NIRCam DHAS and Array Characterization

Slides:



Advertisements
Similar presentations
AITA 9, MERTIS Team – MERTIS Calibration, Oct 2007 Folie 1 Development of a calibration concept for the MErcury Thermal Infrared Spectrometer Thomas Saeuberlich,
Advertisements

May 19, 2009JWST Partner's Workshop1 NIRCam Status Marcia Rieke University of Arizona JWST Partner’s Workshop Ottawa, Canada May 19, 2009 JWST-PRES
C. Beichman, Dimitra Touli, Gautam Vasisht, Roger Smith Tom Greene
Institute of Environmental Physics and Remote Sensing IUP/IFE-UB Physics/Electrical Engineering Department 1 Institute.
Analysis of chip with 100 events, July 2001 Variation in pixel to pixel average ADC values (fixed pattern noise) Pixel ADC value event to event repeatability.
SJC - 109/29/05IRAC Calibration Workshop Status of IRAC Artifact Corrector Sean Carey.
ABRF meeting 09 Light Microscopy Research Group. Why are there no standards? Imaging was largely an ultrastructure tool Digital imaging only common in.
1 NIRCam Monthly Science Team Telecon March 6, 2008.
EPIC Calibration Meeting, MPE K. Dennerl, 2006 May 04 EPIC pn at low energies: LW mode Properties of EPIC pn at low energies: LW mode.
1 Ultra low background characterization of Rockwell Scientific MBE HgCdTe arrays Donald N. B. Hall, University of Hawaii, Institute for Astronomy, Honolulu,
Stellar Linearity Test Jason Surace (Spitzer Science Center)
GLAST LAT ProjectOnline Peer Review – July 21, Integration and Test L. Miller 1 GLAST Large Area Telescope: I&T Integration Readiness Review.
Charge-Coupled Device (CCD)
Overview of Scientific Imaging using CCD Arrays Jaal Ghandhi Mechanical Engineering Univ. of Wisconsin-Madison.
Simulating JWST-MIRI data with the Multi-Object Simulator (MOSim) Owen Littlejohns, Paul O’Brien & John Pye Department of Physics & Astronomy University.
S. Baggett, J. Anderson, K. S. Long, J. W. MacKenty, K. Noeske, J. Biretta, and the WFC3 team (STScI) WFC3 : Understanding and mitigating UVIS charge.
0. To first order, the instrument is working very well ! 1.Evolution of the IR detector with time 2.Stability of the L channel 3.Saturation 4.Linearity.
1 TIPS 2011 May Persistence in the WFC3 IR detector Knox S. Long.
STEP 1: Determining the exact image width STEP 1: Determining the exact image width Position of X-ray Filter Position of X-ray Filter STEP 5: Crop Extra.
Coincidence analysis in ANTARES: Potassium-40 and muons  Brief overview of ANTARES experiment  Potassium-40 calibration technique  Adjacent floor coincidences.
Super-hot pixels, hot pixels and DSNU on Hawaii-2RG detector
Science Impact of Sensor Effects or How well do we need to understand our CCDs? Tony Tyson.
Beating Noise Observational Techniques ASTR 3010 Lecture 11 Textbook.
Understanding Persistence: A 3D Trap Map of an H2RG Imaging Sensor
NIRCam ETU Testing at LMATC, Palo Alto Kailash C. Sahu.
CCD Detectors CCD=“charge coupled device” Readout method:
Telescope Guiding with a HyViSI H2RG Used in Guide Mode Lance Simms Detectors for Astronomy /2/09.
10/26/20151 Observational Astrophysics I Astronomical detectors Kitchin pp
WFIRST 10  m Pixel Pitch Detector Considerations March 10, /10/
CDE CDR, September 14, 2004 Your Position, Your Name 1 GATS AIM Science Team Meeting January 23-24, 2007 CIPS Calibration Review, Aimee Merkel, Bill McClintock.
JWST Calibration Error Budget Jerry Kriss. 15 March 20072/14 JWST Flux & Wavelength Calibration Requirements SR-20: JWST shall be capable of achieving.
Kailash C. Sahu NIRCam: Status Update 1m Cold, space-facing side
Atlas CHEP‘2000 Padova, ITALY February 2000 Implementation of an Object Oriented Track Reconstruction Model into Multiple LHC Experiments.
NIRISS Calibration Working Group Activities NIRISS Science Team Meeting Montréal, 2015 October 20/21 Kevin Volk STScI / HIA.
PVPhotFlux PACS Photometer photometric calibration MPIA PACS Commissioning and PV Phase Plan Review 21 st – 22 nd January 2009, MPE Garching Markus Nielbock.
