EEG Biofeedback Device Ashley Anderson, Michelle Lorenz, Shikha, Ryan Thome, Chris Wegener Client: Dr. Daniel MullerAdvisor: John Webster.

Slides:



Advertisements
Similar presentations
ENGN Engineering Design
Advertisements

MIAMI Research Group Electrical and Computer Eng. Dept. MIAMI Medical Instrument Analysis and Machine Intelligence
Biofeedback and Stress Management. Design and build an inexpensive and portable electroencephalogram for use during meditation. The device must provide.
Biofeedback Jennifer L. Doherty-Restrepo Entry-level Athletic Training Education Program PET 4995: Therapeutic Modalities.
Noise and Interference Reduction Joel Neher and Linshu Li.
Introduction to Network (c) Nouf Aljaffan
Microelectronics System Design for Chronic Brain Implants ECEN 5007 S. Johnson, V. Ganesan
EEG Machine By The All-American Boys Featuring Slo- Mo Motaz Alturayef Shawn Arni Adam Bierman Jon Ohman.
Ultrasonic Testing This technique is used for the detection of internal surface (particularly distant surface) defects in sound conducting.
Detailed Design Review Project P13363 Members: Justine Converse (IE) James Cover (CE) Alexander Eschbach (EE) Jason Hang (ME) Ashley Trode (EE) Guide:
Electromyography: Recording D. Gordon E. Robertson, Ph.D. Biomechanics Laboratory, School of Human Kinetics, University of Ottawa, Ottawa, CANADA.
Chip Carrier Package as an Alternative for Known Good Die
At-Home Sleep Staging Device Progress Presentation Presented by: Kiron Sukesan Team Members: Matthew Hwang, Yinong Wang Clients: Dr. Lucey and Dr. Ju Mentor:
Final Presentation James Lin Son Phan Michael Oduselu
BALLISTIC PARTICLE MANUFACTURING (BPM)
A seminar on Addiction avoider
Design Project – Final Phase Team 9: Rishabh Agarwal Keith Chan Anton Galkin Ashwin Kapur.
7.1 Chapter 7 Transmission Media. 7.2 Figure 7.1 Transmission medium and physical layer Transmission media are located below the physical layer and are.
EMG Biofeedback Device BME 200/300 Fall 2003 Department of Biomedical Engineering University of Wisconsin-Madison.
Design Product Analysis. What is a product analysis? Why is it used? How do you do a product analysis ?
Song Pro Retro Alex Harper. Contents of Presentation Inspiration Basic Concept Speaker Module.sng file structure Song Pro Retro: Light Song Pro Retro:
The AWE Family Includes Joyal® – A Division of AWE, Inc.
G.K.BHARAD INSTITUTE OF ENGINEERING DIVISION :D (C.E.) Roll Number :67 SUBJECT :PHYSICS SUBJECT CODE : Presentation By: Kartavya Parmar.
IV Tubing Organizer Blake Hondl, Amit Mehta, Ryan Pope, Kristen Sipsma, April Zehm, Katie Zenker BME 200/300 October 10, 2003.
Da’Janel Roberts Matthew Morgan Jonathan James
University of Wisconsin – Madison University of Wisconsin – Madison Engineering Projects In Community Service BIOFEEDBACK / STRESS MANAGEMENT May 9, 2001.
1 E906 Pre-Amplifier Card 2009/10/07. 2 E906 Wire Chambers Station1 MWPC: –build a new E906 MWPC. –4500 channels in total. Station2 DC: –recycle old E866.
Physical Transmission
Introduction to Network (c) Nouf Aljaffan
CSCI 465 Lecture 5 Martin van Bommel CSCI 465 Data Communications and Networks 1.
Biofeedback and Stress Management BME 402 Spring 2004.
Introductory Client: Herb Harmison 2692 Meadow Glen Road Ames, IA Faculty Advisor: Edwin Jones Jr. Team Members: Hassan Qureshi CprE Hamdan Al-Mehrezi.
Tactile Auditory Sensory Substitution Ryan Thome, Sarah Offutt, Laura Bagley, Amy Weaver, Jack Page BME 200/300 October 20, 2006.
BICYCLE CELL PHONE CHARGER Senior Design Project Team: Ajeetesh Govrineni (EE), Kellen Warriner (IE), Chris Battaglia (ME) Guide: John Kaemmerlen.
Electromyography (EMG)
Engineering Chair Design
IPC-2221 Connectors and Interconnects
What is EEG ? An electroencephalograph (EEG) is the recorded electrical activity generated by the brain. In general, EEG is obtained using electrodes placed.
Probing The Of. Experience Pain Pain Team Members Jeff Swift Anna Karas Stacey Hoebel Advisor Prof. Willis Tompkins Client Dr. Christopher Coe UW-Madison.
OUTLINE Introduction of BCI EEG signal SSVEP BCI System Application.
Displacement and Motion Measurement
Probing Pain Perception Client: Christopher Coe, Ph.D. Department of Psychology Advisor: Professor Willis Tompkins Team Members: Stacey Hoebel, Jeff Swift,
Mind Control of Systems Designing a system to measure brain waves in order to obtain commands to control the direction of a remote-control car By Gary.
EMG Biofeedback Device BME 200/300 Fall 2003 Department of Biomedical Engineering University of Wisconsin-Madison.
D-Oily Tools 02/01/06 Week 4 Deliverables Aaron Lunt Adam Kan Justin Chastang Richard Burge Michelle Siverd Tyler Warnock Conceptual Design.
Portable Real Time ECG Design
New Product Development Management NPDM 6 Mohsen SADEGHI Department of Graduate School of Management and Economics Sharif University of Technology.
Transmission Media The transmission medium is the physical path by which a message travels from sender to receiver. Computers and telecommunication devices.
BY Parmar Anjali Singh Sweta
Spot Welder BY MOHAMED ABUZAID. Design Brief I will be building a spot welder. My spot welder will be able to weld two metal pieces together using electric.
Fig. 1: Portable meditation biofeedback device in use: (1.a) Headband, including amplification component and detachable Ag/AgCl electrodes. (1.b) Bioamplifier.
Biofeedback and Stress Management John Harrison – Leader Albert Kwansa – Communicator Eric Lee – BSAC Brenton Nelson – BWIG Dr. Daniel Muller – Client.
Ophthalmic Dose Compliace Monitor. Our Team Benjamin Roedl – Team Leader Benjamin Roedl – Team Leader Nina Lewis – Team Leader Nina Lewis – Team Leader.
Tactile Auditory Sensory Substitution Jimmy Fong, Jack Page, Becky Jones, Ryan Thome, and Matt Valaskey Client: Veronica H. Heide, Au.D. Advisor: Mitchell.
Electric Pressure Transducer
Physiologic signals Lecture (2).
EEG Biofeedback Team: Cullen Rotroff, Andrew Eley,
Professor John Webster, Advisor
Physical Transmission
Physical Transmission
Physical Transmission
Physical Transmission
Chapter 7 Transmission Media.
Transmission Media.
Peak Inspiratory and Expiratory Flow Meter
Physical Transmission
Kimberly Gonzalez United Engineering & Technology Magnet
The EZG Portable | Easy to Use | Comfortable | Lightweight | Accurate | Versatile | Safe Structure of Prototype: Electrodes connect via snap leads to wings.
IF13 series: Power cord with Input EMC Filter
Physical Transmission
Presentation transcript:

EEG Biofeedback Device Ashley Anderson, Michelle Lorenz, Shikha, Ryan Thome, Chris Wegener Client: Dr. Daniel MullerAdvisor: John Webster

Problem Statement Design and build an inexpensive, portable electroencephalogram (EEG) that teaches meditation practitioners to achieve optimal meditation by the presence of EEG alpha and theta waves.

Meditation Proven form of alternative medicine Epilepsy Addiction AD/HD Mood Disorders Learned ability Allows self-detachment and relaxation

Electroencephalograph Measure surface voltage on the scalp Brain activity type inferred by frequency Target frequencies: Alpha (Relaxed) 8-15Hz Theta (Meditative) 4-7Hz

Design Constrains Handheld/Portable Inexpensive (<$100) Easy to use Must provide interpretable feedback Unintrusive Comfortable

Coaxial cable headband design overview + components Advantages: - Utilizes economical and user friendly materials (no lengthy preparation necessary) - Electrode arrangement desirable (frontal placement successful in previous groups) parts list headband elastic shielded audio cable male plastic coax plug Disadvantages: - Setup is rather bulky - Electrolyte solution is salt water, leaving evaporation as a major issue sponge ear plugs heat shrink tubing 5 pin DIN plug + socket table salt (electrolytic solution) Total cost ≈ 50 dollars

Coaxial cable headband design additions/improvements - Wedges as a component of the headband (either included in the band or added by us) to part the hair for better scalp contact or manufacture of individual electrodes utilizing concept of a simple hair clip/comb to move hair away from scalp - Electrolyte medium: current proposed mixture is messy, goal is a non-irritating solution or gel that reduces oil on scalp and maximizes conductivity

Pin Electrodes An array of metal conducting pins are fixed to an electrode base board. Between 16 and 32 holes are drilled in the base board and the pins are soldered in place from the back. Two separate electrodes are attached to a headband and held firmly against the scalp.

Pin Electrodes Advantages Does not require abrasive skin cleaning or messy conducting gels Pins are able to burrow through the hair and make direct contact with the scalp Electrodes are reusable Disadvantages Lack of conducting gel may result in poor signal quality Lack of adhesive leaves the electrode prone to sliding along the scalp, causing signal interference. Continued

Plate/Disc Electrodes Features:  Most commonly used electrode today in EEG biofeedback devices.  The disc electrodes consists of a flat disc generally of diameter 6mm – 10mm.  EEG disc electrodes feature a hole in the top for electrolyte injection.  Attached to color-coded shielded lead wires.  Cost: $85-90 (for Set of 6) References: Text: Figure 1: Figure 2 and 3: Figure 1 Figure 2 Figure 3

Plate/Disc Electrodes ADVANTAGES: Easy to make (just buy them!) Passive Electrodes Pleasing Aesthetics DISADVANTAGES: Bad conductivity and signal Difficult to use/meditate Dependence on gel Expensive: Extra cost of gel Difficult to clean Figure 1 Figure 2 Reference: Figure 1: Figure 2: Continued

Amplifier Constraints Low cost Clear, accurate signal Portable Battery powered Minimal size and weight Safe to use

Amplifier Design High input impedance Common Instrumentation Amplifier Design High CMRR, amplify 50 μ V P-P 4 – 15Hz Frequency Bandwidth

Ease of manufacture Comfort Preparation simplicity CostAesthetics Durability (reusability) Overall Coaxial cable headband Pin electrodes Plate electrodes Comparison of electrode designs Coaxial cable and pin electrodes both reasonably match our project design goals, but further differentiation will depend upon signal strength and quality which we hope to learn from future experiments. Scale from 1 (lowest) to 10 (highest)

Future Work Decide on digital or analog signal processing Choose feedback mechanism Test electrode signal quality Build amplifier prototype

Questions?