Description of various components/sub-assemblies.

Slides:



Advertisements
Similar presentations
Variable Frequency Drives Bypass Options
Advertisements

Sequential Process Control
Engineer Training Machine Electrical Cabinet TJ8300 / TJ8500 Machine Electrical Cabinet (EC)
Daikin Altherma™ Troubling Shooting
E1 – Electrical Fundamentals
HEAT PUMPS.
38GXC(Q)/40GXC(Q) Service Training Sizes 18 and 24K.
An Introduction to EV Wiring By Charlton Jones Gateway EV Washington, MO.
Graphic Symbol Location 1. DIN Terminal X52 The machine is powered by electricity using copper cable with 5 wires (3 phase wires + neutral wire +
BSA Electricity Merit Badge Electricity Merit Badge AC Alternating Current.
Engineer Training Electrical Cabinet (EC) TJ8300 / TJ8500 Electrical Cabinet (EC)
ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
Solar Charge Controller With Dump Load Circuit Built By Matt Smyrski.
Electrify Me! Electricity Basics.
© 2011 Ericson Manufacturing, Willoughby, Ohio
Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams
EGD ELECTRICAL ELECTRICAL SYMBOLS.
Freedom Combi Inverter
Engineer Training UV Electrical Cabinet (16 and above) TJ8300 / TJ8500 UV Electrical Cabinet (Machines 16 and above)
Engineering Practice Electric Fitting Resistance Electrical resistance is the ratio of voltage drop across a resistor to current flow through the resistor.
AS ICT.  Have an understanding of how organizations use ICT.  Be able to describe a number of uses, giving the hardware and software requirements. 
© 2006, ZTE Corporation. All rights reserved.   E300 Series Mini-type Integrated Universal Inverter.
Air Handler Terminology
DUAL POWER SUPPLY MODULE
Operation Sabbath Mode - SELECT PROGRAM - Lights, alarms and fans Normal Sabbath Overview.
Air Handler Terminology
Auxiliary Power Supply System By CGS Gunasekara. Content Why auxiliary supply is needed ? Equipments supplied through auxillary. Modes of operation. Demonstration.
Throw Pole Throw Pole nc no. Electric symbols Single pole single throw normally open Single pole single throw normally closed double pole single throw.
Engineer Training UV Electrical Cabinet (1-15) TJ8300 / TJ8500 UV Electrical Cabinet (Machines 1-15)
Hardware Training Product: ITMS2.
G1 Supplemental Questions
E1 – Electrical Fundamentals
Electro Eye-Hye System II
ADT490 Panel Theory. 2 System Power Supply Grounding ‣ Circuit separates positive / negative from Ground ‣ Ground fault - resistance to ground ≤ 10 kΩ.
Consumer’s Main Switchroom & Main L.V. Switchboard
PR570 POWERITE II TRAINING Dedicated to Success in Electronic Servicing for 50 Years.
1. 1.History Of Indian Railway 2.Types of Traction System 3.Non Electric traction system coaches 4.System Of Track Electrification 5.Power Supply For.
Concepts of Engineering and Technology Basic Electricity and Electronics: DC Circuits Copyright © Texas Education Agency, All rights reserved. 1.
the compact air control solution
By: Mr. Brock.  Electricity- Source of energy that can be easily converted into light, heat or power  Ampere (Amp)- Unit of measure of the rate of flow.
Main contacts closed – RED Colour with ON
E4 HVACR Electrical Installation
19.2 Domestic electricity Paying for electrical energy  Most of the electrical appliances in your home use mains electricity.  Mains electricity: alternating.
 E4 HVACR Electrical Installation #3 Circuit breakers, disconnects, and fuses.
Solar Power Charge Controller. Solar Power Charge Controller Introduction  A charge controller, or charge regulator is basically.
UH-60 IPC/MOI CW2 JAMES THOMAS.
CGS Ground School Technical The Vigilant Electrical System © Crown Copyright 2012 No Part of this presentation may be reproduced without the permission.
S A Griffiths CM42 June 2015 Electrical & Control.
2013 CHIGO Product CHIGO CMV VRF Control System.
Electrical Configuration and System Protection
VMCL ELECTRONIC DIVISION.
Inverter Assembly.
E4 HVACR Electrical Installation
E1 – Electrical Fundamentals
Sectos NXB and NXBD.
E4 HVACR Electrical Installation
Understanding Olympian Generator Set Schematics
FEEDER PROTECTION UNIT
TECHNICAL TRAINING 2007.
TABLE OF CONTENTS A- Unit description B- Microprocessor Control box
Practical electricity
ET 438B Sequential Control and Data Acquisition
AVIATION 325 ELECTRICAL SYSTEM.
HVAC Schematic Symbols
Objectives Review conductor and conduit selection
Objectives Finish with Practice circuits problems for
(or external generator)
Presentation transcript:

Description of various components/sub-assemblies

DESCRIPTION OF VARIOUS MODULES NAMEDESCRIPTION SUPPLY VOLTAGE A-1AC Compact Controller110 VDC A-2Disconnecting & Earthing Device 750 VAC, 110 VDC A-3Regulated Charger (RBC) 415 VAC/110 VDC A-5Pump Controller 110 VDC, 24 VDC A-6Insulation Control Relay AC 110V 220 VAC, 110 VAC A-7 Insulation Control Relay AC 240V/415V 220 VAC A-8 DC/ DC Converter (110V/24V) for Return/ Fresh Air Flap Servo Motors, Bar Gauges & Transducers 110 VDC/24 VDC

PROTECTION DEVICES NAMEDESCRIPTION SUPPLY VOLTAGE F-01 MCB (Triple Pole) 10A for Ventilation Fan Motor Unit 1 (Blower Motor-1) 415 VAC F-02 MCB (Triple Pole) 10A for Ventilation Fan Motor Unit 2 (Blower Motor-2) 415 VAC F-03 MCB (Triple Pole) 20A for Compressor Motor VAC F-04 MCB (Double Pole) 10A for Crankcase Heaters (for CP 1.1 & CP 1.2) 220 VAC F-05 MCB (Triple Pole) 20A for Compressor Motor VAC F-06 MCB (Triple Pole) 10A for Condenser Fan Motor VAC F-07 MCB (Triple Pole) 10A for Condenser Fan Motor VAC F-08MCB (Triple Pole) 6A for Heater Unit-1415 VAC

PROTECTION DEVICES NAMEDESCRIPTION SUPPLY VOLTAGE F-09 MCB (Triple Pole) 20A for Compressor Motor VAC F-10 MCB (Double Pole) 10A for Crankcase Heaters (for CP 2.1 & CP 2.2) 220 VAC F-11 MCB (Triple Pole) 20A for Compressor Motor VAC F-12 MCB (Triple Pole) 10A for Condenser Fan Motor VAC F-13 MCB (Triple Pole) 10A for Condenser Fan Motor VAC F-14 MCB (Triple Pole) 16A for Heater Unit-2 (PPS) 415 VAC F-15MCB (Triple Pole) 16A for Exhaust Fans415 VAC F-16MCB (Double Pole) 16A for Water Boiler220 VAC

PROTECTION DEVICES NAMEDESCRIPTION SUPPLY VOLTAGE F-17MCB (Double Pole) 10A for Soup Boiler220 VAC F-18MCB (Double Pole) 16A for Hot Case220 VAC F-19MCB (Double Pole) 6A for Bottle Cooler220 VAC F-20 MCB (Double Pole) 6A for Refrigerator (Deep Freezer) 220 VAC A-21 MPCB (Motor Protection Circuit Breaker) (1 to 1.6A) for Water Pump VAC A-22 MPCB (Motor Protection Circuit Breaker) (1 to 1.6A) for Water Pump-2 (Overload Relay for Water Pump-2) 415 VAC F-24MCB (Double Pole) 10A for Light Control110 VDC F-17MCB (Double Pole) 10A for Soup Boiler220 VAC

PROTECTION DEVICES NAMEDESCRIPTION SUPPLY VOLTAGE F-25 MCB (Double Pole) 10A for Emergency Lights 110 VDC F-26 MCB (Double Pole) 10A for Emergency Lights 110 VDC F-27 MCB (Double Pole) 16A for Reading Lights 110 VDC F-28 MCB (Double Pole) 16A for Reading Lights 110 VDC F-29 MCB (Double Pole) 16A for DC/DC Converter 110 VDC F-30 MCB (Double Pole) 6A for Minimal Voltage Relay 110 VDC F-31 MCB (Double Pole) 6A for Telephone (First Class only) 110 VDC F-32 MCB (Double Pole) 6A for Diagnosis (Indications & ACP lights) 110 VDC

