Introduction Montelupo Fiorentino is a little town about 20 km west of Florence, characterised by the presence of a large number of ceramic and glass factories.

Slides:



Advertisements
Similar presentations
The 26g Al(p, ) 27 Si Reaction at DRAGON Heather Crawford Simon Fraser University TRIUMF Student Symposium July 27, 2005.
Advertisements

PM Chemical Composition Jiří Smolík, Jaroslav Schwarz Institute of Chemical Process Fundamentals AS CR, Praha.
Esther Coz 1,2, Gary Casuccio 3, Traci L. Lersch 3, Teresa Moreno 2 and Begoña Artíñano 1 5th DAURE Science Meeting Barcelona, May 26 DAURE Microscopy.
Ion beam Analysis Joele Mira from UWC and iThemba LABS Tinyiko Maluleke from US Supervisor: Dr. Alexander Kobzev Dr. Alexander Kobzev.
 Single Replacement Reactions + + . General Equation A + BX  AX + B.
P. D. Hien, V. T. Bac, N. T. H. Thinh Vietnam Atomic Energy Commission.
Trace Elemental Composition and Concentration of Upstate New York Rainwater Samples Using the Union College Pelletron Particle Accelerator and Proton Induced.
- Differential experiments: - Charged particle emission DDX - Gamma-ray production cross section - (n,2n) reaction cross section with a beam source - Integral.
ED and WD X-ray Analysis
Forschungszentrum Karlsruhe in der Helmholtz-Gemeinschaft Neutron capture cross sections on light nuclei M. Heil, F. Käppeler, E. Uberseder Torino workshop,
Cross section measurements for analysis of D and T in thicker films Liqun Shi Institute of Modern Physics, Fudan University, Shanghai, , People’s.
Ion Beam Analysis of Gold Flecks in a Foam Lattice F E Gauntlett, A S Clough Physics Department, University of Surrey, Guildford, GU2 7XH, UK.
X-Ray Fluorescence Analysis by Gergana Hristozova Project supervisor: s. eng. M. Gustova FLNR.
The 1 st Research Coordination Meeting Reference Database for PIGE Van de Graaff Lab in Tehran activities.
Arifa Lodhi and Badar Ghauri Pakistan Space And Upper Atmosphere Research Commission (SUPPARCO), P. O. Box 8402, University Road, Karachi-75270, Pakistan.
Electron-impact inner shell ionization cross section measurements for heavy element impurities in fusion reactors Jingjun Zhu Institute of Nuclear Science.
Construction of a Scattering Chamber for Ion-Beam Analysis of Environmental Materials in Undergraduate Physics Research Scott LaBrake, Michael Vineyard,
The Schrödinger Model and the Periodic Table. Elementnℓms H He Li Be B C N O F Ne.
1 JOINT RESEARCH CENTRE EUROPEAN COMMISSION IAEAPNRI Particle air pollution monitoring with nuclear analytical techniques: challenges and opportunities.
Nuclear Analytical Techniques applied to Element Analysis of the Danube Delta Lacustrine Sediments and Soil L.C. Dinescu Horia Hulubei National Institute.
Air Quality Surveillance Branch Air Monitoring Operations l Manual and Non-criteria Samplers » Reggie Smith » Special Purpose Monitoring & Data Support.
Ion Beam Analysis Dolly Langa Physics Department, University of Pretoria, South Africa Blane Lomberg Physics Department, University of the Western Cape,
Please do not write on this document. Thank you. Atomic Radius Data Element Name Atomic Number Atomic Radius (pm) Height of Straws (cm) H He
FRANK LABORATORY OF NEUTRON PHYSICS ION BEAM ANALYSIS STANCIU-OPREAN LIGIA SUPERVISOR DR. KOBZEV ALEXANDER.
FRANK LABORTORY OF NEUTRON PHYSICS ION BEAM ANALYSIS
Detection of trace elements in meteorites using PIXE Presented by: Sasha dos-Santos.
Reactions Reference. Solubility Rules 1.All nitrates, acetates, and chlorates are soluble. 2.All chlorides, bromides, and iodides are soluble except for.
MATTER 1.1ATOMS AND MOLECULES MATTER CONTENTS Define relative atomic mass and relative molecular mass based on the C-12 scale Analyze mass spectra in.
Modern Periodic Table Objective:
UL UNIVERSIDADE DE LISBOA CENTRO DE FÍSICA NUCLEAR People: Senior Researchers (responsible for activity lines): Eduardo Alves (Head of Lab) Adelaide Pedro.
Temporal variations of aerosol components in Tijuana, Mexico, during the Cal-Mex campaign S. Takahama, A. Johnson, J. Guzman Morales, L.M. Russell Scripps.