TIPS - Oct 13, 2005 M. Sirianni Temperature change for ACS CCDs: initial study on scientific performance M. Sirianni, T. Wheeler, C.Cox, M. Mutchler, A.
NICMOS Calibration Challenges in the Ultra Deep Field Rodger Thompson Steward Observatory University of Arizona.
14 January Observational Astronomy SPECTROSCOPIC data reduction Piskunov & Valenti 2002, A&A 385, 1095.
Overview, Spectrometer Products and Processing Philosophy Phil Appleton on Behalf of PACS Team PACS IFU Spectrometer.
11-Jun-04 1 Joseph Hora & the IRAC instrument team Harvard-Smithsonian Center for Astrophysics The Infrared Array Camera (IRAC) on the Spitzer Space Telescope.
Basic Detector Measurements: Photon Transfer Curve, Read Noise, Dark Current, Intrapixel Capacitance, Nonlinearity, Reference Pixels MR – May 19, 2014.
IBB Calibration Update J. Rufus GIST21 Meeting Boulder, CO. 31 st March – 2 nd April 2004 © Imperial College London.
The InGaAs IR Array of Chunghwa Telecom Laboratory Chueh-Jen Lin and Shiang-Yu Wang, Optics and Infrared Laboratory In 2006, Advanced Technology Laboratory.
February 21, 2002TIPS meeting1 "Data contained herein is exempt from ITAR regulations under CFR 125.4(13) -- data approved for public disclosure." TIPS.
CCD Image Processing: Issues & Solutions. CCDs: noise sources dark current –signal from unexposed CCD read noise –uncertainty in counting electrons in.
Selection and Characterization of Interesting Grism Spectra Gerhardt R. Meurer The Johns Hopkins University Gerhardt R. Meurer The Johns Hopkins University.
Non-standard Gains for NICMOS Daniela Calzetti (In lieu of Torsten Boeker) TIPS May 15 th 2003.
Instructor: Mircea Nicolescu Lecture 7
PyRAF/Pipeline Removal of SAA Persistence from NICMOS Data Elizabeth A. Barker Vicki Laidler Eddie Bergeron Anton Koekemoer Elizabeth A. Barker Vicki Laidler.
ACS WFC Flat-Field Changes Temperature change from -77 C to -81 C on July 4, 2006 leads to expected changes for flat fields. Are L-flat measures stable.
1 Notes about eis_prep Alessandro Gardini University of Oslo Oslo, July 9th, 2009.
Cameras For Microscopy Ryan McGorty 26 March 2013.
Electro-optical systems Sensor Resolution
# x pixels Geometry # Detector elements Detector Element Sizes Array Size Detector Element Sizes # Detector elements Pictorial diagram showing detector.
A. Ealet Berkeley, december Spectrograph calibration Determination of specifications Calibration strategy Note in
1 NHSC PACS NHSC/PACS Web Tutorials Running PACS photometer pipelines PACS-403 (for Hipe 13.0) Level 1 to Level 2.5 processing: The Unimap pipeline Prepared.
CCD Calibrations Eliminating noise and other sources of error.
Digital Light Sources First introduced in 2001.
Single Object & Time Series Spectroscopy with JWST NIRCam
Charge Transfer Efficiency of Charge Coupled Device
New static DQ masks for NICMOS
JWST NIRCam Time Series Observations
Detectors of JWST Near IR Instruments
ESAC 2017 JWST Workshop JWST User Documentation Hands on experience
Chapter I, Digital Imaging Fundamentals: Lesson II Capture
Detector Parameters Marco Sirianni - ESA.
NanoBPM Status and Multibunch Mark Slater, Cambridge University
EPIC Calibration & Operations Meeting
Dark Current Experiment Preliminary Design Review
IN5350 – CMOS Image Sensor Design
Presentation transcript:

NIRCam DHAS and Array Characterization John Stansberry UofA NIRCam team

Pipeline/DHAS Implementation NCDHAS Written in C++ for speed (fitsio libraries required) 80 MB per frame/group if running all 10 arrays FITS extensions (slope & uncertainty; intercept & uncertainty; …) Modular design (implemented modules) Reference pixel subtraction Dark (ramp?) subtraction (don’t have satisfactory cal frame yet) “CR” detection/removal Linearity correction, saturation detection Slope & intercept determination Ramp fitting Slope from frame0 Flat-fielding IPC/Hysteresis? At what stage in this flow?