PROTECTION DEVICES NAMEDESCRIPTION SUPPLY VOLTAGE F-33 MCB (Double Pole) 10A for Power Supply 110 VDC F-34MCB (Double Pole) 10A for Night Lights110 VDC F-35 MCB (Double Pole) 6A for AC Compact Controller 110 VDC F-36MCB (Double Pole) 6A for Pump Control 24 VDC, 110 VDC F-37 MCB (Double Pole) 10A for Sanitary Control 24 VDC F-38 MCB (Double Pole) 10A for Loud Speaker 24 VDC F-39MCB (Double Pole) 10A for Coach Light110 VAC F-40MCB (Double Pole) 10A for Coach Light110 VAC

PROTECTION DEVICES NAMEDESCRIPTION SUPPLY VOLTAGE F-41 MCB (Double Pole) 6A for Electric Razor Socket 110 VAC F-42 HRC Fuse (25A) for 110V (+ve) DC Supply to Panel 110 VAC F-43 HRC Fuse (25A) for 110V (-ve) DC Supply to Panel 110 VAC F-44 HRC Fuse (100A) in R-phase of Output of 60 KVA Transformer 415 VAC F-45 HRC Fuse (100A) in Y-phase of Output of 60 KVA Transformer 415 VAC F-46 HRC Fuse (100A) in B-phase of Output of 60 KVA Transformer 415 VAC F-47 HRC Fuse (80A) in Local Main Supply (R-phase) 415 VAC F-48 HRC Fuse (80A) in Local Main Supply (Y-phase) 415 VAC

PROTECTION DEVICES NAMEDESCRIPTIONSUPPLY VOLTAGE F-49 HRC Fuse (80A) in Local Main Supply (B-phase) 415 VAC F-50 HRC Fuse HT (63A) in R-phase for Network-1(Feeder-1) 750 VAC F-51 HRC Fuse HT (63A) in Y-phase for Network-1(Feeder-1) 750 VAC F-52 HRC Fuse HT (63A) in B-phase for Network-1(Feeder-1) 750 VAC F-53 HRC Fuse HT (63A) in R-phase for Network-2(Feeder-2) 750 VAC F-54 HRC Fuse HT (63A) in Y-phase for Network-2(Feeder-2) 750 VAC F-49 HRC Fuse (80A) in Local Main Supply (B-phase) 415 VAC F-50 HRC Fuse HT (63A) in R-phase for Network-1(Feeder-1) 750 VAC

PROTECTION DEVICES NAMEDESCRIPTION SUPPLY VOLTAGE F-49 HRC Fuse (80A) in Local Main Supply (B-phase) 415 VAC F-50 HRC Fuse HT (63A) in R-phase for Network-1(Feeder-1) 750 VAC F-51 HRC Fuse HT (63A) in Y-phase for Network-1(Feeder-1) 750 VAC F-52 HRC Fuse HT (63A) in B-phase for Network-1(Feeder-1) 750 VAC F-53 HRC Fuse HT (63A) in R-phase for Network-2(Feeder-2) 750 VAC F-54 HRC Fuse HT (63A) in Y-phase for Network-2(Feeder-2) 750 VAC F-55 HRC Fuse HT (63A) in B-phase for Network-2(Feeder-2) 750 VAC F-56 Glass Fuse (4A) UIC Remote Control (+ve) 24 VDC

PROTECTION DEVICES NameDescriptionSupply voltage F-57Glass Fuse (2A) UIC Remote Control (-ve)24 VDC F-58 Glass Fuse (2A) in Phase for AC 110V Insulation Control Relay (A-6) 110 VAC F-59 Glass Fuse (2A) in Neutral for AC 110V Insulation Control Relay (A-6) 110 VAC F-60 Glass Fuse (4A) in for AC 110V Insulation Control Relay (A-6) & AC 240V /415V Insulation Control Relay (A-7) 220 VAC F-61 Control Relay (A-6) & AC 240V/415V Insulation Control Relay (A-7) Glass Fuse (2A) in Neutral for AC 110V Insulation 220 VAC F-62 Control Relay (A-6) & AC 240V/415V Insulation Control Relay (A-7) 220 VAC F-63 Glass Fuse (6.3A) in +ve 110V DC for Anti Skid Device 110 VDC F-64Glass Fuse (6.3A) in +ve 110V DC for Brake110 VDC

