electrical Networks II Dr. Keith E. Holbert Summer 2001.
Lesson 34 3 PHASE Sources & Loads. Learning Objectives Review the induced AC voltage output for a three phase AC generator as a function of time and as.
Announcements Be reading Chapter 3
1 ECE 3336 Introduction to Circuits & Electronics Set #16 Transformers Fall 2012, TUE&TH 4:00-5:30 pm Dr. Wanda Wosik.
Chapter 12 Three Phase Circuits
Chapter 12 Three-Phase Circuit Analysis
Chapter 7 Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
Three-Phase ac Voltage Generation
Three-Phase circuits Prof. Siripong Potisuk. Faraday’s Law “The EMF induced in a circuit is directly proportional to the time rate of change of magnetic.
EET 103 Chapter 3 (Lecture 1) Three Phase System.
THREE PHASE CIRCUIT.
Assessment Questions 1-8. Generating electric current Electric current creates a magnetic field LT #2: Demonstrate and explain that an electric current.
Chemical, Biological and Environmental Engineering Generating Electricity.
Balanced 3-phase systems Unbalanced 3-phase systems
Line and Phase Voltages for a Wye Circuit.
Engineering Circuit Analysis
Circuits II EE221 Unit 12 Instructor: Kevin D. Donohue
Chapter 1 : Three Phase System.
Three – Phase Power System. Three-Phase Power Definitions 4 wires –3 “active” phases, A, B, C –1 “ground”, or “neutral” Color Code –Phase ARed –Phase.
AC Generators (Alternators)
1 ECE 3336 Introduction to Circuits & Electronics Set #16 Transformers Fall 2011, TUE&TH 4-5:30 pm Dr. Wanda Wosik.
BALANCED THREE-PHASE CIRCUITS
EMLAB Polyphase circuits. EMLAB 2 1. Three Phase Circuits Advantages of polyphase circuits 2. Three Phase Connections Basic configurations for three.
© The McGraw-Hill Companies, Inc McGraw-Hill 1 PRINCIPLES AND APPLICATIONS OF ELECTRICAL ENGINEERING THIRD EDITION G I O R G I O R I Z Z O N I 7.
Branch : Computer Engineering
Alexander-Sadiku Fundamentals of Electric Circuits
1 ELECTRICAL CIRCUIT ET 201  Become familiar with the operation of a three phase generator and the magnitude and phase relationship.  Be able to calculate.
Power System Fundamentals EE 317 Lecture 7 20 October 2010.
Review 1. Review of Phasors Goal of phasor analysis is to simplify the analysis of constant frequency ac systems: v(t) = V max cos(  t +  v ), i(t)
Fundamentals of Electric Circuits Chapter 12
Guided by: Sudhir pandey
EKT103 ELECTRICAL ENGINEERING
Three-Phase System 1 by Dr Rosemizi Abd Rahim Click here to watch the three phase animation video
Motors and Generators.
Announcements Please read Chapters 1 and 2
ELECTRICAL TECHNOLOGY (EET 103) PN HAZIAH ABDUL HAMID.
Copyright ©2011, ©2008, ©2005 by Pearson Education, Inc. Upper Saddle River, New Jersey All rights reserved. Electric Circuits, Ninth Edition James.
EKT103 ELECTRICAL ENGINEERING
FUNDAMENTALS OF ELECTRICAL ENGINEERING [ ENT 163 ]
MUZAIDI BIN MARZUKI PPKSE.
EKT103 ELECTRICAL ENGINEERING Chapter 1 Three-Phase System Dr. Rosemizi Abdul Rahim Dr. Amir Razif Arief Jamil Abdullah ( ) Dr. Junita Mohd Nordin.
CHAPTER 4: THREE-PHASE CIRCUIT
1 Eeng 224 Chapter 12 Three Phase Circuits Huseyin Bilgekul Eeng224 Circuit Theory II Department of Electrical and Electronic Engineering Eastern Mediterranean.
ELECTRIC CIRCUITS EIGHTH EDITION JAMES W. NILSSON & SUSAN A. RIEDEL.
ET 332b Ac Motors, Generators and Power Systems 1 Lesson 11_et332b.pptx.
Lesson 31: Three Phase Sources and Loads
Chapter 12 Three Phase Circuits
BASIC ELECTRICAL TECHNOLOGY Chapter 3 - Three Phase System
POLYPHASE CIRCUITS Three Phase Circuits
DKT213 ELECTRICAL TECHNOLOGY
POLYPHASE CIRCUITS Three Phase Circuits
Electrical Engineering Principle DNT 235/3
ELL100: INTRODUCTION TO ELECTRICAL ENGG.
Three Phase Circuits Chapter Objectives:
Lecture 10 - Transformers/Three-Phase Circuits
BALANCE THREE PHASE SYSTEM
Presentation transcript:

Lecture #11 EGR 272 – Circuit Theory II Read: Chapter 11 in Electric Circuits, 6th Edition by Nilsson Chapter 11 - Three Phase (3) Circuits So far we have only considered single phase (1) circuits. Transmission of power Power is transmitted using AC since voltage levels are easily stepped up for transmission and down for customers through the use of transformers. As voltage increases, current decreases, so line losses (I2R losses) are reduced. AC voltages are generated using 3 phase voltages (three voltages that are separated in phase by 120°). Businesses and industry commonly use 3 phase voltages. The 3 phases are split up so that a residential neighborhood uses only one of the 3 phases. A single phase voltage of 240V is provided to a house along with 120V formed using a center tap transformer (illustrate below).

