Deemed Savings Update: ECMs in Display Cases Ben Cartwright PECI January 5, 2009.

Slides:



Advertisements
Similar presentations
Grocery Store Measures Door Gasket, Automatic Door Closers, and Strip Curtain Laboratory Testing.
Advertisements

Add Doors to Open Multi-deck Cases: Provisional UES RTF Meeting August 30,
UPDATE ON GROCERSMART 4.0 RESEARCH PLAN Regional Technical Forum May 3, 2011.
GrocerSmart 4.0 redesign -request for rtf input- February 25, 2010.
Planning for Updates and Linkages to EM&V CALMAC February 17, 2004.
Grocery Store Measures
Evaluation of Energy Savings for Strip Curtains Presented To RTF Scott Moore PECI Sr. Engineer June 2, 2009.
RTF 2012 Workplan Statements of Work January,
EDISON INTERNATIONAL® SM Internal Use Only Page 1 Commercial Variable Speed Swimming Pool Pump Jason Wang Cal TF Work Paper Presentation October 23, 2014.
Grocery Measure: LEDs for Reach-In Display Cases Regional Technical Forum July 21 st, 2015 Mohit Singh-Chhabra.
LED Case Lighting With and Without Motion Sensors Michele Friedrich – Sr. Engineer PECI 1/5/2010.
Floating Head Pressure for Refrigeration Single Compressor Systems Michele Friedrich, PE – Sr. Engineer Dustin Bailey – Engineer PECI 11/2/2010.
Regional Technical Forum July 1st, 2008 Presented by Ryan Fedie and Jamie Anthony Portland Energy Conservation, Inc.
Today’s “Game Plan” Two Trial-Runs of a new deemed measure review process – Deemed measure analysis and review Developed by … – (consultant, RTF member/staff,
Night Covers on Open Vertical Cases Provisional UES Proposal Presentation to the Regional Technical Forum August 30,
© 2001 The Gas Company. All copyright and trademark rights reserved. High Efficiency Unit Heaters Workpaper Presentation Prepared for Cal TF Presentation.
Retrofit Doors to Open Vertical Cases Provisional UES Proposal Presentation to the Regional Technical Forum August 30,
Commercial Refrigerators and Freezers
Plans to bring Out-of-Compliance UES Measures back into Compliance: 1. Agricultural Irrigation Hardware UES 2. Agricultural Motors UES Regional Technical.
1 EE Evaluation Report on 2009 Bridge Funding Period California Public Utilities Commission November 22, 2010 Energy Division Energy Efficiency Evaluation.
EDISON INTERNATIONAL® SM Internal Use Only Page 1 Circulating Block Heater Alfredo Gutierrez Cal TF Work Paper Presentation October 23, 2014.
B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Residential LED Recessed Down light Fixtures RTF January 4, 2011.
Out-Of-Compliance Grocery UES Measure Recommendations Regional Technical Forum March 18, 2014.
LED Case Lighting in Vertical and Semi-Vertical Open Refrigerated Cases Eric Mullendore – Energy Analyst PECI 6/29/2010.
EnergySmart Grocer Program Evaluation Findings Summary PWP, Inc.
GrocerSmart™ 4.0 RTF Subcommittee Approval of Adherence to Guidelines March 10, 2011.
Grocery Measure: EC Motors for Display Cases Regional Technical Forum July 21 st, 2015 Mohit Singh-Chhabra.
Regional Technical Forum October 9, ECMs for Compressor Head Cooling Fans  Measure –Retrofit of compressor head cooling fans on low temperature.
Grocery Measure: EC Motors for Display Cases Regional Technical Forum June 16 th, 2015 Mohit Singh-Chhabra.
Standard Information Workbook (SIW) Update Proposal Regional Technical Forum May 13, 2014.
Strip Curtains for Refrigerated Walk-in Boxes Michele Friedrich, PE – Sr. Engineer Eric Mullendore – Energy Analyst PECI 8/3/2010.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Residential Appliance Measure Updates Danielle Gidding Bonneville Power Administration.
July 26, 2014 Refrigeration Subcommittee Proposed Revision of Refrigeration Provisional Data Requirements.
Anti-Sweat Heater Control Small Saver UES Measure Regional Technical Forum September 17, 2013.
Update: Grocery Refrigeration Provisional Standard Protocol for Site Specific Savings RTF Meeting June 28,
