CVD diamond detector as a beam monitor for a high intensity and high luminosity accelerator Kodai Matsuoka (Kyoto Univ.) for T2K muon monitor group.

Slides:



Advertisements
Similar presentations
Epitaxial Silicon Detectors for Particle Tracking Overview on Radiation Tolerance at Extreme Hadron Fluence G. Lindström (a), E. Fretwurst (a), F. Hönniger.
Advertisements

Beam direction and flux measured by MUMON K. Matsuoka (Kyoto) for the MUMON group Contents: 1.Beam stability (direction/flux) 2.Absolute  beam flux.
Trapping in silicon detectors G. Kramberger Jožef Stefan Institute, Ljubljana Slovenia G. Kramberger, Trapping in silicon detectors, Aug , 2006,
Design Studies and Sensor Test for the Beam Calorimeter of the ILC Detector E. Kuznetsova DESY Zeuthen.
Diamond Manufacturers for ATLAS Upgrades March 26, 20121R. Kass Brief Overview: Next Upgrade (IBL): Diamond Beam Monitor (DBM) News from two diamond manufacturers.
T2K neutrino experiment at JPARC Approved since 2003, first beam in April Priorities : 1. search for, and measurement of,   e appearance  sin.
For the RD42 Collaboration
May 14th 2004RD42 collaboration meeting1 Results with a CVD diamond at the K2K beam-line Jun Kubota(Kyoto Univ.) RD42 collaboration meeting May 14 th 2004.
Kara Hoffman Mark Oreglia. A promising bolometric material: platinum high Z = large dE/dx temperature-resistivity function very steep at 20K should.
Short ( and incomplete) characteristics of CVD diamond detectors Diamond as a detector material low dielectric constant low capacity low noise good heat.
Measurements on single and poly crystal diamond samples at CERN Luis Fernandez-Hernando Christoph Ilgner Alick Macpherson Alexander Oh Terry Pritchard.
Investigation of the properties of diamond radiation detectors
Slide 1 Diamonds in Flash Steve Schnetzer Rd42 Collaboration Meeting May 14.
Diamonds in CDF Peter Dong, UCLA Ricardo Eusebi, FNAL Anna Sfyrla, Geneva Rick Tesarek, FNAL Rainer Wallny, UCLA With much help from Jonathan Lewis (FNAL)
Design and test of a high-speed beam monitor for hardon therapy H. Pernegger on behalf of Erich Griesmayer Fachhochschule Wr. Neustadt/Fotec Austria (H.
T2K experiment at J-PARC Epiphany 2010D. Kiełczewska1 For T2K Collaboration Danuta Kiełczewska Warsaw University & Sołtan Institute for Nuclear Studies.
1 Semiconductor Detectors  It may be that when this class is taught 10 years on, we may only study semiconductor detectors  In general, silicon provides.
Techniques for determination of deep level trap parameters in irradiated silicon detectors AUTHOR: Irena Dolenc ADVISOR: prof. dr. Vladimir Cindro.
11 th RD50 Workshop, CERN Nov Results with thin and standard p-type detectors after heavy neutron irradiation G. Casse.
Fast Timing with Diamond Detectors Lianne Scruton.
22 December 20143rd FCAL Hardware WG Meeting 1 BeamCal sensors overview Sergej Schuwalow, DESY Hamburg.
NEW COMMENTS TO ILC BEAM ENERGY MEASUREMENTS BASED ON SYNCHROTRON RADIATION FROM MAGNETIC SPECTROMETER E.Syresin, B. Zalikhanov-DLNP, JINR R. Makarov-MSU.
22 October 2009FCAL workshop, Geneve1 Polarization effects in the radiation damaged scCVD Diamond detectors Sergej Schuwalow, DESY Zeuthen On behalf of.
Development of Multi-pixel photon counters(2) M.Taguchi, T.Nakaya, M.Yokoyama, S.Gomi(kyoto) T.Nakadaira, K.Yoshimura(KEK) for KEKDTP photon sensor group.
Laser Stripping and H 0 monitor systems 10/18/2011B.Cheymol, E. Bravin, U. Raich, F. Roncarolo BE/BI1.
Status of the NO ν A Near Detector Prototype Timothy Kutnink Iowa State University For the NOvA Collaboration.
The Earth Matter Effect in the T2KK Experiment Ken-ichi Senda Grad. Univ. for Adv. Studies.
Photodetection EDIT Internal photoelectric effect in Si Band gap (T=300K) = 1.12 eV (~1100 nm) More than 1 photoelectron can be created by light in silicon.
14 December nd CARAT Workshop, GSI, Darmstadt1 Radiation hardness studies with relativistic electrons Sergej Schuwalow, Uni-HH / DESY On behalf of.
Status of Beam loss Monitoring on CTF3 Results of Tests on LINAC and PETS as R&D for TBL Anne Dabrowski Northwestern University Thibaut Lefevre CERN CTF3.
High Dose Irradiation of Possible FCAL Sensors at the S-DALINAC Ch.Grah Physics and Detector Meeting DESY HH,
Development of Multi-pixel photon counters(2) M.Taguchi, T.Nakaya, M.Yokoyama, S.Gomi(kyoto) T.Nakadaira, K.Yoshimura(KEK)
