Protein Adsorption Affects Osteoblast- Glass Adhesion Strength as Measured by Colloidal Probe Atomic Force Microscopy Jackson Cahn Whitman College.

Slides:



Advertisements
Similar presentations
MECHANICAL PROPERTIES OF MATERIALS
Advertisements

1 ASTM : American Society of Testing and Materials.
Scanning Probe Microscopy
SCANNING PROBE MICROSCOPY By AJHARANI HANSDAH SR NO
Lecture 10. AFM.
Sample laser cantilever quadrant photodetector tip AFM measures x, y, and z dimensions. The AFM works by scanning a silicon or silicon nitride tip, with.
Spectroscopic Techniques for Probing Solid Surfaces Part II of Surface Primer.
History and Applications of Atomic Force Microscopy Gregory James PhD Candidate Department of Chemical Engineering 1.
Get to the point!. AFM - atomic force microscopy A 'new' view of structure (1986) AlGaN/GaN quantum well waveguide CD stamper polymer growth surface atoms.
Atomic Force Microscop (AFM) 3 History and Definitions in Scanning Probe Microscopy (SPM) History Scanning Tunneling Microscope (STM) Developed.
Introduction to Nonlinear Analysis
Atomic Force Microscopy
Copyright © 2005 SRI International Scanning Probe Microscopy “Seeing” at the nanoscale.
Slide # 1 SPM Probe tips CNT attached to a Si probe tip.
Chapter 13 States Of Matter.
Methods and Tehniques in Surface Science
TAPPINGMODE™ IMAGING APPLICATIONS AND TECHNOLOGY
How Do We Measure Forces at the Nanoscale Level? 1 © 2009 McREL Physical Science Lesson 7 How Do We Measure Forces at the Nanoscale Level? Investigating.
UIC Atomic Force Microscopy (AFM) Stephen Fahey Ph.D. Advisor: Professor Sivananthan October 16, 2009.
2.002 Tutorial Presentation Problem 1-Atomic Force Microscopy Justin Lai.
Stress and Strain Unit 8, Presentation 1. States of Matter  Solid  Liquid  Gas  Plasma.
Fluid Interface Atomic Force Microscopy (FI-AFM) D. Eric Aston Prof. John C. Berg, Advisor Department of Chemical Engineering University of Washington.
Nanonics General SPM The Nanonics SPM Advantage Standard Atomic Force Imaging at the Highest of Resolutions and Quality Coupled with the Unique.
Tomáš Bílý, Martin Šemro Simultaneous AFM and light microscopy of live cells: nano- and microworld within one picture.
NANO 225 Micro/Nanofabrication Characterization: Scanning Probe Microscopy 1.
3.052 Nanomechanics of Materials and Biomaterials Prof. Christine Ortiz DMSE, RM Phone : (617) WWW :
Common scanning probe modes
Scanning Probe Microscopy Colin Folta Matt Hense ME381R 11/30/04.
5 kV  = 0.5 nm Atomic resolution TEM image EBPG (Electron beam pattern generator) 100 kV  = 0.12 nm.
Atomic Force Microscopy (AFM)
Intermolecular Forces. Forces that hold solids and liquids together may be ionic or covalent bonding or they may involve a weaker interaction called intermolecular.
 What was the issue?  Why does it happen?  How does it happen?  Influencing factors  Filtration effects  Remedial action  Conclusion.
Sample Scanner Laser Position Sensitive Photodiode Tip Cantilever AFM working in IFJ atomic force microscopy FNFN FLFL.
Enzymes.
Atomic Force Microscope Nanoindentation/Scratching
AFM Images Bacteria Mosquito eye DNA molecules t&view=article&id=51&Itemid=57.
EEM. Nanotechnology and Nanoelectronics
Force Microscopy of Nonadherent Cells: A Comparison of Leukemia Cell Deformability Rosenbluth, Lam, and Fletcher (2006) Presented by: Aisha Bobb-Semple.
1 The Effect of Seal Width & Material Stiffness on Peel Strength (F88 Technique C) Dan Burgess 28 Oct, 2015.
3.052 Nanomechanics of Materials and Biomaterials Prof. Christine Ortiz DMSE, RM Phone : (617) WWW :
Atomic Force Microscopy (AFM)
Get to the point!.
Get to the point!.
P-values.
Modeling Atomic Force Microscopy Helen Tsai Group 10
Scanning Probe Microscopy
Work done by a variable force
Scanning Probe Microscopy History
7x7 surface have been removed and deposited.
MultiView 400™ Product Presentation Nanonics MultiView 400™
Modelling of Atomic Force Microscope(AFM)
Scanning Probe Microscopy History
Tapping mode AFM: simulation and experiment
NANO 230 Micro/Nano characterization
Imaging Structural Proteins
Surface ultrastructure and mechanical property of human chondrocyte revealed by atomic force microscopy  C.-H. Hsieh, Ph.D., Y.-H. Lin, Ph.D., S. Lin,
INSPECTION TECHNIQUES
Volume 74, Issue 3, Pages (March 1998)
Local Viscoelastic Properties of Live Cells Investigated Using Dynamic and Quasi-Static Atomic Force Microscopy Methods  Alexander Cartagena, Arvind Raman 
Lateral Mechanical Coupling of Stereocilia in Cochlear Hair Bundles
Anne Marie W. Bartosch, Rick Mathews, John M. Tarbell 
Scanning Probe Microscopy
Atomic Force Microscope
Evaluation of tablet dosage form 4) Disintegration
Atomic Force Microscopy
Volume 86, Issue 5, Pages (May 2004)
Quantitative Analysis of the Viscoelastic Properties of Thin Regions of Fibroblasts Using Atomic Force Microscopy  R.E. Mahaffy, S. Park, E. Gerde, J.
Volume 74, Issue 3, Pages (March 1998)
Probing the Lipid Membrane Dipole Potential by Atomic Force Microscopy
Fig. 3 Underwater adhesion performance of adhesive coatings made of mammalian LC domain proteins. Underwater adhesion performance of adhesive coatings.
Presentation transcript:

Protein Adsorption Affects Osteoblast- Glass Adhesion Strength as Measured by Colloidal Probe Atomic Force Microscopy Jackson Cahn Whitman College

Introduction Previous Findings Time-resolved Adhesion Cleaning Goals  Measure the adhesion forces between individual bone cells (MC3T3-E1) and different types of glasses (bioglasses)  Perfect the method so that these evaluations can be consistent and easily compared  Identify environmental factors possibly affecting measurements 0.5 mm 10x objective20x objective

Atomic Force Microscopy (AFM)  Usually, this technique is used to scan a surface and generate an image.  However, the ability to correlate displacement of the cantilever to deflection of the laser allows for high precision force measurement. Image: Wikimedia Commons Introduction Previous Findings Time-resolved Adhesion Cleaning

Colloidal Probe AFM  AFM cantilevers are made from silicon nitride.  To investigate other materials, we need to modify the tip.  This also makes for a larger contact surface for the cell. Glass Bead Epoxy ~50 µm Introduction Previous Findings Time-resolved Adhesion Cleaning

A Typical Force Curve  Start with the sphere indenting the cell, leave it in contact for a specified contact time  At first, there will be a strong repulsive force due to the compressive elasticity of the cell  As the sphere leaves the cell surface, adhesion will provide a strong negative force  At a sufficient distance, these contacts will separate and there will no longer be any force  Eventually the piezo reaches its highest point and begins to descend back towards the cell  There is no force on the probe as it descends until it makes contact with the cell surface  As the probe indents the cell again, the constant compliance (linear) region resumes F admax

: NIST borosilicate glass, Potter glass modified with (CH 3 ) 2 Cl 2 Si Previous Findings  When I arrived: 127 Force Curves As they had been collected, the procedure had been continually tweaked 3 variables: ▪ Contact Time (15s, 60s, 300s, 900s) ▪ Sphere type ▪ Culture Medium Composition (α-MEM, Media) (NIST, Hydrophobic) α-MEM has: Salts Glucose Ribonucleosides Vitamins Other Nutrients Media adds: 10% Fetal Bovine Serum (v/v) Kanamycin Antibiotic Introduction Previous Findings Time-resolved Adhesion Cleaning

Results n=

Shapes: Evidence of Contamination Only ever on the first contact with a cell! Introduction Previous Findings Time-resolved Adhesion Cleaning

Previous Data--Contamination Introduction Previous Findings Time-resolved Adhesion Cleaning

Time-resolved Adhesion  Repeat 15s adhesion measurements on different cells using the same tip and plot them sequentially  Observe cleanliness effects  Look for trends due to pH, temperature changes  Account for differences in tip geometry, cantilever k, etc. Introduction Previous Findings Time-resolved Adhesion Cleaning

Sample Data Final Plateau ∆F admax Time to complete coverage Introduction Previous Findings Time-resolved Adhesion Cleaning

Time-resolved Adhesion--Results  Final Plateau: Higher adhesion in α-MEM Lower adhesion on hydrophobic glass Data agree with initial results  Protein Coverage: Adhesion decreases more in α-MEM Adhesion decreases more on NIST glass Hydrophobic glass in media actually shows increased adhesion with coverage Data agree with initial results  Protein Coverage Time: Coverage time increase in α-MEM Coverage time increases with hydrophobic glass Introduction Previous Findings Time-resolved Adhesion Cleaning

Results--Final Plateau Introduction Previous Findings Time-resolved Adhesion Cleaning

Time-resolved Adhesion--Results  Final Plateau: Higher adhesion in α-MEM Lower adhesion on hydrophobic glass Data agree with initial results  Protein Coverage: Adhesion decreases more in α-MEM Adhesion decreases more on NIST glass Hydrophobic glass in α-MEM actually shows increased adhesion with coverage Data agree with initial results  Protein Coverage Time: Coverage time increase in α-MEM Coverage time increases with hydrophobic glass Introduction Previous Findings Time-resolved Adhesion Cleaning

Results--Protein Coverage Introduction Previous Findings Time-resolved Adhesion Cleaning

Results--Coverage--Sample Results  Smaller decrease in force  Faster decrease in force  Increase in force with coverage NIST glass in α-MEMNIST glass in mediumHydrophobic in medium Introduction Previous Findings Time-resolved Adhesion Cleaning

Time-Resolved Adhesion--Conclusions  Decrease is due to protein adsorption  Proteins responsible for adhesion may be hydrophilic in nature  After coverage, results are consistent and significant  Cells under serum starvation have increased adhesion  Cells bond more strongly to hydrophilic glasses Introduction Previous Findings Time-resolved Adhesion Cleaning

Recommendations  For an in vivo application, protein coverage will be immediate and irreversible  Therefore, when evaluating materials the post-coverage results are more significant, and also more consistent  Making recordings in media, make at least 5 contacts before data is considered valid Introduction Previous Findings Time-resolved Adhesion Cleaning