Evaluation of Calibration Accuracy with HPS (HongIk Polarimetric Scatterometer) System for Multi-Bands & Multi-Polarizations Ji-Hwan Hwang*, Soon-Gu Kwon,

Slides:



Advertisements
Similar presentations
GTEM CABLE EMISSION STUDIES MEASUREMENT TECHNOLOGY LIMITED JUNE 29 TH 2010 Dr. Zaid Muhi-Eldeen Al-Daher Dr. Angela Nothofer Prof. Christos Christopoulos.
Advertisements

DESIGNING OF A SMALL WEARABLE CONFORMAL PHASED ARRAY ANTENNA FOR WIRELESS COMMUNICATIONS By Sayan Roy Major Advisor: Dr. Benjamin D. Braaten Dept. of ECE,
RFMTC11 GÄVLE OCTOBER 4–5th 2011 Industrial radar sensor arrays and their applications October 04, 2011 P. Vainikainen, V. Mikhnev, Ye. Maksimovitch, M.-K.
On Estimation of Soil Moisture & Snow Properties with SAR Jiancheng Shi Institute for Computational Earth System Science University of California, Santa.
Jet Propulsion Laboratory California Institute of Technology The NASA/JPL Airborne Synthetic Aperture Radar System (AIRSAR) Yunling Lou Jet Propulsion.
2001 APCO/NENA State Training Conference January 19, 2001.
Heesam Chae, Hoonyol Lee Dept. of Geophysics, Kangwon National University, Chunchon, Kangwon-do, Korea Seong-Jun Cho, No-Wook Park Korea Institude of Geoscience.
1/42 Changkun Park Title Dual mode RF CMOS Power Amplifier with transformer for polar transmitters March. 26, 2007 Changkun Park Wave Embedded Integrated.
Remote Sensing: John Wilkin Active microwave systems (4) Coastal HF Radar IMCS Building Room 214C ext 251 Dunes of sand.
Remote Sensing: John Wilkin Active microwave systems Coastal HF Radar IMCS Building Room 214C ph: Dunes of sand and seaweed,
Physics-based Modelling of Foliage-Camoulaged Targets
A Multilayered Broadband Reflect-Array Manuel Romero.
July 2015 doc.: IEEE /XXXXr0 July 2015
Offset Quadruple-Ridge Orthomode Transducer, Mode Splitter/Combiner
Initial Results on the Cross- Calibration of QuikSCAT and Oceansat-2 Scatterometers David G. Long Department of Electrical and Computer Engineering Brigham.
1 Antenna design and optimisation Test-bed of mechanical tilt CSEM.
On Estimation of Surface Soil Moisture from SAR Jiancheng Shi Institute for Computational Earth System Science University of California, Santa Barbara.
IGARSS’11 Compact Polarimetry Potentials My-Linh Truong-Loï, Jet Propulsion Laboratory / California Institue of Technology Eric Pottier, IETR, UMR CNRS.
Fundamental Antenna Parameters
Phased Array Feeds John O’Sullivan SKANZ 2012 CSIRO Astronomy and Space Science,
SRANT Lab., Korea Maritime University A Study on Improved Algorithm for MIMO Antenna Measurement Thanh-Ngon Tran Supervisor: Professor Kyeong-Sik Min SRANT.
1 of 22 Glaciers and Ice Sheets Interferometric Radar (GISIR) Center for Remote Sensing of Ice Sheets, University of Kansas, Lawrence, KS
DOCUMENT OVERVIEW Title: Fully Polarimetric Airborne SAR and ERS SAR Observations of Snow: Implications For Selection of ENVISAT ASAR Modes Journal: International.
- Microwave Remote Sensing Group IGARSS 2011, July 23-29, Vancouver, Canada 1 M. Brogioni 1, S. Pettinato 1, E. Santi 1, S. Paloscia 1, P. Pampaloni 1,
Maximum Gain Amplifiers For the two-port network shown below, It is well known that maximum power transfer from the source to the transistor occurs when:
Measurement of Integrated PA-to-LNA Isolation on Si CMOS Chip Ryo Minami , JeeYoung Hong , Kenichi Okada , and Akira Matsuzawa Tokyo Institute of Technology,
William Crosson, Ashutosh Limaye, Charles Laymon National Space Science and Technology Center Huntsville, Alabama, USA Soil Moisture Retrievals Using C-
Active Microwave Physics and Basics 1 Simon Yueh JPL, Pasadena, CA August 14, 2014.
1 EVLA System Commissioning Results EVLA Advisory Committee Meeting, March 19-20, 2009 Rick Perley EVLA Project Scientist.
SWOT Near Nadir Ka-band SAR Interferometry: SWOT Airborne Experiment Xiaoqing Wu, JPL, California Institute of Technology, USA Scott Hensley, JPL, California.
KIGAMKIGAM 지반변형 모니터링을 위한 GROUND-BASED SAR 개발 지반변형 모니터링을 위한 GROUND-BASED SAR 개발 한국지구시스템공학회 조성준 (1), 이훈열 (2), 성낙훈 (1), 김정호 (1) (1)한국지질자원연구원.
