HAPPEX-III, PVDIS, PREx targets D.S. Armstrong April 17 ‘09 1)Cryotargets – what we requested: new 25 cm racetrack cells – status 2) Solid Targets for.

Slides:



Advertisements
Similar presentations
Robert Michaels HAMC Hall A Analysis Workshop 09 C HAMC = Hall A Monte Carlo ROOT / C++ Design Somewhat like SAMC & genercone For HRS only. Uses LeRose.
Advertisements

Lead ( 208 Pb) Radius Experiment : PREX E = 1 GeV, Elastic Scattering Parity-Violating Asymmetry PREX : density -dependence of the symmetry energy. Nuclear.
NDVCS measurement with BoNuS RTPC M. Osipenko December 2, 2009, CLAS12 Central Detector Collaboration meeting.
1 Pion beam tracker for HADES Jerzy Pietraszko CBM Collaboration Meeting, March 9-13, 2009, GSI, Darmstadt.
E : HRS Cross Section Analyses Vincent Sulkosky Massachusetts Institute of Technology GMp Collaboration Meeting September 24 th, 2012.
Navaphon Muangma (Tai) “SRC Weekly Meeting”, June 19, 2011 SRC Weekly Meeting June 19, 2012  Revisit Optics for LHRS,  LHRS Timing, RHRS Timing  BigBite.
Lh 2 target for an 11 GeV Møller - prospect - S. Covrig hall c, jlab 14 august 2008 hp lh 2 targets for pv q weak target design cooling.
Jin Huang & Vincent Sulkosky Massachusetts Institute of Technology Boson 2010 Workshop Sept 20, JLab.
Measurements of F 2 and R=σ L /σ T on Deuterium and Nuclei in the Nucleon Resonance Region Ya Li November 3, 2009 Jlab E02-109/E (Jan05)
Pair Spectrometer Design Optimization Pair Spectrometer Design Optimization A. Somov, Jefferson Lab GlueX Collaboration Meeting September
Super-B Factory Workshop April 20-23, 2005 Super-B IR design M. Sullivan 1 Status on an IR Design for a Super-B Factory M. Sullivan for the Super-B Factory.
DESY PRC May 10, Beyond the One Photon Approximation in Lepton Scattering: A Definitive Experiment at DESY for J. Arrington (Argonne) D. Hasell,
Count rate estimates from TDR Assuming beam intenisties from previous slide and acc *rec from SIM LH2 case [counts/24h] p [GeV/c] beam momentum Solid.
Ion Beam Analysis of Gold Flecks in a Foam Lattice F E Gauntlett, A S Clough Physics Department, University of Surrey, Guildford, GU2 7XH, UK.
Bogdan Wojtsekhowski, Jefferson Lab Experimental search for A’ for APEX collaboration 1.
Update on Cryotarget System Jian-ping Chen GMn Collaboration Meeting, Feb. 24, 2014  Overview  Maintenance/Modifications During Down  Installation Status.
Carissa Capuano College of William and Mary for the G 0 Collaboration Hall C Users Meeting January 14, 2012.
Lecture 11: Quarks inside the proton 9/10/ Idea: try to identify a kinematic regime in which the electrons scatter from pointlike constituents.
Measurements of F 2 and R=σ L /σ T on Deuteron and Nuclei in the Nucleon Resonance Region Ya Li January 31, 2009 Jlab E02-109/E (Jan05)
Status of the Beamline Simulation A.Somov Jefferson Lab Collaboration Meeting, May 11, 2010.
SHMS Optics and Background Studies Tanja Horn Hall C Summer Meeting 5 August 2008.
Hypernuclear Physics in Hall A E Status John J. LeRose December 16, 2009.
Status of the NO ν A Near Detector Prototype Timothy Kutnink Iowa State University For the NOvA Collaboration.
HAPEX III / PVDIS Targets Dave Meekins. Target List Loops – LH2 25 cm – LD2 25 cm – 20 cm Spare Solid target – Dummy tgts of correct length – Optics tgt.
Vincent Sulkosky Massachusetts Institute of Technology Spokespeople: J.-P. Chen, A. Deur, F. Garibaldi Hall A Collaboration Meeting December 10 th, 2012.
Rosen07 Two-Photon Exchange Status Update James Johnson Northwestern University & Argonne National Lab For the Rosen07 Collaboration.
New materials for DUAL: the LNL activity. Dual detector : Best material parameters Two different materials ‘A’ and ‘B’ with two different Young modulus.
HAPPEX-III and PVDIS targets D.S. Armstrong July 22 ‘08 1)Pointing angle measurements – water cell target some old-style nuclear physics… 2) Cryotargets.
Measurement of F 2 and R=σ L /σ T in Nuclei at Low Q 2 Phase I Ya Li Hampton University January 18, 2008.
