An Introduction to Quality Assurance in Analytical Science Dr Irene Mueller-Harvey Mr Richard Baker Mr Brian Woodget.

Slides:



Advertisements
Similar presentations
Chapter 7 Chemical Quantities
Advertisements

Errors in Chemistry Experiments Rohana Sirimanna.
WHO - PSM Documentation – Part 2 Workshop on GMP and Quality Assurance of TB products Kuala Lumpur Malaysia, 21 – 25 February 2005 Maija Hietava M.Sci.Pharm.
Measurements and Their Uncertainty 3.1
1 Contact details Colin Gray Room S16 (occasionally) address: Telephone: (27) 2233 Dont hesitate to get in touch.
An Introduction to Quality Assurance in Analytical Science
An Introduction to Quality Assurance in Analytical Science
An Introduction to Quality Assurance in Analytical Science
Effectively applying ISO9001:2000 clauses 6 and 7.
Experimental Measurements and their Uncertainties
Instrumental Analysis
Volumetric Analysis (Titration). What is it? The concentration of solutions of acids and bases can be determined accurately by a technique called volumetric.
The Six Phases of a Project
Prentice-Hall © 2002 General Chemistry: Chapter 4 Slide 1 of 29 Philip Dutton University of Windsor, Canada Prentice-Hall © 2002 Chapter 4: Chemical Reactions.
Errors in Chemical Analyses: Assessing the Quality of Results
Applied Example of Random and systematic errors in titrimetric analysis: The example of the students’ titrimetric experiments showed clearly that random.
World Health Organization
Chapter 3 – Volumetric Analysis Week 1, Lesson 1.
Limitations of Analytical Methods l The function of the analyst is to obtain a result as near to the true value as possible by the correct application.
Data Handling l Classification of Errors v Systematic v Random.
A Statistical Approach to Method Validation and Out of Specification Data.
Uncertainty analysis is a vital part of any experimental program or measurement system design. Common sources of experimental uncertainty were defined.
CHEM-3245 Quantitative Analysis
Chemometrics Method comparison
Validation of Analytical Method
© 2010 Cerilliant Corporation | 811 Paloma Drive | Round Rock, TX Uncertainty in the micro-ROI measurement was estimated following the guidelines.
Errors and Uncertainties © Christopher Talbot and Cesar Reyes 2008
IB Chemistry Chapter 11, Measurement & Data Processing Mr. Pruett
Introduction to ISO New and modified requirements.
CHEMISTRY ANALYTICAL CHEMISTRY Fall Lecture 4.
IB Internal Assessment Design. Designing an Experiment Formulate a research question. Read the background theory. Decide on the equipment you will need.
Chemistry II Chemical Reactions Principles and Modern Applications
The following minimum specified ranges should be considered: Drug substance or a finished (drug) product 80 to 120 % of the test concentration Content.
Analytical chemistry MLAB 243 Level 4 Lecture time: every WED 8 -10
Lesson Starter Look at the specifications for electronic balances. How do the instruments vary in precision? Discuss using a beaker to measure volume versus.
Flashback Convert 2.58 m to kilometers. Accuracy and Precision Accuracy- the closeness of measurements to the correct value of the quantity measured.
Uncertainty Estimation of Analytical Results in Forensic Analysis Ing. Ján Hrouzek, Ph.D. * Ing. Svetlana Hrouzková, Ph.D. Hermes.
Chapter 5 Errors In Chemical Analyses Mean, arithmetic mean, and average (x) are synonyms for the quantity obtained by dividing the sum of replicate measurements.
Measurement Uncertainty Information in
MEASUREMENT OF VOLUME. OVERVIEW First some general principles Then, more detail about micropipettes.
Calculating and Interpreting Error in AS Chemistry Click on the speaker icon on the right to hear the sound file You will need to be able to here the.
 Uncertainty and Error in Measurement ©2010 Travis Multhaupt, M.S.,
Objectives Distinguish between accuracy and precision. Determine the number of significant figures in measurements. Perform mathematical operations involving.
Laboratory QA/QC An Overview.
Uncertainty of measurement & Technical Specifications SAAMF Roadshow Durban CSIR NML Eddie Tarnow Metrologist: Torque & Automotive 14 June 2006.
Validation Defination Establishing documentary evidence which provides a high degree of assurance that specification process will consistently produce.
Introduction The Equipment The Terms The Process Calculations
Preview Lesson Starter Objectives Accuracy and Precision Significant Figures Scientific Notation Using Sample Problems Direct Proportions Inverse Proportions.
Objectives Describe the purpose of the scientific method. Distinguish between qualitative and quantitative observations. Describe the differences between.
B. Neidhart, W. Wegscheider (Eds.): Quality in Chemical Measurements © Springer-Verlag Berlin Heidelberg 2000 W. WegscheiderValidation: an Example 1 Learning.
ERT 207 Analytical Chemistry ERT 207 ANALYTICAL CHEMISTRY Dr. Saleha Shamsudin.
Chapter 2 © Houghton Mifflin Harcourt Publishing Company Accuracy and Precision Accuracy refers to the closeness of measurements to the correct or accepted.
Uncertainty & Errors in Measurement. Waterfall by M.C. Escher.
UNCERTAINTY OF MEASUREMENT Andrew Pascall Technical Director Integral Laboratories (Pty) Ltd
Uncertainty and error in measurement
Chapter 1: The Nature of Analytical Chemistry
Recommended Guide for Determining and Reporting Uncertainties for Balances and Scales Val Miller NIST Office of Weights and Measures.
1 DATA ANALYSIS, ERROR ESTIMATION & TREATMENT Errors (or “uncertainty”) are the inevitable consequence of making measurements. They are divided into three.
Establishing by the laboratory of the functional requirements for uncertainty of measurements of each examination procedure Ioannis Sitaras.
Fundamentals of Analytical Chemistry Eighth Edition.
MECH 373 Instrumentation and Measurements
How to Calculate MU? By Sanjay Tiwari Chief Chemist
Section 1 Scientific Method
Laboratory Quality Control
An Introduction to Quality Assurance in Analytical Science
Chapter 3 – Volumetric Analysis
This teaching material has been made freely available by the KEMRI-Wellcome Trust (Kilifi, Kenya). You can freely download,
Chapter 2 Table of Contents Section 1 Scientific Method
Chapter 2 Preview Objectives Scientific Method
Quality Control Lecture 3
Presentation transcript:

An Introduction to Quality Assurance in Analytical Science Dr Irene Mueller-Harvey Mr Richard Baker Mr Brian Woodget

Part 5 - Expression of Results Contents: Validation, traceability and measurement uncertainty (slides 3,4) The what, why and how of measurement uncertainty (slides 5-15) Reporting results (slide 16,17) The presentation contains some animation which will be activated automatically (no more than a 2 second delay), by mouse click or by use of the page down key on your keyboard.

The Famous Trio: When expressing results of analytical measurements you will need to bear in mind the 3 inter-linking parameters of: VALIDATION TRACEABILITY MEASUREMENT UNCERTAINTY Has the method been validated and it is fit for purpose? Will the results be traceable to an accepted reference standard? How sure will you be of the accuracy of the results obtained?

About validation, traceability & measurement uncertainty As you have seen in Part 1 of this presentation, all analytical results have an error associated with them. Measurement uncertainty is an estimate of the potential size of that error and is affected by both the time and effort put into method validation and the traceability of standard reference materials and substances Note: refer to Part 2 of the presentation for a description of method validation and to Part 3 for a description of traceability

Measurement Uncertainty (1) Analysis of a sample of soil has shown it to contain mg/kg of lead Mean result from replicate analyses Estimate of the measurement uncertainty Note: accredited laboratories (ISO 17025) carrying out this analysis would need to be aware of the levels of uncertainty but would not necessarily have to present this data unless asked. So the result could well be presented as 30 mg/kg You need to consider from where the uncertainty is likely to arise

Measurement Uncertainty (2) Sources of uncertainty arise from ALL aspects of the analysis - these could include: Volumetric glassware Calibration standards sampling sample preparation instruments operator skill Potential sources of error

Measurement Uncertainty (3) To estimate the measure of overall uncertainty, errors likely to occur in all aspects of the analysis need to be taken into account in the form of individual standard deviations (SD). Data may be obtained from: manufacturers of equipment and reagents (e.g. balances, volumetric glassware, standard reagents etc) data from method validation estimates from the literature or from previous experience An overall estimate of the uncertainty can then be calculated by using accepted procedures. Analytical balance

Measurement Uncertainty (3a) The accuracy of an analytical balance is fundamental to all of the procedures carried out within an analytical laboratory. The balance should be capable of weighing accurately to mg and is the starting point for most measurements (sample weight, preparation of standards, method validation etc.) The balance must be calibrated periodically against weights traceable to the UK standard held at the National Physical Laboratory (NPL), and checked at least every day against a set of weights held in the laboratory, specifically for this purpose. All calibration data must be stored.

