EEV-KIT For Single refrigeration system. Preliminary information, all of contents are subject to final confirmation by MHI 2 Contents 1. Single refrigeration.

Slides:



Advertisements
Similar presentations
Operating Functions.
Advertisements

Daikin Altherma™ Troubling Shooting
SINGLE SPLIT INVERTER AIR-CONDITIONER
2008 AQV, EH, DH and FJM Inverter Troubleshooting
HEAT PUMPS.
Total HVAC Control from anywhere Easy control that can save a fortune
Setup/Installation/Operation of an Environmental Control Unit (ECU)
HVAC Commercial Ref.
38GXC(Q)/40GXC(Q) Service Training Sizes 18 and 24K.
= ( es ) 2 energy savings. 53% SAVINGS* THAN OTHER LEADING INVERTERS! Best Energy Savings! High 11+ EER CASSETTE INVERTER FLOOR STANDING INVERTER HIGH.
COMPUTERS AND INPUT SENSORS. cbc MICROCOMPUTER OPERATION HAPPENS IN STAGES Memory.
Air-Conditioning Control Systems
TECHNICAL TRAINING 2008.
Refrigerant Amount Adjust Mode TGMU, THMU, TJMU and TKMU TGMU, THMU, TJMU and TKMU.
Cooling Only 38MFC/ 40MFC Heat Pump 38MFQ/ 40MFQ
Product Introduction.
Troubleshooting Electric Control Devices
MDS Smart Commander.
Learning, our way Examples of bad installation. CONTENT Installation related examples Installation related examples Application related examples Application.
General Troubleshooting Tips.
Perfect solution for large building
Air conditioning – Refreshes your life Mini-Chiller Applied Systems Sales1 EWA(Y)Q-AAV3P Residential Mini-Chiller Heating EWAQ - AA3VP EWYQ - AAV3P Cooling.
Settings & Adjustments. Settings & Adjustments.
MDS COMMISSIONING.
TECHNICAL TRAINING INVERTER-Y
Air Handler Terminology
MDS Monitoring Software. Page 2 Contents  Introduction  User Interface  Service Personnel Interface  System Requirement  Demonstration.
EEV-KIT General Information. Preliminary information, all of contents are subject to final confirmation by MHI 2 Contents 1. What it EEV-KIT 2. What is.
Hydraulic Kit (pump and tank) Pictures from prototype.
1 Reading Electrical & Refrigerant Drawings. 2 General An electrical drawing shows the components of the circuit as simplified standard symbols, and the.
. Error Explanation . Cautions . Solution MAP . Communication wiring
For Multiple refrigeration system
DLP LCD PANEL Programming
Static vs. Velocity Pressure
G1 Supplemental Questions
System Appliances Division Training Manual MODERATO-P/J -. AQ09MSB -. AQ12MSB -. AQ18MSB -. AQ24MSB.
TECHNICAL TRAINING INVERTER-Y
CUE – Make Any Pump an E-Pump
MCQUAY DIGITAL SCROLL SYSTEM
Service Section Technical Training December 2005.
SB-DN-HVAC (MAC01.331) Air-Condition controller.
目录 12 in 1 Sensor Features ● PIR motion sensor ● Ultrasonic sensor ● LUX sensor ● Temperature sensor ● 2 Dry contacts ● 2 external condition inputs ● IR(infrared)
Esbe Rotary Motorized valves The ESBE Rotary Motorized valves (mixing valves and actuators) are used to control heating and cooling in buildings. We offer.
Problem Solving using Error Code Saijo Denki Inverter R-410A
© 2012 MITSUBISHI HEAVY INDUSTRIES – MAHAJAK AIR CONDITIONERS CO., LTD. All Rights Reserved. 5 August 2014.
Control Systems: Circuitry Electricity for Refrigeration, Heating and Air Conditioning 7th Edition Chapter 16 Control Systems: Circuitry and Troubleshooting.
Refrigerant system of Inverter R-410A. denki.co.th Model type Model : Stand Model : Duct Model : Cassette Model : Wall mount Model : Wall and.
UTH-65A VER. CAUTIONS ! PLEASE USE THE OUTLET PREPARED BY A QUALIFIED SERVICEMAN AND MUST CONFIRM IT BEFORE APPLY[SING AN ELECTRIC CURRENT.
ARÇELİK TİCARİ KLİMA EĞİTİM DÖKÜMANI APPENDIX.
James McIntyre VRF Training Manager V5 Key Components.
Refer to Service Manual for details Fault codes. To retrieve fault codes from the remote controller Press the ‘CHECK’ button for approximately.
2013 CHIGO Product CHIGO CMV VRF Control System.
shift to the Test Mode (Forced Operation).
CMV-NET Chigo VRF Network Centralized Control System
Fan Coil Controller FC/S 1.1
CHIGO VRF System Commissioning.
E1 – Electrical Fundamentals
FLoor Heating Controller
5. Outdoor unit Installation
Haiwell PLC Modules Introduce
FLoor Heating Controller
7. Test operation.
AHU connection kit.
Fault codes.
VITALITY Large Splits Johnson Controls PowerPoint Guidelines | July 21, 2009.
MDS Smart Commander.
Total HVAC Control from anywhere Easy control that can save a fortune
Error codes for split systems
Presentation transcript:

EEV-KIT For Single refrigeration system

Preliminary information, all of contents are subject to final confirmation by MHI 2 Contents 1. Single refrigeration system 2. System A (one heat exchanger) 3. System B (multiple heat exchangers) 4. Function of EEV CONTROL UNIT 4.1 SW1-4 (Address setting) 4.2 SW6 (Model capacity selection) 4.3 SW7 4.4 Switching return/supply air temp. control 4.5 Supply air temp. control in cooling 4.6 Supply air temp. control in heating 4.7 Automatic operation control

Preliminary information, all of contents are subject to final confirmation by MHI 3 1. Single refrigeration system Single refrigeration system is the system that EEVKIT6-E-C is built into one refrigeration system. There are 2 types of EEV-KIT system to be built into the single refrigeration system. One is “System A” and the other is “System B”. System A is; The system that only one set of EEV-KIT is built into one indoor unit with only one heat exchanger. This system can be applied to the indoor unit whose capacity is up to 10HP. System B is; The system that multiple EEV-KIT are built into one indoor unit with multiple heat exchangers. This system can be applied to the indoor unit whose capacity is up to 48HP.

Preliminary information, all of contents are subject to final confirmation by MHI 4 2. System A Configuration diagram Sensors Thi-A : Suction Air Temp. Sensor Thi-AF : Discharge Air Temp. Sensor Thi-R1,R2,R3 : Heat exchanger Temp. Sensor Thi-R1 Thi-R2 Thi-R3 Thi-AF Thi-A EEV-Control Unit FA N EEV-Set Strainer To other I/U RC There is a case that other I/U exists. 01 O/U Address O/U Address: 01 I/U Address: 01 Signal line EEV-Control BOX Sensors ( 5pcs ) Thi-A Thi-R1 Thi-R2 Thi-R3 Thi-AF EEV-KIT EEV-Control Unit EEV-Set Strainer EEV Strainer EEV-Control ASSY

Preliminary information, all of contents are subject to final confirmation by MHI 5 2. System A One EEV-KIT can control one EEV and its maximum capacity is 10HP (equivalent to P280). Capacity setting of EEV-Control Unit shall be done according to the required capacity. P280 is default setting. All wirings for 5 sensors, EEV-coil, operation command to indoor fan motor, remote controller and superlink signal line shall be connected to the EEV-Control Unit. Both of return/ supply air temp. sensors Be sure to check whether the temperature can be detected correctly. The heat exchanger temp. sensors Be sure to confirm whether the sensors detect the correct temperature. Wrong mounting of sensor may cause trouble of the compressor. Usage note #1

Preliminary information, all of contents are subject to final confirmation by MHI 6 2. System A Select a suitable MHI genuine EEV-Set according to the required capacity. The indoor fan motor, overcurrent relay for fan motor and magnet contactor for fan motor should be provided locally. Be sure to check in advance whether the anomaly detection can be made by inputting the overcurrent anomaly signal from the fan motor to the EEV- Control Unit. The power supply to indoor fan motor shall be provided independently, not from the EEV-Control Unit side. The remote controller (optional part for KX system: RC-E4) shall be provided separately, if necessary. Central control can be use for controlling together with the indoor units. The limitations of address setting, capacity selection and length of superlink line are same as KXE6. (See technical manual of KXE6 for details) Usage note #2

Preliminary information, all of contents are subject to final confirmation by MHI 7 In case of multiple refrigeration system, it can not control by this connecting method. In such case, be sure to use the EEV-KIT for multiple refrigeration system. 3. System B Thi-R1 Thi-R2 Thi-R3 Thi-AF Thi-A FA N EEV-Set 01(02) EEV-Control Unit O/U Address I/U Address RC Signal line Configuration diagram EEV-Control BOX Sensors ( 5pcs ) Thi-A Thi-R1 Thi-R2 Thi-R3 Thi-AF EEV-KIT EEV-Control Unit EEV-Set Strainer EEV Strainer EEV-Control ASSY

