Myung Sai Chung Report to CGPM ‘2007. 2 ■ Overview of the CCL ■ Recommendations ■ Decisions Contents.

Slides:



Advertisements
Similar presentations
Testing Relational Database
Advertisements

Agency reviews: purpose and stages of the review process Achim Hopbach.
United Nations Statistics Division
Teacher Evaluation and Pay for Performance Michigan Education Association Spring 2011.
JCTLM REFERENCE LABORATORY SERVICES Report of WG2 November 14, 2005 _________________________________________.
CMCs and the BIPM Key Comparison Database Raul Fernando Solís Betancur 2012.
Myung Sai Chung. 2 Contents ■Overview of the CCL ■Recommendations ■Decisions ■Joint Working Group CCL/CCTF.
National Commission for Academic Accreditation & Assessment Preparation for Developmental Reviews.
CMCs and the BIPM Key Comparison Database Raul Fernando Solís Betancur 2015.
Expanded Version of COSO a presentation by Steve Wadleigh Expanded Version of COSO a presentation by Steve Wadleigh Standards for Internal Control in the.
Traceability to the SI: What does it mean in practice? Ms. Sally Bruce and Ms. Dana Leaman National Voluntary Laboratory Accreditation Program NIST.
Promoting Excellence in Family Medicine Enabling Patients to Access Electronic Health Records Guidance for Health Professionals.
1 Practical Interpretation of Unbroken Chain in Metrological Traceability as to VIM 3 Center for Measurement Standards (CMS) Industrial Technology Research.
A Review ISO 9001:2015 Draft What’s Important to Know Now
Accreditation and Proficiency Testing. APT Subcommittee MembershipMeeting Activities 21 members, 15 non- Commissioners Representation: Accreditation bodies.
Conducting the IT Audit
AICT5 – eProject Project Planning for ICT. Process Centre receives Scenario Group Work Scenario on website in October Assessment Window Individual Work.
Slide 1 D2.TCS.CL5.04. Subject Elements This unit comprises five Elements: 1.Define the need for tourism product research 2.Develop the research to be.
How to Write a Critical Review of Research Articles
PA Department of Environmental Protection Continuous Source Monitoring Manual (Manual, Revision 8)
Institutional Arrangements for Adaptation Achala Chandani Researcher International Institute for Environment and Development european capacity building.
Report to the 23 rd General Conference on Weights and Measures CONSULTATIVE COMMITTEE ON PHOTOMETRY AND RADIOMETRY.
IAEA International Atomic Energy Agency Presentation held at the Workshop on Lessons Learned from IRRS Missions Moscow, Russian Federation 9-11 December.
TECO2005WRC/PMOD Quality Management1 The World Radiometric Reference and its Quality System ISO/IEC Wolfgang Finsterle, Isabelle Rüedi, and Silvio.
CCEM Comité Consultatif d’ Électricité et Magnétisme Report of the President to the 22 nd CGPM Ernst O. Göbel PTB Braunschweig and Berlin, Germany.
CONSULTATIVE COMMITTEE FOR PHOTOMETRY AND RADIOMETRY Report to the 22 nd General Conference on Weights and Measures.
IRES: an update on the revision process Vladimir Markhonko United Nations Statistics Division The 4 th meeting of the Oslo Group on energy statistics Ottawa,
APPRAISAL OF THE HEADTEACHER GOVERNORS’ BRIEFING.
1 Accredited Standards Committee C63 ® - EMC Subcommittee 1: Techniques and Developments Zhong Chen SC1 Chair
Rolling Resistance Standards Work at ISO (TC31 WG6) Prepared for GRB Review 19 Sep 2011 Angela Wolynski WG6 Convenor Informal document GRB (54th.
