Sphere Standards and Standard Spheres Dr. Richard Young Optronic Laboratories, Inc.

Slides:



Advertisements
Similar presentations
Richard Young Optronic Laboratories Kathleen Muray INPHORA
Advertisements

Dr. Richard Young Optronic Laboratories, Inc.
Instrumentation and Measurements Dr. Mohammad Kilani
1 Graphics CSCI 343, Fall 2013 Lecture 18 Lighting and Shading.
RET Optics Research Workshop ”Demos” Dr. Mike Nofziger Professor College of Optical Sciences University of Arizona Dr. Mike Nofziger 2013.
Grey Level Enhancement Contrast stretching Linear mapping Non-linear mapping Efficient implementation of mapping algorithms Design of classes to support.
OL 750 Diffuse Spectral Reflectance Measurement System
CE En 112 Engineering Drawing with CAD Application
Spectrometer Sam Valerio. Shows spectral distribution of a light source in the form of a graph. This specific one in the Imaging Science Center is called.
Absorbance spectroscopy
Source Measurement The most common measurements of sources include:  Radiance - Light emitted in a particular direction  Irradiance – Light falling onto.
Radiometry and the Radiometer
1 Angel: Interactive Computer Graphics 5E © Addison-Wesley 2009 Shading I.
University of New Mexico
OL 750 Measurement Systems
Copyright © 2009 Pearson Education, Inc. Chapter 32 Light: Reflection and Refraction.
Objectives Learn to shade objects so their images appear three- dimensional Learn to shade objects so their images appear three- dimensional Introduce.
Conceptual Design Review Senior Design
Radiance to Irradiance Conversion Training Level: Intermediate
Richard Young Richard Young Optronic Laboratories Kathleen Muray Kathleen Muray INPHORA Carolyn Jones Carolyn Jones CJ Enterprises.
Optics Can you believe what you see?. Optics Reflection: Light is retransmitted from or “bounces off” an object.
CRT MONITOR cathode-ray tube
Classification of Instruments :
Quality Assurance in the clinical laboratory
lecture 2, linear imaging systems Linear Imaging Systems Example: The Pinhole camera Outline  General goals, definitions  Linear Imaging Systems.
CS 480/680 Computer Graphics Shading I Dr. Frederick C Harris, Jr.
 Sometimes when you look out a window, you see what is outside as well as your own reflection  This is because some light reflects and some light refracts.
Dynamic Presentation of Key Concepts Module 2 – Part 3 Meters Filename: DPKC_Mod02_Part03.ppt.
CRT MONITOR cathode-ray tube
Set-up for Levy Flight of Photons in Resonant Atomic Vapor Danielle Citro (SUNY Oswego), Adailton Feliciano (UFPB), Martine Chevrollier (UFPB), Marcos.
Physics 1809 Optics 3: Physical Optics Purpose of this Minilab Experiment with and learn about - Light intensity - Polarization - Diffraction - Interference.
1 Components of Optical Instruments, Cont… Lecture 7.
Review of ILC results for fritted glass Jacob C. Jonsson Windows and Daylighting Program Windows and Envelope Materials Group Building Technology and Urban.
Errors in Measurement Muhajir Ab. Rahim
Modelling and Simulation Types of Texture Mapping.
Motivation Measurements of Radiant Flux  Physical Properties of Complex Systems Required Scientific Accuracy  State of the Art Measurements International,
Dr. Andrew Tomasch 2405 Randall Lab
Dr. Richard Young Optronic Laboratories, Inc..  Uncertainty budgets are a growing requirement of measurements.  Multiple measurements are generally.
Transmittance Measurement Presented by Dr. Richard Young VP of Marketing & Science Optronic Laboratories, Inc.
LECTURER PROF.Dr. DEMIR BAYKA AUTOMOTIVE ENGINEERING LABORATORY I.
The Future of NVIS Display Measurement ALI Advanced Seminar, 2006Optronic Laboratories Dr. Richard Young Optronic Laboratories, Inc.
1 Atomic Absorption Spectroscopy Lecture Emission in Flames There can be significant amounts of emission produced in flames due to presence of flame.
1 Atomic Absorption Spectroscopy Lecture Performance Characteristics of Electrothermal Atomizers Electrothermal atomization is the technique of.
Multimedia Data Introduction to Image Processing Dr Sandra I. Woolley Electronic, Electrical.
Detector Response Measurements Presented by Dr. Richard Young VP of Marketing & Science Optronic Laboratories, Inc.
UV-Vis Absorption Spectroscopy
Optronic Laboratories Inc. OL Series 750 Automated Spectroradiometric Measurement System Optronic Laboratories Inc. OL Series 750 Automated Spectroradiometric.
Simulations of the double funnel construction for LET. Comparison with a single funnel The aim was to optimise the double funnel configuration to give.
Simple Double Beam Spectrometer
Optronic Laboratories, Inc. A Gooch & Housego Company Lumesphere Plus TM Ease of use, even by inexperienced operators. Controller incorporates precise.
DECam Daily Flatfield Calibration DECam calibration workshop, TAMU April 20 th, 2009 Jean-Philippe Rheault, Texas A&M University.
Light Reflection and Mirrors.  The Law of Reflection  When a wave traveling in two dimensions encounters a barrier, the angle of incidence is equal.
OL 750 Measurement Systems OL 750 Measurement Systems Optronic Laboratories, Inc.
CS TC 22 CT Basics CT Principle Preprocessing. 2 CT Basics CT principle preprocessing CS TC 22 Blockdiagram image processor.
Introduction to Thermal Radiation
The law of reflection: The law of refraction: Image formation
1 Teaching Innovation - Entrepreneurial - Global The Centre for Technology enabled Teaching & Learning D M I E T R, Wardha DTEL DTEL (Department for Technology.
OpenGL Shading. 2 Objectives Learn to shade objects so their images appear three-dimensional Introduce the types of light-material interactions Build.
The Microscope th Grade Science. Microscope A microscope is an instrument for viewing objects that are too small to be seen easily by the naked.
Reflection and Refraction of Light From “College Physics” Serway and Faughn with modifications.
Geometrical Optics.
Comparison Between AM and FM Reception. 21/06/20162 FM Receiver.
Digital Light Sources First introduced in 2001.
Quality Assurance in the clinical laboratory
Absorbance spectroscopy
Detective Quantum Efficiency Preliminary Design Review
High Accuracy UV-VIS Spectroradiometer ( nm)
OL 750 Measurement Systems
8.5 Modulation of Signals basic idea and goals
OL 750 Spectroradiometer & Linear Spectral Transmission Measurements
Presentation transcript:

