Understanding Your QC Presentation to: KWWOA April 15, 2015 Department for Environmental Protection Energy & Environment Cabinet To Protect and Enhance.

Slides:



Advertisements
Similar presentations
Radiochemical Methods and Data Evaluation
Advertisements

Why Lab. Certification? Laboratory certification tries to insure that the laboratory is qualified and capable of analyzing the sample and obtaining quality.
Quality is a Lousy Idea-
UNDERSTANDING ENVIRONMENTAL LABORATORY/QC REPORTS Maya Murshak – Merit Laboratories, Inc.
1 Method Selection and Development l Initial Considerations n What does the method need to do? 3 What analyte/s need to be assayed? 3 What range or concentration.
Errors in Chemical Analyses: Assessing the Quality of Results
Quality in Environmental Analysis Tuesday, June 27, 2000 Goldwater Center Room 487.
Result validation. Exercise 1 You’ve done an analysis to the best of your ability using the correct procedure. Is your answer correct? possibly, hopefully.
Interpreting Your Lab Report & Quality Control Results
World Health Organization
Lecture 8. Quality Assurance/Quality Control The Islamic University of Gaza- Environmental Engineering Department Environmental Measurements (EENV 4244)
Quality Assurance.
UNIVERSITY OF HOUSTON - CLEAR LAKE Quality product (or service) as one that is free of defects and performs those functions for which it was designed.
Short Course on Introduction to Meteorological Instrumentation and Observations Techniques QA and QC Procedures Short Course on Introduction to Meteorological.
Quality Assurance/Quality Control Policy
QA/QC FOR ENVIRONMENTAL MEASUREMENT Unit 4: Module 13, Lecture 2.
QUALITY CONTROL OF PHYSICO-Chemical METHODS Introduction :Validation توثيق المصدوقية.
Chemometrics Method comparison
Unit #7 - Basic Quality Control for the Clinical Laboratory
Project co- financed by Asean European Committee for Standardization Implementing Agency Project co-financed by European Union Module 7 GMP Workshop Kuala.
Quality Assurance.
Quality Assessment 2 Quality Control.
Quality Control In Measurements Tom Colella CLAS Goldwater Environmental Lab.
Field Analysis Quality Control
Debra Waller NJDEP-Office of Quality Assurance
WWLC Standard Operating Procedures Presented by Frank Hall, Laboratory Certification Coordinator.
VALIDATION METHODOLOGY
The following minimum specified ranges should be considered: Drug substance or a finished (drug) product 80 to 120 % of the test concentration Content.
Analytical considerations
Laboratory Technical Issues Presentation to: KWWOA April 9, 2014 Department for Environmental Protection Environmental & Public Protection Cabinet To Protect.
Fundamentals of Writing an Effective QAP Presentation to: KWWOA April 15, 2013 Department for Environmental Protection Energy & Environment Cabinet To.
Quality WHAT IS QUALITY
How to Select a Test Method Marlene Moore Advanced Systems, Inc. June 15, 2010.
Quality Assurance Plan (QAP) Department for Environmental Protection Environmental & Public Protection Cabinet To Protect and Enhance Kentucky’s Environment.
QA/QC and QUALIFIERS LOU ANN FISHER CITY OF STILLWATER, OK
Chapter 5 Errors In Chemical Analyses Mean, arithmetic mean, and average (x) are synonyms for the quantity obtained by dividing the sum of replicate measurements.
Quality Control Lecture 5
Laboratory QA/QC An Overview.
Wastewater Laboratory Certification Presented at: KWWOA April17,
Quality Assurance How do you know your results are correct? How confident are you?
5. Quality Assurance and Calibration Quality assurance is We do to get the right answer for our purpose. Have Sufficient accuracy and precision to support.
Laboratory Certification Update Part 2 Common Findings KWWOA Louisville April 15, 2015 Presented by Frank Hall, Laboratory Certification Coordinator.
Validation Defination Establishing documentary evidence which provides a high degree of assurance that specification process will consistently produce.
Data Quality Assurance/ Quality Control. QA/QC Requirements for RECAP Submittals Data generated using rigorous analytical methods Data must be analyte.
Wenclawiak, B.: Fit for Purpose – A Customers View© Springer-Verlag Berlin Heidelberg 2003 In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in.
Control Charts and Trend Analysis for ISO 17025
Quality Control Internal QC External QC. -Monitors a test's method precision and analytical bias. -Preparation of quality control samples and their interpretation.
LECTURE 13 QUALITY ASSURANCE METHOD VALIDATION
George E. Detsis Manager, Analytical Services Program United States Department of Energy Office of Health, Safety and Security Office of Sustainability.
SEMINAR ON PRESENTED BY BRAHMABHATT BANSARI K. M. PHARM PART DEPARTMENT OF PHARMACEUTICS AND PHARMACEUTICAL TECHNOLGY L. M. COLLEGE OF PHARMACY.
EQUIPMENT and METHOD VALIDATION
이 장 우. 1. Introduction  HPLC-MS/MS methodology achieved its preferred status -Highly selective and effectively eliminated interference -Without.
Quality is a Lousy Idea-
The 2015/2016 TNI Standard and the EPA MDL Update
Unit #6 - Basic Quality Control for the Clinical Laboratory
EPA Method Equivalency
Janice L. Willey Senior Chemist
Quality is a Lousy Idea-
This teaching material has been made freely available by the KEMRI-Wellcome Trust (Kilifi, Kenya). You can freely download,
EPA Method Equivalency
What it Means, Why it Works, and How to Comply
Analytical Method Validation
METHOD VALIDATION: AN ESSENTIAL COMPONENT OF THE MEASUREMENT PROCESS
Chapter 5 Quality Assurance and Calibration Methods
Why Use Them? By: Marcy Bolek – Alloway
Environmental Laboratory Certification Program (ELCP)
Introduction To Medical Technology
Quality Control Lecture 3
Quality Assessment The goal of laboratory analysis is to provide the accurate, reliable and timeliness result Quality assurance The overall program that.
The 2016 TNI Chemistry Standard
Presentation transcript:

Understanding Your QC Presentation to: KWWOA April 15, 2015 Department for Environmental Protection Energy & Environment Cabinet To Protect and Enhance Kentucky’s Environment

Outline Define QA/QC Define types of QC sample analysis Acceptable laboratory QC practices

Definitions

Quality Assurance: An integrated system of management activities involving planning, quality control, quality assessment, reporting, and quality improvement to ensure that a product or service meets defined standards of quality with a stated level of confidence.

Definitions Quality Control: The overall system of technical activities whose purpose is to measure and control the quality of a product or service so that it meets the needs of the users; operational techniques and activities that are used to fulfill requirements for quality.

Definitions Contamination: The act of contaminating, or of making something impure or unsuitable by contact with something unclean, bad, etc.

Definitions Accuracy: A measure of the closeness of an individual measurement or the average of a number of measurements to the true value. Accuracy includes a combination of random error (precision) and systematic error (bias) components which are due to sampling and analytical operations. Refer to Standard Methods, Data Quality Section for a more detailed explanation.

Definitions Precision: The closeness of repeated measurements on the same parameter within a sample.

Precision vs. Accuracy

Types of QC Analysis

QC Samples QC before beginning analysis –Initial Demonstration of Capability (IDC) –Method Detection Limit (MDL)

QC Samples Blanks –Reagent Blanks/Method Blanks –Calibration Blank –Field Blanks –Equipment Blank –Trip Blanks –Instrument Blank –Temperature Blank

QC Samples Standards –Calibration Standards –Calibration Verification Standards Initial (ICV) Continuing (CCV) –Laboratory Control Spikes/Lab Fortified Blanks (LCS/LFB) –Quality Control Standard (QCS) –Proficiency Test (PT)

QC Samples Sample QC –Duplicates –Laboratory Fortified Matrix Spikes (LFMS) –Laboratory Fortified Matrix Spike Duplicates (LFMSD) –Field Spikes –Surrogate/Internal Standard

