Introduction to 85108A Pulsed Network Analyzers Pengcheng Jia Dec 13, 2001.

Slides:



Advertisements
Similar presentations
SATHUNTER Satellite pointing made easy DVB-S2 DVB-S.
Advertisements

Hardware Integration of the Prototype Wes Grammer NRAO September 24-26, 2012EOVSA Prototype Review1.
Measuring High-Frequency Networks and Components using Vector Network Analyzers Giovanni D’Amore Welcome to “Measuring High-Frequency Networks and Components.
Operating the Harmonizer
Lab7: Introduction to Arduino
Unit Test Calibration Training
Crown DSi Series Control Click the Crown Logo at the top of any the screen to return to this Menu Interactive Main Menu Interactive Front Panel Display.
Quickfilter Pro Software Demonstration for QF1D512 The following slides will illustrate how you can design and verify a filter design in minutes! BEGIN.
1 SCHOOL OF COMPUTER & COMMUNICATIONS ENGINEERING EKT 341/4 ANTENNAS AND PROPAGATION Lecturer: En. Rosmizi bin Abd Rahim Dr. Mohd Faizal Bin Jamlos PLV:
Coaxial Measurements – Common Mistakes & Simple Solutions Sathya Padmanabhan Rocky Teresa Maury Microwave Corp. For electronic copy of presentation go.
Multi Port Measurements
June 2004, CERN AB RF / FB, João Bento, Fritz Caspers 1 The IEEE1394 Test Board Results Measurements with a Vector Network Analyzer (VNA) type HP 8753D.
1 EuMW Seminars 2013 What Have You Been Missing In Your Pulsed VNA Measurements? 8 Oct :00h - 13:40h Presented by: Bob Buxton.
DC Choppers 1 Prof. T.K. Anantha Kumar, E&E Dept., MSRIT
Smith Chart.
Spectrum Analyzer. Another Oscilloscope??? Like an oscilloscope Oscilloscope in time domain Spectrum analyzer in frequency domain (selectable)
PRIME Antenna Inc. Antenna Test Team Adam Straubinger Alan Condino Thanh Hong Ronnie Berg Sam Gregorio.
1 Project supervised by: Dr Michael Gandelsman Project performed by: Roman Paleria, Avi Yona 12/5/2003 Multi-channel Data Acquisition System Mid-Term Presentation.
Double buffer SDRAM Memory Controller Presented by: Yael Dresner Andre Steiner Instructed by: Michael Levilov Project Number: D0713.
Infineon Technologies Corp. June 99 1 HOT167-1 Version 2.0 F PWMmax = x 50ns = 78 kHz Pulse Width Modulation Unit (PWM) (20 MHz)  4 independent.
1 Project supervised by: Dr Michael Gandelsman Project performed by: Roman Paleria, Avi Yona 26/4/2004 Multi-channel Data Acquisition System Final_A Presentation.
Phase Noise and Noise Measurement Pengcheng Jia Nov 21, 2002.
MUST HAVE SHOULD HAVE COULD HAVE Module # 010. Qi Hardware Objectives Recognize hardware Know how to interface to field equipment Know the 4 different.
P-Series presentation May 2005 N191X Power Meters and N192X Power Sensors Agilent’s P-Series power meters and power sensors provide wide bandwidth, fast,
2.4GHz Single Balanced Mixer Andrew Bacon Jacqueline Griffin John Stone.
Coaxial cables measurement Identification method of damaged cables or bad connectors mounting Stéphane Rey – BE/RF – September.
Scale Power Measurement Pengcheng Jia Nov 21, 2002.
Spectrum Analyzer Basics Copyright 2000 Agenda Overview: What is spectrum analysis? What measurements do we make? Theory of Operation: Spectrum analyzer.
Spectrum Analyzer Basics Copyright 2000 Agenda Overview: What is spectrum analysis? What measurements do we make? Theory of Operation: Spectrum analyzer.
POWER PLANT USED IN TELECOM
Namaste Project 3.4 GHz Interference Study Preliminary document - Work in Progress updated The intent of this study is to collect data which may.
High Speed Data Converter University
Single Ended Measuring Modes of ELQ 30A To learn more click on the selected topic! ELEKTR NIKA Receiving Modes Impulse Noise Measurement Spectrum Analyzer.
MagicInfo Pro Scheduler Now that a template has been created from content imported into the Library, the user is ready to begin scheduling content to.
Introduction to Controlling the Output Power of a Transistor Stage A load network will be designed to maximize the output power obtainable from the Mitsubishi.
Gauge Operation and Software by Scott A. Ager. Computer Recommendations 750 MHz Pentium III 64 Meg SRAM 40 Gig Hard Drive 1024 x 768 graphics CD Writer.
Performance test and VNAPT. Purpose of Performance test Performance test will check the VNA’s performance to make sure it’s all within the specifications,
Advances In Millimeter Wave Measurements Banded Differential and Pulse Measurements.
Copyright © 2014 Wild River Technology LLC Slide 1 Wild River Technology LLC Alfred P. Neves phone
Analog Discovery Arbitrary Function Generator for Windows 7 by Mr
Network Analyzers From Small Signal To Large Signal Measurements
Copyright 2010 ITRI 工業技術研究院 1 Agilent 35670A Operator’s Guide Different types of measurement. Rotating Machinery Structures(FRF) Sound/Acoustics Spectra.
SPECTRUM ANALYZER 9 kHz GHz
© Nokia 1255_RF_Training / Jan 2006 / CFSCompany Confidential 1255 Technical Training RF Troubleshooting Presentation NMP-CDMA, San Diego Jan, 2006.
TS9975 Konyang University 20 th July to 22 nd July 05.
University of Kansas 2004 ITTC Summer Lecture Series Network Analyzer Operation John Paden.
Beyond S-Parameters © Agilent Technologies, Inc Aerospace and Defense Symposium 2007 EuMw 2007 Agilent Workshop Page M6- 1 Hot S22 Measurements.
The Interconnect Modeling Company™ High-Speed Interconnect Measurements and Modeling Dima Smolyansky TDA Systems, Inc.
VLBI2010 Phase Calibration Signal Generator and Broadband Considerations Christopher Beaudoin Research Engineer MIT Haystack Observatory.
RADITEK inc RADITEK-RFTS-M1-L21WORLD HQ: 1702L Meridian Ave. Suite 127, San Jose, Ca 95125, U.S.A. Tel: (408) FAX: (408) WEB:
Present Uses of the Fermilab Digital Signal Receiver VXI Module Brian Chase,Paul Joireman, Philip Varghese RF Embedded Systems (LLRF) Group.
IC-CAP Modeling Configuration Agilent Technologies November 01, 2005 Page 1 Agilent IC-CAP Modeling Configuration - Block Diagram ( GHz) GPIB.
8133A Overview. 8133A Overview 10-Feb04 Page A Overview 1) Specifications and Applications 2) Operational Overview 3) Block Diagram.
Calibration of vector network analyzer R&S ZVL. 1.Analyzer is set to pre-defined state (PRESET) 2.Requested central frequency is set (CENTER). 3.Requested.
Electrical Testers Basic test equipment used in today’s shops may include an analog type meter, a VAT (Volt-Amp-Tester), DMM (Digital Multimeter),
Automatic Guitar Tuner Group #10 Dariusz Prokopczak & Stephan Erickson ECE 445 Sr. Design December 9, 2014.
4 August An Interlaboratory Comparison of 3.5 mm Coaxial 2-Port Vector Network Analyzer Measurements 4 August 2008 Li Pi Su, Dexter Shelton, George.
DMR Tuner Training Document.
Single Ended Measuring Modes of ELQ 30A+
NSG 4070 Signal generator and immunity test system Dr. Heinrich
Timer and Interrupts.
Slide 1 Portfolio Positioning Site Master VNA Master Spectrum Master BTS/Cell Master LMR Master Value Performance Models88941 Cable & Antenna1.6 / 4 /
Sub – 1 Ohm Broadband Impedance Matching Network
pocketVNA What is a Vector Network Analyzer?
Antenna Analyzer EA4FRB
TB8100 Technical Training July 2005
McCrometer Nano Board Test Procedure
Wavewin Sniffer 24 Configuration & Polling Software
Antenna Analyzer EA4FRB
Presentation transcript:

Introduction to 85108A Pulsed Network Analyzers Pengcheng Jia Dec 13, 2001

Outline What is measurement? What is Pulsed Network Analyzer? What are the Connectors & Cables? What are the Calibration Kits? What is Non-Insertable Calibration? How to do Pulsed Measurement? How to Control by Computer?

What is measurement Define Measurement: f, P, T, expected values and tolerance. Define System Configuration Configure Hardware: ESD Protection User setting, Gauging,Always use ESD Protection Check Hardware: DUT, Cables, Connectors Calibrate Verify Measure Analyze and Archive

Measure S Parameters

85108A System Configuration

System Cabling Diagram 2 Bands Test Set works from 1-50 GHz in 2 Bands: 1-20 GHz 1-20 GHz Use directly LO source GHz 6-50 GHz Use third harmonic of LO source. LO source: 10M-20 G RF source: 10M-50 G Test Set: 1-50 GHz

85110A Test Set Signal Flow

Simplified NA D 50 MHz to 40 GHz 100 dB of dynamic range Excellent measurement accuracy Two measurement channels Four display channels

Difference: 85108A—8722D 8722D85108A Freq Range50M-40G1-20G,6-50G AccuracyN/A0.01dB Pulsed RFNY Pulse Profile (Time Domain)NY Sweep ModeRamp ModeStep Mode IF Bandwidth3KHz1.5MHz, 10KHz High Power Meas.NY

Avoid Large Time Delay of DUT f t Ramp Mode: 8722D Frequency Sweep f t Step Mode: 85108A 200 ms DUT  =10 ns 8722D with 3K IF BW Original f 4KHz 3KHz BW Ramped