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump RTF Sub-Committee February 22, 2012 Mira Vowles, P.E., CEM.
EER Analysis Results Regional Technical Forum March 18, 2014.
New Refrigeration Measures - FHP Status Report- & -Request for Input- September 21, 2010.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Energy Savings from Electric Water Heaters in Commercial Applications Danielle Gidding.
DRAFT Preliminary: BPA Summary of 6 th Plan Supply Curves May 15, 2009 Lauren Gage
EnergySmart Grocer. 2 BPA background  The Bonneville Power Administration contracted Cascade Energy Engineering, Inc. to evaluate the GrocerSmart audit.
Out-Of-Compliance UES Measure Recommendations Part 1 – November Measures Regional Technical Forum November 19, 2013.
GrocerSmart™ 4.0 RTF Approval of Software and Adherence to RTF Guidelines April 5, 2011.
Ultra-Premium Efficiency Motor Standard Protocol Recommendation Regional Technical Forum November 19, 2013.
Measurement and Verification of Refrigeration Measures in 4 Grocery Stores in Pacific County Presented to the Regional Technical Forum August 8 th, 2006.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump Sub-Committee Alternative Incentive Approaches BPA Energy.
Variable Speed Heat Pumps Provisional UES Proposal Presentation to the Regional Technical Forum September 18, 2012 Presentation by Kacie Bedney, Bonneville.
High Efficiency Evaporator Coils for Medium Temperature Cases Dustin Bailey, Engineer PECI Jan 5, 2010.
Commercial Refrigerators and Freezers Efficiency Standards, Savings, and Cost RTF Meeting July 1, 2008.
T12 to HPT8 Change-outs Small/Rural request for development May 15, 2012.
Grocery Store Issues RTF April 10, Need Recommendations PECI: Energy Smart Grocer Program Savings method for interactive measures Savings method.
Out-Of-Compliance Grocery UES Measure Recommendations Regional Technical Forum July 15, 2014.
Grocery VSD Measure Deemed Savings Reid Hart, PE & Ken Anderson September 28, 2010.
GrocerSmart TM Energy Modeling Software -Revision Status Report- & -Request For Input- July 13, 2010.
PNW RoofTop Unit Working Group - RTUG – RTU Savings Research Project Phase 3 December 15, 2009.
Display Case Motion Sensors Small Saver Measure Update July 16th, 2013.
Northwest Power and Conservation Council Pre-Rinse Spray Valves RTF January 2007.
Regional Technical Forum Recommissioning commercial retail facilities: A whole building approach to energy savings April 7th, 2009 Presented by: Jeremy.
ENERGY STAR Commercial Refrigerators and Freezers Regional Technical Forum January 21 st, 2016 Mohit Singh-Chhabra.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump Sub-Committee Road-Mapping Session BPA Energy Efficiency.
December 11, 2012 Grocery UES Updates Reach-in LED and Case ECM.
Northwest Power and Conservation Council Energy Smart Grocer Update & Revisions RTF May 2007.
Commercial Refrigerators and Freezers Cost & Cost-Effectiveness RTF Meeting March 2nd, 2010 (continued from Feb 2 nd, 2010 meeting, with more Cost discussion.
GrocerSmart™ 4.0 RTF Approval of Software and Adherence to RTF Guidelines April 5, 2011.
PHASE 1 UES REVIEW: PROGRESS UPDATE December 13, 2011 Regional Technical Forum Presented by: Jeff Romberger and Mark Kendall.
New Refrigeration Measures -Status Report- & -Request for Input- September 13, 2010.
ANTONIO CORRADINI & M M VALMIKI, AESC MAY 26, 2016 High Efficiency PMSM Fan Assemblies for Refrigerated Case Evaporators - Abstract.
1 W-E Calculator 2.0 Workshop Experience Implementing the W-E Calculator Jill Kjellsson Program Manager – Industrial, Ag and Water April 6,
Regional Technical Forum May 27, 2008 Presented by Ryan Fedie and Jamie Anthony Portland Energy Conservation, Inc.
ANTONIO CORRADINI & M M VALMIKI, AESC JUNE 30, 2016 PMSM Fan Assemblies for Refrigerated Case Evaporators – Abstract Update.
Presentation transcript:

Deemed Savings Update: ECMs in Display Cases Ben Cartwright PECI January 5, 2009

Acknowledgements We would like to thank the following utilities for support BPA PSE AVISTA

Purpose Deemed measure approval Updated savings for ECMs in refrigerated display cases Measure Name Shaded Pole to ECM in Refrigerated Display Cases

Agenda Background Description of Measure History Energy Savings Summary of Analysis Analysis Methodology Findings Calculation Methodology PECI Experience / Market Results Current Savings Revised/Proposed Savings Cost Measure Life Technical and Program Specifications Conclusion

Background Description of Measure: Replace standard efficiency shaded pole motor with ECM in refrigerated display cases ◦Savings from reduction in input wattage (direct/auxiliary savings) ◦Savings from reduction in heat load with ECM replacement (refrigeration savings)

Background History: RTF updated savings SP- ECM in Walk-Ins (3/09) ◦Weighted motor wattages based on size from market data ◦Weighted case temperatures based on audit data ◦Deemed kWh savings increase of 50% Proposing savings for Display Case SP to ECMs using same approved methodology Summit Blue Energy Smart Grocer program evaluation: 469 kWh

Energy Savings Summary of analysis: Reviewed base case and efficient case wattages Analyzed existing historical data vs. “real world” data Revised savings

Energy Savings Description of Energy Savings Methodology Issue: Current savings use 100% 9 watt output – research indicates larger motors in the mix Review and research motor data Manufacturer’s data: Tyler, Hussmann, GE GrocerSmart © database store audits Invoices from installed measure and audit data Established ranges: HP mix (establishes wattage for direct/aux. savings) Case temperature mix (establishes refrigeration savings )

Energy Savings Findings – Motor HP Mix: Motor HP market based on actual invoices ◦3,652 installed motors from 46 different sites, as invoiced » 3,328 motors: 9 watt (91%) » 122 motors: watt (3%) » 202 motors: 37 watt (6%)

Energy Savings Findings – Case Temperature Mix Case mix temperature data ◦Grocery store audit data: 223 Stores; 23,986 motors » 67% medium temp (16,071 motors) » 33% low temp (7,915 motors)

Energy Savings Calculation Methodology Direct/Auxiliary Savings ◦(Baseline Input Watts) – (Efficient Case Input Watts) ◦Motors run 8760 hours for medium temp ◦Motors run 8395 hours for low temp (1 hour/day defrost)

Energy Savings Calculation Methodology Refrigeration Savings ◦Full Load Hours (FLH) higher for low temp cases ◦“System” Energy Efficiency Ratio (EER) lower for low temp cases ◦Degradation Factor (DF) is.98 = condenser degradation penalty

Energy Savings Calculation Methodology Conclusion Direct/Auxiliary savings increase due to the added mix of larger motors Existing case temperature mix confirmed from additional analysis

Results Current SP to ECM Measure Energy Savings Existing measure savings based on: ◦9 watt motor only ◦Medium and low temp cases mix (69%/31%) ◦337 kWh/motor Measure Baseline Fan Watts (Shaded Pole) Efficient Fan WattskWh Energy Savings 9 Watt OutputInput Watts kWh/motor Med/Low Temp Shaded Pole to ECM in display cases

Results Revised/Proposed Energy Savings: Increased pre (base case) and post (efficient case) wattage based on market audit data using ◦Weighted blend of wattages (direct/auxiliary) savings » 9 watt (91%), watt (3%), 37 watt (6%) ◦Display case temperature weighted blend (refrigeration) savings » 33% low temp » 67% medium temp

Results Revised/Proposed Energy Savings: New kWh based on weighted blend of motor wattages and case temperatures: ◦ 453 kWh/motor

Cost Assumptions/Data Current Full Measure Cost: $110/motor Equipment cost confirmed from submitted PNW invoices ◦9 watt: $48/motor average ◦16-23 watt: $46/motor average ◦37 watt: $50/motor average Labor cost confirmed from PNW invoices and industry research ◦PNW: $50/motor ◦PG&E SP to ECM 2008 deemed measure workpaper » $41/motor ◦Southern California Edison SP to ECM 2007 workpaper » $36.45/motor

Measure Life Assumptions/Data Measure Life/Effective Useful Life is 15 years ◦Southern California Edison 1, PG&E 2 and BPA 3 program all use 15 year measure life for ECMs » 1 Energy Savings Potential for Commercial Refrigeration Equipment. June U. S. Department of Energy. Arthur D. Little. p 5-51 » 2 CALMAC Protocols, Appendix F, Effective Useful Live Values for Major Energy Efficiency Measures, September 2000 » 3 Council Plan 1996; 15 year EUL used for all Retrofit HVAC Systems & Controls including motor retrofits

Technical/Program Specifications Terms and Conditions: ECMs replace shaded pole fan motors in refrigerated display case ◦“Applicable to existing standard efficiency shaded pole evaporator fan motor for refrigerated display cases. Shaded pole motors must be replaced by electronically commutated motors (ECMs). Incentive is based on number of ECMs installed.”

Conclusion/Summary Increased kWh savings requested based on: ◦Installed motor mix of motors > 9 watts » Based on actual PNW program invoices ◦Weighting of medium temp vs. low temp cases » Based on actual GrocerSmart audit data Approval for deemed kWh savings of 453 kWh/motor