Preliminary information, all of contents are subject to final confirmation by MHI 8 3. System B Usage note #1 Unlike system A, system B is the system that multiple EEV-KIT are built into one AUH, and the outdoor unit KXE6 shall be applied. However in this system, multiple refrigeration system can not be applied to one indoor unit. In such case, be sure to use the EEV-KIT for multiple refrigeration system. Wiring connection method for each EEV-KIT is basically same as that for system A. All of return/supply air temp. sensors for all EEV-KIT shall be placed and connected individually. However the wiring for the command signal of indoor fan motor and remote controller should be connected to the one of EEV-Control Unit whichever you like, and the wiring of remote controller shall be connected to all EEV- Control Unit.

Preliminary information, all of contents are subject to final confirmation by MHI 9 3. System B Usage note #2 Superlink line shall be connected among all EEV-Control Units and the outdoor unit according to the rule of KXE6 system. Set an address to each EEV-Control Unit. When controlling this indoor unit together with the indoor units in another refrigerant systems by central control, be sure to connect the superlink line to the central control through superlink adaptor in order to prevent the multiple addresses from existing in one indoor unit.

Preliminary information, all of contents are subject to final confirmation by MHI Function of EEV-Control Unit SW7: For function setting (See item 4.3) SW1-SW4 and SW6 can be set according to the required specifications SW1-SW4 : For address setting (See item 4.1) ( Same method as the KXE6 indoor unit) SW6: For capacity selection (See item 4.2) SW5: For address setting, etc. (See item 4.1)

Preliminary information, all of contents are subject to final confirmation by MHI Function of EEV-Control Unit 4.1 SW1-SW4 (Address setting) 4.2 SW6 (Model capacity selection) Set address in the same manner as KX system Set the model capacity according to the heat exchanger capacity. * OFF: 100’s=0 ON : 100’s=1 SW5-1 should be kept OFF.

Preliminary information, all of contents are subject to final confirmation by MHI Function of EEV-Control Unit 4.3 SW7 (Function setting) Note: 1. ★ shows factory default. 2. SW7-2 and SW7-4 should be kept OFF.

Preliminary information, all of contents are subject to final confirmation by MHI Function of EEV-Control Unit 4.4 Switching return/supply air temp. control Be sure to apply the attached return air temp. sensors and supply air temp. sensors at suitable position to detect the temperature correctly and to make the detected temperature difference between sensors minimized. When SW7-3 is OFF, it will become return air temp. control and EEV is controlled to keep the super heat constant. When SW7-3 is ON, it will become supply air temp. control and EEV is controlled to keep the supply air temperature constant.

Preliminary information, all of contents are subject to final confirmation by MHI Function of EEV-Control Unit Supply air temperature control in cooling ・ The set temperature of supply air for supply air temperature control is fixed by the set value of target low pressure. ・ Factory default is shown in following table. ・ The set temperature can be changed ±3degC at maximum by using No. 01and 08 of I/U function set by remote controller. (Set temp. range: Air conditioning mode :12-18 ℃, OA processing mode: ℃) *1 For changing to OA processing mode, set the No.17 ( PRESSURE CONTROL) of indoor unit function set by remote controller. ★ factory default

Preliminary information, all of contents are subject to final confirmation by MHI Function of EEV-Control Unit Supply air temp. control in heating ・ The set temperature of supply air for supply air temp. control is fixed. ・ The set temp. and target high pressure in air conditioning mode is different from those in OA processing mode. ・ Factory default is shown in following table. ・ The set temperature can be changed ±4degC at maximum by using No. 09 of I/U function set by remote controller. (Set temp. range: Air conditioning mode:36-44 ℃, OA processing mode: ℃) ★ factory default *1 For changing to OA processing mode, set the No.17 ( PRESSURE CONTROL) of indoor unit function set by remote controller.

Preliminary information, all of contents are subject to final confirmation by MHI Function of EEV-Control unit Automatic operation control ・ Operation mode (Cooling, Fan, Heating) can be changed automatically by detecting the difference between set temperature and return air temperature. ・ The temperature to change operation mode can be set by using remote controller function setting No.11 as follows. Increase temp. Decrease temp. Heating mode Cooling mode ▲ Set point Ts) -2-2 +1+1 -1-1 +2+2 Fan mode Heating mode Cooling mode ▲ Set point (Ts) - 1.5 + 0.5 - 0.5 + 1.5 Fan mode Heating mode Cooling mode ▲ Set point (Ts) -1-1 + 0.5 - 0.5 +1+1 Fan mode Automatic operation B Automatic operation A Automatic operation C ★ factory default