DEVICE DRIVER SAMPLES.

Slides:



Advertisements
Similar presentations
AIS Advanced Identification System VHF Transponder Target Name – Official Number Speed Range CPA – Closest Point of approach TCPA – Time of CPA.
Advertisements

SINGLE BEAM EDITING HYPACK
Patch Testing HYPACK 2013.
Importing Data into IX1D v 3 – A Tutorial © 2006 Interpex Limited All rights reserved Version 1.0.
HYSWEEP® HARDWARE.
EXCAVATORS HYPACK 2013.
SEABED ID HYPACK Seabed ID Basics  Bottom Roughness:  E1 = f(T1,T2)  Comparison of the length of time of the returns between the 1st and 2nd.
CUTTER SUCTION DREDGES
HYSWEEP® SURVEY HYPACK 2013.
HYPACK MULTIBEAM COURSE
Note if in doubt click the “Help” button
TOWFISH DRIVER.
HYPACK® Multibeam Training Seminar
Anchor Handling Changes. Basic Idea Barge with HYPACK SURVEY Tug 1 Tug 2 Tug 3 Home Office GPS & HDG WEBIF Or SURVEYVIEWER All vessels can see each other.
RIG MOVES. Step 1: Boat Shape Editor Create your boat shape. The Boat Origin Reference Point is at the X=0, Y=0 point. Set 1 or 2 anchor points. – One.
DEMONSTRATION FOR SIGMA DATA ACQUISITION MODULES Tempatron Ltd Data Measurements Division Darwin Close Reading RG2 0TB UK T : +44 (0) F :
Remote Accessing Your Home Computer Using VNC and a Dynamic DNS Name.
TrendReader Standard 2 This generation of TrendReader Standard software utilizes the more familiar Windows format (“tree”) views of functions and file.
Configuring the MagicInfo Pro Display
December 10th Inservice Presenter: Linda Lopresti 9-10 English Department (K112) Contact Info: twitter:
SURVEY VIEWER HYPACK Sending SURVEY Windows Across the Network to Non-HYPACK Computers. HYPACK Computer Non-HYPACK Computer Running SURVEY VIEWER.
Ircon ® ScanIR ® 3 Linescanner How to work with Snapshots? Confidential Rev. A 07/2013.
Dynatest LWD Program - Sections
What’s New?. Web Map Servers: Re-projection Web maps are now automatically converted to your Project geodesy! AVI.
HYPACK HARDWARE CONFIGURATION
Hydrographic Survey Software for Windows.  Eye4Software B.V., based in the Netherlands was founded in  More then 15 years of experience in Hydrography.
2005 HYPACK Training Seminar 1 CASE 14.a. Utilities PROJECT: NONE An Overview of Utility Program.
Hydrographic Survey Software for Windows.  Eye4Software B.V., based in the Netherlands was founded in  More then 15 years of experience in Hydrography.
SYNCHRONIZING THE COMPUTER CLOCK. Who Should Synchronize? Recommended only if you have another computer system delivering datagrams with UTC time stamps.Recommended.
HYSWEEP® PATCH TESTING.
HYPACK MAX Training Seminar Advanced Survey Topics Multivessel & Specialty Drivers Demonstrations of operating with more than one vessel & specialty.
TIME TAGGING. HYPACK ® Timing Basics  The internal clock on your computer is a lousy clock.  HYPACK SURVEY and DREDGEPACK ® use a proprietary clock.
JDS5 Training Guide. On Start Up you will see this screen click the OK button Click OK.
Hydrographic Survey Software for Windows
WATER LEVEL OPTIONS. Water Level Corrections Water Level Above Chart Datum = Negative Tide Correction! In Depth Mode:  Chart Sounding =  Measured Sounding.
SINGLE BEAM EDITING HYPACK
MAGNETOMETERS IN HYPACK® Data Collection & Data Processing.
HYPACK SHELL HYPACK Shell Features: Multiple maps, views and floating tool bars.
Processing Single Beam Data
ON-LINE CONTROLS. HYPACK SURVEY Key Commands: Key combo:Action Control – SStart Line Control – EEnd Line Control – WSwitch Line Direction Control – IIncrement.
HYPACK PROJECTS HYPACK Projects What’s in a Project  ‘ A Project contains all of the information about a specific survey in a separate folder.
DREDGEPACK® Basics.
SIDE SCAN HARDWARE CONFIGURATION
Important! Be sure to connect the communication cable to your computer before opening the Aqua4Plus Lite software. (Click to continue)
HYSWEEP® SURVEY.
CRANES.
HYSWEEP® HARDWARE.
ENC EDITOR.
RTK TIDES.
HYSWEEP ® HARDWARE. HYSWEEP ® Survey Configuring a Multibeam System Multibeam sonar GPS (via HYPACK hardware) Motion sensor Heading sensor Dynamic Draft.
HYSWEEP ® HARDWARE. HYSWEEP ® Survey Configuring a Multibeam System Multibeam sonar GPS (via HYPACK hardware) Motion sensor Heading sensor Dynamic Draft.
EXCAVATORS. Excavator.dll : General Settings Contains:  Excavator Dimensions  System Override Values  Useful when a sensor fails  Sensor Adjustments.
SEABED ID. Seabed ID Basics  Bottom Roughness:  E1 = f(T1,T2)  Comparison of the length of time of the returns between the 1st and 2nd echo.  The.
HYPACK HARDWARE CONFIGURATION. HYPACK ® HARDWARE: Combined HYPACK HARDWARE, HYSWEEP HARDWARE & SIDE SCAN HARDWARE are now combined in a single HYPACK.
Patch Testing. HYSWEEP ® Calibration of a Multibeam System Patch Testing Single and Dual Head Multibeam Systems. Patch Testing Single and Dual Head Multibeam.
ON-LINE CONTROLS. HYPACK SURVEY Key Commands: Key combo:Action Control – SStart Line Control – EEnd Line Control – WSwitch Line Direction Control – IIncrement.
SIDE SCAN HARDWARE CONFIGURATION HYPACK Connection Block Diagram GPS, single beam and tide data go into HYPACK ® SURVEY. Sidescan (with optional.
2003 HYPACK MAX Training Seminar1 Sample ADCP 112 – Computing Flow Quantities in ADCP Profile The ADCP Profile program displays color- coded flow data.
VESSEL SETTINGS. Vessel Functions Each mobile can have separate settings for each Area Map. Main Vessel (designation) Display Shape (toggle) Select Shape.
SURVEY VIEWER Note: SURVEY VIEWER functions are now available from the Remote Viewing that is built into HYPACK SURVEY. SURVEY VIEWER still works, but.
MATRIX FILES IN SURVEY. Sample of AutoMTX Display in SURVEY. The Auto Matrix (AutoMTX) feature in HYPACK only works with multibeam systems. Based on your.
TARGETS IN SURVEY HYPACK 2016.
DEVICE DRIVER SAMPLES. How Many ? How to add an update?  Currently HYPACK has between Device Drivers  There are 192 in the \HYPACK 2015\Devices.
EXCAVATORS.
CUTTER SUCTION DREDGES. Cutter Suction Configuration Cutter Suction Configuration ` Water Level Chart Datum Channel Design Depth Channel Design Overdepth.
SYNCHRONIZING THE COMPUTER CLOCK
SUB BOTTOM DATA 1.
WATER LEVEL OPTIONS. Water Level Corrections Water Level Corrections Water Level Above Chart Datum = Negative Tide Correction! In Depth Mode:  Chart.
MATRIX FILES IN SURVEY.
MAGNETOMETERS IN HYPACK® Data Collection & Data Processing.
Presentation transcript:

DEVICE DRIVER SAMPLES

How Many ? How to add an update? Currently HYPACK has between 300 - 400 Device Drivers There are 192 in the \HYPACK 2015\Devices folder. There are 143 more in the \HYPACK 2015\Devices\Custom folder. In addition, HYSWEEP has over 70 devices built in. Constantly modifying and maintaining them and providing updates. To add a new device driver: Copy the DLL to the \HYPACK 2015\Devices folder. In HARDWARE, click the “Rescan Driver List” button (highlighted in red).

ANCHORMANAGER.DLL Allows you to position each anchor: On the main vessel (Barge) On any secondary mobile (Tugs) If Tugs have anchor positions, you can select which anchor positions (e.g. Fore and Aft) If Tugs do not have anchor positions, the anchor is transferred to the Boat Origin for the mobile. At a user-defined target. On the bottom. Anchor Management routines are now ‘Built-In’ to HYPACK SURVEY. They can be accessed from the Vessels menu item.

ADCP.DLL Collection for ADCPs (RD INSTRUMENTS and SONTEK) is now done with the ADCP.DLL.

AIS.DLL: Automatic Identification System Transponders Generates mobile targets in SURVEY to denote vessel positions. AISTIDE.DLL reads tide corrections broadcast over AIS. Coming soon: Virtual Bouys!

