Application of a 2-D ionization chamber array for dose verification of dynamic IMRT with a micro-MLC Fujio ARAKI, PhD 1, S. TAJIRI 2, H. TOMINAGA 2, K.

Slides:



Advertisements
Similar presentations
Cirrone G. A. P. , Cuttone G. , Raffaele L. , Sabini M. G
Advertisements

Ionization Chamber Array for External Beam Radiotherapy
RapidArc plan verification using ArcCHECK™
Commissioning an Anthropomorphic Spine and Lung Phantom for Remote Dose Verification of Institutions Participating in RTOG 0631 Douglas Caruthers, M.S.;
Alexander Klyachko, IU Cyclotron, PTCOG51, Seoul, South Korea, May 17-19, 2012 A.V. Klyachko 1, D.F. Nichiporov 1, L. Coutinho 2, C.-W. Cheng 2, 3, M.
Photon Beam Monitor-Unit Calculations
Lotte Verbunt Investigation of leaf positioning accuracy of two types of Siemens MLCs making use of an EPID.
Measurement of Absorbed Dose (6)
Introduction The effect of air-cavities within the human body, for example in the head and neck regions, present possible sources of error when calculating.
A pixel chamber as beam monitor for IMRT S. Belletti 4, A.Boriano 6, F.Bourhaleb 5,7, R. Cirio 6, M. Donetti 5,6, B. Ghedi 4, E. Madon 2, F. Marchetto.
Performances of a pixel ionization chamber to monitor a voxel scan hadron beam A.Boriano 3, F.Bourhaleb 2,3, R. Cirio 3, M. Donetti 2,3, F. Marchetto 3,
Quality Control Rad T 110.
Dose Distribution and Scatter Analysis
Dosimetric evaluation of a new design MOSFET detector Per H. Halvorsen* & Stephanie Parker University of North Carolina.
Results The measured-to-predicted dose ratio criteria used by the RPC to credential institutions is , however for this work, a criteria of
Michele Togno ARDENT ESR 11 – 2D Ionization Chambers Array for Clinical Applications Michele Togno – ARDENT midterm review preparatory meeting, CERNJune,
TWO FIELD BREAST PLAN VS. OPTIMIZED CONFORMAL BREAST PLAN: COMPARISON OF PLAN PARAMETERS Authors: Borko Basarić, Ozren Čudić, Milan Teodorović, Borislava.
Quality Control in Radiation Therapy, A New Concept: Dosimetry Check
Научно-практический центр протонной лучевой терапии и радиохирургии (Москва-Дубна) A SYSTEM FOR MEASUREMENT OF A THERAPEUTIC PROTON BEAM DOSE DISTRIBUTION.
External Beam Radiotherapy
Test of the proposed method Introduction CCD Controller CCD Illuminator gel Filter 585nm Assembling the phantom before its irradiation. The phantom, ready.
AUTHORS (ALL): Huang, Xiaoyan 1, 2 ; Kuan, K M 2 ; Xiao, G L 2 ; Tsao, S Y 3, 2 ; Qiu, X B 2 ; Ng, K 2. INSTITUTIONS (ALL): 1. Radiation Oncology, Sun.
Kelly Younge, Ph.DKelly Younge, Ph.D Don Roberts, Benedick Fraass, Daniel McShan, and Martha Matuszak University of Michigan, Department of Radiation Oncology,University.
In vivo dosimetry Eirik Malinen Eva Stabell Bergstrand Dag Rune Olsen.
Surface dose prediction and verification for IMRT plans using line dose profiles † Ronald E. Berg, † Michael S. Gossman and ‡ Stephen J. Klash † Erlanger.
The Magic Cube and the Pixel Ionization Chamber: detectors for monitor and dosimetry of radiotherapy beams S. Amerio 1, A. Boriano 2, F. Bourhaleb 2,3,
Introduction Since 1996 [1], it has been clear that optical computed tomography (CT) represents a viable alternative to MRI scanning of dosimeter gels.
