Meteorologisches Observatorium Lindenberg A COMPARISON OF SCAPP RADIATION DATA WITH GLOBAL, DIFFUSE AND DIRECT RADIATION AS WELL SUNSHINE DURATION Klaus.

Slides:



Advertisements
Similar presentations
Maintenance system and technology used in FMI´s observation network Jani Gustafsson Introduction FMI´s observation network.
Advertisements

3) Empirical estimate of surface longwave radiation Use an empirical estimate of the clear-sky surface downward longwave radiation (SDLc) to estimate the.
Meteorological Observatory Lindenberg – Richard Assmann Observatory The GCOS Reference Upper Air Network.
WP 5 : Clouds & Aerosols L.G. Tilstra and P. Stammes Royal Netherlands Meteorological Institute (KNMI) SCIAvisie Meeting, KNMI, De Bilt, Absorbing.
WELCOME TO WORLD RADIATION DATA CENTER (WRDC) 2008: - 44 Years of Activity. WMO GAWROSHYDROMETMGO.
Measurement of Radiation - Solar radiation - Long wave radiation - Net radiation - Exposure of radiation sensors.
1. A positive correlation. As one quantity increases so does the other. 2. A negative correlation. As one quantity increases the other decreases. 3. No.
Version 1003 State of the art of indoor calibration of pyranometers and pyrheliometers.
Using ARCON96 for Control Room Radiological Habitability Assessments
1 / 17 Deutscher Wetterdienst Meteorological Observatory Lindenberg Richard Assmann Observatory The GCOS Reference Upper Air Network Holger Vömel GRUAN.
Met 163: Lecture 2 Human aspects of measurement human perception vs sensor measurements reasons for automation design, implementation, and maintenance.
MET 61 1 MET 61 Introduction to Meteorology MET 61 Introduction to Meteorology - Lecture 8 “Radiative Transfer” Dr. Eugene Cordero San Jose State University.
(3) Measuring Radiation Physics of the Atmosphere II Atmo II 57.
Solar Radiation Measurement, Modeling, and Performance Prediction Prepared for Solar Minnesota by Darryl Thayer.
Determination of Longwave Response of Shortwave Solar Radiometers to Correct for their Thermal Offset Errors 1 National Renewable Energy Laboratory Golden.
Meteorological Observatory Lindenberg – Richard Assmann Observatory The GCOS Reference Upper Air Network.
Dynamic thermal rating of power transmission lines related to renewable resources Jiri Hosek Institute of Atmospheric Physics, Prague, Czech Rep.
Regional Radiation CENTER Tokyo in the WMO RA-II
SGP BORCAL Overview September 2005 Craig Webb, Ibrahim Reda, & Tom Stoffel U.S. DOE Atmospheric Radiation Measurement (ARM) Program.
Sensor accuracy in environmental sensor networks Alex Dionisio Calado Joan Suris Miret EPFL,
Evaluation and applications of a new satellite-based surface solar radiation data set for climate analysis Jörg Trentmann1, Richard Müller1, Christine.
Long-term analyses of surface shortwave irradiance, clouds and aerosols over China T. Hayasaka 1, K. Kawamoto 1, and G.Y. Shi 2 1.Research Institute for.
An Integrated Meteorological Surface Observation System By Wan Mohd. Nazri Wan Daud Malaysian Meteorological Department Due to the increasing and evolving.
Piezoelectric precipitation sensor from VAISALA
TECO2005WRC/PMOD Quality Management1 The World Radiometric Reference and its Quality System ISO/IEC Wolfgang Finsterle, Isabelle Rüedi, and Silvio.
Fig. 3 shows how a dose distribution that is initially relatively sharp becomes blurred with time, until after 16 hours, virtually no useful information.
Aerosol Optical Depth measurements in the Azores Fernanda Carvalho 1 Diamantino Henriques 1 Paulo Fialho 2 Vera Bettencourt 1 1 Instituto de Meteorologia.
A COMPARISON OF DIFFERENT SOLAR RADIANCE SENSORS FOR PV APPLICATIONS Mavromatakis F., Franghiadakis Y., Chalampalakis G. and Vignola F. TEI of Crete &University.
Royal Meteorological Institute of Belgium Validation of the method to retrieve the AOD and first preliminary results of the aerosol measurements campaign.
中新天津生态城 China temperature variation in the last 60 years Jiang Yangming.
Calibration of a Yankee Environmental Systems UltraViolet Rotating Shadow Band Radiometer at Mauna Loa Hawaii Presented at the 10 th International Pyrheliometer.
