EFFECT OF HARMONICS ON DISTRIBUTED GENERATION

Slides:



Advertisements
Similar presentations
POWER FACTOR IN ELECTRICAL ENERGY MANAGEMENT
Advertisements

Siemens Building Technologies Building Technologies Variable Frequency Drives Harmonics Overview.
ECE Electric Drives Topic 6: Voltage-Fed Converters Spring 2004.
Chapter 4 DC to AC Conversion (INVERTER)
EMC in Electrical Power Systems Frithiof Jensen Power System Engineer November 12, 2013.
Effects of high penetration levels of photovoltaic generation Observations from field data Amir Toliyat, Alexis Kwasinski and Fabian Uriarte The University.
ISSBN, Electronic faculty of Niš, November Use of distortion power for side identification of the harmonic polution Dejan Stevanović, Electronic.
Power Systems 2002 Conference Impact of Distributed Generation Clemson, SC March 13-15, 2002 PANEL DISCUSSION P6 Experience with Testing DG Chairman: Ben.
Campus da FEUP Rua Dr. Roberto Frias, Porto Portugal T F © 2009 Decentralised Energy Systems.
Chapter 4 DC to AC Conversion (INVERTER)
Why Take Electrical Engineering?
ECE 333 Renewable Energy Systems Lecture 13: Per Unit, Power Flow Prof. Tom Overbye Dept. of Electrical and Computer Engineering University of Illinois.
Announcements Be reading Chapter 3
Chapter 8 Inverters AC Power • Inverters • Power Conditioning Units • Inverter Features and Specifications.
POWER SUPPILES LECTURE 20.
Tennesse Technological University
Household Electricity
 Our energy efficient house is located in Los Angeles, California.  The 3 energy reducing features in our home are solar panels, Energy Star light bulbs,
1 A. Lipsky, N. Miteva, E. Lokshin Department of Electrical and Electronic Engineering Ariel University Center of Samaria Israel Electric Power Quality.
Power Distribution Harmonics Case Study of 285-3F Chiller Plant Michael W. Harmon Principle Engineer Savannah River Nuclear Solutions, LLC Savannah River.
Farid Katiraei Ph.D. Candidate
Power Electronics Lecture 1
UTMUTM UNIVERSITI TEKNOLOGI MALAYSIA 1 Relation with multiple disciplines.
Power Systems Last edited: Monday, June 1 st, 2015.
ET3380 Principles and Methods of Electric Power Conversion David Morrisson MS,MBA Week 1.
Power System 2002 Conference: Impact of Distributed Generation CLEMSON UNIVERSITY ELECTRIC POWER RESEARCH ASSOCIATION 1 Distribution Capacitor Placement.
COMPLEXITY SCIENCE WORKSHOP 18, 19 June 2015 Systems & Control Research Centre School of Mathematics, Computer Science and Engineering CITY UNIVERSITY.
21 st May 2015 SMARTGREENS 2015 Lisbon, Portugal Lane Department of Computer Science and Electrical Engineering West Virginia University Analyzing Multi-Microgrid.
1 EE462L, Fall 2011 Motor Drives and Other Applications.
What is a Harmonic The typical definition for a harmonic is
Overcurrent Protection and Voltage Sag Coordination in Systems with Distributed Generation J. Carlos Gomez 1 M. M. Morcos 2 1 Rio Cuarto National University,
1 HARMONIC ANALYSIS OF SELECTED DG DEVICES Pradipta Kumar Tripathy, Durgesh P. Manjure, Dr. Elham B. Makram CLEMSON UNIVERSITY ELECTRIC POWER RESEARCH.
1 Impact of Distributed Generation on Voltage Profile in Deregulated Distribution Systems By: Walid El-Khattam University of Waterloo, Canada
1 Cheng-Ting Hsu Chao-Shun Chen Islanding Operations for the Distribution Systems with Dispersed Generation Systems Department of Electrical Engineering.
Applied Harmonics Control of Harmonics
I. Background The increasing use of Renewable Energy Sources (RES) such as Solar Cell and Wind Turbine Power convertion from DC to AC The using of non.
Farid Katiraei Ph.D. Candidate
1 Chapter 8: Procedure of Time-Domain Harmonics Modeling and Simulation Contributors: C. J. Hatziadoniu, W. Xu, and G. W. Chang Organized by Task Force.
AC Generators (Alternators)
ECE 530 – Analysis Techniques for Large-Scale Electrical Systems
Announcements For lectures 8 to 10 please be reading Chapter 3
Announcements Please read Chapter 3 H4 is 4.34, 4.41, 5.2, 5.7, 5.16
Clemson University Electric Power Research Association CHANDANA BOMMAREDDY CLEMSON UNIVERSITY DG VOLTAGE CONTROL IN AN ISLANDING MODE OF OPERATION.
Patras 9 July 2012 INTEGRATION OF RENEWABLE ENERGY SOURCES IN POWER SYSTEMS Razvan Magureanu University POLITEHNICA Bucharest.
IEEE PES General Meeting, Tampa FL June 24-28, Chapter 1: An Overview of Power System Harmonic Analysis Tutorial on Harmonics Modeling and Simulation.
Announcements For lectures 9 and 10 please be reading Chapter 3
1- Harmonic Sources from Commercial Loads
Chapter 1: An Overview of Power System Harmonic Analysis
Solar Energy. Solar panels Instead of using fossil fuels, solar power technologies use photovoltaic (PV) panels to convert sunlight directly into electricity.
Connecting Low Carbon Generation Clive Goodman Primary System Design Engineer.
HARMONICS AND THEIR EFECTS ON POWER SYSTEM PRESENTED BY: S.M.JAFFER-1CR07EE048 IV Year, EEE,BE.
From Lecture1 vi , ii vo , io Power Processor Controller Source Load
Effects of Harmonics on Capacitors Electrical System
Automated power Factor Correction and Energy Monitoring System
ECE 476 POWER SYSTEM ANALYSIS
HARMONIC MITIGATION USING PASSIVE FILTERS
Power Electronics Department of Electrical and Electronic Engineering
M.KARTHIK (10F41D4307) Under the esteemed guidance of
AC to DC Converters Outline 2.1 Single-phase controlled rectifier
Five level diode clapmed inverter
ECE 333 Green Electric Energy
From Lecture1 vi , ii vo , io Power Processor Controller Source Load
ECE 333 Green Energy Systems
Switch-Mode DC-AC Inverters
ELL100: INTRODUCTION TO ELECTRICAL ENGG.
LOAD BEHAVIOUR DURING VOLTAGE DIPS
AC Drives Dr. Adel A. El-Samahy Department of Electrical Engineering University of Helwan.
ECE 476 POWER SYSTEM ANALYSIS
Components inverters Except where otherwise noted these materials are licensed Creative Commons Attribution 4.0 (CC BY)
Presentation transcript:

