Hiden Analytical Excellence in plasma diagnostics An Introduction to the Hiden EQP Excellence in Plasma Diagnostics An Introduction to the Hiden EQP www.HidenAnalytical.com.

Slides:



Advertisements
Similar presentations
A. Samarian, W. Tsang, J. Khachan, B. James Complex Plasma Laboratory School of Physics, University of Sydney, NSW 2006, Australia.
Advertisements

What is the ISOLDE cooler RFQ CB - ISCOOL H. Frånberg.
Mass Spectrometry Chem 3500 Mass Spectrometry Y. Zhao Lecture 2 A Glimpse of Mass Spectrometry Began from 1920s: Aston, Dempster, Thompson MS is often.
High Pressure Plasma with a third electrode James Roberts Physics TSP 2002 Supervised by Dr Kerrie Balla.
FTIR ● Quite often EDS analysis will give only C and O peaks meaning that the material is organic. ● FTIR is sensitive to vibrations between bonds in materials.
Performance of a Hybrid RF/DC Quadrupole-Linear Ion Trap Mass Spectrometer James W. Hager MDS SCIEX ASMS, 2002.
FC-MS from Teledyne Isco CombiFlash ® a Name You Can Rely On.
Andreas Steinbach, Stefan Wurm, Christian Koelbl Ferdinand Bell, Daniel Koehler, Dirk Knobloch Sematech AEC/APC Symposium X Plasma etch control by.
Inductively Coupled Plasma Mass Spectrometry or ICP-MS
Ion Injector Design Andrew Seltzman.
NEGATIVE ION PLASMAS Professor Robert L. Merlino Department of Physics & Astronomy University of Iowa Plasma Physics Seminar, April 23, 2007.
427 PHC.  Atomic emission spectroscopy (AES) is based upon emission of electromagnetic radiation by atoms.
Mass Spectrometry Inlet system Ion Source Mass Analyzer Ion Detector.
Mass Spectroscopy Mass Spectrometry ä Most useful tool for molecular structure determination if you can get it into gas phase ä Molecular weight of.
POLYMERISATION PROCESSES IN LOW-PRESSURE FLUOROCARBON PLASMAS
Chapter 20 Molecular Mass Spectrometry. Introduction... Mass spectroscopy is perhaps one of the most widely applicable of all the analytical tools available.
Mass Analyzers Double Focusing Magnetic Sector Quadrupole Mass Filter Quadrupole Ion Trap Linear Time-of-Flight (TOF) Reflectron TOF Fourier Transform.
Atomic Emission - AES M* → M + hn Thermal excitation M → M*
Atomic Mass Spectrometry
Mass Spectrometry.
Molecular Mass Spectrometry
Surface and volume production of negative ions in a low-pressure plasma E. Stoffels, W.W. Stoffels, V.M. Kroutilina*, H.-E. Wagner* and J. Meichsner*,
6. Mass Spectrometry Adv. Inst. Techs. How does it work? a very small amount of sample is bombarded by a beam of high energy (usually electron beam) produces.
Russell Rouseff FOS 6355 Summer 2005 What is Mass Spectroscopy Analytical Chemistry Technique Used to identify and quantify unknown compounds Can also.
Gas Chromatography And Mass Spectrometry
Agilent 7500 ICP-MS Date: 28JUL2005.
Atomic Emission Spectroscopy
F.M.H. Cheung School of Physics, University of Sydney, NSW 2006, Australia.
Study of negative ion surface production in caesium-free H 2 plasma PhD student: Kostiantyn Achkasov Tutors: Gilles Cartry and Alain Simonin 3 rd FUSENET.
PC4250 Secondary Ion Mass Spectrometry (SIMS). What is SIMS? SIMS is a surface analysis technique used to characterize the surface and sub-surface region.
Secondary ion mass spectrometry (SIMS)
An Inductively Coupled Plasma Etcher
Mass spectrometry Ions are analyzed on the basis of their m/z Chlorine has 2 isotopes, 35 Cl and 37 Cl, in the approximate ratio of 3 :1. Electrons are.
Mass spectrometry and the PITZ Sven Lederer Technisches Seminar
Molecular mass spectrometry Chapter 20 The study of “molecular ions” M + e -  M e -
Corial 200ML COSMA Software with:  Edit menu for process recipe edition,  Adjust menu for process optimizing,  Maintenance menus for complete equipment.
