P12022: LVAD P OWER T RANSMISSION T EST R IG Erin McNally Pedro Baez Paul Parthemore Kris Stichter.

Slides:



Advertisements
Similar presentations
Sensing and Control.
Advertisements

Instrumentation and Measurements Dr. Mohammad Kilani
Autonomous Control of a Scalextric Slot Car on a User-Defined Track Siddharth Kamath Souma Mondal Dhaval Patel School of Electrical and Computer Engineering.
Chapter 7 Series-Parallel Circuits. Objectives Analyze series-parallel circuits Analyze loaded voltage dividers Analyze ladder networks Analyze a Wheatstone.
Potentiostat Basics I’m Max Yaffe
Multi-Range Analog Ammeter
Module 4: Analog programming blocks. Module Objectives Analyze a control task that uses analog inputs. Connect a potentiometer to LOGO! controller and.
Lecture 9: D/A and A/D Converters
MSD 1 P12453 Detailed Design Review Markus Holzenkamp Robin Leili Cody Anderson 5/17/2015 Detailed Design Review 1.
Unit 4 Sensors and Actuators
Kirsten Hacker Triggering and Measurement Devices for LCLS 10/14/04 1 Triggering and Measurement Devices for the LCLS Undulator.
Multidisciplinary Engineering Senior Design Project 6508 Controls Lab Interface Improvement Preliminary Design Review 11/11/05 Team Members: Michael Abbott,
LFTB Proprietary Information 1 Fuser test bed ™ R I T MSD1 Project Review February 22, 2007 Fuser Test Bed P07501 IE TEAM Justin McMillan – Project Lead.
Vital Signs Monitor UConn BME 4900 Vital Signs Monitor Purpose As the population ages, many people are required by their doctors to take vital signs.
FOLLOWER SENSORS AND ACTUATORS EE 552 INTSTRUCTOR :Dr MOHAN KRISNAN BY MOHAMMED KASHIF IQBAL ANESH BODDAPATTI UNIVERSITY OF DETROIT MERCY.
Data Acquisition Purpose: Support rocket testing, provide a meaningful method to collect and store data Acquired from P7110 Measure sensor outputs  Load.
Multidisciplinary Engineering Senior Design Project 6218 Soft Tissue “Tensile” Tester Preliminary Design Review 2/24/2006 Project Sponsor: Bausch & Lomb.
“Power Supply” Controls Voltage Difference in Voltage is set Output Current is “as requested” by attached device.
Self-Induction Transducers ~ AC Supply v ref Inductance Measuring Circuit x (Measurand) Ferromagnetic Target Object Coil is activated by the supply and.
SENSORS AND TRANSDUCERS
Power and Energy Measurements Chapters: 39 and 42 Juha Kallunki,
Abstract In 2008 President Geoffrey introduced the Live green program which called for environmentally conscious living. In light of this initiative, it.
Autonomous Control of Scalextric Slot Car on User-Defined Track Siddharth Kamath Souma Mondal Dhaval Patel School of Electrical and Computer Engineering.
Automated Feeding Solutions for Dog Owners Preliminary Design Review October 19, 2007 Project Automated Dog Feeder Project Advisor Dr. Hongwei Wu The Canine.
Electrical Measurements: Meters
3D Micromanufacturing Lab. School of Mechatronics Gwangju Institute of Science and Technology 3D Micromanufacturing Lab. School of Mechatronics Gwangju.
EKT314/4 Electronic Instrumentation
PUMP TESTING BY KAUSTUBH V GITAPATHI DIRECTOR VI AUTOMATION (P) LTD, PUNE.
DATA ACQUISITION Today’s Topics Define DAQ and DAQ systems Signals (digital and analogue types) Transducers Signal Conditioning - Importance of grounding.
General Engineering Polytechnic University Laboratory 9: Electrical Filters.