EFFECT OF HARMONICS ON DISTRIBUTED GENERATION Dr. Elham Makram Department of Electrical and Computer Engineering Clemson University Clemson, South Carolina 29634-0915 Clemson University Electric Power Research Association DG Conference, Clemson SC March 14, 2002

DG Conference Clemson University March 13-15, 2002 Outline Overview of the effect of nonlinear loads on Power System Harmonics Effect of converter drive and arc furnace Effect of harmonics on power factor Effect of capacitor placement on harmonics Impact of unbalance on harmonics Need for accurate modeling for harmonic analysis Comparison of Time domain and Frequency domain methods Performance analysis of models for nonlinear loads Change in the scenario due to addition of Distributed Generation DG devices and corresponding systems DG Conference Clemson University March 13-15, 2002

DG Conference Clemson University March 13-15, 2002 Effect Of converter drive and arc furnace 2 4 6 8 10 12 14 16 18 20 Current Magnitude (%) TRANS5_49 LINE3 LINE2 LINE1 Line Number 5th 7th 11th 13th 17th 19th 23rd 25th 2 4 6 8 10 12 14 16 18 20 Voltage Magnitude (%) Bus 12 Bus 11 Bus Numbers 5 7 11 13 17 19 23 25 The presence of a 6-pulse converter on the power system causes harmonic currents to flow through the system. Voltage distortion is negligible Arc furnace produces voltage distortion and current distortion; the distortion in voltage being much higher than that in current. As such the AF by itself is more harmful to other customer loads than the converter drive. DG Conference Clemson University March 13-15, 2002