Lecture #11 EGR 272 – Circuit Theory II Advantages of 3-phase circuits: more efficient (smaller I2R losses) less vibration in machinery smaller conductors Polyphase circuits AC voltages can be generated using various numbers of phases. 3 phase is the most common 6 and 12 phase are sometimes seen

Lecture #11 EGR 272 – Circuit Theory II Single-phase (1  ) and 3-phase (3 ) generators 3- phase generator Single-phase generator (3 sets of windings on the rotor, where each are physically staggered by 120º) + V - (one set of windings on the rotor) + Van - + Vbn - + Vcn - Generator coil representation Generator coil representation + V - + Van - + Vbn - + Vcn - Waveforms (abc phase sequence) : Waveform t V t Van Vbn Vcn

Lecture #11 EGR 272 – Circuit Theory II TCC Engineering students touring the Dominion Virginia Power Nuclear Power Station in Surry, VA One of the 800 MW 3-phase steam turbine generators is shown on the right. Nuclear energy is used to heat water and create steam to power the generators.

Lecture #11 EGR 272 – Circuit Theory II TCC Engineering students touring the Dominion Virginia Power Nuclear Power Station in Surry, VA Huge transformers are used to increase the voltage to 500,000 V before it leaves the power plant. Increases the voltage reduces the current, resulting in lower line losses (I2R) during transmission.

Lecture #11 EGR 272 – Circuit Theory II Three small transformers are mounted on the wall in the old electronics lab (Lynnhaven Building, Room 144). Each transformer carries a separate phase. The outputs of the transformers were used for 3-phase experiments.

Lecture #11 EGR 272 – Circuit Theory II 3 transformers on a pole carry 3-phase power along Indian River Road in Virginia Beach 1 transformer on a pole carries 1 single phase into a nearby neighborhood in Virginia Beach

Lecture #11 EGR 272 – Circuit Theory II Phase sequences The three phases may be arranged in two possible phase sequences: 1) abc (or positive) phase sequence 2) acb (or negative) phase sequence t Van Vbn Vcn t Van Vcn Vbn

Lecture #11 EGR 272 – Circuit Theory II Phase sequences The two possible phase sequences are sometimes represented by phasor diagrams as shown below. Note: A practical illustration of the effect of phase sequence is that if a 3 motor is connected with an abc phase sequence it will turn in one direction and if it is connected with an acb phase sequence it will turn in the other direction.

Lecture #11 EGR 272 – Circuit Theory II Generator Connections There are two basic types of generator connections: Wye (Y) generator Delta () generator

Lecture #11 EGR 272 – Circuit Theory II The wye and delta generators shown on the previous page might also be represented using voltage sources, as shown in the PSPICE schematics below. Wye Generator Delta Generator

Lecture #11 EGR 272 – Circuit Theory II Balanced versus unbalanced generators Balanced generators have the same magnitude for each phase and exactly 120o of phase shift between each phase. Systems with balanced generators are easier to analyze. Example: For each case shown below, is the generator balanced? What is the phase sequence? Circle the correct responses.

Lecture #11 EGR 272 – Circuit Theory II 3 Y generator Define the line voltages Vab , Vbc , and Vca . Show how to calculate line voltages in general using KVL. Show that for a balanced Y generator:

Lecture #11 EGR 272 – Circuit Theory II 3  generator Show that the line voltages are equal to the generator phase voltages. In general, for a Y generator:

Lecture #11 EGR 272 – Circuit Theory II Load connections There are two common ways to connect the three phase loads: 1) Wye (Y) connection 2) Delta (D) connection Wye (Y) Load: Note: A wye load is balanced if ZAN = ZBN = ZCN. Discussion: When would loads be balanced?

Lecture #11 EGR 272 – Circuit Theory II Delta Load: Note: A delta load is balanced if ZAB = ZBC = ZCA.

3-Phase Generator Load Lecture #11 EGR 272 – Circuit Theory II Generator-load configurations There are several possible generator and load configurations, including: 1) Y-Y a) 4-wire b) 3-wire 2) Y-D 3) D -D 4) D -Y 3-Phase Generator Load 4-wire Y-Y system Y-Generator Y-Load

Lecture #11 EGR 272 – Circuit Theory II Example: A 4-wire Y-Y system has a balanced generator with Van = 480 V and a positive phase sequence.

Lecture #11 EGR 272 – Circuit Theory II Y- D system: Note that the Y- D system is significantly more difficult to analyze that the Y-Y system.

Lecture #11 EGR 272 – Circuit Theory II Example: Determine all three line currents in a Y -  system that has a balanced generator with Van = 240 V and a negative phase sequence.