1 NOAA-UPRM COOP Program in Atmospheric Sciences and Meteorology, Department of Physics, University of Puerto Rico at Mayagüez, Mayagüez, PR Yaítza.
Meteorological Observatory Lindenberg Results of the Measurement Strategy of the GCOS Reference Upper Air Network (GRUAN) Holger Vömel, GRUAN.
Meteorological Observatory Lindenberg – Richard Assmann Observatory (2010) GCOS Reference Upper Air Network Holger Vömel Meteorological Observatory Lindenberg.
A monitor of the vertical turbulence distribution MASS: Victor Kornilov a, Andrei Tokovinin b, Olga Vozyakova a, Andrei Zaitsev a, Nicolai Shatsky a, Serguei.
A new method for first-principles calibration
Estimation of Potential Evapotranspiration from Merged CERES and MODIS Observations Anand Inamdar & A. French Arid Land Agricultural Research Center (ALARC/ARS/USDA)
Proposed Instrument for Deployment at Climate Reference Network (CRN) Sites: Multi-Filter Rotating Shadowband Radiometer (MFRSR) The MFRSR measures solar.
Scatter Graphs Scatter graphs are used to show whether there is a relationship between two sets of data. The relationship between the data can be described.
AERONET DRAGON Campaign, Summer 2011 Christina Justice College Park Scholars – Science & Global Change Program Environmental Science and Policy
JMA’s routine aerosol observations and Activities in the RRC Ⅱ kohei HONDA Regional Radiation Center (RRC) II (Asia) Global Environment and Marine Department.
Solar Radiation Characteristics
European Geosciences Union General Assembly 2016 Comparison Of High Resolution Terrestrial Laser Scanning And Terrestrial Photogrammetry For Modeling Applications.
Case application: Insulation and glazing, The Netherlands Harry Vreuls, NL Agency Workshop: Harmonization in Energy Savings Calculation: How To Fit International.
Review Meeting – December 16, 2014 Task 2.2 Weather Forecasting Data Capturing Module.
Tayba Buddha Tamang Meteorology/Hydromet Services Division Department of Energy Ministry of Economic Affairs South Asian Climate Outlook Forum (SASCOF-1)‏
ITALIAN AIR FORCE METEOROLOGICAL SERVICE AND MÉTÉO FRANCE UPDATING AND DEVELOPMENT OF METHODS FOR WORLDWIDE ACCURATE MEASUREMENTS OF SUNSHINE DURATION.
IEAP – CTU Prague Measurement of neutron flux during irradiation in NPI Řež T. Slavíček, V. Linhart, S. Pospíšil Institute of Experimental and Applied.
Solar Intelligence Lessons learnt in Australia Bruce W Forgan Observation & Infrastructure Branch Observations and Infrastructure Division Australian Bureau.
Thomas C. Stone U.S. Geological Survey, Flagstaff, AZ USA GSICS Research Working Group Meeting EUMETSAT 24−28 March 2014 Using the Moon as a Radiometric.
SIGNAL CONDITIONING Signal conditioning is stage of instrumentation system used for modifying the transduced signal into a usable format for the final.
IPC-XII Symposium, Sep28-Oct16, 2015
Calibration of a Yankee Environmental Systems
Automatic Weather Station (BAS)
Mini SCADA System for Monitoring PV and Wind-Installation in Meteorology stations Prepared By: Ahmad Khalil Mohammad Sayeh Supervisor: Dr. Imad Ibir
Radiation Center Budapest
Results of Baltic Region Pyrheliometer Comparison, BRPC-2012
DETERMINATION OF PHOTOSYNTHETICALLY ACTIVE RADIATION
Emma Hopkin University of Reading
Current HMI Polar Fields
Main geophysical observatory (MGO) activities.
Handbook on Meteorological Observations
National Satellite Meteorological Centre
Technical Conference on Meteorological and Environmental Instruments and Methods of Observation TECO 2006 Geneva, 4th – 6th December Validation.
Calculation SW fluxes by SAIL and MGO parametrization
Chapter 4B: SOLAR IRRADIATION CALCULATION
788.11J Presentation “Atmospheric Observatory”
Electrophoresis: Movement of a solid phase with respect to a liquid (buffer) Sample is applied to the medium and under the effect of electric field, group.
Scatter Graphs Scatter graphs are used to show whether there is a relationship between two sets of data. The relationship between the data can be described.
Continued positive trend in surface solar radiation over Sweden
Presentation transcript:

Meteorologisches Observatorium Lindenberg A COMPARISON OF SCAPP RADIATION DATA WITH GLOBAL, DIFFUSE AND DIRECT RADIATION AS WELL SUNSHINE DURATION Klaus Behrens and Rolf-Dieter Grewe German Weather Service Meteorological Observatory Lindenberg TECO, Bucharest, Scapp 01

Meteorologisches Observatorium Lindenberg TECO, Bucharest, Scapp 02 Outline Introduction The Scanning Pyrheliometer/Pyranometer Technical Description Calibration Comparisons of SCAPP with pyrheliometer and pyranometer data hourly means daily totals Conclusions

Meteorologisches Observatorium Lindenberg TECO, Bucharest, Scapp 03 about 30 manned stations Radiation Network of the German Weather Service Global radiation  Global and diffuse solar radiation  Atmospheric downward radiation two ventilated and heated CM11 measuring global and diffuse solar radiation sunshine duration is measured by a SONIe rising requests from several users for a higher spatial resolution to extend the radiation network at a stable number of manned is only possible with an instrument allowing an automatic (unmanned) operation

Meteorologisches Observatorium Lindenberg TECO, Bucharest, Scapp 04 Bergholter and Dehne (1992) showed the possibility to measure global, diffuse and direct solar radiation with one instrument the so called SCAnning Pyrheliometer/Pyranaometer (SCAPP) in future the radiation network of the German Weather Service will consist of about 30 manned stations using pyranometers (basic network) and an extending one of about 130 automatic (unmanned) stations applying the SCAPP

Meteorologisches Observatorium Lindenberg TECO, Bucharest, Scapp 05 The SCAPP as it is used for measuring direct, diffuse and global solar radiation as well as sunshine duration. Head and sensor module of the SCAPP consist of a spherical sector diaphragm (1), a diffuser (2), a beam- guide (3), two filter slides KG4 (4a), BG34 (4b) glass and a photodetector (5). weight: 5 kg height: 260 mm diameter: 185 mm data transmission via RS232 or RS422/485

Meteorologisches Observatorium Lindenberg TECO, Bucharest, Scapp 06 Schematic courses of the SCAPP signal during one rotation of the head describing different conditions (a) and (b). SCAPP needs more than one factor for the correct calculation of the different radiation quantities a basic sensitivity of diffuse radiation diffuse radiation inside the SCAPP depends on direct radiation a correction factor for the diffuse radiation is necessary a sensitivity of the direct radiation has to be determined SCAPP calibration has to be made outside using the Sun as source direct and diffuse solar radiation have to be measured in parallel with the registration of the voltage of the SCAPP

Meteorologisches Observatorium Lindenberg TECO, Bucharest, Scapp 07 Radiation platform at the Meteorological Observatory Lindenberg with the reference instruments from the BSRN station for the comparison with the SCAPP. The SCAPP at the radiation platform during the comparison. Reference instruments: CH CM CM voltages were recorded by a COMBILOG data logger and then converted into irradiances SCAPP data were converted by its own microprocessor all data stored as 1 minute means

Meteorologisches Observatorium Lindenberg TECO, Bucharest, Scapp 08 Fig. a-c: Scatter diagrams of hourly means of global (G), diffuse (D) and direct solar radiation (I) measured by the SCAPP (sca) and pyranometers as well as a pyrheliometer as reference instruments (ref) and the corresponding regression lines in March, respectively. Furthermore, in the text boxes the regression coefficients and the coefficient of determination (R²) are given.

Meteorologisches Observatorium Lindenberg TECO, Bucharest, Scapp 09 Fig. a-c: Scatter diagrams of hourly means of global (G), diffuse (D) and direct solar radiation (I) measured by the SCAPP (sca) and pyranometers as well as a pyrheliometer as reference instruments (ref) and the corresponding regression lines in July, respectively. Furthermore, in the text boxes the regression coefficients and the coefficient of determination (R²) are given.

Meteorologisches Observatorium Lindenberg TECO, Bucharest, Scapp 10 Fig. a-c: Scatter diagrams of hourly means of global (G), diffuse (D) and direct solar radiation (I) measured by the SCAPP (sca) and pyranometers as well as a pyrheliometer as reference instruments (ref) and the corresponding regression lines in December, respectively. Furthermore, in the text boxes the regression coefficients and the coefficient of determination (R²) are given.

Meteorologisches Observatorium Lindenberg TECO, Bucharest, Scapp 11

Meteorologisches Observatorium Lindenberg TECO, Bucharest, Scapp 12 Hourly ratios Gsca/Gref in dependence on Gref for July and December.

Meteorologisches Observatorium Lindenberg TECO, Bucharest, Scapp 13 Annual courses for the daily ratios Gsca/Gref and Dsca/Dref.

Meteorologisches Observatorium Lindenberg TECO, Bucharest, Scapp 14 Conclusions: The comparison showed that the measurements of the SCAPP in most cases are in good agreement with the results of the reference instruments. At lower global radiation (about <75 W/m²) the SCAPP results are frequently to low in comparison with the reference. In future this will be improved. The SCAPP is a multisensor of „Moderate quality“, which is suitable for radiation measurements where highest quality is not demanded. Thank you for your attention!