DG Conference Clemson University March 13-15, 2002 Effect Of Harmonics on Power Factor 1 A nonlinear load at a bus causes the power factor at that bus and at buses close to it to drop. 0.95 0.9 Power Factor Linear Load 0.85 AF Load 0.8 0.75 Bus 12 Bus 11 Bus 8 Bus 4 1 Buses 0.9 Placement of power factor improvement capacitors at buses close to the nonlinear load bus worsens the power at the nonlinear load bus, and also at buses close to it. 0.8 Power Factor 0.7 Without capacitor With capacitor 0.6 0.5 0.4 Bus 12 Bus 11 Bus 8 Bus 4 Buses DG Conference Clemson University March 13-15, 2002

DG Conference Clemson University March 13-15, 2002 Effect of Capacitor placement on Harmonics The presence of capacitor banks increases the current and voltage distortion at the nonlinear load bus and the buses close to it. Before capacitor placement After capacitor placement Current Voltage Current Voltage 200 2000 400 2000 100 1000 200 1000 -100 -1000 -200 -1000 -200 -2000 -400 -2000 0.02 0.04 0.06 0.08 0.02 0.04 0.06 0.08 Magnitude in Ampere 0.02 0.04 0.06 0.08 Magnitude in Volt 0.02 0.04 0.06 0.08 Magnitude in Ampere Magnitude in Volt Time (seconds) Time (seconds) Time (seconds) Time (seconds) 250 400 1500 1500 200 300 1000 1000 150 200 100 500 100 500 50 5 10 15 20 25 5 10 15 20 25 5 10 15 20 25 5 10 15 20 25 Harmonic Order Harmonic Order Harmonic Order Harmonic Order DG Conference Clemson University March 13-15, 2002

DG Conference Clemson University March 13-15, 2002 Impact of unbalance on harmonics In addition to characteristic (6n1) harmonics, unbalance introduces uncharacteristic (triplen) harmonics 0.97 0.97 0.96 0.96 0.95 0.95 Unbalance adversely affects the power factor. Comparison is shown between the results obtained using a linear model and those obtained using a nonlinear model for the arc furnace 0.94 0.94 Power Factor Power Factor Nonlinear Model Nonlinear Model Linear Model Linear Model 0.93 0.93 0.92 0.92 0.91 0.91 0.9 0.9 0% 0% 5% 5% 10% 10% 15% 15% 20% 20% 25% 25% Degree of Unbalance Degree of Unbalance DG Conference Clemson University March 13-15, 2002

DG Conference Clemson University March 13-15, 2002 Impact of unbalance on harmonics Degree of unbalance affects harmonics differently, i.e. with an increase in the degree of unbalance, the non-characteristic harmonics increase, whereas the characteristic harmonics show a decrease. The symmetrical component decomposition of individual harmonics helps to give an insight into the behavior of harmonics under varying degrees of unbalance. Unbalance adversely affects the power factor, although if the unbalance is within practical limits, the drop in the power factor is not very significant. Unbalanced conditions render certain models for nonlinear loads, to be inadequate for use. DG Conference Clemson University March 13-15, 2002

DG Conference Clemson University March 13-15, 2002 Comparison of Time domain and Frequency domain methods 14 12 Frequency domain method of harmonic analysis gives pessimistic results, and is not equipped to accurately solve for certain types of harmonic analysis problems. 10 8 Current in line 3 (% magnitude) Time 6 Frequency 4 2 5 7 11 13 17 19 23 25 Harmonic Number 25 20 The DC side load also determines the amount of harmonics injected into the system. There is no provision in the frequency domain method to model this. 15 DC load 1/4 DC load Current Magnitude (%) 1/8 DC load 10 5 5 7 11 13 17 19 23 25 Harmonic Number DG Conference Clemson University March 13-15, 2002