“Beam Losses” Christian Carli PSB H - Injection Review, 9 th November 2011 Several topics more or less related to beam losses, a study still somewhat at.
Some thoughts on the pointing measurement Nilanga Liyanage.
Neutral Current Deep Inelastic Scattering in ZEUS The HERA collider NC Deep Inelastic Scattering at HERA The ZEUS detector Neutral current cross section.
Update on the Hall C Monte Carlo simulation for 12 GeV Mark Jones.
A Measurement of Two-Photon Exchange in Unpolarized Elastic Electron-Proton Scattering John Arrington and James Johnson Northwestern University & Argonne.
Lecture 9: Inelastic Scattering and Excited States 2/10/2003 Inelastic scattering refers to the process in which energy is transferred to the target,
ILC MDI workshop January 6-8, 2004 PEP-II IR M. Sullivan 1 Interaction Region of PEP-II M. Sullivan for the ILC MDI workshop January 6-8, 2005.
Backgrounds for HAPPEx Ryan Snyder April 7, 2006.
Calorimetry for Deeply Virtual Compton Scattering in Hall A Alexandre Camsonne Hall A Jefferson Laboratory Workshop on General Purpose High Resolution.
Status of Beam Halo/Gas Simulation A.Stradling(Wisconsin) P. Steinberg(BNL) G. Usai (Chicago) Standard Model Group 6 December 2006 A.Stradling(Wisconsin)
E97-110: Small Angle GDH Experimental Status Report E97-110: Small Angle GDH Experimental Status Report Vincent Sulkosky Massachusetts Institute of Technology.
CERF simulation Mitsu 14th Feb Simulation components Production Transportation Detector response
Neutron measurement with nuclear emulsion Mitsu KIMURA 27th Feb 2013.
Update on the HBD Craig Woody BNL DC Meeting May 11, 2005.
L/T separation in the 3 He(e,e’p) reaction at parallel kinematics Freija Descamps Supervisors: Ron Gilman Eric Voutier Co-supervisor: Jean Mougey.
 0 life time analysis updates, preliminary results from Primex experiment 08/13/2007 I.Larin, Hall-B meeting.
A. Bertolin on behalf of the H1 and ZEUS collaborations Charm (and beauty) production in DIS at HERA (Sezione di Padova) Outline: HERA, H1 and ZEUS heavy.
Vincent Sulkosky Massachusetts Institute of Technology Spokespeople: J.-P. Chen, A. Deur, F. Garibaldi Hall A Collaboration Meeting June 13 th, 2013 E97-110:
SoLID Background Update Zhiwen Zhao UVa 2013/11/08 1.
06/2006I.Larin PrimEx Collaboration meeting  0 analysis.
Absolute Polarization Measurement at RHIC in the Coulomb Nuclear Interference Region September 30, 2006 RHIC Spin Collaboration Meeting RIKEN, Wako, Japan.
Deuteron polarimetry from 1.0 to 1.5 GeV/c Ed Stephenson, IUCF EDM discussion April 14, 2006 Based on work from: France:POMME B. Bonin et al. Nucl. Inst.
E97-110: Small Angle GDH Experimental Status Report E97-110: Small Angle GDH Experimental Status Report Vincent Sulkosky Massachusetts Institute of Technology.
Beam on Target Diagnostics Beam on Target Meeting 2013 March Tom Shea.
Present status of production target and Room design Takashi Hashimoto, IBS/RISP 2015, February.
E.C. AschenauerEIC INT Program, Seattle Week 81.
Pb-Parity and Septum Update Presented by: Luis Mercado UMass - Amherst 12/05/2008 Thanks to Robert Michaels, Kent Pachke, Krishna Kumar, Dustin McNulty.
Bryan Moffit PAC32 Dry Run Precision Measurement of the Proton Elastic Cross Section at High Q 2 PAC32 12 GeV Proposal : PR Spokespersons:Bryan.
X. Zheng, July 22-23, 2008, Hall A Parity Collaboration Meeting Xiaochao Zheng University of Virginia July 22-23, 2008 Overview of the experiment, schedule.
JLEIC MDI Update Michael Sullivan Apr 4, 2017.
M. Sullivan Apr 27, 2017 MDI meeting
Warm magnets for LHeC / Test Facility arcs
First data from TOTEM experiment at LHC
R. Kersevan, TE-VSC-VSM 30/06/2016
Emmanuel Tsesmelis TS/LEA 26 January 2007
D. J. Margaziotis HAPPEX Collaboration Meeting
Summary of hadronic tests and benchmarks in ALICE
How to detect protons from exclusive processes
HL-LHC operations with LHCb at high luminosity
Proposal for an Experiment: Photoproduction of Neutral Kaons on Deuterium Spokespersons: D. M. Manley (Kent State University) W. J. Briscoe (The George.
Summary of the FCCee IR Workshop Jan 2017 at CERN
Presentation transcript:

HAPPEX-III, PVDIS, PREx targets D.S. Armstrong April 17 ‘09 1)Cryotargets – what we requested: new 25 cm racetrack cells – status 2) Solid Targets for HAPPEX-III/PVDIS – plan 3) Solid Targets for PREx (from ROM)

Cryotargets for HAPPEX-III/PVDIS HAPPEX-II used 20 cm “racetrack” cell (design: Dimitri Margaziotis, Cal State LA) transverse-flow design - Excellent boiling performance - Geometry – no problem using at HAPPEX-III/PVDIS angles with up to  4 mm raster (vertical acceptance is issue) - PVDIS asked for 25 cm version

New Cell Block Design from Dave Meekins (this is for 10 cm cell)

Cell length for HAPPEX-III 25 cm cell also? Advantages: 1.Swap-compatible with PVDIS cell (mutual spares) 2.Ratio of Al (windows) to lH 2 smaller by  reduced QE background - perhaps reduced boiling (if film boiling at window dominates) 3.somewhat reduced acceptance (  10-15%) at detector for Al windows 4.Luminosity (assuming cryogen load can be delivered) Disadvantages: 1.Increase radiative tail losses: 15-20% increase in radiative effects, taking into account Al windows; and, they are the “worst” kind (before scattering vertex, reduces asymmetry) 2.Perhaps a bit harder to manufacture 3.Maybe boiling performance worse, if bulk-dominated… We know 20 cm was good.

Cryotargets – request Requested identical 25 cm cells for PVDIS, HAPPEX-III: act as mutual spares in case of leaks; changeover of lH 2 to lD 2 on a loop is a couple of shifts; much better than replacing entire cell block on target ladder….. Can have three cells on cryotarget ladder now (was not the case for HAPPEx-II) Have one working 20 cm cell (hydrogen: thin-walled) from HAPPEx-II Requested: For new (25 cm) cells: - Side walls thickness: aim for  7 mils. - Entrance and exit windows: aim for  5 mils. - Important to have good measurement of window thicknesses, particularly in 1cm x 1cm region around the nominal central ray (allowing for  4 mm raster and a  5 mm offset of the beam axis) ASME issues seemed to have calmed down… Loop 125 cm "race-track" style (hydrogen) Loop 225 cm "race-track" style (deuterium) Loop 320 cm "race-track" style (existing HAPPEX-II/H cell)

Aluminum window thickness HAPPEX-1 15 cm “beer can” cell: HAPPEX-II 20 cm “racetrack” cell: Entrance window2.8 mil Exit window3.7 mil Side walls7.0 mil Entrance window7.0 mil Exit window2.8 mil Side walls5.4 mil Al background: (1.4  0.1) % Al background: (0.91  0.12) % (2004) (0.76  0.25) % (2005) Machining and measurement tolerances; chatter of bit … Need integrating mode data with variable density gas (target warming) to scale “xt” factor

Cryotargets – status ASME issues seemed to have calmed down (non-trivial!) Mike Seely resigned from Targets group (December 2008) I was late getting all specs to Targets group & getting info to Kees to justify $$ ( mea culpa) Dave Meekins has been busy with other targets (SANE, Qweak…) Cells not yet made, but still have adequate time: a few weeks needed for machining & a few weeks for testing Dave M.: time is “not yet a problem”

