Y Z Bai, H Yin, L Liu, D Y Tan, Z B Zhou Center for Gravitational Experiments, School of Physics, Huazhong Univ. of Science &

Slides:



Advertisements
Similar presentations
QUICK QUIZ 15.1 (end of section 15.2)
Advertisements

PLANAR KINETICS OF A RIGID BODY: CONSERVATION OF ENERGY
1 Test Mass Suspensions for AIGO Ben Lee The University of Western Australia.
MEMS Gyroscope with Electrostatic Comb Actuation and Differential Capacitance Sensing Haifeng Dong, Zheng Yao, Advisor: Xingguo Xiong Department of Electrical.
An Introduction to Electrostatic Actuator
Koji Arai – LIGO Laboratory / Caltech LIGO-G v2.
Lecture 2 Free Vibration of Single Degree of Freedom Systems
Conservation of Energy Energy is Conserved!. The total energy (in all forms) in a “closed” system remains constant The total energy (in all forms) in.
Nonstationary electrical charge distribution on the fused silica bifilar pendulum and its effect on the mechanical Q-factor V.P. Mitrofanov, L.G. Prokhorov,
OEIC LAB National Cheng Kung University 1 Ching-Ting Lee Institute of Microelectronics, Department of Electrical Engineering, National Cheng Kung University.
Jessica Gifford | August 25, 2010 | Int-Reu.  Gravity Waves and Lisa  Torsion Pendulum  Old Electron Gun Measurements  New motor  Photocurrent measurements:
Can the CNB be detected by a torsion balance? B. Heckel, Univ. of Washington.
Extra Dimensions, Dark Energy and the Gravitational Inverse-Square Law ? Liam J. Furniss, Humboldt State University.
Louis J. Rubbo, Neil J. Cornish, and Olivier Poujade Support for this project was provided by the NASA EPSCoR program.
Phy 212: General Physics II Chapter 15: Oscillations Lecture Notes.
Dressed state amplification by a superconducting qubit E. Il‘ichev, Outline Introduction: Qubit-resonator system Parametric amplification Quantum amplifier.
TeV Particle Astrophysics August 2006 Caltech Australian National University Universitat Hannover/AEI LIGO Scientific Collaboration MIT Corbitt, Goda,
Generation of squeezed states using radiation pressure effects David Ottaway – for Nergis Mavalvala Australia-Italy Workshop October 2005.
Recent Developments toward Sub-Quantum-Noise-Limited Gravitational-wave Interferometers Nergis Mavalvala Aspen January 2005 LIGO-G R.
Current progress of developing Inter-satellite laser interferometry for Space Advanced Gravity Measurements Hsien-Chi Yeh School of Physics Huazhong University.
Experimental Study of the Machian Mass Fluctuation Effect Using a µN Thrust Balance N. Buldrini, K. Marhold, B. Seifert and M. Tajmar Space Propulsion.
Current Progress of Development of Laser Interferometry for LISA-type Mission in China Hsien-Chi Yeh School of Physics Huazhong University of Science &
Quantum Noise Measurements at the ANU Sheon Chua, Michael Stefszky, Conor Mow-Lowry, Sheila Dwyer, Ben Buchler, Ping Koy Lam, Daniel Shaddock, and David.
GWADW 2010 in Kyoto, May 19, Development for Observation and Reduction of Radiation Pressure Noise T. Mori, S. Ballmer, K. Agatsuma, S. Sakata,
LISA STUDIES AT THE UNIVERSITY OF COLORADO Michael J. Nickerson, Ellery B. Ames, John L. Hall, and Peter L. Bender JILA, University of Colorado and NIST,
UW LISA Torsion Balance Experiment Scott E Pollack with Stephan Schlamminger, Charlie Hagedorn, & Jens Gundlach Center for Experimental Nuclear Physics.
Lecture 5 Method of images Energy stored in an electric field Principle of virtual work 1.
Z B Zhou, Y Z Bai, L Liu, D Y Tan, H Yin Center for Gravitational Experiments, School of Physics, Huazhong University of Science.
Inertial Sensor and Its Application for Space Fundamental Experiments Ze-Bing Zhou ( 周泽兵 ), Jun Luo ( 罗俊 ) Center for Gravitational.
