Klinik und Poliklinik für Augenheilkunde All authors have no financial interest in the subject matter of this poster. R. Khoramnia, J. P. Salgado, C.P.

Slides:



Advertisements
Similar presentations
Discrepancy Between Scheimpflug and Placido-Based Topographies and Correlation with Astigmatism After Scheimpflug Topography-Guided LASIK Mohamed Abou.
Advertisements

Description of a novel “Lock-and-key” configuration for femtosecond assisted keratoplasty A Iovieno; V Chowdhury; V Maurino Moorfields Eye Hospital, NHS.
Swept Source Optical Coherence Tomography for Evaluation of Posterior Corneal Changes after Refractive Surgery Dr. Tommy Chung Yan Chan Dr. Vishal Jhanji.
Comparison between Dynamic contour tonometry, Goldmann applanation tonometry and Ehlers-corrected Goldmann applanation tonometry in eyes after Laser In.
Comparison of corneal astigmatism measured with 3 devices Mariko Shirayama, M.D, Li Wang, M.D, PhD, Mitchell P. Weikert, M.D, Douglas D. Koch, M.D. Cullen.
Eugene Ng, Arthur B. Cummings, Patrick P. Collins, Alexander V. Goncharov, Diana Bogusevschi, Chris Dainty, Michael C. Mrochen. The authors of this paper.
E-Poster ALC Canedo, MD 2010 Rio de Janeiro CornealTomograhyandBiomechanics Study Group Study Group Comparative Study of Corneal Biomechanical Properties.
Purpose We studied the interdevice agreement of three systems in the different measurements of the corneal and anterior segment biometric parameters. The.
David Zadok MD, Isaac Avni MD
Variations in corneal biomechanical parameters and central corneal thickness during the menstrual cycle. David Zadok, MD, Yakov Goldich, MD, Yaniv Barkana,
Dept. of Ophthalmology, Friedrich-Alexander University Erlangen-Nuremberg, Erlangen, Germany. Outcome after big-bubble deep anterior lamellar keratoplasty.
Comparison of Orbscan and Ultrasound Pachymetry Measurements Faik Orucov, MD, Abraham Solomon, MD,Ziv Caspi, David Landau, MD, Eyal Strassman, MD, and.
Evaluation of Corneal Parameters and Spherical Aberration After DSAEK Measured with Pentacam System Orkun Muftuoglu, Pawan Prasher, R. Wayne Bowman, Steven.
TRANSPALPEBRAL TONOMETER APPLICATION DURING INTRAOCULAR PRESSURE EVALUATION IN THE PATIENTS WITH REFRACTION ANOMALY BEFORE AND AFTER KERATOPHOTOREFRACTIVE.
Evaluation of Interface Reflectivity and Corneal Aberrations following DSAEK Hamid Khakshoor, MD Professor of Ophthalmology Mashhad University of Medical.
Glaucoma Screening With a New Non-Contact Air Impulse Tonometer Pandelis A. Papadopoulos,1,2, Dimitrios P. Bessinis 3, Alexandros A. Papadopoulos 1, Konstantinos.
Relationship between Pachymetry and Ocular Response Analyzer Measurements Alejandro Rivera MD.
The authors have no financial interest in the subject matter of this poster Yinfei Xu, Peter S. Hersh, MD, David S. Chu, MD Institutional Affiliations.
Oliver Findl 1,2, Nino Hirnschall 1,2, Alja Crnej 2 1 VIROS Vienna Institute for Research in Ocular Surgery, Hanusch Hospital, Vienna, Austria 2 Moorfields.
Paul “Butch” Harton, MD Harbin Clinic Eye Center Rome, GA USA ASCRS Boston Poster, 2010 The Author has no financial interest in the subject matter of this.
Evaluation of Long-Term Keratoconus Progression Using Scanning-Slit Topography First Author: David Galarreta, MD Contributing Authors: Nestor Cortes, MD,
Effect of Corneal Thickness on Selective Laser Trabeculoplasty to Decrease Intraocular Pressure as Primary or Secondary Treatment of Glaucoma ASCRS 2010.
Khairidzan Mohd Kamal MD
Variations in corneal biomechanical parameters and central corneal thickness during the menstrual cycle. Yakov Goldich, MD, David Zadok MD, Yaniv Barkana,
ELEVATION AND PACHYMETRY VALUES IN NORMAL CORNEAS OBTAINED BY GALILEI ASCRS Boston April Vision Sana Research Group Vision Sana Research Group.
Pattern of Pain and Analgesic use after Collagen Crosslinking for Progressive Keratoconus Ramon Coral Ghanem, MD, PhD. Renan Ferreira Oliveira, MD. Vinicius.
Comparison of Central Corneal Thickness and Peripheral Corneal Thickness using Sheimpflug system, Optical Coherence Tomography and Ultrasound Pachymetry.
The Effect of Corneal Anterior Surface Eccentricity on Astigmatism after Cataract Surgery Choul Yong Park MD 1 Sung Jun Lee MD 1 Prabjot Channa MD 2 Roy.
Naomi R. Goldberg, MD PhD Kenneth J. Wolf, MD Eric J. Wolf, MD FACS The authors have no financial interest in the subject matter of this poster. Comparison.