Microwave Engineering, 3rd Edition by David M. Pozar Copyright © 2004 John Wiley & Sons Figure 13.1 (p. 634) Photograph of various millimeter wave antennas.
Synthetic Aperture Radar Specular or Bragg Scatter? OC3522Summer 2001 OC Remote Sensing of the Atmosphere and Ocean - Summer 2001.
Institute of Atmospheric Physics Fast Calibration of Weather Radar Systems for Multi Polarization Radar Measurements Jens Reimann, Martin Hagen DLR-Institute.
University of Kansas 2004 ITTC Summer Lecture Series Network Analyzer Operation John Paden.
TropiSCAT : A MULTI-FREQUENCY POLINSAR DATA CAMPAIGN OF ACQUISITION FOR VEGETATION CHARACTERIZATION Clément ALBINET – Office National d’Etudes et de Recherches.
Design Features of a Boresighted GPM Core Radiometer Christopher S. Ruf Dept. of Atmospheric, Oceanic & Space Sciences University of Michigan, Ann Arbor,
1 Practical considerations on train antenna design CSEM.
On Estimation of Soil Moisture with SAR Jiancheng Shi ICESS University of California, Santa Barbara.
Distributed Adaptive Control and Metrology for Large Radar Apertures PI: James Lux Co-Is: Adam Freedman, John Huang, Andy Kissil, Kouji Nishimoto, Farinaz.
P.W. Gorham et al.. TEST BEAM A SLAC Time relative to beam entry Antenna V/V rms Time relative to beam entry Antenna V/V rms close to shower maximumshower.
Chapter 3 Antenna Types Part 1.
SEA ICE CHARACTERISTICS IN THE SOUTHERN REGION OF OKHOTSK SEA OBSERVED BY X- AND L- BAND SAR Hiroyuki Wakabayashi (Nihon university) Shoji Sakai (Nihon.
0 Riparian Zone Health Project Agriculture and Agri-Food Canada Grant S. Wiseman, BS.c, MSc. World Congress of Agroforestry Nairobi, Kenya August 23-28,
TropiSCAT : A MULTI-FREQUENCY POLINSAR DATA CAMPAIGN OF ACQUISITION FOR VEGETATION CHARACTERIZATION Clément ALBINET – Office National d’Etudes et de Recherches.
Page 1ENVISAT Cal/Val Workshop – ESRIN – 9/13 December 2002 Antenna Elevation Pattern Estimation from Rain Forest Data M. Zink ENVISAT Programme ESA-ESTEC.
Chalmers University of Technology Site-Dependent Electromagnetic Effects in High-Accuracy Applications of GNSS Jan Johansson and Tong Ning Chalmers University.
RADAR ANTENNA. Functions of Radar Antenna Transducer. Concentrates the radiated energy in one direction (Gain). Collects echo energy scattered back to.
CLPX Workshop May 28-29, 2003 Boulder, Colorado Ground-based Radar Measurements of LSOS Snowpack Gilles CASTRES SAINT-MARTIN Kamal SARABANDI Radiation.
WP120 External Calibration of Spaceborne Microwave Remote Sensing System Sensors Objective:Evaluation of external calibration needs for a variety of microwave.
Detection of Wind Speed and Sea Ice Motion in the Marginal Ice Zone from RADARSAT-2 Images Alexander S. Komarov 1, Vladimir Zabeline 2, and David G. Barber.
Midterm Review 28-29/05/2015 Progress on wire-based accelerating structure alignment Natalia Galindo Munoz RF-structure development meeting 13/04/2016.
KTM KTM Technology Co, Ltd. Over-the-Air Performance Test System for Mobile Station ㈜케이티엠테크놀로지 KTM.
Radio Noise Measurement and Related Standards
Spring '17 EECS Intro to Radar Systems
Ultra-low Power Components
Active Microwave Remote Sensing
X-band high-power variable RF splitter
Small-Scale Characteristics of 45 GHz Based on Channel Measurement
Estimationg rice growth parameters using X-band scatterometer data
Monitoring of Rice Growth Using Polarimetric Scatterometer System
Radar backscattering measurements of paddy rice field using L, C and X-band polarimetric scatterometer ISRS 2007.
(L, C and X) and Full-polarization
Large-Scale Characteristics of 45 GHz Based on Channel Measurement
Cross-Polarized SAR: A New Potential Technique for Hurricanes
Large-Scale Characteristics of 45 GHz Based on Channel Measurement
이훈열, 조성준, 성낙훈 강원대학교 지구물리학과 한국지질자원연구원 지반안전연구부
ANTENNA THEORY by Constantine A. Balanis Chapter 2.13 –
Paper review Yun-tae Park Antennas & RF Devices Lab.
Electronically Steered Antennas
Presentation transcript:

Evaluation of Calibration Accuracy with HPS (HongIk Polarimetric Scatterometer) System for Multi-Bands & Multi-Polarizations Ji-Hwan Hwang*, Soon-Gu Kwon, and Yisok Oh Electronic Information and Communication Eng., HongIk University Contents 1) Objectives 2) Configuration of HPS system 3) Innovative antenna system for L-band 4) System calibration & accuracy evaluation 5) concluding remarks 1

Objectives For a comparison study on earth observation with satellite SAR system at various frequency bands, requirements of multi-bands / polarizations ground based scatterometer continuously are increasing. the existing HPS(Hongik Polarimetric Scatterometer) system basically support L-,C-,X-bands and full-polarizations (vv-, vh-, hv-, hh-pol.), however, those are separated system. this study shows configurations of 1) integrated system for multi-bands with single platform and evaluates an accuracy of 2) system calibration in the field experiments. 2 IGARSS 2011

3 Configuration of HPS system 1) Boom structure (8m) : movable platform 2) Head part : it’s consist of sensor (OMT+Ant.) and incident angle control 3) Sub-circuit : this circuit achieves two functions of frequency converting and switching for full-polarization 4) DAQ, Graphic User Interface : HPS is basically network analyzer based system, Agilent 8753E and controlled by GUI [1] P. O’Neill, et al, “Survey of L-Band Tower and Airborne Sensor System Relevant to Upcoming Soil Moisture Missions,” IEEE Newsletter Geosci. Remote Sensing, Jun

4 To implement the motion control(θ,Ф), head part is composed of 3 step motors and inclinometer sensor. Incident angle (θ) : tolerance 0.2° IGARSS 2011 Configuration : Head Part (2) Inclinometer sensor (2-axis) (1) Step motors (3ea) [2] J.-H. Hwang, S.-M. Park, S.-G. Kwon, Y. Oh, “Study on the calibration of a full-polarimetric scatterometer system at X- band (in Korean)”, KIEES, Apr

5 Switching circuit offers full-polarimetric signal without mode change of network analyzer (Agilent 8753E) and switch the path for each bands Frequency conversion and amplifier circuit only for X-band minimize signal distortion and path loss through 7m RF cable : (9.65GHz to 1.25GHz, gain 32dB p1dB 20dBm) IGARSS 2011 Configuration : sub-circuit RF-cable 7m Pol. indicator Tx-path Rx-path

6 IGARSS 2011 GUI software controls whole measurement system: ex) inc. angle, time gating, Tx power level, automatic meas., system cal. Configuration : GUI & DAQ File header Full-pol. Measurement data Incidence angle

7 IGARSS 2011 Innovative Ant. System for L-band (type 1) the existing ant. system (horn ant. + OMT) for L-band is too bulky to be installed in HPS platform. So, we suggested two types of compact OMT. [3] J. -H. Hwang, S.G. Kwon, Y. Oh, “orthomode transducer using trapezoidal waveguide”, Patent in Korea, (in progress). Waveguide taper waveguide T-junction V-pol. H-pol. Common mode port Waveguide taper V-pol. H-pol. Conducting post Total length = 75cm, Reduced total size to about 56% Type 1 OMT is minimized by newly designed compact T-junction

8 IGARSS 2011 Innovative Ant. System for L-band (type 2) Total length of new OMT is about 86cm (commercial OMT 1.35m) It achieved reducing the OMT size to about 62% and also keeping the comparable performance with the same class OMT structure Stepped-horn antenna (length: 300mm, 1.26 λ 0 aperture: 450 × 450mm 2 ) Proposed new OMT (length: 560mm, 2.35λ 0 ) [4] J. -H. Hwang, Y. Oh, “Compact OMT Using Single-Ridged Triangular Waveguide”, IEEE MWCL, [5] J. -H. Hwang, S.G. Kwon, Y. Oh, “orthomode transducer using waveguide with 4-splitted triangular cross section”, Patent in Korea, (in progress).