Negative Ions in IEC Devices David R. Boris 2009 US-Japan IEC Workshop 12 th October, 2009 This work performed at The University of Wisconsin Fusion Technology.
FETS H - Ion Source Experiments and Installation Scott Lawrie, Dan Faircloth, Alan Letchford, Christoph Gabor, Phil Wise, Mark Whitehead, Trevor Wood,
Plasma diagnostics using spectroscopic techniques
The Apparatus…. Ionic target studies…. Neutral target studies…. Queens University Belfast University College London.
MS Intro. MS requires gas-phase ions, why? MS uses magnetic and electric fields to control the path of a compound based on mass to charge ratio (m/z)
7-1 Atomic Mass Spectroscopy General Features Mass Spectrometers §Sources Atomic mass spectroscopy determines elements by mass §Mass to charge ratio §Lower.
Mass spectrometry (Test) Mass spectrometry (MS) is an analytical technique that measures masses of particles and for determining the elemental composition.
M. Ichimura, Y. Yamaguchi, R. Ikezoe, Y. Imai, T. Murakami,
Molecular Deceleration Georgios Vasilakis. Outline  Why cold molecules are important  Cooling techniques  Molecular deceleration  Principle  Theory.
CCFE is the fusion research arm of the United Kingdom Atomic Energy Authority Beam Species Measurements on the MAST NBI system Brendan Crowley Thanks to.
Gregory ClarkeTechnological Plasmas Research Group Time resolved diagnostics for pulsed magnetron plasmas.
Techniques for Nuclear and Particle Physics Experiments By W.R. Leo Chapter Eight:
-Plasma can be produced when a laser ionizes gas molecules in a medium -Normally, ordinary gases are transparent to electromagnetic radiation. Why then.
Secondary Ion Mass Spectrometry A look at SIMS and Surface Analysis.
X-ray absorption spectroscopy (XAS)
Lecture 3-Building a Detector (cont’d) George K. Parks Space Sciences Laboratory UC Berkeley, Berkeley, CA.
Developments of the FETS Ion Source Scott Lawrie.
11/8/ Diagnostic and Etching Studies of Inductively Coupled Plasmas SFR Workshop November 8, 2000 Matthew Radtke, John Coburn, David Graves Berkeley,
Large Area Plasma Processing System (LAPPS) R. F. Fernsler, W. M. Manheimer, R. A. Meger, D. P. Murphy, D. Leonhardt, R. E. Pechacek, S. G. Walton and.
APS, 44th Annual Meeting of the Division of Plasma Physics November 11-15, 2002; Orlando, Florida Hard X-ray Diagnostics in the HSX A. E. Abdou, A. F.
Initial Results from the Scintillator Fast Lost Ion Probe D. Darrow NSTX Physics Meeting February 28, 2005.
Studies on 2.45 GHz microwave ion sources Abhishek Nag IISER, KOLKATA Presented By: G.O. Rodrigues IUAC, New Delhi Supervised By:
Hiden EPIC Quadrupole Mass Spectrometer for Scientific Applications.
Quadrupole Mass Spectrometry Concepts Mass Spectrometers for Residual Gas Analysis.
Hiden HPR-20 QIC EGA for evolved gas analysis in TGA-MS.
PS-ESS and LEBT State of the art Lorenzo Neri Istituto Nazionale di Fisica Nucleare Laboratori Nazionali del Sud.
Chapter 29 Mass Spectrometry. 29 A Principles of mass spectrometry In the mass spectrometer, analyte molecules are converted to ions by applying energy.
Hiden Compact SIMS Mass Spectrometry in solid material.
Components of Mass Spectrometer
Acknowledgements Slides and animations were made by Dr. Jon Karty Mass Spectrometry Facility Indiana University, Bloomington.
Seok-geun Lee, Young-hwa An, Y.S. Hwang
Mass Spectroscopy. Mass Spectroscopy Mass Spectrometry Most useful tool for molecular structure determination if you can get it into gas phase Molecular.
Testbed for Plasma-Wall and Etch Product Studies
M.Prasad Naidu MSc Medical Biochemistry, Ph.D,.
Presentation transcript:

Hiden Analytical Excellence in plasma diagnostics An Introduction to the Hiden EQP Excellence in Plasma Diagnostics An Introduction to the Hiden EQP Introduction

Hiden Analytical Excellence in plasma diagnostics An Introduction to the Hiden EQP Excellence in Plasma Diagnostics Plasma Processes  Techniques  DC Magnetron  Pulsed Plasma  Laser Ablation  RF Driven  TCP  ICP  Electron Cyclotron Resonance  Applications  PECVD  Etching  PVD  Plasma Spray  Hard Coatings  Ion implantation

Hiden Analytical Excellence in plasma diagnostics An Introduction to the Hiden EQP Excellence in Plasma Diagnostics Factors Affecting Plasma Constituents  Macroscopic  Power Feeds  Gas supply  Pressure  Electric Fields  Magnetic fields  Heating / cooling  Leaks  Contamination  Physical factors  Microscopic  Neutrals  Positive / Negative ions  Electrons  Radicals  Gas phase reactions Complex System To Predict Factor Affecting Plasma Constituents

Hiden Analytical Excellence in plasma diagnostics An Introduction to the Hiden EQP Excellence in Plasma Diagnostics What can the EQP do for you? The Hiden EQP is a combined Mass / Energy analyser for the analysis of IONS, NEUTRALS, and RADICALS from plasma processes The Hiden EQP system comprises:  Ion extraction optics  Ioniser  Sector field energy analyser  Triple filter mass analyser  Pulse ion counting detector  PC data system with Windows software

Hiden Analytical Excellence in plasma diagnostics An Introduction to the Hiden EQP Excellence in Plasma Diagnostics The Hiden EQP. Collector QUADRUPOLE ENERGY ANALYSER Pumping Orifice Extractor Lens 1 Filaments F1, F2, e - Energy Source cage Axis Lens 2 Quad, Vert, Horiz Axis Focus Suppressor 1 st Dynode

Hiden Analytical Excellence in plasma diagnostics An Introduction to the Hiden EQP Excellence in Plasma Diagnostics The Hiden EQP The Hiden EQP. Laser Drilled Orifice  User defined dimension from 30  m  +ve / -ve ions, neutrals or radicals  Pre-thinned for optimum sampling  Software control for minimum plasma effects  Plasma electrode coupling option – allows the user to configure the orifice to exactly follow electrode conditions during operation.

Hiden Analytical Excellence in plasma diagnostics An Introduction to the Hiden EQP Excellence in Plasma Diagnostics The Hiden EQP The Hiden EQP. Extractor / Lens Assembly  Software controlled extraction / Focus  Discriminates +ve, -ve, e -, radicals  Fully tuneable for optimal detection  Integrated ionisation source

Hiden Analytical Excellence in plasma diagnostics An Introduction to the Hiden EQP Excellence in Plasma Diagnostics The Hiden EQP 45° Electrostatic Sector Analyser  Optimum transmission cf. Bessel box  Minimum perturbation of ion flight path  Constant ion transmission at all energies  Energy resolution down to 0.25 eV FWHM  Energy scan at increments from 0.05 eV  Floating option up to 10 KeV

