Australia-Italy Australia 6, October 2005 LCGT project Kazuaki Kuroda LCGT Collaboration Cryogenics for LCGT.

Slides:



Advertisements
Similar presentations
9 th /July/2013 Amaldi 10 C3 15:24~15:42 N.KIMURA/KEK Progress on the Cryogenic System for the Interferometric Cryogenic Gravitational Wave Telescope,
Advertisements

ET-meeting, 22 th Oct N. KIMURA/KEK The Latest Status of the KAGRA Cryogenics N. KIMURA A, D. CHEN B, T. KUME A, S. KOIKE A, Y. SAKAKIBARA B, T.
11 Kazuhiro Yamamoto Institute for Cosmic Ray Research The university of Tokyo Current status (Experiments in Toshiba, Susupension model, Sapphire fibers,
April 27th, 2006 Paola Puppo – INFN Roma ILIAS Cryogenic payloads and cooling systems (towards a third generation interferometer) part II: the Vibration.
Australia-Italy Australia 4, October 2005 LCGT project Kazuaki Kuroda LCGT Collaboration.
1st ET General meeting, Pisa, November 2008 The ET sensitivity curve with ‘conventional‘ techniques Stefan Hild and Andreas Freise University of Birmingham.
Dublin/July'04 1 BLTS interferometers: Big, Low-temperature Transparent Silicon Interferometers Warren Johnson Louisiana State University LIGO-G Z.
11 K. Yamamoto, R. Takahashi, T. Sekiguchi, Y. Sakakibara, C. Tokoku, M. Kamiizumi, U. Iwasaki, T. Uchiyama, S. Miyoki, M. Ohashi, T. Akutsu A, H. Ishizaki.
Cryogenics for LCGT Technical Advisory Committee for LCGT ICRR SUZUKI, Toshikazu High Energy Accelerator Research Organization.
Status of LCGT and CLIO Masatake Ohashi (ICRR, The University of TOKYO) and LCGT, CLIO collaborators TAUP2007 Sendai, Japan 2007/9/12.
Design study for ET 3rd generation Gravitational Wave Interferometer Work Package 2 Suspension, Thermal noise and Cryogenics Piero Rapagnani
LCGT Cryogenics Status Report KEK T.Suzuki.
ICRR Seminar 2009/07/24 Cryogenics in CLIO Masatake Ohashi and the LCGT collaboration.
T Akutsu 1, S Telada 2, T Uchiyama 1, S Miyoki 1, K Yamamoto 1, M Ohashi 1, K Kuroda 1, N Kanda 3 and CLIO Collaboration. 1 ICRR, Univ. of Tokyo, 2 AIST,
111 K. Yamamoto, R. Takahashi, T. Sekiguchi, Y. Sakakibara, C. Tokoku, M. Kamiizumi, U. Iwasaki, E. Hirose, T. Uchiyama, S. Miyoki, M. Ohashi, T. Akutsu.
R&D activities in Florence Geppo Cagnoli INFN and U. of Glasgow WG2 & WG3 Meeting – 27 th Apr Firenze.
A new facility for thermal conductivity measurements Filippo Martelli Univ. of Urbino and INFN Florence GWADW 2006 – 27/5-02/ – La Biodola.
1 Kazuhiro Yamamoto Institute for Cosmic Ray Research (ICRR) the University of Tokyo ELiTES first collaboration meeting Sanjo conference hall, the University.
11111 K. Yamamoto, R. Takahashi A, H. Tanaka, T. Miyamoto, K. Ono, T. Sekiguchi, Y. Sakakibara, M. Kamiizumi, E. Hirose, A. Khalaidovski, R. Kumar, T.
[A proposal for ILIAS NEXT: Cryogenics versus vibration] [I3-FP7 call] Abstract The reduction of thermal noise in solids is a basic requirement in many.
1 Kazuhiro Yamamoto Institute for Cosmic Ray Research (ICRR) the University of Tokyo KAGRA face to face meeting Institute for Cosmic Ray Research, Kashiwa,
Simulation for KAGRA cryogenic payload: vibration via heat links and thermal noise Univ. Tokyo, D1 Takanori Sekiguchi.
Flat-Top Beam Profile Cavity Prototype
1 Kazuhiro Yamamoto Institute for Cosmic Ray Research, the University of Tokyo Cryogenic mirrors: the state of the art in interferometeric gravitational.
1 K. Yamamoto, R. Takahashi, T. Sekiguchi, T. Uchiyama, H. Ishizaki A, A. Takamori B, R. DeSalvo C, E. Majorana D, LCGT collaboration ICRR, NAO A,ERI B,
LCGT Technical Review Suspension Point Interferometer for Parasitic Noise Reduction and an Additional IFO S.Miyoki (ICRR, Univ. of TOKYO)
External forces from heat links in cryogenic suspensions D1, ICRR, Univ. Tokyo Takanori Sekiguchi GWADW in Hawaii.
Status of the Japanese Projects Kazuaki Kuroda TAMA/CLIO/LCGT Collaboration ICRR, University of Tokyo LSC-Virgo Meeting 26 July, 2007 G R.