PROTECTION DEVICES NAMEDESCRIPTION SUPPLY VOLTAGE F-65 Glass Fuse (6.3A) in -ve 110V DC for Anti Skid Device 110 VDC F-66 Glass Fuse (6.3A) in -ve 110V DC for Brake 110 VDC F-67Glass Fuse (1A) in Control Supply of K VAC F-68Glass Fuse (1A) in Control Supply of K VAC F-69 Glass Fuse (1A) in R-phase of K-45 (MMR for LMS) 415 VAC F-70 Glass Fuse (1A) in Y-phase of K-45 (MMR for LMS) 415 VAC F-71 Glass Fuse (1A) in B-phase of K-45 (MMR for LMS) 415 VAC F-72Glass Fuse (1A) in Control Supply of K VAC

PROTECTION DEVICES F-73Glass Fuse (1A) in Control Supply of K VAC F-74 Glass Fuse (10A) in Input Phase of Lighting X’mer 220 VAC F-75 Glass Fuse (10A) in Input Neutral of Lighting X’mer 220 VAC F-76 HRC Fuse (100A) in R-phase of Output of 60 KVA Transformer No. 2 (in Pantry car & German Power car) 415 VAC F-77 HRC Fuse (100A) in Y-phase of Output of 60 KVA Transformer No. 2 (in Pantry car & German Power car) 415 VAC F-78 HRC Fuse (100A) in B-phase of Output of 60 KVA Transformer No. 2 (in Pantry car & German Power car) 415 VAC F-79 HRC Fuse (63A) in R-phase for Radiator Motor, Roof Extractor-1 & VAC F-80 HRC Fuse (63A) in Y-phase for Radiator Motor, Roof Extractor-1 & VAC

PROTECTION DEVICES NAMEDESCRIPTION SUPPLY VOLTAGE F-81 HRC Fuse (63A) in B-phase for Radiator Motor, Roof Extractor-1 & VAC F-82 HRC Fuse (63A) in R-phase for Radiator Motor, Roof Extractor-3 & VAC F-83 HRC Fuse (63A) in Y-phase for Radiator Motor, Roof Extractor-3 & VAC F-84 HRC Fuse (63A) in B-phase for Radiator Motor, Roof Extractor-3 & VAC F-85 Motor Protection Circuit Breaker (MPCB) (0.1 to 2.5A) for Exhaust Fan-I 415 VAC F-86 Motor Protection Circuit Breaker (MPCB) (0.1 to 2.5A) for Exhaust Fan-II 415 VAC F-87 Motor Protection Circuit Breaker (MPCB) (0.25 to 4.0A) for Exhaust Fan-III 415 VAC F-90 HRC Fuse (1A) in R-phase of 750V Volt Meter Network-1 (Feeder-1) 750 VAC

PROTECTION DEVICES NAMEDESCRIPTION SUPPLY VOLTAGE F-91 HRC Fuse (1A) in Y-phase of 750V Volt Meter Network-1 (Feeder-1) 750 VAC F-93 HRC Fuse (1A) in B-phase of 750V Volt Meter Network-1 (Feeder-1) 750 VAC F-94 HRC Fuse (1A) in R-phase of 750V Volt Meter Network-2 (Feeder-2) 750 VAC F-95 HRC Fuse (1A) in Y-phase of 750V Volt Meter Network-2 (Feeder-2) 750 VAC F-96 HRC Fuse (1A) in B-phase of 750V Volt Meter Network-2 (Feeder-2) 750 VAC F-97 HRC Fuse (1A) in Control Supply of K-01 Net-1 Contactor (in Rev.-D only) 750 VAC F-98 HRC Fuse (1A) in Control Supply of K-01 Net-2 Contactor (in Rev.-D only) 750 VAC F-91 HRC Fuse (1A) in Y-phase of 750V Volt Meter Network-1 (Feeder-1) 750 VAC