May 31, th PTCOG in Catania, Italy1 Treatment Planning for Broad-Beam 3D Irradiation Heavy-Ion Radiotherapy N. Kanematsu, M. Endo, and T. Kanai,
Institute for Advanced Radiation Oncology
Medical Accelerator F. Foppiano, M.G. Pia, M. Piergentili
Araki F. Ikegami T. and Ishidoya T.
Investigation of 3D Dosimetry for an Anthropomorphic Spine Phantom R. Grant 1,2, G. Ibbott 1, J. Yang 1, J. Adamovics 3, D Followill 1 (1)M.D. Anderson.
AIR CORE SCINTILLATION DOSIMETER SUMMARY We have shown that Cerenkov light can be reduced to a negligible level in scintillation dosimetry by using an.
A solution for dosimetry and quality assurance in IMRT and hadrontherapy: the pixel ionization chamber. S. Amerio a, S. Belletti b, A. Boriano c, R. Cirio.
Alexis Dimitriadis Prof Karen Kirkby Prof Andrew Nisbet Dr Catharine Clark Dr Anthony Palmer.
Introduction The Radiological Physics Center (RPC) anthropomorphic quality assurance (QA) phantom program is one tool the RPC uses to remotely audit institutions.
F. Foppiano, M.G. Pia, M. Piergentili
Francesca Bisello, Prague , IV ARDENT Workshop IV ARDENT Annual Workshop 22-26/06/2015 Prague Francesca Bisello ESR 10.
TLD POSTAL DOSE QUALITY AUDIT FOR 6MV AND 15MV PHOTON BEAMS IN RADIOTHERAPY CLINICAL PRACTICE Sonja Petkovska 1, Margarita Ginovska 2, Hristina Spasevska.
FrontierScience G.P.1 MATRIX an innovative Pixel Ionization Chamber for Online Monitoring of Hadrontherapy Treatments Giuseppe Pittà.
Implementation of a New Monte Carlo Simulation Tool for the Development of a Proton Therapy Beam Line and Verification of the related Dose Distributions.
Purpose N-isopropylacrylamide (NIPAM) polymer gel dosimeters were employed to verify the dose distribution of clinical intensity modulated radiation therapy.
Thickness of CZT detector 110 MeV140 MeV DETECTOR A (1 mm CZT + 5 mm CZT) DETECTOR B (1 mm CZT + 10 mm CZT) DETECTOR C (1 mm CZT + 15 mm CZT) A. Generation.
1 A protocol for the determination of absorbed dose from high energy photon and electron beams AAPM TG-21 Protocol (Med Phys 10: , 1983) 和信治癌中心醫院.
Commissioning of a commercial treatment planning system for IMAT and Dose Painting treatment delivery. G. Pittomvils 1,,L. Paelinck 1, F. Crop 2, W. De.
1 3rd oPAC Topical Workshop on Beam Diagnostics, CIVIDEC, Vienna, 8th-9th May 2014.
The Effects of Small Field Dosimetry on the Biological Models Used In Evaluating IMRT Dose Distributions Gene Cardarelli,PhD, MPH.
Rapid Arc Treatment Verification: post evaluation on Delta-4 and proposal of a new verification protocol G. Pittomvils 1,,L. Paelinck 1, T. Boterberg 1,
Date of download: 6/23/2016 Copyright © 2016 SPIE. All rights reserved. (a) Relative positions of the linear accelerator (LINAC) gantry, treatment region,
Adapting A Clinical Medical Accelerator For Primary Standard Dosimetry
Development of elements of 3D planning program for radiotherapy Graphical editor options  automated enclose of contour  correction of intersections 
E. Mezzenga 1, E. Cagni 1, A. Botti 1, M. Orlandi 1, W.D. Renner 2, M. Iori 1 1. Medical Physics Unit, ASMN-IRCCS of Reggio Emilia, Italy 2. MathResolution.
CONFIDENTIAL MATERIAL Michele Togno - II Annual ARDENT Meeting, Milan – October, 14 th D Ionization Chambers Array for Clinical Applications.