1.  Interpretation refers to the task of drawing inferences from the collected facts after an analytical and/or experimental study.  The task of interpretation.
1 The GCC Metrology Group GULFMET Mohammad Al Mulla GSO - Building for Integration
CSOC – Certification Structure Oversight Committee Application Guidance October 2015.
IAEA International Atomic Energy Agency Methodology and Responsibilities for Periodic Safety Review for Research Reactors William Kennedy Research Reactor.
1 IRES, version 0: an overview Vladimir Markhonko United Nations Statistics Division The Oslo Group on Energy Statistics Fifth meeting, Cork, Ireland,
IAEA International Atomic Energy Agency LESSONS LEARNED ON THE REGULATION OF NUCLEAR SAFETY Presentation to the Workshop on Lessons Learned from IRRS Missions.
The Data Sharing Working Group 24 th meeting of the GEO Executive Committee Geneva, Switzerland March 2012 Report of the Data Sharing Working Group.
ICAJ/PAB - Improving Compliance with International Standards on Auditing Planning an audit of financial statements 19 July 2014.
2006 NCSL International Workshop and Symposium August 07 Management of the AC-DC voltage transfer difference comparison in the SIM region Sara Campos CENAM.
September Matthew Walters – Derbyshire Sophie Leney – Norfolk Kate Bailey – Surrey.
Workshop on Standard operating procedures in the phytosanitary field, September Belgrad Serbia Monica Maria COJANU, Romania.
CCM Working Group on CMCs 1 Report on 11 May 2011 meeting of CCM-WGCMC & on Related Issues Chris Sutton, Chair Measurement Standards Laboratory of New.
Yasuhisa Fujii National Metrology Institute of Japan (NMIJ) Jia-Lun Wang National Time and Freq. Standards Lab,Taiwan (TL) Michael Wouters and Bruce Warrington.
Key Comparisons in Electrochemistry Significance to Metrology and Global Trade Kenneth W. Pratt* and David L. Duewer National Institute of Standards and.
UPDATES ON JCRB ACTIVITIES. DEC Meeting June Member States 20 Associates of the CGPM (representing 30 over countries) 2 international.
AUDIT STAFF TRAINING WORKSHOP 13 TH – 14 TH NOVEMBER 2014, HILTON HOTEL NAIROBI AUDIT PLANNING 1.
Traceability in Chemical Measurement Comparable results are needed in order to avoid duplicating measurements which cost time and money. Comparable results.
process and procedures for assessments
Update on the Latest Developments in Government Auditing Standards
Consultative Committee on Ionising Radiation (CCRI) June 2016
REACH 2018 Find your co-registrants and prepare to register jointly.
NCWG Terms of Reference NCWG April 2016, IHB, Monaco
8th CCAUV RMO WG meeting feed to CCAUV
CMC Submission and Reviewing Process
REPORT OF THE ELECTRONIC WORKING GROUP UNEP(DEC)/CAR WG.29/INF.12
Life Cycle Models PPT By :Dr. R. Mall.
Roadmap to Enhanced Technical Regulations of WMO
CCL President report to the 2016 meeting of the CCU
JCRB Report to the CCL Meeting
Activity reports on CCTF/CCL JWG on Optical Frequency Metrology
WG on GNSS Report APMP Technical Committee on Time and Frequency
Philippe Richard OIML Delegate to the CCU and CCM President
Joint WG on Guidance for an Integrated Transport and Storage Safety Case for Dual Purpose Casks TM TM to Produce Consolidated Drafts of the IAEA’s.
Status report of “Hybrid Comparisons as CMC Evidence”
Summary report of EC meeting I
Update on the Developments in Government Auditing Standards
Gianna Panfilo BIPM, Sèvres, France
TECHNOLOGY ASSESSMENT
AICT5 – eProject Project Planning for ICT
Presentation transcript:

Myung Sai Chung Report to CGPM ‘2007

2 ■ Overview of the CCL ■ Recommendations ■ Decisions Contents

3 Overview of the CCL

4 Introduction ■ Established in 1952 as the CCDM (Consultative Committee for the Definition of the Metre) ■ Changed name to CCL (Consultative Committee for Length) IN 1997 ■ 12 th Meeting ► September 2005 ■ 13 th Meeting ► September 2007

5 Members (1/2) ■ President ► Dr. Chung, Myung Sai ► Member of the Comité International des Poids et Mesures, President University of Science and Technology (UST), Taejon. ■ Executive secretary ► Mr. Raymond Felder ► Bureau International des Poids et measures [BIPM].

6 Members (2/2) ■ Members: 20 institutes (~2007) ► [BNM-INM], Paris ► [MIKES], Helsinki ► [CENAM], Querétaro ► [CMI], Praha ► [VNIIM], St Petersburg ► [IMGC-CNR], Torino ► [KRISS], Taejon ► [NIM], Beijing ► [NIST], Gaithersburg ► [JILA], Boulder ■ Official Observers ► Centro Español de Metrologia [CEM], Madrid ► [NML CSIRO], Lindfield ► [UME], Gebze-Kocaeli ► [NPL], Teddington ► [NRC-CNRC], Ottawa ► [NMIJ/AIST], Tsukuba ► [NMi VSL], AR Delft ► [METAS], Bern-Wabern ► [PTB], Braunschweig ► [SMU], Bratislava ► [BIPM], Sèvres ■ New Members: 2 institutes ► [SPRING], Singapore ► [BEV], Austria

7 Working Groups of CCL (1) ■ WG on Dimensional Metrology (WGDM) ■ Terms of Reference ► To maintain links CCL with the regional metrological cooperation organizations ► To make recommendations to the CCL on the needs and priorities for additional international comparisons in dimensional metrology under the auspices of the CCL. ► To act as a focus for information exchange on international comparisons of dimensional metrology standards and techniques, through the use of suitable Discussion Groups. ► To facilitate the inter-regional CMC review process. ► To establish and operate Discussion Groups in areas of new technology, in which there are needs for dimensional metrology

8 Working Groups of CCL (2) ■ Joint Working Group on Frequency Standards (JWGFS) ■ Terms of Reference ► To make recommendations to the CCL for radiations to be used for the realization of the definition of the metre and to make recommendations to the CCTF for radiations to be used as secondary representations of the second; ► To maintain together with BIPM the list of recommended frequency standard values and wavelength values for applications including the practical realization of the definition of the metre and secondary representations of the second; ► To take responsibility for key comparisons of standard frequencies such as CCL – K11; ► To respond to future needs of both the CCL and CCTF concerning standard frequencies relevant to the respective communities.

9 CCL Key Comparisons ► K11: MeP stabilized lasers, former BIPM.L-K11 K10: Comparison for I 2 stabilized He-Ne laser was closed ► K1: gauge blocks up to 500 mm (including former CCL-K2 for long gauge blocks) ► K3: angle standards (polygons and angle blocks) ► K4: cylindrical diameter standards ► K5: step gauge K6: Two-dimensional coordinate measuring machine artefacts was closed ► K7: line scales ► K8: surface texture standards

10 Pilot Studies on Nanometrology ■ CCL operated a successful series of Nano pilot studies to establish standards in nanometroloy ► The future work in nanometrology would expect eventually a cross-CC working group on nanometrology Nano1 linewidth (CD mask) Nano2 step heights Nano3 linescales Nano4 1D gratings Nano5 2D gratings Nano6 linewidth (Single Crystal CD) NMIJ-PTB1D gratings (pitch < 100nm) starting completed draft A delayed completed Pilot StudyArtefactsStatus

11 CCL/WGDM suggested a new KC scheme to CIPM (2005) ► All dimensional metrology KCs do not compare national standards, but test the competence of participating laboratories, support their CMCs ► The artefacts used in different comparisons (CC or RMO) have different properties, have limited and usually unpredictable stability. Therefore a strict numerical linking of the comparisons is in most cases not appropriate. CCL-RMO KC scheme Linking comparisons through testing the statistical consistency of a subset of participating laboratories common to both comparisons RMO1 RMO2 RMO3 Suggestions

12 Specific Concerns and Recommendations of the CIPM (2006) ■ The CIPM had expressed some concerns and requested some actions from the CCL and the WGDM on the following issues (2006) ► Why gauge block comparisons warrant a different approach from other artefact-based comparisons? ► In future comparisons, should the linking be included as part of the protocol?. ► The question of stability of the travelling artefact could easily be resolved by adopting a star formation for the comparisons. ► Recommended that the WGDM should meet more frequently at the BIPM. ► Develop a self-standing document from the CCL on how future comparisons would be organized. ► Develop for a paper on the limitations of gauge block comparisons and the consequences for linkages.