PROTECTION DEVICES NAMEDESCRIPTION SUPPLY VOLTAGE F-100 Glass Fuse (2A) in Phase of Insulation Control Relay AC 415/240V for Transformer-1 (in Power Cars only) 220 VAC F-101 Glass Fuse (2A) in Phase of Insulation Control Relay AC 415/240V for Transformer-1 (in Power Cars only) 220 VAC F-102 Glass Fuse (2A) in Phase of Insulation Control Relay AC 415/240V for Transformer-2 (in Power Cars only) 220 VAC F-103 Glass Fuse (2A) in Phase of Insulation Control Relay AC 415/240V for Transformer-2 (in Power Cars only) 220 VAC

INDICATIONS NAMEDESCRIPTION SUPPLY VOLTAGE H-1Indication Operation Supply Network-1110 VDC H-2Indication Operation Supply Network-2110 VDC H-3Indication Operation Charger Float110 VDC H-4Indication Operation Local Main Supply-1110 VDC H-5Indication Operation Local Main Supply-2110 VDC H-6Indication Operation Charger Boost110 VDC H-7Indication Anti Skid Device Defect110 VDC H-8Indication Insulation Failure 110V110 VDC H-9Indication Insulation Failure 415V110 VDC H-10Indication Operation 415V OK110 VDC

CONTACTORS & RELAYS NAME DESCRIPTION SUPPLY VOLTAGE K-01Main Feeder Contactor Network-1 (Feeder-1)110 VDC, 750 VAC K-02Main Feeder Contactor Network-2 (Feeder-2)110 VDC, 750 VAC K-03 Measuring & Monitoring Relay (MMR) for Network- 1(Feeder-1) 750 VAC 24 VDC, 110 VDC, K-04 Measuring & Monitoring Relay (MMR) for Network- 2(Feeder-2) 750 VAC 24 VDC, 110 VDC, K-05Timer for Anti Skid Device110 VDC K-06Contactor for Electro Pneumatic Brake Application24 VDC, 110 VDC K-07Contactor for Electro Pneumatic Brake Release24 VDC, 110 VDC K-08 Contactor for Level 1 of Minimal Voltage Relay (MVR) (96V+120 Minutes for Emergency Light OFF) 110 VDC K-09 Contactor for Level 2 of Minimal Voltage Relay(MVR) (104V+30 Minutes for DC/DC Converters OFF) 110 VDC K-10 Contactor for Level 3 of Minimal Voltage Relay (MVR) (106V for Reading Light OFF) 110 VDC, 220 VAC

CONTACTORS & RELAYS NAME DESCRIPTION SUPPLY VOLTAGE K-11Contactor for Main Light Passenger Room110 VDC, 110 VAC K-12Contactor for Reading Light110 VDC K-13Contactor for Night Light110 VDC K-14 Contactor for Main Light Entrance Area & Sanitory Rooms 110 VDC, 110 VAC K-15Contactor for Emergency Light110 VDC K-16Contactor for Emergency Light110 VDC K-17Timer for Light ON/OFF ( Min)110 VDC K-18 Timer for External Power Supply/ Local Main Supply (L.M.S.) (for blinking of outdoor lamps) 110 VDC K-19Relay for UIC-Light-Remote Control ON24 VDC, 110 VDC K-20Relay for UIC-Light-Remote Control OFF24 VDC, 110 VDC

CONTACTORS & RELAYS NAME DESCRIPTION SUPPLY VOLTAGE K-21Contactor for Fresh Air Flap Motor24 VDC K-22Contactor for Return Air Flap Motor24 VDC K-23Contactor for 415V OK110 VDC, 220 VAC K-24Contactor for Water Pump No VDC/110 VDC, 415 VAC K-25Contactor for Water Pump No VDC/110 VDC, 415 VAC K-26 Contactor for Ventilation Fan Motor Unit-1(Blower- 1/NPPS) 110 VDC, 415 VAC K-27Contactor for Controller OK110 VDC K-28 Contactor for Ventilation Fan Motor Unit-2 (Blower- 2/PPS) 110 VDC, 415 VAC K-29Contactor for Exhaust Fan Motors110 VDC, 415 VAC K-31Contactor for Condenser Fan Motor VDC, 415 VAC