Module 4: Analog programming blocks. Module Objectives Analyze a control task that uses analog inputs. Connect a potentiometer to LOGO! controller and.
BODHPS PROTOTYPE B Testing and Documentation of improved prototype with a record of power output.
Kaitlin Peranski Spencer Wasilewski Kyle Jensen Kyle Lasher Jeremy Berke Chris Caporale.
USB DAQ Product USB DAQ Product Κώστας Γρηγορίου Sales Engineer Ιούνιος 26, 2007.
©2008 Pearson Education, Inc., Upper Saddle River, NJ. All rights reserved. This material is protected under all copyright laws as they currently exist.
Introduction to Engineering Lab 4 – 1 Basic Data Systems & Circuit Prototyping Agenda REVIEW OF LAB 3 RESULTS DEFINE a DATA SYSTEM  MAJOR TYPES  ELEMENTS.
Forging new generations of engineers
COLIN PAYNE-ROGERS JACOB LENNOX DR. BENJAMIN VARELA (GUIDE) COOPER CROUSE-HINDS (SPONSOR) Senior Design P13472 Final Presentation – Change of Resistance.
Chapter 10 Advanced Programming, PLC Interfacing, and Troubleshooting
P16221 – FSAE Shock Dynamometer System Level Design Review September 29, 2015.
Propulsiometer Instrumented Wheelchair Wheel Prepared by: Seri Mustaza (BME) Siti Nor Wahida Fauzi (BME) Ahmad Shahir Ismail (EECE) Hafizul Anwar Raduan.
P12022: LVAD P OWER T RANSMISSION T EST R IG Erin McNally Pedro Baez Paul Parthemore Kris Stichter.
Propulsiometer Instrumented Wheelchair Wheel Prepared by: Seri Mustaza (BME) Siti Nor Wahida Fauzi (BME) Ahmad Shahir Ismail (EECE) Hafizul Anwar Raduan.
Speed Control in DC Motors
Biomechanical Tissue Stimulator Group 1: Matt Brady (BME/EE) Ankeet Choxi (BME) Misha Kotov (CS) Steven Manuel (ME) Adviser: Dr. V. Prasad Shastri.
SYSTEM LEVEL DESIGN REVIEW P16318 Gaseous Mass Flow Rate Controller Luke McKean, Lianna Dicke, Selden Porter, Schuyler Witschi ?
Voltage Divider Circuits Input transducers Input transducers are devices that convert a change in physical conditions (for example, temperature) into a.
ECE 101 Exploring Electrical Engineering Chapter 7 Data Acquisition Herbert G. Mayer, PSU Status 11/30/2015 Derived with permission from PSU Prof. Phillip.
TF Joint Testing Data Acquisition Special Test Equipment Hans Schneider with Robert Marsala (609) Engineering Operations April.
Basic Electronics for Computer Engineering 1 Chapter 3 Ohm’s Law.
Smart, web enabled fridge Marty Lewis. Basic I/O INPUTS Weight/size Sensor Barcode Reader Touch Pad / Touchscreen LCD OUTPUTS SVGA LCD INPUT AND OUTPUT.
Pressure Measurement and Calibration for Process Instrumentation
Chapter 7 Input Modules. Objectives (1 of 2) Explain the differences between positive and negative logic and sinking and sourcing. Describe the available.
Components of Mechatronic Systems AUE 425 Week 2 Kerem ALTUN October 3, 2016.
Intro to USB-6009 DAQ.
USB DAQ Product Introduction
Instrumented Walker Skyler Bullington Tommy Frankenberger Larson Stacy
SCADA for Remote Industrial Plant
P07203 Dynamometry Laboratory Infrastructure
DC MOTOR SPEED CONTROL 1. Introduction
TORQUE MEASURMENT.
Electromagnetic Induction
Systems Design Review : Heart Pump and Circulatory System
MicroLogix Packaged Controllers
Lesson 12: Analog Signal Conditioning
Data Acquisition (DAQ)
ENGR 1 Presentation Thomas Matthews.
LVAD Wireless Power Transfer Test Rig
Electromagnetic Induction
P12022: Wireless Power Transmission Device Test Rig
Presentation transcript:

P12022: LVAD P OWER T RANSMISSION T EST R IG Erin McNally Pedro Baez Paul Parthemore Kris Stichter

T ABLE OF C ONTENTS Background Information Customer Needs Engineering Specifications Preliminary Design Proposed Design GUI Design DAQ Specifications Feasibility Analysis BOM Edgewound Resistor Specifications Interface Diagram Interface Ranges Calibration Test Plan Device Test Plan Risk Assessment Project Plan

B ACKGROUND I NFORMATION About 5 million Americans are currently living with congestive heart failure (CHF) Heart failure contributes to about 287,000 deaths per year Current left ventricular assist devices (LVAD) require a cable connecting to the control unit through a hole in the abdomen A permanent opening through the epidermis is highly vulnerable to infection Current wireless power transmission utilizes induction which tends to cause tissue damage due to excessive heat generation SOLUTION: Transmit power wirelessly through the use of a magnetic coupler Test Rig Scope: Design and build functional test rig to analyze performance of current and future wireless power transmission devices

C USTOMER N EEDS

E NGINEERING S PECIFICATIONS

T EST R IG P RELIMINARY D ESIGN

T EST R IG P ROPOSED D ESIGN

T EST R IG A SSEMBLY MICROMETER LINEAR STAGE LOAD CELL MOTOR CLAMP ASSEMBLY GENERATOR CLAMP ASSEMBLY MOTOR GENERATOR TURNTABLE

G ENERATOR C LAMP A SSEMBLY AIR FITTINGS TORQUE BAR CLAMP PADS SINGLE-ACTION AIR PISTONS

LINEAR STAGE CRANK & LEAD SCREW 1” MICROMETER HEAD SLIDE ASSEMBLY

GUI D ESIGN Contact Force (lb)

USB-2416 F EATURES Measure thermocouples or voltage 32 analog inputs, expandable to bit resolution 1kS/s sampling 8 digital I/O Two counters Up to 4 analog outputs

USB-2416 The USB-2416 series is a multifunction DAQ module designed for highly accurate voltage and/or temperature measurements (configurable from ±0.078V to ±20V). Analog inputs are user-configurable for voltage or temperature input on a per-channel basis When measuring temperature, analog inputs must be configured in differential (DE) mode. All modules also include open thermocouple detection to identify improperly working thermocouples. Two 32 bit counters are included The TTL Level inputs are capable of read/write rates of up to 500Hz with an input frequency of up to 1MHz. Compatible with Labview.

F EASIBILITY A NALYSIS No large forces/temperatures: No finite element analysis required Calculation for generator torque load cell: Want to use 10 lb load cell available determined 0-1 N-m ( in-lb) was acceptable measurement range All other measurement ranges approved by and require no analysis

F EASIBILITY A NALYSIS Calculations for piston force and vertical load cell capacity: 4 4

B ILL OF M ATERIALS

E DGEWOUND R ESISTOR - L OAD ASE – Adjustable resistor Capable of handling high amount of power and high amount of current Choosing capabilities of 240 W with a resistor that varies from 0-8Ω with a 5% tolerance.

Interface Diagram All measurements are going to USB-2416 DAQ unit Voltage and current readings will produce power result NI Labveiw will be used to view all the readings

I NTERFACE R ANGES

C ALIBRATION T EST P LAN

Voltage Verification: Use a DC power supply. Set it at a nominal voltage (5V) and connect leads to DAQ. DAQ should record the applied voltage of power supply (5V). Verify actual voltage with multimeter Current Verification: Use a DC power supply. Set it at a nominal voltage (5V) and connect leads to the DAQ with a resistor in order to create voltage drop. DAQ should record voltage that is different from the applied voltage. Use Ohm’s law to calculate current in Labview Verify actual current with multimeter No calibration necessary for DAQ counters Temperature Verification: Submerge thermocouple in ice water and measure voltage Submerge thermocouple in boiling water and measure voltage Voltage and temperature have a linear relationship and temperature will be proportional to measured voltage Contact Force Verification: Attach calibrated weights to load cell and measure voltage Voltage and force have a linear relationship and force will be proportional to measured voltage Housing Torque Verification: Attach calibrated weights to load cell and measure voltage Voltage and force have a linear relationship and force will be proportional to measured voltage

D EVICE T EST P LAN All results will be viewed in Labview Leads for current and voltage will be directly inserted into DAQ For current acquistion a resistor may be needed Voltage and current at the motor and generator will be used to calculate power Efficiency will be calculated in Labview by: Leads for thermocouples will be directly inserted into DAQ Temperatures are read as voltages, which will be calibrated before testing Leads from force gauges will be directly inserted into DAQ Forces are read as voltages, which will be calibrated before testing Forces will be converted to pressure by multiplying the measured force by the known area of the device Leads for the Hall Effect sensors will be inserted directly into the counter inputs of DAQ Counts will be converted into RPM’s

R ISK A SSESSMENT

P ROJECT P LAN

Q UESTIONS ?