Sphere Standards and Standard Spheres Dr. Richard Young Optronic Laboratories, Inc.

Sphere Applications  Standard Spheres  Total flux measurements All the light from a lamp is measured  Irradiance measurements Light at a surface is measured  Sphere standards  Large uniform source is used for calibration of instruments

Total Flux  An integrating sphere has several interesting properties:  Any part of the sphere surface “sees” all other parts of the sphere surface equally. This means a detector at any point on the surface can measure the total power in the entire sphere.  Reflections from the sphere wall add to the lamp power, giving more power inside the sphere than the lamp is generating.

Total Flux  The lamp is placed in the center.  A baffle prevents direct light hitting the detector.  The sphere walls and baffle are highly reflective. Lamp Baffle Detector

Total Flux  Light from the lamp hits the sphere wall equally in almost all directions…

Total Flux  Light from the lamp hits the sphere wall equally in almost all directions…  But there are variations in sphere response. Shadow area Partial Shadow area

Total Flux  In these shadow areas, the “first strike” (light directly from the lamp) is not fully measured.  A sphere cannot have PERFECT response. Shadow area Partial Shadow area

Total Flux  Although perfect response is not attainable with this design, practical spheres can come very close.  How close they come depends on attention to small details of design. “An expert is someone who knows some of the worst mistakes that can be made in his subject and how to avoid them.” - W. Heisenberg

Total Flux  Response is best viewed on a radar graph.  Response varies with sphere size and reflectivity.  If a reflectivity of 95% is used… 0.5 m sphere

Total Flux  Response is best viewed on a radar graph.  Response varies with sphere size and reflectivity.  If a reflectivity of 95% is used… 1.0 m sphere

Total Flux  Response is best viewed on a radar graph.  Response varies with sphere size and reflectivity.  If a reflectivity of 95% is used… 2.0 m sphere

Total Flux  A reflectivity of 98% or more is more common for US manufactured spheres.

Total Flux  Some European standards recommend 80% reflectivity.  But this gives large geometric errors. Note the higher response in places

Total Flux  This high response is caused by reflections from the detector side of the baffle.

Total Flux  This high response is caused by reflections from the detector side of the baffle.  It is present in all spheres, but some are much worse than others.

Total Flux  All the prior sphere responses had one thing in common:  The detector had a cosine collector on it.  If we remove the cosine collector…  The response of even the best sphere is destroyed

Total Flux  Many Sources are highly directional Fluorescent Lamps

Total Flux  Many Sources are highly directional LEDs

Total Flux  A sphere has areas of uniform response (green).  And non-uniform areas (red).  If the source is highly directional, it should be pointed at a green area for the best results.

Total Flux  The green area is bigger for larger spheres.  The red area is bigger for larger baffles.

Total Flux  Geometrically, the highest accuracies are obtained by orienting lamps so the maximum output is directed at areas of uniform response.  Highly reflective coatings give much lower geometrical errors, regardless of orientation, than less reflective coatings.