Measurement uncertainty (4) The uncertainty estimation process can be illustrated diagrammatically: SPECIFICATION - clear statement of what is being measured and the relationship between it and parameters on which it depends IDENTIFY UNCERTAINTY SOURCES - list sources for each part of the process or for each parameter QUANTIFY UNCERTAINTY COMPONENTS - estimate the size of each uncertainty component CONVERT TO STANDARD DEVIATIONS - express error component as a standard deviation CALCULATE THE COMBINED UNCERTAINTY RE-EVALUATE THE PROCESS IF NECESSARY

Measurement uncertainty (5) Standard uncertainties A measure of the SD of an uncertainty component [u(y)] - may be calculated from: experimental data accuracy guaranteed by a piece of equipment – e.g. balance accurate to % confidence which may be converted to a SD – pipette guaranteed to deliver ml. Although no confidence level has been stated, SD may again be calculated.

Measurement uncertainty (6) Combined uncertainties Dependent upon the type of analysis carried out, the standard uncertainties may be combined to produce a combined uncertainty [u c (y)] One of three equations may be used, the choice being dependent upon the complexity of the analysis and the relationship between the components parts A model equation must be devised which describes in simple algebraic terms the whole analysis process

Measurement uncertainty (7) The rules for estimating combined uncertainties depend upon the model algebraic equation devised to illustrate the analysis process. You only need consider two at the present time: Rule 1 - for models involving only a sum or difference of quantities eg. For y = a + b + c, the combined uncertainty is given by: [u c (y)] 2 = u(a) 2 + u(b) 2 + u(c) 2 Rule 2 - for models involving only a product or a quotient eg: For y = a.b.c or y = a/(b.c), the combined uncertainty is given by: [u c (y)/y] 2 = [u(a)/a] 2 + [u(b)/b] 2 + [u(c)/c] 2

Measurement uncertainty (7a) Example to illustrate a calculation involving rule 1 Suppose that you have four components (a, b, c, d) and you need to know their combined mass and the uncertainty associated with this mass. The following information is available: a = g, u(a) = g; b = g, u(b) = g c = g, u(c) = g d = g, u(d) = g Total mass (T) is given by: T = a + b + c + d = = [u c (T)] 2 = u(a) 2 + u(b) 2 + u(c) 2 + u(d) 2 = = u c (T) = Thus: T =

Measurement uncertainty (7b) Example to illustrate a calculation involving rule 2 You have performed an acid/base titration to measure the molarity (M) of a solution of HCl, by titration with a standard solution of KOH. The following information is known or was obtained during the titration C KOH = M, [u(C KOH ) = ] V KOH = ml, [u(V KOH ) = 0.032] V HCl = ml, [u(V HCl ) = 0.021] The equation for the calculation may be expressed as: C KOH X V KOH C HCl = = V HCl Each of the individual standard uncertainties needs to be expressed as an RSD so for: C KOH = / = V KOH = 0.032/25.54 = V HCL = 0.021/25.00 = Thus: u c (C HCl ) =[( ) 2 + ( ) 2 + ( ) 2 ] 1/2 X u c (C HCl ) = [ ] 1/2 X = X = M C HCl = M

Measurement uncertainty (8) Coverage factor In order to give confidence to the value for the combined uncertainty, the calculated value u c (y) is often multiplied by a coverage factor (k). For a 95% level of confidence the value of k is 2 [ See Students t test table] Note: a more complete description of the principles used for calculating uncertainties may be found in: Quantifying Uncertainty in Analytical Measurements, Eurochem, Quality in the Analytical Laboratory, E. Prichard (Ed), Wiley, 1995, Chapter 6.

Reporting results The test report of an accredited laboratory must conform to the requirements of the accreditation body - usually the report must clearly identify- - the laboratory -the client -the samples -the date they were received -the method of analysis -the analyst -the date of the report -the unique Test Report no. on every page The report format must ensure that there can be no confusion over which results refer to which samples and it should give any information about the condition of the samples that may have affected the test results.

Benevolent Department Well-intentioned Organisation Tel: Fax: Test report numberClient Test batch numberRecipient's name Date receivedDate reportedAnalyst Batch description Details of analyses Method is carried out in accordance with BS EN ISO/IEC standard Calibration data Comments SignedPrint name (authorised signatory) A UKAS accredited testing laboratory No. £$%& Amiable Laboratory mc218 A Client 02/01/02 09/01/02 C. T02 JAN Raw milks XYZAB Fat, Protein, Lactose by Milk-o-scan (FAL method 7.3.1) Typical calibration range for milk samples: Fat: % Protein: % Lactose: % 8 missing samples 51,99,100,135,138,145,164,189. £$%& TEST REPORT HEADER For Accredited Tests (example for demonstration only)