Virgo-Material “macro” group M.Punturo. VIRGO-MAT2 VIRGO-MAT components Virgo-MAT is composed by three INFN groups –Firenze/Urbino M.Lorenzini, G.Losurdo,
Large-scale Cryogenic Gravitational- wave Telescope, LCGT Keiko Kokeyama University of Birmingham 23 rd July 2010 Friday Science.
1 Kazuhiro Yamamoto Max-Planck-Institut fuer Gravitationsphysik (Albert-Einstein-Institut) Institut fuer Gravitationsphysik, Leibniz Universitaet Hannover.
Thermoelastic dissipation in inhomogeneous media: loss measurements and thermal noise in coated test masses Sheila Rowan, Marty Fejer and LSC Coating collaboration.
11 K. Yamamoto and KAGRA collaboration Institute for Cosmic Ray Research the University of Tokyo Current status of KAGRA Cryogenic 16 May 2012 Gravitational-Wave.
1 Kazuhiro Yamamoto Institute for Cosmic Ray Research The university of Tokyo Report from sub-groups Cryogenic Cryogenic payload 4 August 2011.
ACIGA High Optical Power Test Facility
Cryogenic Payload Issues
2009/6/25Amaldi 8 in NewYork City1 Thermal-noise-limited underground interferometer CLIO Kazuhiro Agatsuma and CLIO Collaborators Institute for Cosmic.
LCGT f2f meeting/ICRR, 04/Aug./2011 N. KIMURA Status of the Cryogenics Design N. KIMURA A, S. KOIKE B, T. KUME B, T. OHMORI D, Y. SAITO C, Y. SAKAKIBARA.
External forces from heat links in cryogenic suspensions D1, ICRR, Univ. Tokyo Takanori Sekiguchi.
Defining the volumes and functions of the cryogenic suspension Discussion guidance Kashiwa October JGW-G
111 Kazuhiro Yamamoto Institute for Cosmic Ray Research, the University of Tokyo Cryogenic interferometer technologies 19 May 2014 Gravitational Wave Advanced.
1 Kazuhiro Yamamoto Institute for Cosmic Ray Research The University of Tokyo KAGRA external review (Cryogenic payload) 18 April 2012.
GWADW2011 Elba/Italy, 23/May/2011 N. KIMURA and Y. SAKAKIBARA Present Design of LCGT Cryogenic Payload - Status of Cryogenic Design - N. KIMURA*, Y. SAKAKIBARA**,
1 Kazuhiro Yamamoto Institute for Cosmic Ray Research The university of Tokyo LCGT internal review (Cryogenic payload) 30 January 2012.
11 Kazuhiro Yamamoto Institute for Cosmic Ray Research The university of Tokyo Current status (Toshiba, ELiTES, Baffle, Brittleness of Maraging, Cryogenic.
1 Cryogenic payload is not a simple system. We need cryostat to test cryogenic payload performance. 1/4 cryostat will be prepared in Kashiwa campus. 1/4.
Measurement of coating mechanical loss Junko Katayama, K.Craig, K.Yamamoto, M.Ohashi ICRR 0.
1 Kazuhiro Yamamoto Institute for Cosmic Ray Research The university of Tokyo LCGT internal review (Cryogenic payload) 30 January 2012.
Lessons from CLIO Masatake Ohashi (ICRR, The University of TOKYO) and CLIO collaborators GWADW2012 Hawaii 2012/5/16.
Status of the cryogenic payload system for baseline KAGRA Rahul Kumar 1, K. Craig 2, K. Yamamoto 2, H. Tanaka 2, T. Miyamoto 2,T. Kajita 2, T. Suzuki 1,
Overview of iLCGT & bLCGT Kazuaki Kuroda LCGT Collaboration F2f meeting 27 September, 2010.
Vibration measurements at KAGRA site
Cryogenic development in KAGRA
Performance test of KAGRA cryostat at site
Overview of the 20K configuration
New suspension study for LCGT
Michele Punturo WP3 meeting, Cascina 9-July-2004
Pros and cons of cryogenics for Einstein Telescope and Cosmic Explorer
Performance test of KAGRA cryostat at site
Kazuaki Kuroda On behalf of LCGT Collaboration
Vibration measurements at KAGRA site
External forces from heat links in cryogenic suspensions
Flat-Top Beam Profile Cavity Prototype: design and preliminary tests
New suspension study for LCGT
Flat-Top Beam Profile Cavity Prototype
Development of vibration isolation systems for LCGT VII
Development of vibration isolation systems for LCGT VI
Development of vibration isolation systems for LCGT VI
CLIO underground in mine
The ET sensitivity curve with ‘conventional‘ techniques
Presentation transcript:

Australia-Italy Australia 6, October 2005 LCGT project Kazuaki Kuroda LCGT Collaboration Cryogenics for LCGT

Brief summary of Cryogenics of LCGT

SPI sub-mirror SAS: three stages with inverted pendulum Main mirror Heat links extend from here to the inner shield heat anchor. Suspension system Outer shield of cryostat Vacuum is common Sapphire fiber suspending mirror

Configuration of LCGT cryostat. Two sets of towers corresponds to one arm FP cavity. Drawn by Toshiba

Why do we choose cryogenics? Because it is the simplest way to reduce thermal noise

Thermal noise reduction at cryogenic temperature beam radius 3cm To improve by one order in room temperature. Radius -> 4.6times ( ) -> 14cm Figure is prepared by Uchiyama Adv. LIOG adopts Mexican hut shaped beam profile. We take a way to cool it down.

By Yamamoto

Basic experiments of cryogenic mirror and its R&D

We need sapphire in place of fused silica at cryogenic temperature. Typical samples were produced by CSI is given by the author, which was found to be too small.

Heat extraction experiment in Hemlite sapphire cylinder. Sapphire fiber Reverse setup protects the break of fibers Springs constantly raise the rod. Liquid Helium cryostat. A heater is attached here.

A heater simulates the optical loss in the sapphire substrate. Since the thermal conductivity was high, the temperature distribution was uniform (the calibration error of thermometers was larger). Fibers are 250 micron in diameter, with c- axis along the fiber. The above shows the time response of the temperature.

We have conducted cryogenic experiments to confirm the feasibility of cryogenic mirror by sapphire. Q measurement The fundamental and the second lowest mode were measured. They were higher than 10 8.

Experimental setup In

Suspension prototype was tested in Kashiwa campus in ICRR, in m Fabry-Perot Cavity was formed.

(Miyoki et al.) Although we succeeded in the operation in cryogenic temperature, the mechanical vibration of the refrigerator was clearly introduced to the test mass. Quiet refrigerator and softer heat Link are required.

Quiet refrigerator was developed ( design in 2003) F-6: Class. Quantum Grav. (Accepted), Pr-1: Proc. 28th ICRC (2003), patent: Pa-3 Tomaru et al., 2003; Suzuki et al., Switching box Pulse tube ref. 1 st & 2 nd stages To compressor 4K cold head 40K cold stage Soft heat links

Vibration of Cold Head Without reducing the efficiency, the vibration of Cold Stage, Cold Head have been reduced by more than 2 〜 3orders of magnitude. Measured underground of Kamioka mine Not the vibration of the refrigerator But the fixing device of the meter Cold head vibration is less than the seimic noise level of the Underground of Kmioka mine.

We used the measurement of Yamamoto’s optical coating loss. He directly measured Q of thin disk coated and its mechanical loss was evaluated. By Yamamoto

Design of Cryogenic suspension

Effort to increase the optical quality of sapphire

Sapphire quality was checked by an automatic birefringence measurement device Tokunari et al. in Poster session

Practical advancement of cryogenic mirror

Main mirrors of CLIO were polished by Canon Co. Ltd. And now in the process of coating by JAE.

Conclusion of this Talk Cryogenic interferometer, LCGT, is realized by sapphire whose mechanical quality is good but its optical quality is not sufficient. Basic and practical techniques of a cryogenic interferometer have been developed. We are trying to increase the quality of sapphire to increase the sensitivity of LCGT. Practical test is now undergoing by CLIO interferometer at Kamioka.