Total Flux However,  Anything placed inside spheres, including lamps, holders, sockets and cables, can absorb light and change the sphere throughput.  The higher the reflectivity of the sphere, the bigger the change to throughput when something is placed inside.

Total Flux Here, the effective reflectivity is changed by just 0.25%

Total Flux  This example is for a black spherical object in the center of the sphere.  Actual changes will depend on the object’s reflectance, shape and position in the sphere, and can be larger than shown.

Total Flux  The lamp used in calibration and the lamp to be measured are rarely the same.  Different changes in throughput between these lamps will mean results will be wrong unless throughput changes are also measured.

Total Flux  An auxiliary lamp, which is housed permanently in the sphere, is used to measure changes in throughput. Auxiliary Lamp

Total Flux  The auxiliary lamp is powered up while the standard or test lamp is in the sphere.  But not switched on.  The ratio of signals is the change in throughput.  This is part of the calibration procedure. Auxiliary Lamp

Total Flux  Good total flux measurements require:  A large high reflectivity sphere.  Small, well designed, baffles.  A cosine collection detector at the sphere wall.  An auxiliary lamp.

Total Flux  It also helps to have:  Uniform measurement procedures. e.g. keep a constant time between powering up a lamp and measuring it.  Dedicated software to guide the user through calibration and measurement.  Accurate power supplies for lamps.  NIST traceable calibration lamps.  “Heisenberg” experts for support.

Irradiance  Irradiance is the light flux falling onto a surface.  The light can come from any direction, and may be from multiple sources.  The total light hitting the surface must be measured.

Irradiance  The apparent area of a surface changes with angle.  This is called the cosine law.  A measurement device that follows the cosine law is called a cosine collector.  This is called the cosine law.  A measurement device that follows the cosine law is called a cosine collector.

Irradiance  An integrating sphere with an input port makes an excellent cosine collector…  Provided certain design rules are followed.

Irradiance  The first rule is:  If light does not obey the cosine law when entering the sphere, there is little the sphere can do to compensate.  This is easier said than done because a sphere has 2 sides – the inside and the outside. Magnify

Irradiance  The first rule is:  If light does not obey the cosine law when entering the sphere, there is little the sphere can do to compensate.  This is easier said than done because a sphere has 2 sides – the inside and the outside. Inside Outside

Irradiance  This creates a “tube” effect that stops some of the light at higher angles entering the sphere directly. Some light is blocked

Irradiance  So, as the angle is changed, the cosine response gets worse and worse. A circle obeys the cosine law A tube does not obey the cosine law

Irradiance  The answer is simple.  Make the outside of the sphere flat to meet the inside at the port. Thus eliminating the “tube”.

Irradiance  So now the light enters the sphere obeying the cosine law. Rule #2: add a baffle to prevent direct light hitting the detector

Irradiance  So now the light enters the sphere obeying the cosine law. Rule #3: the detector must also obey the cosine law And the sphere can be used for irradiance measurements

Sphere Standards  If we replace the detector with a lamp, this sphere is now a source instead of a collection optic.

Sphere Standards  The uniformity of the sphere output depends on the way the light enters the sphere.  Cosine diffusers at the input give uniform output but throw away a lot of light.

Sphere Standards  It is difficult to achieve high light levels and good uniformity.  Especially if the output level also needs to be variable.  One option is to change the design.

Sphere Standards  By making sure the input light only hits the baffle, the output light is randomized.  If the input light level varies, so does the output.  To track changes we add a monitor.

Sphere Standards  This monitor is baffled so it only sees the output light, not the input.  So it can be calibrated to show the output levels directly.

Sphere Standards  The amount of light entering the sphere can be controlled by varying a slit.

Sphere Standards  Non-imaging collection mirrors can increase the light intensity.  Provided the beam is approximately uniform and over- fills the largest slit.

Sphere Standards  Slits can be linear (1D)  The width varies  Or area (2D)  The width and height vary together

Sphere Standards  A 2D slit provides better control over a wide range of levels than a linear (1D) slit. With a 1D slit, the output drops almost vertically at small slit widths

Sphere Standards  Expressed another way, the slit resolution needed to change the output by 1%… At a resolution of 10 -5, the 1D slit cannot control the output below below 3 decades 2D slits can give up to 1000 times better control than 1D slits 2D slits are clearly superior for high dynamic range sources

Sphere Standards  By careful design and material selection, one can achieve:  High uniformity of output  High maximum levels of output  Very stable operation  6 or more decades of light level adjustment  Direct reading of the output  Easy adjustability and setting to any level  An almost constant spectrum at all levels

Sphere Standards and Standard Spheres Dr. Richard Young Optronic Laboratories, Inc.