9 System calibration (Single Target Cal. Tech.) IGARSS 2011 [5] K. Sarabandi, and F. T. Ulaby, “A convenient technique for polarimetric calibration of single-antenna radar systems,” IEEE Trans. Geosci. Remote Sensing, Nov IGARSS 2011 HPS system was calibrated using STCT at each frequency bands. to calibrate HPS system, measured data of ref. and test targets are needed, and we can calculate the calibrated scattering matrix of test target. s 0 : theoretical [S 0 ] of ref. target (sphere) m 0 : measured [M 0 ] of ref. target (sphere) m u : measured [M u ] of test target (C.R.) s pg : calibrated [S] of test target (C.R.) Mie exact solution 2DTST (2D target scanning technique) This method offers ‘well-aligned’ data

10 IGARSS 2011 System calibration (2D Target Scanning Tech.) 2DTST: this technique can measure full-pol. freq. responses of ref. / test targets and graphically choose the ‘well-aligned’ center data. [4] J. -H. Hwang, S. -M. Park, Y. Oh, “Calibration Accuracy Enhancement in the Field Experiment with a Ground-Based Scatterometer”, IGARSS 2010, Aug Concept view of gird system for 2DTST Max point (-1,1) ~ boresight Scan resolution ~1˚

IGARSS 2011 System calibration (multi-bands/full-pol.) 11 These results are calibrated Full-pol. freq. responses using STCT and 2DTST to evaluate calibration accuracy, conducting sphere of 30cm diameter and 30/45cm TCR were used as REF. and test target, respectively freq. [GHz] X-Band freq. [GHz] C-Band freq. [GHz] RCS,  p q [dBsm] L-Band theory un-cal. cal. s vv s vh s hv s hh After calibration, effective isolation levels improve more than about 10dB

freq. [GHz] freq. [GHz] freq. [GHz] Rasiduals [dB] X-BandC-BandL-Band IGARSS Cal. resid. un-cal. resid. Cal. accuracy ~ 0.3dB ~ 0.4dB ~ 0.3dB Calibration accuracy can be defined to RMS value of the norm of residuals, which is a degree of similarity between two data arrays. : RMS norm of residuals Evaluation of Cal. accuracy

13 IGARSS 2011 Evaluation of Cal. accuracy These results show the spatial changes of calibration accuracy depending on the degree of mis-alignment between antenna and test target. we can assign ‘Reliability zone’, which is ‘well-aligned’ region to guarantee the calibration accuracy of 0.5dB in field experiments. *Note: It depends on meas. antenna radiation pattern: HPBW (29°/35°, 25°/29°, 12°/13°), E-/H-. Phase error does not exceed about 7˚ in all frequency bands.

14 IGARSS 2011 HPS system for multi-bands & multi-polarizations integrated to single-platform and, especially, the newly designed antenna + OMT system for L-band is applied. To calibrate scatterometer system, STCT and automatic 2DTST were used, and these results agreed well with theoretical RCS. ‘Reliability Zone’, to guarantee 0.5dB calibration accuracy, are 6.5˚, 5˚, and 3˚ in L-,C-,X-bands, respectively. This ground-based HPS system will be continuously used for comparison study of satellite SAR system as a test-bed. Concluding remarks Thanks, do you have any questions??

15 IGARSS 2011 Appendix 1. (off-center error rate) to verify the off-center error caused by mis-alignment, we measured surroundings from the center of ref. target. we assume that the well-aligned center data, maximum position between antenna and target, have highest accuracy and reliability. where, ‘corr.’ is correlation coefficient of centered and off-centered meas. data arrays of ref. target.

16 IGARSS 2011 Appendix 2. : Backsacttering coef.(σ˚) in tidal flat + pattern cal. [M 0 ] C-band, Oyster field Mud area C-band: oyster field X-band: mud area X-band, Oyster field Mud area