Acceptable Laboratory QC Practices

Initial QC IDC –4 replicates –Mid range (can be LCS/QCS) –Analyzed by each analyst under the supervision of an experienced analyst –Demonstrates accuracy and precision

Initial QC MDL –40 CFR 136, Appendix B –7 replicates –Analyzed on 2-3 nonconsecutive days –Can be performed on multiple instruments and by multiple analysts –Calculated MDL < 10 x Spike Level </=Regulatory Required Minimum Reporting Level –MDL calculation = (S)(t-value) S = standard deviation t-value for 7 replicates = 3.143

Initial QC Revised MDL Procedures –Proposed procedures in 2015 MUR –7 spikes and 7 blanks –Analyzed in at least 3 different batches –It includes instructions for multiple instruments –Requires ongoing (quarterly) spikes –Recalculate every year (but not redo) –Includes matrix specific MDL instructions –Calculate standard deviation of spikes and blanks; choose whichever is higher as MDL

Reagent Blanks/Method Blanks Reagent Blanks/Method Blanks (LRB/MB) –It is an aliquot of reagent water or other blank matrix that is treated exactly as a sample including exposure to all glassware, equipment, solvents, reagents, internal standards, and surrogates that are used with other samples. The LRB is used to determine if method analytes or other interferences are present in the laboratory environment, the reagents, or the apparatus.

Calibration Blank –A volume of reagent water acidified with the same acid matrix as in the calibration standards. The calibration blank is a zero standard and is used to auto-zero the AA instrument.

Field Blanks Field Blanks (FRB) –An aliquot of reagent water or other blank matrix that is placed in a sample container in the laboratory and treated as a sample in all respects, including shipment to the sampling site, exposure to sampling site conditions, storage, preservation, and all analytical procedures. The purpose of the FRB is to determine if method analytes or other interferences are present in the field environment.

Equipment Blanks –A sample of analyte free water poured over or through decontaminated field sampling equipment prior to the collection of environmental samples. It is used to assess the adequacy of the decontamination process. It is also used to assess contamination from the total sampling, sample preparation and measurement process, when decontaminated sampling equipment is used to collect samples.

Trip Blanks Trip Blanks (TB) –Analyte free water that is taken from the laboratory to the sampling site and transported back to the laboratory without having been exposed to sampling procedures. Typically, analyzed only for volatile compounds. It is used to assess contamination introduced during shipping and field handling procedures. –Typically analyzed only when an associated sample has a positive result.

Instrument Blanks Instrument Blanks (IB) –A blank analyzed with field samples. It is used to assess the presence or absence of instrument contamination.

Temperature Blanks –Not actually a blank but a VOA vial or other small sample bottle filled with distilled water that is placed in each cooler. Upon arrival at the laboratory, the temperature of this vial is measured. The temperature indicator or blank is not analyzed and does not measure introduced contamination, therefore, is not a blank. It is used to evaluate if samples were adequately cooled during sample shipment

Blank Acceptance Criteria Typical blank acceptance criteria is < ½ MRL Can be as high as < MRL Some methods specify < Calculated MDL

Failed Blank Corrective Actions Identify and eliminate the source of contamination Analysis of samples is halted until contamination is eliminated; if not, all results must be qualified because they did not meet the performance criteria of the test method Samples analyzed with an associated contaminated blank must be re-prepped and re-analyzed

Calibration Standards –Minimum of 3 (prefer 5) + blank (See method for exact requirements) If using Quadratic, MUST be 5 –Cover entire reporting range –0.995 correlation coefficient –Do not force through 0 –Should have positive y-intercept –Low standard must be at or below the reporting limit –Certain standards may be eliminated as long as the required minimum number is still met If you drop from the low end, the MRL must be adjusted accordingly If you drop from the high end, the retained highest standard defines the range for reporting results without having to dilute Standards from the middle must not be dropped

Initial Calibration Verification (ICV) Initial (ICV) –Second source (preferably) –% difference = (actual ÷ theoretical) x 100 –Acceptance criteria varies by method –Corrective action for failures include: instrument maintenance, re-preparation of standards or recalibration