1 DISCOVERY OF ATMOSPHERIC MUON NEUTRINO OSCILLATIONS Prologue First Hint in Kamiokande Second Hint in Kamiokande Evidence found in Super-Kamiokande Nov-12.
Diamond Detector Developments at DESY and Measurements on homoepitaxial sCVD Diamond Christian Grah - DESY Zeuthen 2 nd NoRHDia Workshop at GSI Thursday,
Polycrystalline CVD Diamonds for the Beam Calorimeter of the ILC C. Grah 1, U. Harder 1, H. Henschel 1, E. Kouznetsova 1, W. Lange 1, W. Lohmann 1, M.
Diamond Sensor Diamond Sensor for Particle Detection Maria Hempel Beam Impact Meeting Geneva,
8 July 1999A. Peisert, N. Zamiatin1 Silicon Detectors Status Anna Peisert, Cern Nikolai Zamiatin, JINR Plan Design R&D results Specifications Status of.
Shan Liu, Philip Bambade, Sha Bai, Dou Wang, Illia Khvastunov ECFA, Hamburg, 29 May, 2013.
G. Steinbrück, University of Hamburg, SLHC Workshop, Perugia, 3-4 April Epitaxial Silicon Detectors for Particle Tracking Overview on Radiation Tolerance.
3rd NoRDHia 1 TITLE INVESTIGATION OF DIAMOND SAMPLES UNDER HIGH DOSES OF ELECTROMAGNETIC IRRADIATION (at S-DALINAC) Wolfgang Lange, DESY Zeuthen.
K. Matsuoka (Kyoto Univ.) for T2K muon monitor group
Charles University Prague Charles University Prague Institute of Particle and Nuclear Physics Absolute charge measurements using laser setup Pavel Bažant,
A Prototype Diamond Detector for the Compton Polarimeter in Jefferson lab, Hall C Medium Energy Physics Group Amrendra.
1 Status of the T2K long baseline neutrino oscillation experiment Atsuko K. Ichikawa (Kyoto univeristy) For the T2K Collaboration.
T2K Status Report. The Accelerator Complex a Beamline Performance 3 First T2K run completed January to June x protons accumulated.
Polycrystalline CVD Diamonds for the Beam Calorimeter of the ILC C.Grah ILC ECFA 2006 Valencia, 9 th November 2006.
1 Performance of a CCD tracker at room temperature T. Tsukamoto (Saga Univ.) T. Kuniya, H. Watanabe (Saga Univ.); A. Miyamoto, Y. Sugimoto (KEK); S. Takahashi,
Beam direction and flux measured by MUMON K. Matsuoka (Kyoto) for the MUMON group Contents: 1.Horn focusing effect 2.Beam stability (direction/flux) 3.Beam.
XLVth Rencontres de Moriond Status of the T2K experiment K. Matsuoka (Kyoto Univ.) for the T2K collaboration Contents Physics motivations (neutrino oscillation)
CNS CVD Diamond S. Michimasa. Properties of diamond Extreme mechanical hardness and extreme high thermal conductivity Broad optical transparency in region.
Philip Bambade, Pierre Barillon, Frédéric Bogard, Selma Conforti, Patrick Cornebise, Shan Liu, Illia Khvastunov Journée PHIL
C. Weiss 1, 2, G. Badurek 2, E. Berthoumieux 3, M. Calviani 1, E. Chiaveri 1, D. Dobos 1, E. Griesmayer 4,C. Guerrero 1,E. Jericha 2, F. Kaeppeler 5, H.
Observation Gamma rays from neutral current quasi-elastic in the T2K experiment Huang Kunxian for half of T2K collaboration Mar. 24, Univ.
Development of Multi-pixel photon counters(2) M.Taguchi, T.Nakaya, M.Yokoyama, S.Gomi(kyoto) T.Nakadaira, K.Yoshimura(KEK) for KEKDTP photon sensor group.
RD05 Florence CVD Diamond Radiation Sensors For Application In Very High Radiation Environments 7 th International Conference on Large Scale Applications.
Neutrinoless double beta decay (0  ) CdTe Semico nductor Band gap (eV) Electron mobility (cm 2 /V/s) Hole mobility (cm 2 /V/s) Density (g/cm 3.
T2K Experiment Results & Prospects Alfons Weber University of Oxford & STFC/RAL For the T2K Collaboration.
Manoj B. Jadhav Supervisor Prof. Raghava Varma I.I.T. Bombay PANDA Collaboration Meeting, PARIS – September 11, 2012.
Characterization of muon beam in T2K with emulsion detectors A. Ariga, T. Ariga, C. Pistillo AEC-LHEP University of Bern 1.
K2K and JHF-nu muon monitor Jun Kameda (KEK) 1. K2K muon monitor 2. JHF-ν muon monitor 3. Summary International workshop on Neutrino Beam Instrumentation,
Radiation hardness tests of GaAs and Si sensors at JINR S. M
K2K and JHF-nu muon monitor
Investigation of diamond sensors for calorimetry
Development of the muon monitor for the T2K experiment
FCPPL, Clermont-Ferrand , 8-10 April, 2014
大強度
CCE measurements with Epi-Si detectors
Semiconductor Detectors
PHYS 3446 – Lecture #17 Wednesday ,April 4, 2012 Dr. Brandt
Gain measurements of Chromium GEM foils
Presentation transcript:

CVD diamond detector as a beam monitor for a high intensity and high luminosity accelerator Kodai Matsuoka (Kyoto Univ.) for T2K muon monitor group

2 Contents Introduction –Motivation Chemical Vapor Deposition (CVD) diamond –Properties –CVD diamond detectors in BaBar, Belle –A candidate for T2K muon monitor Beam test results of CVD diamond detectors –Bias voltage scan –Time dependence –Linearity Summary

3 Motivation to study CVD diamond detector A high intensity and high luminosity accelerator helps us to push back the frontiers in HEP. Need more radiation-hard detectors A new material tolerant of radiation: Chemical Vapor Deposition (CVD) diamond KEKB Luminosity: cm -2 s -1 J-PARC Intensity: 3.3 x proton / pulse

4 CVD diamond Formed by using a gas at low temp. (< 1000 °C) and low pressure (~0.1 atm) in a non-equilibrium process, Chemical Vapor Deposition (CVD) growth process. Produced economically over a large area and w/ high purity. Polycrystalline w/ a columnar structure of grains. Schematic diagram of a CVD reactor Scanning electron micrograph from the growth side of a CVD diamond sample 200 μm

5 Properties of diamond DiamondSi Band gap [eV] Electron mobility [cm 2 /Vs] Hole mobility [cm 2 /Vs] Saturation velocity [cm/s]2 x x 10 7 Dielectric constant e-h creation energy [eV]133.6 e-h pairs per MIP [μm -1 ]3689 Displacement energy [eV]4313 ~ 20 Decrease in charge collection after irradiation with 1 x proton/cm 2 * Not observed (by ~40 % at 5 x p/cm 2 ) No signal Low leakage cur. Low capacitance, noise High radiation hardness Fast signal collection * CERN-EP/98-79 (1998) Smaller signal (typically 1/5 of Si) … Diamond is a better material than silicon

6 Photo of BaBar device inside SVT CVD diamond CVD diamonds in BaBar SVTRAD system –Radiation monitoring and protection system to safeguard the Silicon Vertex Tracker (SVT) –Two CVD diamonds were installed in Aug to determine whether they presented a viable alternative to Si PIN photodiodes. No operation problems Lower noise than Si Plan to replace all the Si PIN photodiodes w/ CVD diamonds Cross-section view of SVT Support ribs Si PIN photodiode Be beam pipe Detector wafer

7 CVD diamonds in Belle Similar sensors as BaBar Installed just outside of Silicon Vertex Detector (SVD) CVD diamond has ever been no more than used as a radiation monitor. The performance is not clear yet. –Linearity –Stability –Reproducibility –Individuality CVD diamond Photo of Belle device outside SVD

8 T2K long baseline neutrino oscillation exp. Super-K 295 km J-PARC ~1 GeV ν μ beam Off-axis (OA) It is necessary to monitor the ν direction. Muon monitor Neutrino energy spectrum Energy maximizing ν oscillation probability