X-Ray Microanalysis – Precision and Sensitivity Recall… wt.fraction I = I SiKα (unknown) / I SiKα (pure std.) K-ratio I = [I SiKα (unknown ) / I SiKα (std.)
Atomic Theory: The Nuclear Model of the Atom Chapter 5 Presentation Slides to Accompany Cracolice/Peters Introductory Chemistry: An Active Learning Approach,
Variations of Elemental Concentration in PM 10 and PM June 2007,Colombo. M.C. Shirani Seneviratne Head, Nulear Analytical Services Sec. Atomic.
Interagency Monitoring of Protected Visual Environments (IMPROVE) Data Precision Nicole P. Hyslop and Warren H. White.
Basics of Ion Beam Analysis
External micro-PIXE analysis of the metal deposition on a CMS pitch adapter M. Massi, L. Giuntini, M.E. Fedi, C. Arilli, N. Grassi, P.A. Mandò, A. Migliori,
F. Lucarelli 1, S. Becagli 2, G. Calzolai 1, M. Chiari 1, T. Martellini 2, S. Nava 1, L. Paperetti 1, R. Udisti 2 and E. Yubero 3 1. INFN and Dept. of.
Results of the NEMO-3 experiment (Summer 2009) Outline   The  decay  The NEMO-3 experiment  Measurement of the backgrounds   and  results.
Teacher Notes This PPT was revised June 10, This PPT is a review on the atomic characteristics of the four main essential elements hydrogen, carbon,
2.2 The Mass Spectrometer. Assessment Objectives Describe and explain the operation of a mass spectrometer Describe how the mass spectrometer.
Nuclear-related techniques at LABEC for the analysis of atmospheric aerosols S.Nava, G. Calzolai, M. Chiari, F.Lucarelli, M. Giannoni, M. Fedi, L. Giuntini,
Accelerator Based Techniques for Air Pollution Studies Across Asia David Cohen, ANSTO, Sydney, Australia
Forschungszentrum Karlsruhe in der Helmholtz-Gemeinschaft Neutron capture measurements for the weak s-process Michael Heil Hirschegg workshop, January.
Neutron production and iodide transmutation studies using intensive beam of Dubna Phasotron Mitja Majerle Nuclear Physics Institute of CAS Řež, Czech republic.
Transmutation of 129 I with high energy neutrons produced in spallation reactions induced by protons in massive target V.HENZL Nuclear Physics Institute.
Measurement of the CR light component primary spectrum B. Panico on behalf of ARGO-YBJ collaboration University Rome Tor Vergata INFN, Rome Tor Vergata.
Monte Carlo methods in spallation experiments Defense of the phD thesis Mitja Majerle “Phasotron” and “Energy Plus Transmutation” setups (schematic drawings)
Investigation of the proton-induced reactions on natural molybdenum.
22nd International Conference on Ion Beam Analysis, June , 2015- Opatija, Croatia Characterization and source apportionment of fine particulate.
Willy Maenhaut1, Wan Wang1, Xuguang Chi1, Nico Raes1, Jan Cafmeyer1,
PIXE measurements of heavy metals of Tsunami sediment samples
Predicting Reactions.
Periodensystem Biomaterials Research - Manfred Maitz H He Li Be B C N
Emission of Energy by Atoms and Electron Configurations
آزمایشگاه فارماکولوژی و سم شناسی
Happy Friday! Please take out note packet and calculator.
Periodic Table of the Elements
Chemsheets AS006 (Electron arrangement)
The Atom.
Speed Dating Speed Dating H Na Speed Dating Speed Dating K Be.
ION BEAM ANALYSIS.
