Storage Procurements Some random thoughts on getting the storage you need Martin Bly Tier1 Fabric Manager.

Slides:



Advertisements
Similar presentations
Tuning the Dennis Shasha and Philippe Bonnet, 2013.
Advertisements

Data Storage Solutions Module 1.2. Data Storage Solutions Upon completion of this module, you will be able to: List the common storage media and solutions.
1 Lecture 18: RAID n I/O bottleneck n JBOD and SLED n striping and mirroring n classic RAID levels: 1 – 5 n additional RAID levels: 6, 0+1, 10 n RAID usage.
IT 344: Operating Systems Winter 2007 Module 18 Redundant Arrays of Inexpensive Disks (RAID) Chia-Chi Teng CTB 265.
Denny Cherry twitter.com/mrdenny.
RAID Oh yes Whats RAID? Redundant Array (of) Independent Disks. A scheme involving multiple disks which replicates data across multiple drives. Methods.
ISCSI guides and suggestions. For most implementations.
Whats Inside a PC?. UNT in partnership with TEA, Copyright © All rights reserved.2 II. Major Components: Motherboard 1. Referred to as heart of.
Removing the I/O Bottleneck with Virident PCIe Solid State Storage Solutions Jan Silverman VP Operations.
Preparing For Server Installation Instructor: Enoch E. Damson.
SAN Last Update Copyright Kenneth M. Chipps Ph.D. 1.
Virtualization on the Intel Platform Scott Elliott Senior Systems Network Specialist Christie Digital A Customer Implementation with VMware and IBM.
1 Recap (RAID and Storage Architectures). 2 RAID To increase the availability and the performance (bandwidth) of a storage system, instead of a single.
“GRID” Bricks. Components (NARA I brick) AIC RMC4E2-QI-XPSS 4U w/SATA Raid Controllers: 3ware- mirrored root disks (2) Areca- data disks, battery backed.
Chapter 3 Chapter 3: Server Hardware. Chapter 3 Learning Objectives n Describe the base system requirements for Windows NT 4.0 Server n Explain how to.
Storage Networking Technologies and Virtualization Section 2 DAS and Introduction to SCSI1.
Native InfiniBand Storage Deployment & Customer Experiences Dave Ellis Director, HPC Architecture LSI Logic IBTA & OFA DevCon San Francisco September 25,
Emerging Storage Options for Server Blade Architectures Server Blade Summit 2005.
Computer Memory.
Virtual Network Servers. What is a Server? 1. A software application that provides a specific one or more services to other computers  Example: Apache.
Solutions today for tomorrows problems iSCSI Storage Revealed By Ray Quattromini Fortuna Power Systems Ltd February 2004.
1 Web Server Administration Chapter 3 Installing the Server.
Tier1 Site Report HEPSysMan, RAL June 2010 Martin Bly, STFC-RAL.
DISKS IS421. DISK  A disk consists of Read/write head, and arm  A platter is divided into Tracks and sector  The R/W heads can R/W at the same time.
Tier1 - Disk Failure stats and Networking Martin Bly Tier1 Fabric Manager.
Chapter 2 Chapter 2: Planning for Server Hardware.
Baydel Founded in 1972 Headquarters: Surrey, England North American Headquarters: San Jose, CA Engineering Driven Organization Specialize in Computer Storage.
© 2009 IBM Corporation IBM Systems & Technology Group System x and BladeCenter® Why BladeCenter S SAN is the Right Choice Lowest cost, lowest complexity,
To teach specification preparation  the importance of well-prepared specifications in procurement  the different types of specifications  basic writing.
Microprocessors Chapter 3.
Nexenta Proprietary Global Leader in Software Defined Storage Nexenta Technical Sales Professional (NTSP) COURSE CONTENT.
RAL Tier1 Report Martin Bly HEPSysMan, RAL, June
Redundant Array of Inexpensive Disks aka Redundant Array of Independent Disks (RAID) Modified from CCT slides.
Nexenta Proprietary Global Leader in Software Defined Storage Nexenta Technical Sales Professional (NTSP) COURSE CONTENT.
Buffalo Data Storage Expansion June As organizations grow the amount of data storage capacity required to support it grows as well Increased data.
CPU (CENTRAL PROCESSING UNIT): processor chip (computer’s brain) found on the motherboard.
Discovery Internetworking Module 1 JEOPARDY K. Martin.
Chapter 5 Section 2 : Storage Networking Technologies and Virtualization.
Planning and Designing Server Virtualisation.
Storage Systems Market Analysis Dec 04. Storage Market & Technologies.
Hardware Trends. Contents Memory Hard Disks Processors Network Accessories Future.
RAL Tier 1 Site Report HEPSysMan – RAL – May 2006 Martin Bly.
Tier1 Status Report Martin Bly RAL 27,28 April 2005.
RAL Site Report Martin Bly HEPiX Fall 2009, LBL, Berkeley CA.
Martin Bly RAL Tier1/A RAL Tier1/A Report HepSysMan - July 2004 Martin Bly / Andrew Sansum.
Hardware. Make sure you have paper and pen to hand as you will need to take notes and write down answers and thoughts that you can refer to later on.
Tier1 Hardware Review Martin Bly HEPSysMan - RAL, June 2013.
Davie 5/18/2010.  Thursday, May 20 5:30pm  Ursa Minor  Co-sponsored with CSS  Guest Speakers  Dr. Craig Rich – TBA  James Schneider – Cal Poly.
ISCSI. iSCSI Terms An iSCSI initiator is something that requests disk blocks, aka a client An iSCSI target is something that provides disk blocks, aka.
ClinicalSoftwareSolutions Patient focused.Business minded. Slide 1 Opus Server Architecture Fritz Feltner Sept 7, 2007 Director, IT and Systems Integration.
Component 8/Unit 9aHealth IT Workforce Curriculum Version 1.0 Fall Installation and Maintenance of Health IT Systems Unit 9a Creating Fault Tolerant.
Tested, seen, heard… Andrei Maslennikov Rome, April 2006.
The RAL Tier-1 and the 3D Deployment Andrew Sansum 3D Meeting 22 March 2006.
Storage System Optimization. Introduction Storage Types-DAS/NAS/SAN The purposes of different RAID types. How to calculate the storage size for video.
This courseware is copyrighted © 2016 gtslearning. No part of this courseware or any training material supplied by gtslearning International Limited to.
Virtual Environments and Level III Redundancy A modern, green and fault tolerant approach to radio automation system design Patrick J. Campion Director.
CERN Disk Storage Technology Choices LCG-France Meeting April 8 th 2005 CERN.ch.
E2800 Marco Deveronico All Flash or Hybrid system
Video Security Design Workshop:
Introduction to Computer Studies
CERN Lustre Evaluation and Storage Outlook
GridPP Tier1 Review Fabric
COMPUTER ORGANISATION AND ARCHITECTURE
Upgrading to Microsoft SQL Server 2014
COMPTIA SK0-004 CompTIA Server+. VceTests provide unique study material for the preparation of SK0-004 with 100% passing guarantee. Get latest SK0-004.
CSE 451: Operating Systems Spring 2006 Module 18 Redundant Arrays of Inexpensive Disks (RAID) John Zahorjan Allen Center.
Chapter Overview Computer Disassembly and Reassembly
Mark Zbikowski and Gary Kimura
CSE 451: Operating Systems Winter 2007 Module 18 Redundant Arrays of Inexpensive Disks (RAID) Ed Lazowska Allen Center 570.
IT 344: Operating Systems Winter 2007 Module 18 Redundant Arrays of Inexpensive Disks (RAID) Chia-Chi Teng CTB
Presentation transcript:

Storage Procurements Some random thoughts on getting the storage you need Martin Bly Tier1 Fabric Manager

20 June 2008 Stoarge Procurements - RAL You want How Much? Know your units –TB (10^12) is not the same as TiB (2^40) –Storage vendors talk in terms of TB and raw capacity –Define what you mean by 1TB and what you mean by your capacity requirements For the Tier1 procurements: –Capacity in units of 1TB=10^12 bytes –Usable capacity described in terms of RAID5 or RAID6 redundancy (or even RAID 1+0) –Thus N data drives will give (N-2)*Size_of_drives usable storage (R5,6)

20 June 2008 Stoarge Procurements - RAL Storage type Lots of sorts –SAN, NAS, DAS, iSCSI… Different technologies –FC, SCSI, SAS, SATA Arrangement –RAID levels, array/server arrangements Each appropriate for different use cases –Speed, cache/buffer sizes (disk, controller), battery backup units

20 June 2008 Stoarge Procurements - RAL Technical specs Specify what *you* want –In as much detail as is necessary to get it –Be as unambiguous as possible Three types of specification: –Mandatory – non-compliant if not provided –Desirable – youd like it but omission is not a non-compliance –Optional – gives the vendor some scope for added value Specify *everything* –Including CPU performance, RAM, NICs, which OS, acceptance tests, documentation requirements, maintenance and warranty etc Provide required (achievable!) performance metrics –And a recipe to do the tests… Define bid evaluation criteria before issuing the spec or call for tender

20 June 2008 Stoarge Procurements - RAL Technology issues Motherboard SATA controllers, NICs Issues with concurrent i/o performance of 3ware cards Are the drivers required for the components you need available in the version of the OS you intend to run –If not – are you prepared to build extra modules for them, and do it every time a new kernel comes along until it *is* available in the stock builds: c.f. areca driver in SL 4.6, kernel >= And you may have to add them to the installation kernel…

20 June 2008 Stoarge Procurements - RAL Technology Issues II In RAID systems, number of drives per controller: –Fewer drives, fewer concurrent drives used for read or write, lower performance –More drives, better performance, but performance drops off across the Span –Large RAID sets on single controllers are not recommended, though more than one RAID per controller seems OK

20 June 2008 Stoarge Procurements - RAL Technology Issues III Capacity per box –I/O bandwidth to disks –I/O bandwidth to network Memory – is more better CPU architecture OS issues Resilience Reliability

20 June 2008 Stoarge Procurements - RAL Large Procurements Where value large => EU tender rules Avoid specifications that mention Tradenames, OEM names, non- benchmarked performance indicators, proprietary technologies… –Unless referring to a common name for a part to a recognised industry standard commando plugs are IEC.309 / BS EN –But quote the standard first Use ISO, EN or BS standards –ISO and EN take precedence over BS where there is an equivalent EN. Some EN standards adopted as the BS. Be prepared for a long process –Restricted: longer, two stages, get to restrict the final bidders –Open: shorted, many more bidders to evaluate Can use Catalyst (GCAT) or other schemes For small volumes, exercise your supplier contacts

20 June 2008 Stoarge Procurements - RAL Random thoughts Weight, cooling, power consumption, power feeds, power redundancy, NIC redundancy, switch uplink capacity, warranty, availability of spares after maintenance period, Castor/dCache/DPM/xrootd, disks/controller, controllers/chassis, RAM per chip/core, chips/cores per chassis, redundant system drives, lights-out operation, component quality, interoperability with existing systems, chunk size