Adriana S. Forseto1, MD Walton Nosé1,2, MD
1 P.O. dei Pellegrini; A.S.L. Napoli 1Centro 2 Dipartimento di Oftalmologia, Seconda Università degli Studi Napoli Scheimpflug topography, Scanning-Slit.
Evaluation of Corneal Tomography in Primary Pterygium Sahil Goel, MD (Presenting Author), Murugesan Vanathi MD *The authors have no financial interests.
IOL Calculations Based on Partial Biometry in Humanitarian Missions Joseph Schmitz, MD Kimberly Davis, MD, FACS Scott McClatchey, MD The authors have no.
M. Escaf, J. Mendoza, L. Izquierdo jr., M. Henriquez Instituto de Ojos Oftalmo Salud Lima, Peru There is no financial interest in this poster.
Study of Flap Thickness Precision with a Femtosecond Laser Shinagawa LASIK Center Tatsuya Yonekawa,MSc ; Minoru Tomita,MD.PhD ; Youhei Iida,CE ; Yuko Inada,CE.
Financial Disclosure: Medical Director–Galilei R&D Consultant, Ziemer Group AG, Port, Switzerland Consultant & Territory Manager for.
Comparison of Central Corneal Thickness, Anterior Chamber Depth, and Central Corneal Power Measurements between Two Scheimpflug Imaging Systems Yuichi.
Authors: Leonidas Traipe Magdalena Rios Edison Villagra Allister Gibbons Marcelo Hidalgo Claudia Goya Authors have no financial interest.
Comparision of ultrasound A- scan with optical A-scan Dr.Somshekar.N Consultant Refractive Services Narayana Nethralaya, Bangalore No Finanacial Interest.
Comparison of Endothelial Keratoplasty (EK) Visual Outcomes with OCT Derived Corneal Thickness Measurements Authors Abraham K. Sleem, MD Robert L. Schultze,
Augenabteilung am St. Franziskus Hospital Münster Lasik Flap Thickness using the Zyoptix XP Microkeratome Susanne Stottmeister, Suphi Taneri * * Travel.
COMPARISON AND EVALUATION OF OCULAR BIOMETRY USING A NEW NON-CONTACT OPTICAL LOW COHERENCE REFLECTOMETER David Goldblum 1,3, Kaspar Rohrer 1, Rudolf Waelti.
Fungal Infection Post Corneal Cross Linking, Case Record Ahmed Sedky, FRCOphth, Cairo, Egypt The author of this poster have received consultant reimbursement.
Corneal Endothelial Cell Loss Results in a Comparison of Longitudinal vs. Torsional with Vacuum Demand Interjected Longitudinal (IP) Phacoemulsification.
Evaluating Post Laser Refractive Surgery Corneal Thickness Using Artemis-2 Very High Frequency Arc-Scanning Ultrasonography Versus Pentacam * † Sharon.
Poster# P36 Comparison of Techniques of Measuring Anterior Chamber Depth and Corneal Curvature in Indian Eyes Sujata Das, MS, FRCS Anjula Kumari, B.Optom.
Changes of Axial Length After LASIK Surgery: A 3-Year Follow-Up Study
Characteristics of Primary Angle-Closure Glaucoma Patients with Normal Intraocular Pressure at the First Visit Won Hyuk Oh1, Bum Gi Kim1, Joo Hwa Lee2.
Corneal Pachymetry in Prediction of Refraction After Cataract Surgery
Date of download: 10/26/2017 Copyright © ASME. All rights reserved.
Maria A Henriquez MD Luis Izquierdo MD Jackeline Parraga MD
Comparison of Single-Scheimpflug and Dual-Scheimpflug Pachymetry Measurements and Effect of Decentration World Cornea Congress VI April 7-9, 2010.
and High-Order Aberrations After Intrastromal Presbyopia Correction
Comparison of Central Corneal Thickness measured by
Comparison of corneal powers obtained from four different devices
Associate Professor of Ophthalmology
Vicente J. Correa-Gomez MD, Guillermo Tapia MD, Oscar Macias Manuel MD, Alejandro Navas Perez MD, Gilberto Islas MD, Tito Ramírez-Luquin MD, Enrique O.
The association between changes in synovial fluid levels of ARGS-aggrecan fragments, progression of radiographic osteoarthritis and self-reported outcomes:
Sun Woong Kim, M.D.1, Hae Jung Sun, M.D.1,
Yakov Goldich MD,Yaniv Barkana MD, Isaac Avni MD, David Zadok MD,
Bernilla E; Izquierdo Jr. L; Miranda M.
Corneal Biomechanics after Penetrating Keratoplasty and Descemet’s Stripping Automated Endothelial Keratoplasty Samer Hamada MRCOphth FRCS(Ed)1,3 Louai.
Khairidzan Mohd Kamal MD
I.J.E van der Meulen1, C.P. Nieuwendaal1,
Pupil centre shift between bright light and dim light conditions
John C. Hwang, MD MBA Edward S. Harkness Eye Institute
The Effect of Corneal Thickness on Ocular Drug Penetration
Refractive Surgery Outcomes: Corneas Thinner than 500 microns Vs
Bland-Altman plot of arterial and central venous blood Pco2 showing the regression line (solid line) and the 95% limits of agreement of −12.3 to 4.8 mmHg.
International Vision Correction Research Centre
Presentation transcript:

Klinik und Poliklinik für Augenheilkunde All authors have no financial interest in the subject matter of this poster. R. Khoramnia, J. P. Salgado, C.P. Lohmann, C. Winkler von Mohrenfels ASCRS 2011 Comparison Between Central Corneal Thickness Measurements in Healthy Eyes Using a New Device and 2 Other Methods

Purpose Klinik und Poliklinik für Augenheilkunde The TMS-5 (Tomey) is a new device for the examination of the anterior eye segment combining Placido- and Scheimpflug-Technology. The purpose of this study was to compare central corneal thickness (CCT) measurements using TMS-5, LenStar/Allegro Biograph (Haag-Streit/WaveLight), and the gold standard ultrasonic pachymetry (Pachymeter SP-3000, Tomey). TMS-5 Foto: Allegro Biograph/LenStar Foto: SP-3000 Foto:

Material and methods Klinik und Poliklinik für Augenheilkunde 48 eyes of 24 healthy volunteers were included in this comparative study. In all eyes, CCT was measured with the TMS-5 (Tomey, Nagoya, Japan), LenStar (Haag-Streit AG, Koeniz, Switzerland)/Allegro Biograph (WaveLight AG, Erlangen, Germany), and ultrasonic pachymetry (Pachymeter SP-3000, Tomey, Nagoya, Japan). The values obtained from the different devices were compared using Bland-Altman plots and linear regression.

Results I Klinik und Poliklinik für Augenheilkunde The mean CCT readings with the TMS-5, LenStar/Allegro Biograph, and ultrasound were µm, µm, and µm, respectively. Regression analysis showed a high correlation between the values obtained with the TMS-5 and the LenStar/Allegro Biograph (r=0.950, p<0.001) and the values obtained with the TMS-5 and ultrasound (r=0.918, p<0.001).

Results II Klinik und Poliklinik für Augenheilkunde Compared to the LenStar/Allegro Biograph and ultrasound, the TMS-5 underestimated the CCT. The mean differences were µm compared to the LenStar/Allegro Biograph and µm compared to ultrasound as shown in the Bland-Altman plots.

Conclusion Klinik und Poliklinik für Augenheilkunde Regression analysis showed a high correlation between the values obtained with the TMS-5 and the LenStar/Allegro Biograph and the values obtained with the TMS-5 and ultrasound. However, the TMS-5 underestimated the CCT compared to the LenStar/Allegro Biograph and ultrasound. Therefore, the TMS-5, LenStar/Allegro Biograph, and ultrasound should not be used interchangeably for the measurement of CCT.

Name der Klinik Klinik und Poliklinik für Augenheilkunde Contact: Klinikum rechts der IsarTel.: – 2310 Technische Universität MünchenFax: – 4076 Klinik und Poliklinik für Augenheilkunde Ismaninger Str. 22www.med.tum.de Munichwww.augenklinik.med.tum.de GERMANY