9 Muon monitor (MUMON) Monitor of secondary beam direction by monitoring profile of muons which pass through beam dump on a spill by spill basis. p π+π+ μ+μ+ νμνμ MUMON baseline design: an array of ionization chambers and an array of semiconductor detectors Beam

10 Requirements for MUMON system Stability Radiation hardness # of particles coming into MUMON 10 8 μ/cm 2 /spill 10 7 neutron/cm 2 /spill (1000 times as much as in K2K MUMON) A viable alternative to Si PIN photodiode is required for T2K MUMON. A new candidate: CVD diamond detector K2K MUMON: an ionization chamber hodoscope and an array of Si PIN photodiode

11 Beam test w/ electron Uji ICR CVD diamond detector Developed by CERN RD42 Active area: 9.5 x 9.5 mm 2 Thickness: 500 μm 9.5 mm Beam parameters 100 MeV electron Intensity > 10 7 e/spill Radius: ~2 cm Pulse width: ~40 ns Electron Inst. for Chem. Res. Kyoto Univ. Si PIN photodiode (as a ref.) 10 mm HAMAMATSU S Active area: 10 x 10 mm 2 Thickness: 300 μm

12 Measured items Bias voltage scan Time dependence the flux expected in T2K MUMON Beam profile Beam Diamonds Si (as a ref.) Schematic view of the test setup

13 Bias voltage scan The signal of diamond is ~1/5 of that of Si as expected. Bias voltage dependence is < 0.1 %/V at 500 V. Operation bias: 500 V Beam intensity: ~5 x 10 7 e/cm 2 /pulse Raw signal measured by oscilloscope ~80 ns ~800 ns Diamond1 (bias: 500 V) Si (bias: -80 V) The diamond signal is faster than Si.

14 Time dependence Stable within 0.5 % for 10 min. Beam intensity: ~5 x 10 7 e/cm 2 /pulse < ± 0.5 % Bias voltage on Beam on Pumping effect

15 Linearity The response of diamond is linear within 5.2 %. Si seems to be saturated at the higher intensities. Beam intensity: 10 7 ~ 10 8 e/cm 2 /pulse

16 Summary Intensity and luminosity frontiers has been improved. –Radiation-hard detectors are required. –CVD diamond is a new material tolerant of radiation. CVD diamond detectors in BaBar, Belle –Operated w/ no problem –Should surpass performance of Si. CVD diamond is a candidate for T2K MUMON. –We succeeded in the beam test of CVD diamonds. Bias voltage dependence < 0.1 %/V at 500 V Stable within 0.5 % for 10 min. Linear response within 5.2 % up to 10 8 e/spill (T2K full intensity) –There remain some issues to be considered. Individuality, Long-term stability, etc. CVD diamond is involving in real alternative for detectors in extreme radiation environments.

17

18 Supplement

19 Main goals of T2K 1.Search for ν e appearance, then determination of θ 13 2.Precise measurement of oscillation parameters, θ 23 and Δm 23 2, by ν μ disappearance 3.Search for sterile components in ν μ disappearance Expected sensitivities assuming 0.75MW and 170 days operation for five years –ν μ disappearance δ(Δm 23 2 ) = eV -2 δ(sin 2 2θ 23 ) = 0.01 –Discovery of ν μ ν e Δm 2 ~ 3 x eV -2 sin 2 2θ 13 ~ 0.006

20 Off-axis (OA) neutrino beam Off-axis ν flux at the desired energy is higher than on-axis flux. (Oscillation max. ~ 0.8 GeV for L = 295 km and Δm 2 ~ 3 x eV -2 ) There are few high energy neutrinos which contribute not to the appearance signal but to its background. Background due to intrinsic contamination of the beam by ν e is less than at on-axis position. Neutrino energy spectrum from OA beams

21 CVD diamond results in BaBar Fully correlated with nearby Si signal Provide very clean signal due to their tiny dark currents No operational problems Radiation-induced cur. in CVD diamond detector and Si PIN photodiode during typical operation of the accelerator

22 CVD diamond in K2K MUMON Beam K2K MUMON SSD-array CVD diamond Collected charge ratio of diamond / Si = 13.8 pC / 160 pC = 8.6 %

23 Pumping effect d(t) = d p [1 – r exp(-t / τ)] Charge collection distance in irradiation with 90 Sr source with an activity of 37Mrad τ = 64 min.