Continuing Calibration Verification (CCV) Continuing (CCV) –Same source as calibration standards When internal standards are used to quantitate samples, a continuing calibration verification standard shall be performed: –At the beginning of each analytical run, unless a calibration curve has been generated prior to samples being analyzed on the same day –After each group of 10 or 20 samples or after a 12-hour period, whichever comes first Continued…

Continuing Calibration Verification (CCV) Continued Continuing (CCV) –Same source as calibration standards When internal standards are not used to quantitate samples, a continuing calibration verification shall be performed: –At the beginning of each analytical run, unless a calibration curve has been generated prior to samples being analyzed on the same day –After each group of 10 or 20 samples or after a 12-hour period, whichever comes first –At the end of each analytical run Continued…

Continuing Calibration Verification (CCV) Continued Acceptance criteria (unless otherwise specified by method) –Within 10% of the standard concentration for reportable inorganic analytes and metals –Within 15% of the standard concentration for reportable organic analytes If the CCV fails: –The laboratory may take corrective action and re- analyze –After 2 consecutive failed CCVs, the laboratory must recalibrate –Bracketed samples must be re-prepped and re- analyzed

Standards Control Spikes/Lab Fortified Blanks (LCS/LFB) –Typically second source from calibration standards 1/20 samples Acceptance criteria varies by method –Quality Control Standard (QCS) Same as LCS/LFB but purchased or made at analyzed concentration –Cannot prove matrix interference with QCS analysis Reporting Limit Standard (RLS) –A procedural standard that is analyzed to evaluate instrument performance at or below the minimum reporting limit Analyzed after each calibration or at least once per quarter

Proficiency Test Proficiency Test (PT) –Must pass annually –Must be analyzed exactly like samples –Must be submitted to state by the PT provider to be valid –PT should be in range of normal sample results –Separate studies for DW & KPDES –2 consecutive analyte failures must be reported to the State

Duplicates –May be sample or QC A duplicate sample is a second portion (aliquot) of the same sample that is tested by using the same analytical procedures 1/20 samples + 20% RPD % RPD = (|difference|) x 100 average

Matrix Spikes Laboratory Fortified Matrix Spikes (LFMS) –Used to evaluate the performance of an analytical procedure when testing a specific sample (matrix) type –Made by adding a known amount (a spike) of analyte to a sample, testing the spiked sample, and determining if you have recovered the amount that you added

Matrix Spikes Spiking Solution –A standard that is chosen for preparing a matrix spike –The concentration of the analyte in the spiking solution is usually times higher than the concentration found in the unspiked sample This concentration is chosen to ensure that the spike does not significantly change the sample volume This simplifies the calculations and avoids introducing unknown effects from dilution of the matrix The spike should not increase the sample volume by more than 5%. Otherwise, it must be taken into account

Matrix Spikes Matrix Spike concentration –For routine quality control purposes, it is recommended to prepare and analyze one matrix spike sample for each batch of 10 or 20 samples. In this case, the spike concentration should be chosen to fall in the middle of the analytical method range –It is important to remember that the concentration of the spiked sample should be within the method range(e.g. within the calibration curve). If necessary, dilute the spiked sample (after spiking) to bring the measurement within the calibration curve

Matrix Spikes Preparing a Matrix Spike Choose a spiking level Determine the concentration of the spiking solution to be used Determine the amount of spiking solution to be added to the sample as follows: Add the calculated volume of spiking solution Analyze the spiked sample using the same analytical procedure as for the unspiked sample Calculate the percent recovery of the spike as follows:

Traceability The ability to follow the history, application, or location of an item or activity by means of recorded identifications; for calibration, this relates measuring equipment to national or international standards, primary standards, basic physical constants or properties, or reference materials, and, for data collection processes, this relates to calculations and data generated throughout the project back to the requirements for the quality of the project.

QED The Latin phrase quod erat demonstrandum ‘What I set out to prove’ Data of Known Quality –Properly documented or recorded –Free of contamination –Free of any bias –Reproducible

Questions?? Comments?? Kevin Stewart Laboratory Auditor KY Division of Water (502) extension 4985