CONTACTORS & RELAYS NAME DESCRIPTION SUPPLY VOLTAGE K-32Contactor for Condenser Fan Motor VDC, 415 VAC K-33Contactor for Compressor Motor VDC, 415 VAC K-34Contactor for Compressor Motor VDC, 415 VAC K-35Contactor for Heater Unit 1 (NPPS)110 VDC, 415 VAC K-36Contactor for Condenser Fan Motor VDC, 415 VAC K-37Contactor for Condenser Fan Motor VDC, 415 VAC K-38Contactor for Compressor Motor VDC, 415 VAC K-39Contactor for Compressor Motor VDC, 415 VAC K-40Contactor for Heater Unit 2 (PPS)110 VDC, 415 VAC K-41Contactor for Local Main Supply-1 (LMS-1)220 VAC, 415 VAC

CONTACTORS & RELAYS NAME DESCRIPTION SUPPLY VOLTAGE K-42Contactor for Local Main Supply-2 (LMS-2)220 VAC, 415 VAC K-43Main Contactor for Local Main Supply (LMS)110 VDC, 415 VAC K-44 Contactor in the Output of 60 KVA Transformer (After 100A Fuses) 220 VAC, 415 VAC K-45 Measuring & Monitoring Relay (MMR) for Local Main Supply (LMS) 110 VDC, 415 VAC K-46 Contactor in the Output of 60 KVA Transformer-2 (in Original German Power cars & Pantry cars) 220 VAC, 415 VAC K-48 Interlocking Contactor for Changeover of Coach Light Supply from 110V AC to 110V DC & vice versa 110 VAC, 110 VDC K- RBC Contactor for Regulated Battery Charger (Main Charger) 415 VAC

METERS NAME DESCRIPTION SUPPLY VOLTAGE P-1Ampere Meter, AC (0-200 Amp) for Panel LoadmV P-2Volt Meter, AC (0-800V) for Network-1 (RY)750 VAC P-3Volt Meter, AC (0-800V) for Network-1 (YB)750 VAC P-4Volt Meter, AC (0-800V) for Network-1 (BR)750 VAC P-5Volt Meter, AC (0-800V) for Network-2 (RY)750 VAC P-6Volt Meter, AC (0-800V) for Network-2 (YB)750 VAC P-7Volt Meter, AC (0-800V) for Network-2 (BR)750 VAC P-8 Ampere Meter, DC (+ve ve) for Charge- Discharge Battery Net mV P-9 Ampere Meter, DC (0-40Amp) for Consumer Current Net mV P-10Volt Meter, DC (0-150V) for Battery Net110 VDC

SWITCHES NAME DESCRIPTION SUPPLY VOLTAGE S-01 Switch, Selector Power Supply ON/OFF (Rev.-D) 110 VAC, 110 VDC/ 415 VAC, 750 VAC S-02 Switch, Selector Net-1, Net-2 & LMS (Rev.-D) 110 VDC/ 415 VAC, 750 VAC S-03 Switch, Push Button for Insulation Test Battery Net +ve 110 VDC S-04 Switch, Push Button for Insulation Test Battery Net – ve 110 VDC S-05Switch, Push Button for Test Indication Lamps110 VDC S-06Switch, Push Button for Train Light ON24 VDC S-07Switch, Push Button for Train Light OFF24 VDC S-08Switch, Push Button for Lighting ON24 VDC S-09Switch, Push Button for Night Lighting ON110 VDC S-10Switch, Push Button for Lighting OFF110 VDC

CONVERTERS NAME DESCRIPTION SUPPLY VOLTAGE U-1Anti Skid Device110 VDC U-2.1 DC/DC Converter (110V/24V) for Water Pump Control & Sanitory Control 110 VDC, 24 VDC U-2.2 DC/DC Converter (110V/24V) for Loud Speaker System MMRs & UIC Remote Control 110 VDC, 24 VDC U-2.3Minimal Voltage Relay (MVR)110 VDC U-3Amplifier Loud Speaker system24 VDC U-4Air Conditioning Control Switch Panel24 VDC, 110 VDC

THREE PHASE POWER TERMINAL FOR AC PLANT Terminal no. Description Terminal no. Description 231 Ventilation CD fan Earth259 Compressor Ventilation Earth 238Earth263 Compressor Compressor Earth 242Earth267 Heater Compressor