13 Responses of WGDM and CCL to CIPM (2007) ■ The WGDM comments on the questions raised items prepared at the 2007 WGDM meeting. ► WGDM WGDM-responses-to-CIPM ■ CCL proposed comparison scheme which had the necessary flexibility, satisfied the needs of the CIPM MRA and took into account problems encountered in CIPM KCs. ► WGDM CCL comparison scheme: ■ A generalized basis is reported for linking a CIPM KC with Regional KCs. ► WGDM Draft_Paper_Linking_Key_Comparisons

14 Responses ■ The question of stability could easily be resolved by adopting a star formation for the comparisons. [§7.6, para 12] The usual approach, for performing comparisons with an artefact that may be unstable is to use a star circulation scheme, in which the pilot monitors the stability of the artefact, by making measurements in-between those of the participants. However, a star formation has some disadvantages: additional cost due to the extra transportation and measurements by the pilot laboratory; additional time needed for the comparison; increased damage to the artefacts from the additional measurements. The participants nearer the end of the circulation are disadvantaged due to the damage that has occurred by the time that they receive the gauge blocks. ■ Why gauge block comparisons warrant a different approach from other artefact-based comparisons (been triggered by concern about the large number of comparisons being organized. [§7.6, para 2] The first issue is artefact damage. Although gauge blocks are measured using optical interferometry, the mechanical (‘wringing’) process of preparing the gauge block causes damage to the surfaces, and the gauge block length measured by different participants can be affected by this damage. The noted benefits of a star circulation scheme are often outweighed by the damage caused by the additional measurements. ■ Another important concern is that there is a potential systematic error in each gauge block measurement made by optical interferometry. The specific nature of this error and its effect are critical to understanding the problems of gauge block comparisons, so they are hereby given in some more detail. Typically the surfaces of the gauge block and the reference plate, to which it must be attached for interferometric measurement, have different mechanical roughnesses and optical constants (complex refractive index). The measurement result obtained using optical interferometry is a combination of the physical length of the gauge block, perturbed by the difference in surface properties. The perturbation of the result is commonly called the ‘phase correction’ and its size is typically –40 nm to +10 nm. The exact values depends on the individual properties of the gauge and plate surfaces and are unique to each combination of gauge and platen. It should be noted that a typical measurement uncertainty for a 1 mm gauge block is 20 nm (at k = 2), so the phase correction must be accounted for in order to achieve the typical client calibration service uncertainties. Also to be noted is that the roughness value is quite different from gauge to gauge and from plate to plate and is generally not predictable, even for gauges in the same set or for plates owned by one NMI. There are techniques that can be used to calculate the phase correction, but they are not perfect and some residual error usually remains. For long gauge blocks (L > 100 mm), the phase correction is very difficult to measure and almost all NMIs (including CCL members) cannot determine its value. Instead, it is common to increase the overall uncertainty to account for this present, but unknown systematic error. The magnitude of the error will still be of the order of 40 nm and if a numerical link is to be made between two

15 international comparisons, where different artefacts are used, the link may introduce a significant artificial offset between NMIs. ■ Develop a paper on the limitations of gauge-block comparisons and the consequences for linkages. [§7.6, para 13] These limitations have been discussed in three papers: Final report on CCL-K1 - Metrologia, 2002, 39, n°2, (full Metrologia paper, peer reviewed) Final report on CCL-K2 - Metrologia, 2003, 40, Tech. Suppl., Final report on EUROMET.L-K2 - Metrologia, 2006, 43, Tech. Suppl., Alternative linkage mechanisms have been discussed at WGDM 2006 and partly during the key comparison analysis workshop during WGDM 2005, attended by members of the BIPM Director’s Advisory Group on Uncertainty. These discussions were recorded in the minutes. The consequences for linkages are discussed in the following (with CLL and RMO gauge block comparisons cited as specific examples): Decker et al, Measurement Science and the Linking of CIPM and Regional Key Comparisons, to be submitted to Metrologia. ■ In future comparisons the linking should be included as part of the protocol. [§7.6, para 9] WGDM agrees that this is important and is actively exploring linking mechanisms which can be written into future protocols. The issue of linking mechanisms is under discussion in: WGDM/ WGDM position paper on comparisons WGDM/ Key comparison portfolio WGDM/ Measurement Science and the Linking of CIPM and Regional Key Comparisons ■ Recommend that the WGDM meets at the BIPM occasionally. [§7.6, para 13] The WGDM welcomes this suggestion and we shall strive to meet at the BIPM as often as our membership finds it possible. Currently, the WGDM generally meets every year and during years when there is a CCL meeting, the WGDM meets at the BIPM. ■ Develop a self-standing document from the CCL on how future comparisons would be organized. [§7.6, para 14] The plan of the new style of CCL-RMO key comparisons was presented to and accepted by the 11th CCL meeting and is discussed in the official minutes of the meeting [see CCL report of the 11th meeting, §5.3 Decision CCL-WGDM-1 & §5.3 Decision CCL-WGDM-2]. The WGDM has started preparing a new paper on this subject and welcomes the offer of joint authorship extended by the BIPM.