G O D D A R D S P A C E F L I G H T C E N T E R Surface Potential Measurements with the LISA Kelvin Probe Jordan Camp LIGO/LISA Charging Workshop July.
SQL Related Experiments at the ANU Conor Mow-Lowry, G de Vine, K MacKenzie, B Sheard, Dr D Shaddock, Dr B Buchler, Dr M Gray, Dr PK Lam, Prof. David McClelland.
Creative Research Initiatives Seoul National University Center for Near-field Atom-Photon Technology - Near Field Scanning Optical Microscopy - Electrostatic.
New Low-Frequency GW Detector with Superconducting Instrumentation
By Francesco Maddalena 500 nm. 1. Introduction To uphold Moore’s Law in the future a new generation of devices that fully operate in the “quantum realm”
Sub-Millimeter Tests of the Gravitational Inverse-Square Law C.D. Hoyle University of Washington In collaboration with: E.G. Adelberger J.H. Gundlach B.R.
PeTeR: a hardware simulator for LISA PF TM-GRS system 23/05/ th LISA Symposium May 2012, BnF Paris L. Marconi and R. Stanga Università degli.
Experimental results on the fluctuations in two out of equilibrium systems S. Joubaud, P.Jop, A. Petrossyan and S.C. Laboratoire de Physique, ENS de Lyon,
H = distance from the axis of rotation to the center of mass Theoretical Derivation of the Period of a Physical Pendulum Period of a Physical Pendulum.
Cold damping of fused silica suspension violin modes V.P.Mitrofanov, K.V.Tokmakov Moscow State University G Z.
Masaki Ando, Akiteru Takamori, Kimio Tsubono Department of Physics, University of Tokyo Earthquake Research Institute, University of Tokyo 1st International.
Effect of Charging on Thermal Noise Gregory Harry Massachusetts Institute of Technology - Core Optics and Suspensions Working Groups - March 19, 2004 –
D. Ugolini, Joint APS-AAPT Meeting at UT-Arlington, October 2006 Developing a Capacitive Probe for Measuring Charging Effects on In-Vacuum Optics Dennis.
Electrostatic force noise and free-fall for LISA Bill Weber Università di Trento Ludovico Carbone, Antonella Cavalleri, Giacomo Ciani, Rita Dolesi, Mauro.
Investigation of effects associated with electrical charging of fused silica test mass V. Mitrofanov, L. Prokhorov, K. Tokmakov Moscow State University.
Uniform Circular Motion Side View of Uniform Circular Motion.
Gravitational Wave Observatories By: Matthew Fournier.
Advanced LIGO UK 1 LIGO-G Z Development issues for the UK Advanced LIGO project Caroline Cantley Glasgow University for the UK Advanced LIGO Team.
External forces from heat links in cryogenic suspensions D1, ICRR, Univ. Tokyo Takanori Sekiguchi.
Torsion Pendulum Dual Oscillator (TorPeDO) David McManus, Min Jet Yap, Robert Ward, Bram Slagmolen, Daniel Shaddock, David McClelland.
Space Gravitational Wave Antenna DECIGO Project 3rd TAMA Symposium February 7, Institute for Cosmic Ray Research, Japan Seiji Kawamura National.
Measurement of coating mechanical loss Junko Katayama, K.Craig, K.Yamamoto, M.Ohashi ICRR 0.
1 10. Harmonic oscillator Simple harmonic motion Harmonic oscillator is an example of periodic motion, where the displacement of a particle from.
Date of download: 6/23/2016 Copyright © 2016 SPIE. All rights reserved. A schematic design of the all-dielectric polymer waveguide E-field sensor (a).
ET-ILIAS_GWA joint meeting, Nov Henning Rehbein Detuned signal-recycling interferometer unstableresonance worsesensitivity enhancedsensitivity.
Metallurgha.ir1. Lecture 5 Advanced Topics II Signal, Noise and Bandwidth. Fundamental Limitations of force measurement metallurgha.ir2.