Hiden Analytical Excellence in plasma diagnostics An Introduction to the Hiden EQP Excellence in Plasma Diagnostics The Hiden EQP The Hiden EQP. Triple Filter Quadrupole  Discrete ioniser as standard  RF only pre / post filters  Minimises effects of fringe fields  Enhanced peak separation / transmission  Detection to 5 PPB  Enhanced long term stability  Enhanced contamination resistance  Full source control, e - attachment option

Hiden Analytical Excellence in plasma diagnostics An Introduction to the Hiden EQP Excellence in Plasma Diagnostics The Hiden EQP The Hiden EQP. Channeltron PIC  7 decades continuous dynamic range  24 bit counter for 1c /s resolution  Faraday Cup for high density plasmas  Signal gating with 1  s resolution – energy & mass distributions vs time  TTL / DDE data export options

Hiden Analytical Excellence in plasma diagnostics An Introduction to the Hiden EQP Excellence in Plasma Diagnostics EQP Options  2500 amu option for polymer and cluster studies  Gating input for pulsed plasma applications  Positive and negative ion capability  Etching or deposition studies

Hiden Analytical Excellence in plasma diagnostics An Introduction to the Hiden EQP Excellence in Plasma Diagnostics EQP Options amu EQP with z drive EQP with RF driven electrode EQP Options

Hiden Analytical Excellence in plasma diagnostics An Introduction to the Hiden EQP Excellence in Plasma Diagnostics The Hiden EQP may be configured for:  Analysis through a --- viewport --- grounded electrode --- driven electrode  High pressure plasmas with double differential pumping  Magnetically confined plasmas with Mu-metal & radio-metal shielding  Analysis of high mass (1000 amu)  Analysis of high energy (1000 eV)

Hiden Analytical Excellence in plasma diagnostics An Introduction to the Hiden EQP Excellence in Plasma Diagnostics Example Data EQP measuring every 20 ms 100 ppb C + at ~20ppb

Hiden Analytical Excellence in plasma diagnostics An Introduction to the Hiden EQP Excellence in Plasma Diagnostics Electron Energy Spectra The data compares the appearance potentials for the principle cluster ions formed from Buckminsterfullerene

Hiden Analytical Excellence in plasma diagnostics An Introduction to the Hiden EQP Excellence in Plasma Diagnostics Negative Ions/Ion Energy Distribution Negative Ions / Ion Energy Distributions The data show the presence of O - formed from e - + CO 2  O - + … Discrete paths at e - energies of 70, 8.5 and 4.2 eV. The ion energy distribution of these species is seen to be a function of the electron energy involved.

Hiden Analytical Excellence in plasma diagnostics An Introduction to the Hiden EQP Excellence in Plasma Diagnostics Energy Analysis of Plasma Components SF + Energy V SF 2 + Energy V SF 3 + Energy V F + ions  Even in an apparently homogeneous plasma the individual component species can exhibit a wide variation in energies.

Hiden Analytical Excellence in plasma diagnostics An Introduction to the Hiden EQP Excellence in Plasma Diagnostics Examination of Plasma-Specific Processes H - /CH 4 Plasma Off e - + H 2 = H - H - /CH 4 Plasma On  The plasma produces activated species as well as electrons.  These species can interact and react in highly specific fashion e.g. hydride anion formation.

Hiden Analytical Excellence in plasma diagnostics An Introduction to the Hiden EQP Excellence in Plasma Diagnostics Electron Attachment Analysis  O - species may be formed from various precursors e.g. CO, CO 2, N 2 O via electron attachment and subsequent dissociation. However the low energy resonant electrons required for this process are characteristic of the precursor involved.

Hiden Analytical Excellence in plasma diagnostics An Introduction to the Hiden EQP Excellence in Plasma Diagnostics Also available: Langmuir Plasma Probes.  RF compensated Langmuir Probe with Z-drive  Automatic analysis with real time trend display of key plasma parameters including:  Ion Density  Plasma Potential  Electron Energy  Debye Length Also available