Qing Liang, PhD Medical Physicist Mercy Health System, Janesville, WI
Chapter 5 Central Axis Depth Dose Calculations. 2 Definition of Beam Geometry The accurate delivery of a radiation dose to patient depends on the precise.
CHAPTER 3 DOSE DETERMINATION FOR EXTERNAL BEAMS
Dr: Mohamed Afifi By Lecturer Radiological Science
Absolute Dose Measurement
Influence of the grid size on the dosimetric characteristics of IMRT beams and on overall treatment plans G. Pittomvils1, L. Olteanu1, B. Vanderstraeten1,
A system of dosimetric calculations
A Prototype Microstrip Dosimeter for Characterisation of Medical
Development and characterization of the Detectorized Phantom for research in the field of spatial fractionated radiation therapy. D. Ramazanov, V. Pugatch,
Template Matching Can Accurately Track Tumor Evaluation of Dose Calculation of RayStation Planning System in Heterogeneous Media Huijun Xu, Byongyong Yi,
A. Nisbet 1,2, A. Dimitriadis 1,2,3, A.L. Palmer 1,4, C.H. Clark 2,3
Arghya Chattaraj, T. Palani Selvam, D. Datta
Insert tables Insert figure
Dosimetry of Alternative Techniques for Accelerated Partial Breast Irradiation Hanh Pham, B.S, CMD, Thanh Nguyen, BS, Christina Henson, MD, Salahuddin.
Ch 10. A System of Dosimetric Calculations
Relationship between dosimetric leaf gap and dose calculation errors for high definition multi-leaf collimators in radiotherapy  Jinkoo Kim, James S.
GHG meeting at ESTRO36 May, 2017
Presentation transcript:

Application of a 2-D ionization chamber array for dose verification of dynamic IMRT with a micro-MLC Fujio ARAKI, PhD 1, S. TAJIRI 2, H. TOMINAGA 2, K. KAWASAKI 2, K. KOGO 2, M. YOSHITANI 3, N. ARAKI 3, L. Müller 4 1 Kumamoto University School of Health Sciences, Kumamoto, Japan, 2 Kumamoto Radiosurgery Clinic, 3 Toyo Medic Co., Ltd., Tokyo, Japan, 4 Scanditronix Wellhöfer GmbH, Schwarzenbruck, Germany BACKGROUND A pixel-segmented ionization chamber, MatriXX, (Scanditronix Wellhöfer, Germany), has been designed to ease the two-dimensional (2D) verifications of fields with complex shapes like intensity modulated radiation therapy, IMRT. The detector features a 24×24 cm 2 active area divided in 1020 independent plane parallel ionization chambers. The sensitive volume of each signal ionization chamber is 0.07 cm3 (4.5 mm diameter×5 mm height) and chamber-to-chamber distance is 7.62 mm). PURPOSE This study aims to examine dosimetric characteristics of MatriXX and its usefulness for dose verification of dynamic IMRT fields with a dedicated Novalis shaped beam radiosurgery unit equipped with a micro-multileaf collimator (mMLC: BrainLAB, Heimstetten, Germany). MARERIALS AND METHOD The absorbed dose for MatriXX was calibrated with a Farmer ionization chamber in a solid water phantom. The MatriXX response was tested as to dose linearity and dose rate dependence. Basic parameters of radiation beam (TPRs, OARs, output factors) were compared with ionization chamber measurements for a 6 MV photon beam. The spatial resolution of MatriXX was tested using a bar pattern of mMLC with 3, 4.5, 5.5 and 10 mm wide at isocenter. The analysis of measured (MatriXX and ionization chamber) and calculated absorbed dose distributions were performed for complex dynamic IMRT fields. The dynamic IMRT dose distribution was calculated with the BrainSCAN 3-D treatment planning system (BrainLAB, Heimstetten, Germany) for stereotactic radiotherapy (SRT) fields formed by mMLC. Fig. 1 TPR and output factor data obtained for a 6 MV x-ray beam using an ionization chamber and MatriXX in a solid water phantom. The output factors for small fields less than 2 x 2 cm 2 were measured with a diode detector (SFD). RESULTS AND DISCUSSION The dose response of MatriXX is linear in the range Gy. The dose rate dependence is within 0.1% in the range