16 Consequences of the closure of the BIPM length section ■ In 2003, the 22nd General Conference endorsed the proposal of the CIPM to close the BIPM Length section during 2006 ■ BIPM.L-K11 will be piloted by BEV (Austria) and is renamed CCL-K11

17 Recommendations

18 Recommendation CCL-1a (2005) ■ Considering that: ► improved frequency values for radiations of some high-stability cold ion standards already documented in the recommended radiations list have recently become available; ► improved frequency values for the infra-red gas-cell-based optical frequency standard in the optical telecommunications region, already documented in the recommended radiations list, have been determined; ► improved frequency values for certain iodine gas-cell standard, already documented in the subsidiary recommended source list, have been determined; ► frequencies of new cold atoms, of atoms in the near-infrared region and of molecules in the optical telecommunications region have been determined by femtosecond comb-based frequency measurements for the first time; ■ Recommends that: ► updated frequency values for the single trapped 88 Sr + ion quadrupole transition, the single trapped 199 Hg + quadrupole transition and the single trapped 171 Yb + quadrupole transition; ► an updated frequency value for the Ca atom transition; ► an updated frequency value for the C 2 H 2 -stabilized standard at 1.54 μ m; ► an updated frequency value for the I 2 -stabilized standard at 515 nm; ► the addition of the 87 Sr atom transition at 698 nm; ► the addition of the 87 Rb atom two-photon transitions at 760 nm; ► the addition of the 12 C 2 H 2 ( ν 1 + v3) band and the 13C2H2 ( ν 1 + v3) and ( ν 1 + v3 + ν 4 + v5) bands at 1.54 μ m. ■ Revision of the Mise en Pratique list

19 Recommendation CCL-1b (2005) ■ considering that: ► the 2003 list of recommended radiations for the realization of the metre, including radiations of other optical frequency standards, was comprehensively reorganized and recently published in Metrologia 2005 and is available on the website of the International Bureau of Weights and Measures (BIPM); ► the number (six) of proposed changes to the values already contained within the list is small; ► only four new radiations are suggested; ■ proposes that: ► these changes be incorporated into the database’ recommended radiations maintained on the BIPM website in a manner which highlights the updated values relative to the 2003 list; ► these changes also be published as a short supplementary report in Metrologia.

20 Recommendation CCL-2 (2005) ■ considering ► the significant advance and growth in absolute frequency values of optical frequency standards brought about by comb measurements; ► the differing accuracy requirements of the CCL length metrology community and the CCTF secondary representations criteria; ■ proposes that: ► the MeP-CCL list of Recommended Radiations and CCTF Secondary Representation list be combined into a single list of “Recommended frequency standard values for applications including the practical realisation of the metre and secondary representations of the second”; ► the CCL-MePWG and CCL/CCTF JWG be combined into a single CCL-CCTF frequency standards working group; ► the CCL may wish to select those frequencies which it considers important to highlight for use in high accuracy length metrology; ► other frequencies be proposed, evaluated and maintained on the frequency standards list by a CCL-CCTF frequency standards WG, but not necessarily accepted as CCL-preferred radiations or CCTF-accepted representations; ► the continued maintenance of such a frequency standards “category A” list from which the CCL and CCTF accepted values would be selected, together with the “category B” list representing those radiations still available for use, but where no further improvement in values and uncertainties was deemed necessary; ► the CCTF consider, evaluate and highlight those frequencies which it wishes to accept as secondary representations of the second; ► the schedule of CCTF and CCL meetings be rationalised to take place alternately, at appropriate intervals, ideally at a time of year close to but before the CIPM date; ► a meeting of the CCL-CCTF frequency standards WG should take place prior to the respective CC meeting if appropriate, in order to update the frequency list prior to consideration by the CC; ► the frequency values list is maintained on the BIPM website* with version control, and is structured at a basic level according to wavelength and frequency value, but forms a database capable of being searched by accuracy level or by frequency or by wavelength.