THREE PHASE POWER TERMINAL FOR AC PLANT Fuse No.Rating (A)Description (Located in) 7510Neutral Input supply to Lighting transformer 7410Phase Input supply to Lighting transformer 731Control supply to K Control supply to K Blue Phase of MMR of local Main Supply 701Yellow Phase of MMR of local Main Supply 691Red Phase of MMR of local Main Supply 681Control supply to K Control supply to K ve 110 VDC supply for Brake ve 110 VDC supply for Anti Skid device ve 110 VDC supply for Brake ve 110 VDC supply for Anti Skid device 622 Neutral of AC 110 V Insulation Control relay (A-6) & AC 240/415 V Insulation Control relay (A-7)

THREE PHASE POWER TERMINAL FOR AC PLANT Fuse No.Rating (A)Description (Located in) Phase of AC 110 V Insulation Control relay (A-6) & AC 240/415 V Insulation Control relay (A-7) 592Neutral of AC 110 V Insulation Control relay (A-6) 582Phase of AC 110 V Insulation Control relay (A-6) 572-ve of 24 V UIC remote control 564+ve of 24 V UIC remote control

X 301X 501 1O C DIGITAL OUTPUT O 1Controller OKFaultO 11 O 15 O C6 2O 1O 115 3O 2 Recirculation Air Out Side Air O O 33 5O 4 O 3 Ventilation Fan 1 Ventilation Fan 2 O 13 O 142 6O 51 X 302 O 4 Not Active in System Exhaust Fan O 14 X 502 1O C DIGITAL OUTPUT O 19 O C6 2O 6 O 5 Bypass Cooling 1/1 Bypass Cooling 2/1 O 15 O 165 3O 74 4O 8 O 6 Condenser Fan 1/1 Condenser Fan 2/1 O 16 O 183 5O 92 6O 10 O 7 Condenser Fan 1/2 Condenser Fan 2/2 O 17 O 201 X 701X 702 LED layout on microprocessor controller

1RES NETWORK I 3 Temp. Cond. Motor 1.2 OK Temp. Cond. Motor 2.2 OK I CH + 3CL I 4 Vent Motor 1 Fault Vent Motor 2 Fault I VX 403 X 402 X 102 I 5 Temp. E.I. Heater 1 OK Temp. E.I. Heater 2 OK I RES NETWORK 9 2CH I 6 Low Pressure 1.1 OK Low Pressure 2.1 OK I CL 7 40V I 7 Low Pressure 1.2 OK Low Pressure 2.2 OK I 17 6 X RS 232 C I 8 Control Pressure 1 Control Pressure 2 I 18 4 X ANA LOG OUT I 9 High Pressure 1.1 Fault High Pressure 2.1 Fault I OUT High Pressure 1.2 Fault High Pressure 2.2 Fault I 20 X 104 GND2 1

1I 1 O 8 Compressor 1/1 Compresso r 2/1 O 18 I 11 2I 2I 12 3I 3 O 9 Compressor 1/2 Compresso r 2/2 O 19 I 13 4I 4 DIGITAL INPUT I C I 14 5I 5 O 10 E.I. Heater 1 E.I. Heater 2 O 20 I 15 6I C 7I 6 RUN : STAT 1I 16 8I 7STAT 2I 17 9I 8I 18 10I 9 I 1 Air - Co. 'ON' 400V OKI 11 I 19 11I 10I 20 12I C I 2 Temp. Cond. Motor 1.1 OK Temp. Cond. Motor 2.1 OK I 12 X 104 X 101 ANALOG INP 4….20 MA +

1RES NETWORK I 3 Temp. Cond. Motor 1.2 OK Temp. Cond. Motor 2.2 OK I CH + 3CL I 4 Vent Motor 1 Fault Vent Motor 2 Fault I VX 403 X 402 X 102 I 5 Temp. E.I. Heater 1 OK Temp. E.I. Heater 2 OK I RES NETWORK 9 2CH I 6 Low Pressure 1.1 OK Low Pressure 2.1 OK I CL 7 40V I 7 Low Pressure 1.2 OK Low Pressure 2.2 OK I 17 6 X RS 232 C I 8 Control Pressure 1 Control Pressure 2 I 18 4 X ANA LOG OUT I 9 High Pressure 1.1 Fault High Pressure 2.1 Fault I OUT High Pressure 1.2 Fault High Pressure 2.2 Fault I 20 X 104 GND2 1