DG Conference Clemson University March 13-15, 2002 Performance analysis of models for nonlinear loads Voltage-Current characteristics for the arc furnace Using a Linear model Using a Nonlinear model 400 200 300 150 200 100 100 50 Voltage (V) Voltage (V) -100 -50 -200 -100 -300 -150 -400 -150 -100 -50 50 100 150 -200 -150 -100 -50 50 100 150 Current (kA) Current (kA) Preserving the nonlinearity of the problem yields a more accurate solution. DG Conference Clemson University March 13-15, 2002

DG Conference Clemson University March 13-15, 2002 Original Picture Traditional Distribution System NONLINEAR LOADS Residential Commercial Industrial DG Conference Clemson University March 13-15, 2002

DG Conference Clemson University March 13-15, 2002 Change in the scenario due to addition of Distributed Generation System would no longer be radial DG devices would have power conditioning sub-systems, which would inject harmonics into the distribution system as well This situation would be different from the case of multiple nonlinear loads DG Conference Clemson University March 13-15, 2002

DG Conference Clemson University March 13-15, 2002 DG devices and corresponding systems to be considered DG device Interconnection Type of system Photovoltaics Microturbines Wind Energy Inverters Converter – Inverter pair Induction generator – Converter - Inverter pair Residential Commercial Industrial DG Conference Clemson University March 13-15, 2002

DG Conference Clemson University March 13-15, 2002 Preliminary results: Impact of a PV System A Typical Residential PV System DG Conference Clemson University March 13-15, 2002

DG Conference Clemson University March 13-15, 2002 Modeling of Residential System Residential system is modeled by considering four typical houses. Loads considered in each house are: Linear Loads (assumed): Incandescent light Refrigerator load Nonlinear Loads: Compact Fluorescent Lights Television Set Heat pump DG Conference Clemson University March 13-15, 2002

DG Conference Clemson University March 13-15, 2002 Cases Studied Case 1: DG as a standalone unit supplying residential loads Case 2: Residential system loads fed by the distribution system only Case 3: Residential loads fed by PV and the distribution system DG Conference Clemson University March 13-15, 2002

DG Conference Clemson University March 13-15, 2002 Results for Case 1 Voltage and current at the load bus 4.82 4.84 4.86 4.88 4.9 -150 -100 -50 50 100 150 Time(seconds) Magnitude (volts) Load voltage waveform 4.83 4.85 4.87 4.89 -60 -40 -20 20 40 60 Magnitude (amperes) Load current waveform 5 10 15 25 30 Harmonic Order Magnitude (%) Frequency Spectrum DG Conference Clemson University March 13-15, 2002

DG Conference Clemson University March 13-15, 2002 Results for Cases 2 & 3 COMPARISON OF LOAD VOLTAGE 1 2 3 4 5 6 7 8 9 10 Magnitude (%) 11 13 15 17 19 21 23 25 Harmonic order Case 2 Case 3 DG Conference Clemson University March 13-15, 2002

DG Conference Clemson University March 13-15, 2002 Results for Cases 2 & 3 COMPARISON OF LOAD CURRENT 50 Case 2 Case 3 45 40 35 30 Magnitude (%) 25 20 15 10 5 3 5 7 9 11 13 15 17 19 21 23 25 Harmonic order DG Conference Clemson University March 13-15, 2002

DG Conference Clemson University March 13-15, 2002 Conclusions Harmonics produced on the load side by the PV system were not significant compared to the high current distortion caused due to the household nonlinear loads. Harmonic distortion injected into the distribution system decreased after connecting the PV system The harmonics picture may change than the way it appears now when number of PV systems connected to the distribution system increase. DG Conference Clemson University March 13-15, 2002

DG Conference Clemson University March 13-15, 2002 Work In Progress Modeling of other types of DG – Micro turbines, Wind Energy Effect of DG on harmonic distortion in case of commercial and industrial systems Impact of varying degrees of penetration of DG Combined effect of different combinations of DG devices DG Conference Clemson University March 13-15, 2002

DG Conference Clemson University March 13-15, 2002 Future Power System Transmission system Load 2 Load 5 Load 1 Solar Energy Fuel cell Microturbine Load 6 Load 3 Load 4 Wind energy Distribution system DG Conference Clemson University March 13-15, 2002