21 Recommendation CCL 1 (2007) ■ CCL considering ► that improved frequency values of molecules in the optical telecommunications region, already documented in the list of standard frequencies, have been determined by femtosecond comb-based frequency measurements ► That frequencies of molecules in the optical telecommunications region have been determined by femtosecond comb-based frequency measurements for the first time; ► that frequencies of certain iodine gas-cell absorptions close to the 532 nm optical frequency standard have been determined by femtosecond comb-based frequency measurements for the first time; ■ proposes that the list of standard frequencies be revised to include the following: ► an updated list of frequency values for the 12 C 2 H 2 ( ν 1 + v3) band at 1.54 µm. ► the addition of frequency values for the 12 C 2 HD (2 ν 1) band at 1.54 µm. ► the addition of frequency values for the hyperfine components of the 37-0 P(142), 35-0 R(121) and 33-0 R(85) iodine absorptions at 532 nm.

22 ■ CCL considering ► that most laser interferometers and many other measuring instruments used for length measurement are based on 633 nm He-Ne lasers, ► that these instruments are often used at uncertainty levels that are large compared to the possible variation of the He-Ne laser vacuum wavelength, ► that the vacuum wavelength of the unstabilized 633 nm He-Ne laser is restricted to within a narrow range by fundamental quantum phenomena ■ recognizing ► that it would be necessary to provide guidance and documentary evidence concerning the value of the vacuum wavelength and its uncertainty that can be expected in the absence of calibration, ► that such evidence could help to avoid unnecessary calibrations of these lasers in such applications, Recommendation CCL 2 (2007)-1

23 Recommendation CCL 2 (2007)-2 ■ recommends ► that the value of the unstabilised helium-neon laser f = THz, = nm, with a relative standard uncertainty of 1.5xE10-6, applies to the vacuum wavelength of a He-Ne laser operating solely on the 3s2-2p4 transition, independent of the isotopic mixture of the neon. ► that an entry for unstabilized helium-neon lasers, operating on the 633 nm (3s2-2p4) neon transition, be included in the second category of the list of standard frequencies, and that an accompanying paper with CCL authority be published in Metrologia

24 Decisions

25 Decision CCL 1 (2007) ■ The Consultative Committee for Length, on the advice of the CCL-CC TF Working Group on Frequency Standards, ■ considering that: ► an inconsistency has been detected in the specified frequency modulation width required to realise the acetylene 13C2H2 ( 1 + 3) P(16) stabilised laser frequency standard at 1.54  m; ► the frequency modulation conditions appropriate for laser stabilisation to the b10 component of the 127I2 R(106) 28-0 transition at 543 nm do not take account of detection techniques different to 3f detection ■ decides that ► the frequency modulation width relevant to the acetylene 13C2H2 ( 1 + 3) P(16) stabilised laser frequency standard at 1.54  m is changed to frequency modulation width, peak-to-peak of MHz (for 3f detection cases) ► the following sentence is added after the stated 3f frequency modulation width relevant to the 127I2 R(106) 28-0 transition at 543 nm “Other techniques such as FM or modulation transfer detection can be used to realise the standard, provided the value can be shown to remain within the stated uncertainty”

26 Decision CCL 2 (2007) ■ considering that: ► The introduction of femtosecond combs for optical frequency measurement has resulted in the lack of requirement for mid and far infra-red stabilised laser frequencies ► the methane unresolved hyperfine F 2 (2) component, P(7) 3 transition at 3.39  m is one such transition ► the OsO 4 transitions co-incident with the CO 2 laser line at 10  m are also such transitions ■ decides that ► the unresolved methane transition at 3.39  m, and the OsO4 transitions at 10  m, are placed within the second category of the list of standard frequencies

27 Thank you for your attention!

28 Appendix Updated values of the acetylene 12 C 2 H 2 ( 1 + 3) band at 1.54  m

29 Frequency values of the acetylene 12 C 2 HD (2 1) band at 1.54  m, newly reported to the FSWG and CCL

30 f a1 [P(142) 37-0] - f a10 [R(56) 32-0]= (5.0) kHz f a1 [R(121) 35-0]- f a10 [R(56) 32-0]= (5.0) kHz f a1 [R(85) 33-0] - f a10 [R(56) 32-0]= (5.0) kHz Frequency values the a1 components of new absorptions at 532 nm for inclusion in the list of standard frequencies

31 Hyperfine component separations of new absorptions at 532 nm for inclusion in the list of standard frequencies Hyperfine Splittings of theR(121)35-0Transition P(142)27-0Transition R(85)33 -0 Transition