Pulse Meas.- Freq Domain Point-in-Pulse Freq Domain Meas. Use 1.5M Broadband IF filter (Normal meas. use 10K IF filter) Adjustable Duty Cycle Default: 10% Adjustable Pulse Width Default: 10 ms, min 1us Trigger time: 5ms from 0

Pulse Meas.-Time Domain Display Time Domain Pulse Profile Choose Pulse Profile in Domain menu Measure only at a single frequency

High Power Meas. Never Exceed the Power Limitation on the Test Port Port1 & Port2: +43 dBm RF Input Port: +17 dBm +17 dBm +43 dBm

Connectors for NA ConnectorDielectricFreqMate with WrenchNote SMAYes18G3.5, 2.95lb.inNot recommend to mate with 3.5, No26.5GSMA,2.98lb.inHP PSC connector 2.9(K)No40GSMA,3.58lb.inHP PSC, Wiltron K 2.4No50G1.858lb.inHP PSC 1.85(V)Yes65G2.4HP PSC, Wiltron V PSC: Precision Slotless Connector

Cables for NA Connectors on Port 1 & 2 is 2.4 mm Never Remove Them 2.4 to 2.9 (K) adaptors are put to mate with K connector cables, Never Remove Them Always Keep Connects & Adaptors Clean Always Keep Connects & Adaptors Clean Treat Them Gentle and Put Back to Box Treat Them Gentle and Put Back to Box Cables (only following cables can be used for NA): Semi-Rigid with K connectors Flexible—Thin Jacket with K connectors (Blue, from Gore) Flexible—Thick Jacket with 2.4 mm connectors (Black, from Agilent)

Cautions: Select Correct Cal Kit and Load Calibration Constants before Calibration Select Correct Cal Kit and Load Calibration Constants before Calibration Never Remove a Calibration Standard from the Box or Use for Any Purpose Other Than Calibration Never Remove a Calibration Standard from the Box or Use for Any Purpose Other Than Calibration Never Drop the Standards to Ground Never Drop the Standards to Ground Always Use Special Wrench Correctly Always Use Special Wrench Correctly Put the Cal Kits Back to Cabinet after Use Put the Cal Kits Back to Cabinet after Use Report Any Discrepancy Report Any Discrepancy

Load Configuration Disk Load the Test Set Configuration Disk for 85110A with H60/61 option (Disks are stored in Drawers, never remove them) Disk->Storage is Internal Load->More->Machine Dump MD_1_20_NP, 1-20 GHz, Non-Pulsed MD_1_20_PL, 1-20 GHz, Pulsed MD_6_50_NP, 6-50 GHz, Non-Pulsed MD_6_50_NP, 6-50 GHz, Pulsed

Calibration Procedure Press Cal menu Choose Calibration Kit, if not installed in equipment, load the cal constant from disk Choose in the Calibration Menu LRM for on-wafer Calibration, Full 2-port for cable calibration Follow instruction, connect standards and measure Save calibration data You will see “Correction On”

Error Model for Full 2-Port Cal

Calibration Non-Insertable DUT

Swap Equal Adaptors Swap Equal Between- Series Adaptors Swap Equal In-Family Adaptors

Adaptor Removal Refer the additional document for more details More calibration methods are included in that file Calibration with adaptor on Port 2, save as Cal Set 1 Calibration with adaptor on Port 1, save as Cal Set 1 Modify Cal Set->Adaptor Removal

Calibration with On-Wafer Kit Use WinCal on Controller-Dizzy Calibration Constant is set in program Choose LRM, since short is not good LRRM is recommended for more accuracy

How to do Pulsed Meas.(1) Frequency Domain (Point-in-Pulse) Domain->Frequency System->More->Pulse Config->Detector: Wide BW Wide BW Select Maximum Points Calibration System->More-> Pulse Config-> High or Low Set Pulse Width, Duty Cycle Stimulus->More->Trigger Mode->Trigger Delay Measure

How to do Pulsed Meas.(2) Pulse Profile Domain - Single Frequency Domain->Frequency Stimulus->Step mode & Start->Set desired frequency Domain->Pulse Profile Select Maximum Points Calibration Measure Repeat for Next Frequency

How to do Pulsed Meas.(3) Pulse Profile Domain – Frequency List Cal->Correction off Domain->Frequency System->More->Pulse Config->Detector: Wide BW Stimulus->More->Edit List Add->Start->3 G/n, Number of Points->51x1->Done Add->Start->4 G/n x1->Done Add->Start->5 G/n x1->Done Done Frequency List, and Proceed with Calibration

How to do Pulsed Meas.(4) Using Frequency List – Continue: When begin to Measure: Domain-> Pulse Profile Stimulus->Frequency List->Single Segement The last selected segment will be active and ready for measurement Calibration will be effective for each frequency point Set Pulse Polarity, Pulse Width and Duty cycle if needed

Computer Control 2 GPIB Connectors are on the back of 8510C 1 for System bus (don’t touch) 1 for computer controller (already connected) Dizzy is the controller Use WinCal for On-Wafer Calibration and S- Parameter Measurement Choose the correct VNA first Config->Option->VNA->8510 or 8722 Use Labview Program for configuration