Gy/min. The TPR and OAR data measured in a 6 MV photon beam is in good agreement with ionization chamber measurements (Figs. 1(a) and 2). Output factors measured with MatriXX and an ionization chamber agree within 1% for field sizes in the range from 1.2×1.2 cm 2 to 10×10 cm 2 (Fig. 1(b)). The spatial resolution of MatriXX is 7.62 mm, which cannot recognize the bar pattern of 3 mm, as it contains spatial frequencies much higher than MatriXX’s intrinsic resolution (Figs. 3(d) and (e)). The bar pattern of 4.5 and 5.5 mm can be recognized by MatriXX but the dose profile does not contain the full modulation due to limited spatial resolution (Figs. 3(d) and (e)). The MatriXX profile agrees with that of RTPS for the 10 mm bar pattern (Figs. 3(a)~(c)). A direct comparison can be made between dose profiles measured with MatriXX and the calculated dose profiles of RTPS when they are integrated to the same spatial resolution of 7.62 mm (Fig. 4). With this method, excellent agreement can be achieved between planned data and measurement with MatriXX. In dose verification of IMRT fields, MatriXX agrees with those of RTPS in the region where the dose slope is gentle, while it shows some difference from the dose distributions by RTPS in the steep slope regions (Figs. 5 and 6). This is because the dose distribution cannot be faithfully reflected in the linear interpolation in relation to the resolution due to the arrangement of MatriXX ionization chambers (at 7.62 mm intervals). CONCLUSIONS The pixel-ionization-chamber 2D-MatriXX is found to be able to measure the given dose (absolute dose) and dose distributions simultaneously. It is useful for dose verification of dynamic IMRT pre-treatment. As a word of caution, the limited number of detectors and the dimension of a single detector have to be always kept in mind when dealing with very high gradient or very small field sizes formed with mMLC, but within these limitations it can be still used for the verification of these fields. Reference 1. S. Amerio, A. Boriano, F. Bourhaleb, et al., “Dosimetric characterization of a large area pixel-segmented ionization chamber,” Med, phys. 30, (2004). 2. M. Stasi, S. Giordan, R. Cirio, “D-IMRT verification with a 2D pixel ionization chamber: dosimetric and clinical results in hed and neck caner.” Phys. Med. Biol. 50, (2005). Fig. 2 Comparison of beam profiles measured with an ionization chamber in a water phantom and with MatriXX in a solid water phantom. The irradiations were performed at d max and 20 cm, and for 4.2 x 4.2 cm 2 and 10 x 10 cm 2 field sizes in a 6 MV x-ray beam. The results are normalized to the central beam axis. Fig. 3 Comparison of dose profiles between MatriXX and RTPS tested using a bar pattern of mMLC with 3, 4.5, 5.5 and 10 mm wide at isocenter. Measurements were performed at a depth of 10 cm in a solid water phantom for a 6 MV x-ray beam, SSD=95 cm. The dose profile of RTPS is transferred to the same grid size (7.62 mm) as MariXX in figure of lower left. Fig. 5 Comparison of IMRT dose profiles between MatriXX and RTPS for before and after grid transform. The dose profiles of RTPS are transferred to the same grid size as MatriXX. Fig. 6 Comparison of IMRT dose profiles between MatriXX and RTPS. The dose profiles are evaluated by  D=3% and  d=3mm of “Gamma method”. (b) (d) (a) Procedure to compare MatriXX with RTPS. Fig. 4 Procedure to compare fluence map of MatriXX with RTPS’s for IMRT dose verification. Fig. (d) is final dose profiles of MatriXX and RTPS transferred to the same grid size. (c) (a) Original dose profiles of MatriXX and RTPS. (b) After transferring to the same grid size. (a) Original dose profiles. (b) After transferring to the same grid size. (a) TPR (b) Output factor (a) depth=1.5 cm (b) d=20 cm (a) (b) (c) (d) (e)