Electron Configurations
DETECTION LIMITS < 1 ppt ng/L 1-10 ppt ng/L ppt ng/L
C.N.R. Institute of Atmospheric Pollution
The Periodic Table Part I – Categories of Elements
Ionic vs. Covalent Bonding
Evaluation of portable X-ray fluorescence (pXRF) in exploration and mining: Phase 1, control reference materials by Gwendy E.M. Hall, Graeme F. Bonham-Carter,
C.N.R. Institute of Atmospheric Pollution
Electron Configurations and the Periodic Table
Presentation transcript:

Introduction Montelupo Fiorentino is a little town about 20 km west of Florence, characterised by the presence of a large number of ceramic and glass factories. Since the PM 10 mean value in the area is higher than the new Air Quality Directive (1999/39/EC) recommended value and potentially harmful elements can be emitted by the local industrial activities, we decided to start a deep investigation to determine the mass concentrations and the elemental composition of the PM 10, PM 2.5 and PM 1 fractions of the aerosol. Sampling PM 10, PM 2.5 and PM 1 samples were collected, on a daily basis, on 47 mm diameter Teflon filters, by three single-mode sequential samplers (one PARTISOL 2025 and two IND PNS15D), located 4 m above ground level, on the roof of an air quality monitoring station. Mass concentrations were obtained using an analytical balance. The sampling campaign lasted from the 24 th of September 2002 to the 2 nd of July 2003: during certain periods we mounted the same inlet on all the instruments to carry on a systematic comparison between the three devices (about ten days for each fraction); during 3 weeks we put a different inlet on each instrument to measure the granulometric fraction ratios (i.e. PM 2.5 /PM 10 and PM 1 /PM 10 ). Starting from the 21 st of December we continued the sampling with only one IND sampler with PM 10 inlet. Particulate matter composition in an industrial district near to Florence Massimo Chiari a, Piero Del Carmine a, Franco Lucarelli a, Graziella Marcazzan b, Silvia Nava c, Leonardo Paperetti a, Paolo Prati c, Gianluigi Valli b, Roberta Vecchi b, Alessandro Zucchiatti c a Physic Dept. and INFN - Firenze, b Istituto di Fisica Generale Applicata - Milano, c Physic Dept. and INFN - Genova 10 cm surface-barrier detectors:  = 150°  C, N, O;  = 30°  H proton beam: 3 MeV, 5 nA (3  C per sample ) aerosol sample Faraday cup HPGe detector Percentage contributions of the eight most abundant elements detected by PIXE and PESA to the total gravimetric mass. ‘Other PIXE’ is the sum of the other elements detected by PIXE. The values are averaged over the 3 weeks of simultaneous sampling of the three fractions. Ion Beam Analysis at the Van de Graaff accelerator in Florence The concentrations of the elements with Z > 10 were measured by Particle Induced X-ray Emission (PIXE) at the external beam facility. PIXE measurements were performed at 2.2 MeV proton energy to reduce the Compton  -ray background produced by the fluorine in the Teflon filters. The X-ray spectra have been fitted for 28 elements (Na, Mg, Al, Si, P, S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Br, Sr, Zr, Pb, Mo, Cd, Sb, Sn) using the GUPIX software package. To obtain a complete reconstruction of the aerosol mass, we implemented the detection of H, C, N and O by in-vacuum Particle Elastic Scattering Analysis (PESA). Assuming a constant C/F ratio in Teflon, the contribution due to the carbon content of the filter to be subtracted to the total C signal is proportional to the ‘local’ filter thickness and to its F content, which can be measured by Particle Induced  -ray Emission (PIGE) analysis (simultaneously with PESA) exploiting the 19 F(p,p’  ) 19 F reaction (E  = 110 keV). Q uantitative results were obtained by direct comparison with thin standards (supplied by Micromatter Inc.) for PIXE and with a thin Upilex-S foil (H 10 C 22 N 2 O 4 ) for PESA. Typical MDLs were 0.1  g/m 3 for H, 1  g/m 3 for C, 0.5  g/m 3 for both N and O, and 1-10 ng/m 3 for all the other elements. The absolute concentration of all the elements could be measured with an error ranging from ±5% to ±30% with the bigger errors affecting concentration values approaching MDLs. 10 cm proton beam: 2.2 MeV, 10 nA (3  C per sample) Si(Li) detectors Faraday cup aerosol sample PIXE SET-UPPESA SET-UP Results The comparison between the three samplers showed generally a very good agreement both for mass and for elemental concentrations. As regards the results from the analysis of the samples collected simultaneously in the three fractions, PM 2.5 and PM 1 turned out to be a substantial part of PM 10 ; excluding four days in which there was an anomalous increase in PM 10 concentrations respect to PM 2.5 and PM 1 (Saharan dust episode), the PM 2.5 /PM 10 and PM 1 /PM 10 ratios are (0.63 ± 0.09) and (0.46 ± 0.08) respectively. Al, Si, Ca, Fe, Sr and other typical crustal elements, and also Zr (produced by the manufacturing of tiles), are more concentrated in the PM 2.5–10 fraction, while elements like H, C, N, O, S, K, Zn, As (mean concentration 50 ng/m 3, with peaks up to 100 ng/m 3, related to emissions from artistic glass manufactures), and Pb are mainly present in the PM 2.5 and PM 1 fractions. C, N and O are the main aerosol components, with carbon giving the most important contribution to the total mass in all the fractions (about 40% in PM 10 and 50% in PM 2.5 and PM 1 ). Saharan dust episode Increase of the concentration of all soil-related elements (Al, Si, Fe, Ti) in the PM 10 fraction. Confirmed by back-trajectories calculations. Montelupo Fiorentino Sahara desert Back-trajectories by HYSPLIT (NOAA ARL) Picture from NASA PM 10, PM 2.5 and PM 1 mass concentrations during the simultaneous sampling of the three fractions. Percentage decomposition of the elemental concentrations in the three granulometric fractions. The values are averaged over the 3 weeks of simultaneous sampling of the three fractions.