ELEC 3105 Basic EM and Power Engineering
Mechanical Vibrations
Current and future ground-based gravitational-wave detectors
Mechanical Loss in Silica substrates
First clues on ET payload sensing and control
10. Harmonic oscillator Simple harmonic motion
Nergis Mavalvala Aspen January 2005
Generation of squeezed states using radiation pressure effects
Quantum effects in Gravitational-wave Interferometers
Problem No.1 Invent yourself
Test Mass Suspensions for AIGO
A mass m = 2.0 kg is attached to a spring having a force constant k = 990 N/m as in the figure. The mass is displaced from its equilibrium position.
Precision Beam Monitors for COSY Jülich
Differential Equations
Advanced Optical Sensing
Presentation transcript:

Y Z Bai, H Yin, L Liu, D Y Tan, Z B Zhou Center for Gravitational Experiments, School of Physics, Huazhong Univ. of Science & Technology, Wuhan, China An electrostatic torsion pendulum aiming at improving the angular detection sensitivity without increasing torque noise floor is presented. Theoretical analysis shows that it could be used to release requirement of angular measurement, and is useful for gravitational experiments with much higher precision requirement. In this poster, the principle of the electrostatic pendulum system is introduced, and its sensitivity and noise analysis are presented. i. Introduction A typical torsion balance is very sensitive to probe force or torque which induced by weak signals, and its resolution is limited by the thermal noise of the pendulum and the readout noise, namely, the angular detection level. For more information: Improving the angular detection sensitivity of a torsion pendulum by an electrostatic spring The torsion pendulum plays a paramount role in the field of precision measurement and gravitational experiments due to its high-precision sensitivity. Such as investigating the performance of a gravitational sensor and charge management for LISA. ii. A Typical Torsion Balance and Its Potential Sensitivity The torsion balance is set in a high vacuum chamber, where viscous damping can be ignored. The motion equation of the system in this case can be written as where φ is the structure loss angle, τ th is a random force with a white spectral density, and is presented as follows The power spectrum of the minimum detectable torque can be obtained as follows iii. Electrostatic Torsion Pendulum The schematic of the electrostatic pendulum is shown in Figure 2, where one pair of electrodes are added in sided of the test mass, where d e is the distance between the test mass each electrode, l e is the vertical distance from the centre of the electrode to the fiber, V f is the voltage applied on the electrodes to adjust the performance the system, and S e =a xe a ye is the area of each electrode. The power spectrum of the thermal fluctuation of the electrostatic pendulum, θ th,e 2 Resolution of electrostatic torsion pendulum can be given by Compare the electrostatic torsion pendulum with the typical balance as follows at low frequency: ω<<ω 0 at high frequency: ω>>ω 0 iv. Example The torsion pendulum presented by Washington University to study the charge effects for gravitational-wave is used as an example to be discussed, whose main parameters are listed in Table I, and a couple electrodes are added as add additional electrostatic spring, whose parameters are listed in Table II. The motion equation of the electrostatic torsion pendulum is given by Assuming the angle measurement noise is 5  ( /f) 1/2 rad/Hz 1/2. Resolutions of the torsion pendulum system with or without an electrostatic spring are shown in Figure 3. The electrostatic noise of electrostatic pendulum induced by fluctuation of voltage 10 μV/Hz 1/2 is within Nm/Hz 1/2, which can be neglected. If the requirement of torque detection is 5  Nm/Hz 1/2 above 0.1mHz, the requirement of the angle measurement device is shown in Figure 4. Conclusions: The electrostatic spring can release the requirement of the angular detection of a torsion pendulum, which is very important for the much higher precise torsion pendulum experiments, such as to investigate the effects of a test mass for LISA and advanced LISA projects. Ground testing for LISA (University of Trento) Charge management (University of Washington) Figure 1 Figure 2(a) Figure 2(b) Top view Figure 3 Figure 4 where τ e is the electrostatic torque, and τ e,n is the random torque induced by applied voltage fluctuations. References: 1.M Hueller, A Cavalleri et al, Torsion pendulum facility for ground testing of gravitational sensors for LISA, Class. Quantum Grav. 19 (2002) S.E.Pollack, M.D.Turner, S.Schlamminger, et al, Charge Management for gravitational-wave observatories using UV LEDs, Phys. Rev. D. 81, (R)(2010). 3.Q. L. Wang, H. C. Yeh, Z. B. Zhou et al, Improving the sensitivity of a torsion pendulum by using an optical spring method, Phy. Rev. A, 80, (2009)