Other Data Processing and Analysis Tools FITS packer for Teledyne data (UA data OK as is) All frames/groups placed into a data cube Much simpler directory structure, I/O Data organization vastly simpler with this format Data Visualization IDL GUI (ncview) based on ATV Pan, zoom, scale Pixel/region values, slope or DN images, ramps/fits Currently limited to single-SCA support Accumulator Converts “raw” data to flight-like multiaccum/grouped data

NCView Latent-decay exposure Functionality: DN images; Pixel ramps To Do: other images, region statistics,…

Array Characterization at UofA UofA array testing facilities Leach controller (4 SCAs 25-frame exposures; 1 SCA 90-frames) Linux workstation, scripting capability, telemetry logging Luppino dewar, 1-4 SCAs or SW FPA, LED sources (diffuse) Performance/Sensitivity Readnoise, dark-current, QE, gain, operability from Teledyne All but QE confirmed post-delivery at UofA “Features” Dark-current settling (problem resolved) Latent images Nonlinear response Cosmic-ray like: RTN / popcorn; snowballs 1st Frame effect Reference pixel ramps

Dark Current “Settling” Early dark measurements at UofA were not very stable Decreasing dark current vs. time Spatial pattern of dark also time dependent

Dark Current “Settling” Latent image pattern High dark-current pattern Effect may be due to incorrect array voltages after data collection system crashes As if the arrays were flooded with charge Decay time-constant much longer than for latent images, though. Also mitigated by double-resets, and adequate settling time after system is brought up Unlikely to be an issue when running w/ ASICs (to be confirmed soon)

Latent Images Latents unlikely to be a big problem Data collected Saturating flood illumination (~200k e-) in 4 frames Latent strength, decay <0.05% @ 100 seconds <~ 0.5% @ 10 seconds To Do Range of brightnesses, temperatures Higher time resolution to measure the decay 0.05% level 200sec data ramps

Nonlinear Response Ramps are nonlinear ~10% effect near saturation Correction strategy Extensive data sets being collected 2nd O polynomial works well Correction verification may only be possible on-orbit Calibration observations over wide range of source brightness No absolutely calibrated sources available for I&T

Popcorn / Random Telegraph Noise Single event per ramp Multiple Events 0.29% 0.095% 1.2% .002% 63 900sec dark exposures, 10.6sec sample time, part C048 <1% of pixels show event in a 1000 second ramp Location of single events depends strongly on output amp. Few 100 DN amplitude

First-Frame Effect NIRCam only issue (?) Fitted function Reference level (from top RP’s) NIRCam only issue (?) Elevated DN in 1st frame after reset Decays w/  ~ 30usec Affects ~20 detector rows @ edge w/ outputs RPs and active pixels Dark-like correction Impact on grouped data Group-1 includes 1st frame NIRCam also gets 1st frame separately

Correction of First-Frame Effect

Reference Pixel Ramps Reference Pixels “integrate” Darks: RP’s show no measurable slope Strong illumination: RP’s show distinct slopes Appears to be coupling in the multiplexer Do the active pixels also show this effect? Testing…

Backup

Summary of Flight Candidate Properties -- : data not yet received from TIS N/A : removed short wavelength tests : Formally misses SCA-level req but top-level sensitivity spec not violated (assuming no other problems)

Flight FPA #1 Candidate Arrangement Illuminated Dark Note that SCAs can only be positioned with their connectors along the top or bottom edges of the FPA. C073 C038 C043 C045

Dark Current “Settling” High dark current condition Low dark current condition

Qualification SW FPA        In the clean room handling jig. In the metrology dewar. In the GL performance dewar. Metrology and performance measurements have been repeated post-vibe: No changes were seen relative to pre-vibe! Qual FPA has been taken to LM ATC for use in FPE check out (w/ ASICs).     After FPE check out, the qual FPA will return to Arizona for use if anomalies or detector issues need investigation. On the way to San Jose (eg. Vibe)

Flight FPA #2 Candidate Arrangement Illuminated Dark C063 C074 C044 C072