Solid Targets – HAPPEx-III & PVDIS - H 2 O cell (pointing angle measurement) - BeO viewer - Al dummy foils, located 25 cm apart (at the windows of the long racetrack cells) with 1.00 mm thickness - Standard C multi-foil optics target as we used in Carbon single foil target - Ta foil target (pointing angle measurement) - empty position Can’t run H 2 O cell when cryotarget cold (duuh…) Run optics/pointing measurements first with H 2 O cell installed, then break vacuum (all running at low current to this point), remove H 2 O cell, cool target. Estimate 2-day turnaround. Note: point angle measurement done at 1-pass beam energy, so there is also parallel overhead to restore 3- pass beam.

Solid Targets – PREx 1.Start with warm target: water cell & truncated target ladder (BeO, Ta, empty?) 2.Break vacuum, remove water cell (no high current on Pb yet) 3.Run with cold target and full solid target ladder. Top of stack (closest to cooling); one cryoloop only

Backup Slides (point angle details)

Pointing Angle Measurement - Important for Q 2 measurement - Use nuclear recoil technique as was done for HAPPEX-II/HAPPEX-He: Need targets with different recoil (i.e. different mass) to maximize precision Can use elastic scattering (M*=M) or inelastic to nuclear excited states (M*  M) At 1.18 GeV, 13.8°: E – E’ ¹H 41.3 MeV 9 Be 4.4 MeV 16 O 2.5 MeV 181 Ta 0.2 MeV Thus H 2 O target gives close to optimal performance; BeO possible, much less lever arm in E – E’, TiH has engineering problems. Dave Meekins designed water cell: 5 mm H 2 O, 2  1-mil thick steel windows. Note: cannot run with cryotargets; need to de-install water cell to install cryotargets (roughly 2-3 day turnaround)

Water cell results from HAPPEX-II Determined  to  0.01° in 2005 Note: Compared to 6°,  Q 2 /  is 42% as large at 13° and 24% as large at 20° scattering angles

Water cell for HAPPEX-III Will H 2 O target work at HAPPEX-III, PVDIS kinematics? H-II: E = 2.76 GeV  =6.1° Q 2 =0.085 GeV 2 q=1.47 fm -1 H-III: E =3.46 GeV  =13.8° Q 2 =0.625 GeV 2 q=4.0 fm -1 H-III (2-pass) E =2.32 GeV  =13.8° Q 2 =0.290 GeV 2 q=2.7 fm -1 (not feasible) H-III (1-pass) E =1.18 GeV  =13.8° Q 2 =0.077 GeV 2 q=1.41 fm -1  go to 1-pass beam for HAPPEX-III pointing measurement (cross sections about 30% of HAPPEX-II values) McCarthy and Sick, Nucl. Phys. A 150(1970)63 1-pass 2-pass

Water cell – excited 16 O states test T.N. Buti, PhD thesis (MIT, 1984); T.N. Buti et al. Phys. Rev. C 33(1986)755 2-pass 1-pass

Water cell for PVDIS PVDIS (1-pass) E =1.2 GeV  =12.9° q=1.36 fm -1 (no problem) “  =20° q=2.11 fm -1 (more of a challenge) at 20°: hydrogen elastic cross section down by factor 30 vs. H-II : ratio of elastic 16 O/hydrogen similar to H-II : 16 O excited states down relative to hydrogen elastic by factors of: 5 (3 1 - ), 8 (1 1 - ) and 20 (2 1 + ) Conclusion: Doable, but fits will have to rely on 16 O elastic and the (6.13 MeV) state entirely (I have not looked into 56 Fe peaks, don’t expect to see them)

Summary: pointing angle measurement 1.Water cell is best choice, if one can tolerate the changeover time (scheduling) Could use BeO, Ta, as less-invasive alternates to water cell… 2.Need to go to 1-pass beam for both HAPPEX-III and PVDIS  measurements. 3.PVDIS  measurement at 20° with water cell more challenging, but precision demands reduced…. However PVDIS proposal goal is a Q 2 contribution to error budget of 0.12% at  =20° which means  0.2 mrad (  0.01°), which matches HAPPEX-II precision…