Final Year Project A study on the human body parameters influencing blood flow during Neuromuscular electrical stimulation on the lower limbs Patrick Moran.

Slides:



Advertisements
Similar presentations
Basic Principles of Electricity Electromagnetic Spectrum b Electrical Stimulating Currents Commercial Radio and Television Shortwave Diathermy Microwave.
Advertisements

Principles of Biomechanics
There are three major types of Blood flow Doppler patterns: 1) Continuous Wave 2) Pulse Wave 3) Color Flow DOPPLER ULTRASOUND.
The Use of Surface Electromyography in Biomechanics by Carlo De Luca
Principles of Technology Waxahachie High School Ratein Electrical Systems PIC Chapter 3.3 Ratein Electrical Systems PIC Chapter 3.3 PT TEKS.
Electrophysiologic Measures of Ulnar Sensory Nerve Function: Electrophysiologic Measures of Ulnar Sensory Nerve Function: Reference Values and Reliability.
Neuromuscular Adaptations During the Acquisition of Muscle Strength, Power and Motor Tasks Toshio Moritani.
Chapter 6 Improving Muscular Strength & Endurance
This article and any supplementary material should be cited as follows: Bickel CS, Gregory CM, Azuero A. Matching initial torque with different stimulation.
LINEAR REGRESSION: Evaluating Regression Models Overview Assumptions for Linear Regression Evaluating a Regression Model.
LINEAR REGRESSION: Evaluating Regression Models. Overview Assumptions for Linear Regression Evaluating a Regression Model.
Giggins OM, Coughlan GF, Caulfield BM, Crowe LM Stim XDP Research Group, Institute for Sport and Health, University College Dublin, Dublin 4, Ireland.
Psy 552 Ergonomics & Biomechanics Lecture 5. Energy for Muscles  Energy for muscle contractions if provided for by the breaking down of adenosine tri-
1 Regression and Calibration EPP 245 Statistical Analysis of Laboratory Data.
Ground Motion Parameters Measured by triaxial accelerographs 2 orthogonal horizontal components 1 vertical component Digitized to time step of
Development of an Ultrasound Lab Laura Wade April 4 th Z.
Pacemaker & its Classification
Principles of Electrical Stimulation. Current Types  Direct Current  Alternating Current  Pulsed Current.
Therapeutic exercises and modalities Lecture 20
Previous hamstring strain injury reduces knee flexor strength and biceps femoris activation Opar, David 1# ; Dear, Nuala 1 ; Timmins, Ryan 1 ; Williams,
Resident Categorical Course
Muscle Fitness ..
Preventing Injuries through Fitness Chapter 4. Objectives Be able to describe the different conditioning seasons Be able to list and describe 3 different.
The Thermal Effects of Pulsed Shortwave Diathermy on Electromyography and Mechanomyography Sarah Marek November 17, 2004.
Display of Motion & Doppler Ultrasound
Human Subjects in fMRI Research Credits: Robert Savoy, Ph.D. Franz Schmitt, Ph.D.
The Impact of Circulation Access in Allogeneic Peripheral Blood Stem Cell Harvest Shang-Hsien Yang1, Tso-Fu Wang2,3, Shu-Hui Wen4, Sung-Chao Chu3, Ruey-Ho.
Do Now 1. Name the 5 Physical Fitness Tests you did in the fall. 1. Name the 5 Physical Fitness Tests you did in the fall. 2. What did these tests measure?
Effects of Neuromuscular Electrical Stimulation on Ankle Swelling in the Early Period After Ankle Sprain Ivy OW Man, Matthew Morrissey, Jozef Cywinski.
Body Composition Body composition refers to the relative amounts of lean body mass (muscle, bone, water, organs, etc) and fat in the body Body composition.
One-arm reach (heels down example) Two-arm reach (heels up example) Conclusions Highest reliability for all age groups was in the toe-to-finger method.
Ultrasound 10cm 2 Ultrasound (US) Therapeutic ultrasound –Uses acoustic energy, delivered at high frequencies for therapeutic purposes Electrical current.
Pulse Pressure: Difference between the systolic and diastolic measurements (Remember systolic is the number on the top of the ratio) Ex: 120/80 means that.
Electric Currents Part 2 By B. Nelson. Clinical Applications of Electric Current Muscle contraction of innervated muscles Muscle contraction of denervated.
Rehabilitation With Functional Electronic Stimulation
USING THERAPEUTIC MODALITIES Electrotherapy. ELECTROTHERAPY Electrical current String of electrons that pass along a conductor Intensity of current =
Korea Univ. Col of Healthscience Depart.of Physical Therapy Eun hye Kim, PT, Ph.D course Phototherapy & Electrotherapy (1)
Date of download: 5/28/2016 Copyright © 2016 American Medical Association. All rights reserved. From: Increased Metabolic Muscle Fatigue Is Caused by Some.
Unit – 2 – FARADIC CURRENT / FARADISM
CS 2016 Introduction to Practical 5 Nerve Conduction & Muscle Response Christian Stricker ANUMS/JCSMR - ANU
SINUSOIDAL CURRENT Dr. Amal Abd El Baky, LOGANATHAN CHANDRASEKAR 353 RHPT – 1435 – 1436H – 1 st SEM.
Subjects: 53 healthy subjects (28 M, 25 F), between the ages of years (mean age = 28.4 ± 8.1 years). All subjects had no history of musculoskeletal,
Validation of Methods of Estimating % Body Fat. How do you validate these techniques? There can be no direct validation – Measure subjects with technique.
This article and any supplementary material should be cited as follows: Carty A, McCormack K, Coughlan GF, Crowe L, Caulfield B. Alterations in body composition.
UNIT III DC Choppers.
Personal Fitness Lesson #3
Normal Arterial Anatomy of the Lower Limb and Positioning for Measurement of Ankle Systolic Pressure Used for Determining the Ankle Branchial Index (ABI)
Ultrasound.
FORTUNA SCIENTES IUVAT
Chapter 1: The Scientific Rationale for Integrated Training
Validation of Methods of Estimating % Body Fat
The Measurement of Motor Performance
Physiotherapy rehabilitation for people with spinal cord injuries
Neurophysiological Basis of Movement
Evaluation of Transcutaneous Stimulation of the Thoraco-Lumbo Conus
Validation of Methods of Estimating % Body Fat
NASM: Chapter 6 Fitness Assessments.
Validation of Methods of Estimating % Body Fat
Electrical Stimulation
Lower Thoracic Spinal Cord Stimulation to Restore Cough in Patients With Spinal Cord Injury: Results of a National Institutes of Health–Sponsored Clinical.
Muscle Intelligence technology
Motor Recovery after Spinal Cord Injury Enhanced by Strengthening Corticospinal Synaptic Transmission  Karen L. Bunday, Monica A. Perez  Current Biology 
Human Subjects in fMRI Research
Electrical stimulation: Can it increase muscle strength and reverse osteopenia in spinal cord injured individuals?  Marc Bélanger, PhD, Richard B. Stein,
Sheila M Schindler-Ivens, PhD, PT, Richard K Shields, PhD, PT 
Stimulation of Shank Muscles During Functional Electrical Stimulation Cycling Increases Ankle Excursion in Individuals With Spinal Cord Injury  Ché Fornusek,
The Effectiveness of Progressively Increasing Stimulation Frequency and Intensity to Maintain Paralyzed Muscle Force During Repetitive Activation in Persons.
Characterization of the human quadriceps muscle in active elders
Comparisons to Isokinetic Strength
Gabor Libertiny, FRCS, Linda Hands, MS, FRCS 
Presentation transcript:

Final Year Project A study on the human body parameters influencing blood flow during Neuromuscular electrical stimulation on the lower limbs Patrick Moran 4th Electronic Eng.

Project Objectives To examine if the effectiveness of Neuromuscular Electrical Stimulation is influenced by the following: Anthropometrics of the calf Muscle Body mass Index Body Fat Muscle Volume Isometric Ankle Torque And to establish any relationships that may exist

Neuromuscular Electrical Stimulation What is Neuromuscular Electrical Stimulation? Application of electrical stimuli to a group of muscles to trigger an artificial muscle contraction Where is Neuromuscular Electrical Stimulation used? • Correction of drop foot • Muscle strengthening • Mobilisation of spinal cord injury • Maintaining range of motion in immobilised subjects

Neuromuscular Electrical stimulation in this study Surface Neuromuscular electrical stimulation shall be used in this study. Source of stimulation would be The Dou – STIM Stimulation parameters • Max Voltage (100%) = 78Volts • Ramp up time = 1 second • On Time = 1 second • Ramp Down Time = 500 milliseconds • Frequency = 36 Hertz • Pulse Interval = 100μseconds • Pulse Width = 100 μseconds .

About the Study Electrodes Placed on calf muscle Blood flow examined from popliteal Vein using doppler ultrasound scanner Stimulation was started at 25% and incremented in steps of 5%, until the subject stated that they no longer found it comfortable Ethics Application - NUI Galway Research Ethics Committee

Results The subjects were examined individually first. The following relationships were established while looking at the subject’s results as individuals. • Stimulation Intensity Vs Venous Volume Flow • Stimulation Intensity Vs Isometric Ankle Torque • Isometric Ankle Torque Vs Venous Volume Flow • Stimulation Intensity Vs Peak Venous Velocity Then the results were looked at from a group perspective. It was hoped to establish any relationships that may exist between the correlations obtained from the individual results and the anthropometrics of the lower limbs or the subject’s body mass index. A p value of < 0.05 was considered significant in all analyses.

Stimulation Intensity Vs Venous Volume Flow The correlation values ranged from 0.911 ‐ 0.997. The regression calculations ranged from 0.83 ‐ 0.995. No p - value was greater than 0.05

Stimulation Intensity Vs Ankle Torque The correlation values ranged from 0.911 ‐ 0.997. The regression calculations ranged from 0.774 ‐ 0.971. No p - value was greater than 0.05

Venous Volume Flow Vs Ankle Torque The correlation values ranged from 0.894 ‐ 0.996. The covariance's calculated were all positive indicating a relationship. No p - value was greater than 0.05

Stimulation Intensity Vs Peak Venous Velocity The correlation values ranged from 0.911 ‐ 0.997. The regression calculations ranged from 0.774 ‐ 0.971. No p - value was greater than 0.05

Group results

Conclusion The effects of NMES on blood flow were proven, very significant relationships were found between: • Stimulation Intensity Vs Venous Volume Flow • Stimulation Intensity Vs Isometric Ankle Torque • Isometric Ankle Torque Vs Venous Volume Flow • Stimulation Intensity Vs Peak Venous Flow The fact that no relationships were found between these and the human body parameters can be put down to a small sample size and possibly human error.

Questions