Detector Response Measurements Presented by Dr. Richard Young VP of Marketing & Science Optronic Laboratories, Inc.

Slides:



Advertisements
Similar presentations
Micron detector testing in Liverpool G. Casse – O. Lodge Laboratory, University of Liverpool.
Advertisements

Dr. Richard Young Optronic Laboratories, Inc.
S A D A R S Stevenage And District Amateur Radio Society
Edge Sensors for the Schwarzschild-Couder Telescopes David Hanna McGill University UCLA AGIS Meeting June 26-27, 2008.
LASP/TRF diagnostic test and results for the ACRIM3 experiment Implications for the multi-decadal TSI database ACRIMSAT/ACRIM3 ACRIM3 TEAM Dr. Richard.
OL 750 Diffuse Spectral Reflectance Measurement System
ICSO High Accuracy Laser Telemetry for Kilometric Distance Measurement in Space C.COURDE, H. PHUNG Duy, M. LINTZ, A. BRILLET ARTEMIS, Observatoire.
1 Detector meeting, Cascina, Quadrant diode configuration ‘X’ or ‘+’ configuration? ISYS quadrant diodes.
Source Measurement The most common measurements of sources include:  Radiance - Light emitted in a particular direction  Irradiance – Light falling onto.
INTEGRATED CIRCUITS Dr. Esam Yosry Lec. #6.
Spectroscopy of Saturn
Semiconductor Light Detectors ISAT 300 Foundations of Instrumentation and Measurement D. J. Lawrence Spring 1999.
OL 750 Measurement Systems
Photodetector.
ASIC3 WorkshopLandsdowne, VA May 16-18, 2006 J. Harder Page 1 Calibration Status of the Solar Irradiance Monitor (SIM) : The Present and the Future Jerald.
1 Detectors RIT Course Number Lecture Single Element Detectors.
1 Lab Equipment. 2 TopicSlides DC Power Supply3-4 Digital Multimeter5-8 Function Generator9-12 Scope – basic controls13-20 Scope – cursors21-24 Scope.
The Forbidden Transition in Ytterbium ● Atomic selection rules forbid E1 transitions between states of the same parity. However, the parity-violating weak.
Radiance to Irradiance Conversion Training Level: Intermediate
USE OF THE OSCILLOSCOPE Modified from a presentation written by David Matzke by: Donald Wisniewski, Dawn Wisniewski, Huzefa Mamoola and Angela Nolte Under.
Atomic Absorption Spectroscopy
Power Stabilization of the 35W Reference System Frank Seifert, Patrick Kwee, Benno Willke, Karsten Danzmann Max-Planck-Institute for Gravitational Physics.
CUÑADO, Jeaneth T. GEQUINTO, Leah Jane P. MANGARING, Meleria S.
Miriam Pekar Alex Liberchuk Supervisors: Dr. Alexander Fish Mr. Arthur Spivak 10/2011 P
Wave Nature of Light Physics Group: Alex Pearson, Travis Christolear, Mei Mei Chan, Colin Smith Faculty Advisors: Vladimir Gasparyan, Thomas Meyer Experimental.
Thermal noise issues Chinyere Ifeoma Nwabugwu Louisiana State University August 05, 2005 Eric Black, Akira Villar, Kenneth G. Libbrecht, Kate Dooley, Royal.
Dr. Richard Young Optronic Laboratories, Inc..  Uncertainty budgets are a growing requirement of measurements.  Multiple measurements are generally.
Transmittance Measurement Presented by Dr. Richard Young VP of Marketing & Science Optronic Laboratories, Inc.
Status of QBPM Electronics and Magnet Movers as of June 3 rd 2008 D. McCormick, J Nelson, G White SLAC S Boogert Royal Holloway Y. Honda, Y.Inoue KEK.
1 Optocouplers. 2 LED for emitter Air as barrier for isolation Phototransistor for detector Transformer is similar, but only for AC Optocoupler can be.
Spectrophotometer Prof.Dr. Moustafa M. Mohamed Vice Dean Faculty of Allied Medical Science Pharos University in Alexandria, EGYPT.
The Future of NVIS Display Measurement ALI Advanced Seminar, 2006Optronic Laboratories Dr. Richard Young Optronic Laboratories, Inc.
1 Atomic Absorption Spectroscopy Lecture Emission in Flames There can be significant amounts of emission produced in flames due to presence of flame.
Sphere Standards and Standard Spheres Dr. Richard Young Optronic Laboratories, Inc.
Optronic Laboratories Inc. OL Series 750 Automated Spectroradiometric Measurement System Optronic Laboratories Inc. OL Series 750 Automated Spectroradiometric.
Simple Double Beam Spectrometer
MOCT(Magneto Optic Current Transduser)
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 19 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
Martin Hewitson Overview of DC work. GEO DC workshop June DC work Noise characterisation Noise projections, noise sources, noise couplings Calibration.
 Presents the user with actual light values, not electrical signals  Accommodates multiple measurement types and conditions  Stand-alone operation and.
8 July 1999A. Peisert, N. Zamiatin1 Silicon Detectors Status Anna Peisert, Cern Nikolai Zamiatin, JINR Plan Design R&D results Specifications Status of.
Controller Design of Power Quality-Improving Appliances PNNL-SA D. J. Hammerstrom, N. Zhou, and N. Lu Pacific Northwest National Laboratory 902 Battelle.
OL 750 Measurement Systems OL 750 Measurement Systems Optronic Laboratories, Inc.
The law of reflection: The law of refraction: Image formation
BeamCal Electronics Status FCAL Collaboration Meeting LAL-Orsay, October 5 th, 2007 Gunther Haller, Dietrich Freytag, Martin Breidenbach and Angel Abusleme.
HBD Gas System and Monitoring Craig Woody BNL HBD Working Group Meeting December 8, 2004.
WFC3 SMOV Report for TIPS 16 July 2009 John MacKenty This presentation contains material that is embargoed until after the SM4 ERO press conference. Images/spectra.
Tracking and Probing Single, Diffusing Molecules in Droplets Mark Arsenault, Peker Milas, Ben Gamari, Richard Buckman, Lori Goldner Biophysics Group MiniSymposium.
TCT measurements with irradiated strip detectors Igor Mandić 1, Vladimir Cindro 1, Andrej Gorišek 1, Gregor Kramberger 1, Marko Milovanović 1, Marko Mikuž.
Speaker: Hao-Wen Chuang ( 莊浩彣 ) Advisor: Assistant Prof. Chung-Hao Tien Assistant Prof. Yi-Pai Huang Display Institute, National Chiao Tung University,
Flex Cable Readout unit Si Sensor 256 analog lines Interconnect board NCC signal packaging concept PA board -This is the calorimeter – all pads in the.
High Gain Transimpedance Amplifier with Current Mirror Load By: Mohamed Atef Electrical Engineering Department Assiut University Assiut, Egypt.
Current Status of QBPM Electronics and Magnet Movers D. McCormick, J Nelson, G White SLAC S Boogert Royal Holloway Y. Honda, Y.Inoue KEK.
CCD Calibrations Eliminating noise and other sources of error.
Digital Light Sources First introduced in 2001.
Simple Double Beam Spectrometer
PIC CONTROLLED DYNAMIC TIME BASED CITY TRAFFIC SIGNAL
Practical advices for using TCT (mostly for Particulars setups)
Laser Safety Laser Beam Containment Effects from beam exposure
Charge Transfer Efficiency of Charge Coupled Device
DENSITY BASED TRAFFIC LIGHT TIMING CONTROL
Some of the basic terms related to both film and digital cameras:
Spectrophotometer Dr . S. Jayakumar.
ARDUINO LINE FOLLOWER ROBOT
Homodyne readout of an interferometer with Signal Recycling
BESIII EMC electronics
Art Appreciation- Tuesday:
OL 750 Measurement Systems
Spectroscopy Uses emission and absorption of light by electrons moving between ground and excited state configuration, hence electronic configuration.
OL 750 Spectroradiometer & Linear Spectral Transmission Measurements
Presentation transcript:

Detector Response Measurements Presented by Dr. Richard Young VP of Marketing & Science Optronic Laboratories, Inc.

Outline of Presentation  Detector Types  Response Uniformity  Measurements  Irradiance Response By substitution  Power Response By substitution By beam switching

Detector Types Detectors generally fall into two main types PhotodiodesPhotoconductors

Detector Types  Photodiodes  Can operate unbiased or biased  Are generally suited to DC amplification  Have low noise  Generally operate in the UV to near IR  Photoconductors  Must be biased to operate  Are usually operated in AC mode  Have low sensitivity and high noise  Generally operate in the visible to far IR

Response Uniformity Photodiodes often have uniform responsivity Note: the z-axis scale is in 0.1% increments

Response Uniformity Photoconductors often have non-uniform responsivity Note: the y-axis scale is in 10% increments

Response Uniformity Signal For the silicon photodiode, the signal is virtually the same regardless where on the chip the light spot falls.

Response Uniformity Signal For the PbS photoconductor, the signal is very different, depending where on the chip the light spot falls.

Power Response  Power is measured correctly at all locations on the chip  Power is measured correctly at all spot sizes  Provided the spot lies within the detector area  The spot location on the chip and spot size that was used in the detector calibration must be reproduced exactly for correct measurements Si Detector PbS Detector If the detectors were calibrated, we could measure the power [W] in the spot, but…

Irradiance Response If the spot is larger than the detector area, the detector measures PowerArea = Irradiance (watt/cm 2)

Irradiance Response Provided the intensity within the spot is uniform, the PbS detector also gives correct irradiance results and is not sensitive to alignment or spot size.

Detector calibration is usually done by direct substitution. For irradiance response calibration, the detector is over-filled with a uniform beam Calibrated Detector First, the irradiance [W/cm 2 ] is measured with the calibrated detector Test Detector Then the signal on the test detector gives its irradiance response [(A or V)/(W/cm 2 )] Irradiance Response

Power reponse calibration is also usually done by direct substitution. For power response calibration, the detector is under-filled with a small spot Calibrated Detector First, the power [W] is measured with the calibrated detector Test Detector Then the signal on the test detector gives its power response [(A or V)/W] Power Response

 However, if the detector is non-uniform, it needs to be positioned correctly each time.  Often the test detector and the calibrated detector require different holding fixtures. And changing these, with alignment adjustments, every time you need to calibrate can be time consuming.  An accessory with a beam switch can speed up the calibration/measurement cycle considerably.

Detector measurements with a beam switch requires one extra step. First, the calibration as normal… Calibrated Detector Power Response …then the beam is switched and the calibrated (or other) detector is placed at the switched position…

Calibrated Detector Power Response Measurement of the detector response in THIS position is called a transfer calibration.

Once this is done, the detector remains in this position. Calibration is achieved by applying the transferred values. Calibrated Detector Power Response

Measurement is the same as before with the mirror switched back. Calibrated Detector Power Response Test Detector