DRAFTTABLE.DLL: Dynamic Draft Correction versus Speed Allows for ‘Single’ or ‘Shallow Water and Deep Water’ curves. Interpolates when between the Shallow and Deep Depth Limits.

GENDEVALL.DLL: Reading Devices with Fixed Length Data Fields This driver can be used to read a device that does not have a HYPACK driver. The only restriction is that the data format has to have a single, fixed format message. The length can’t change.

GENDEVPARSE.DLL Reading Devices with Comma, Space, or Tab separated Data Fields Driver Test Raw Data from Device Driver Configuration This driver can be used to read a device that does not have a HYPACK driver. It parses different fields, either comma, space of tab delimited. It can also read fixed-format datagrams.

GENOFFSET.DLL Placing a ‘mobile’ at a fixed location on another ‘mobile’ Mobile ID = Mobile # of Main Barge or Vessel (usually = 0) This driver is used to position another mobile at a fixed offset from the primary mobile. For example, a crane that is fixed in position on the primary mobile, but can rotate independently.

GPS.DLL: Used to process NMEA Sentences from most GPS systems. See the HARDWARE – BASICS presentation for details….

NTRIP.DLL: Designed to pass NTRIP corrections to GPS. Shares same serial port as GPS.DLL. NTRIP Ver. 2 Compatible.

LptEvt.DLL Generating Event Marks via a Contact Closure BNC Out (contact closure) LptEvt.DLL Setup: Generate contact closure at event marks. Generate contact closure when XTE is exceeded. USB In Connection to PC: USB: LptEvt.DLL

MAGNET.DLL AVI DF 1000 (Serial) Geometrics 881/882/G-858 Map Mapper/G-882TVG Insight Marine (881 Dual) IXSEA Magis J W Fisher Proton 4 Marine Magnetics Seaspy/Seaquest Scintrex Envigrad Seaquest SMM II UC Mag GEM Systems GSM-19 Quantro Sensing Magnetometer AVI

PLAYBACK.DLL: Replay RAW Data Files in SURVEY AVI ‘Connection’ should always be either a single RAW data file or a Catalog (*.LOG) of RAW data files. Slow down the ‘Update Rate’ under Advanced.

SEABEDID.DLL For Use with Roxann and EchoPlus Seabed ID Systems Perform ‘Ground Truthing’ and create Seabed ID Square (*.SIX) in SEABED STATISTICS program. In real time, E1 and E2 info is plotted on Seabed ID Square and in Profile view. Data can be re-mapped to new *.SIX in Post-Processing

SIM32.DLL Positioning Echosounder SIM33 Differences: Speed Up/Down Turn Left/Right Echosounder Single or Multiple Transducer Generates Depths based on Sine Curve SIM33 Differences: Speed and heading changes are continuously applied until ‘Steady’ or ‘Stop’ buttons are hit.

TIDEDR.DLL Read Predicted Tide Files (*.TID) into Survey Additional generic tide gauge setup. Switch between telemetry and tide file real time. Now provides a real time graph. User can adjust ‘on-the-fly’ Tidefile2.dll now being phased out. When reading a *.TID file, set the update rate for the device to one second or greater.

WebIF.DLL Has it’s own presentation under ‘Survey’. Used to view the SURVEY program (Area Map and Data) from an Intranet connection. Add WebIF.DLL to your HARDWARE configuration. It does not require any connection information. On another computer on the Intranet, you can then view the SURVEY or DREDGEPACK programs by entering the Web IP address (or computer name) with port 8080 (now configurable). http://Pats-Fujitsu:8080 http://265.1.13.254:8080 http://localhost:8080 (to view on same computer) Remote viewing is now built into HYPACK SURVEY.

YSI6600.DLL Environmental Sensor YSI6600 (Sonde) can be configured with different sensor packages. Setup: Provide a name for each sensor, based on its channel. SURVEY: Driver displays text values and can display a graph for all sensors.

CUTTER.DLL Enhanced display of cutter suction dredge in DREDGEPACK.

Excavator Driver Multiple Inclinometers Directional GPS Position Heading

EXCAVATOR.DLL: Used for Excavator Systems

INCLINOMETER.DLL Inclinometer for Cutter Suction Dredges and Cranes Used for RVG, Ocala, A2TS, Rieker H4, Damen, AGI MD900T, Dickerson, eTrac, and WMI inclinometers. Measures the vertical angle (from the horizon).