Training Manual: KI9600A Series Pocket Power Meters Level 1 June 2011.

Slides:



Advertisements
Similar presentations
User Guide KI 734x Series Two way Loss & ORL Tester
Advertisements

SECTION 11 LEVEL B SUIT OUT. SECTION 12 AIR MONITORING.
DP-IR Detecto-Pak Infrared
KI 2600 Series Power Meters Feb 2012.
(PLEASE SWITCH TO THE SLIDE SHOW MODE)
GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel.
CAN HELP iPC1550KP Keypad and Reprogramming Overview.
AC-SSC-1 Installation and operation manual
LogTag Training January 2015
Training Manual: KI7600 Series Power Meters Level 1, V2.0 September 2008.
Portable Radio Operations
Training for Radiation Pagers Training for Radiation Pagers Berkeley Nucleonics Corporation 2955 Kerner Blvd. San Rafael, CA
ESI Phone System Training Adcom/Valentine Systems
 Description of PressurePro System  Identify system components  Display and Operational Modes  Sensor alerts  Checking of tire pressures  Manual.
Unit Test Calibration Training
May 2007 North Zone – Communications Motorola W9 Control Head North Zone Communications Committee.
Copyright 2008 Kenneth M. Chipps Ph.D. How to Terminate a Corning Unicam Connector Last Update
BE-2110i VF/WIDEBAND TRANSMISSION TEST SET OPERATING OVERVIEW Slide 1 of 9.
© 2008 Masimo Corporation Includes a review on Carbon Monoxide Poisoning For Emergency Responders V.8 1 May 2011 Monitoring CO Poisoning with the Rad-57.
Familiarization and Operation
The PHENIX/EMCal(PbSc)/BB/TOF Laser User Instructions Sean Stoll (rev. 12/8/03)
SUPER PASS II Personal Alert Safety System Charles Montgomery Fire Chief Course Developed by Lt. Ricky Phillips Sam Johnson Assistant Chief.
Clean Air Box Usage & Care CABs RAMs CO Monitors.
DIGITAL LIGHT METER Dr. Lim Jac Fang Occupational Health Doctor Department of Health, Sabah 1994 CT Lutron LX-105 LIGHT METER.
Kaleida Health Point of Care Glucometer Testing 2011
Advanced Tool Management Information Module Advanced Tool Management Information Module.
GLOBE Protocols. Steps: 1. Look in ALL directions of the sky for any clouds. *avoid sun* 2. Identify types of clouds using GLOBE cloud chart and Observing.
TESTING MULTIMODE FIBER
AccuMax Multi-Point Injection Mechanics
1 Training Manual: KI7400 & 7800 Series Sources Level 1, V2.0 August 2008.
Blower Door Quickie Set-Up Guide.
May 2007 North Zone – Communications Bendix King EPH and GPH Portable Radios North Zone Communications Committee.
Series Operational Training. 2 Water Tank Water Pump Multiple Discharges 2000 Series Line Strainer Foam Tank Electronic Direct Injection Proportioner.
© Fluke NetworksVisiFault L&L June 2004 VisiFault Visual Fault Locator (VFL) New tool traces fiber, verifies continuity and polarity, helps find breaks.
Gates Professional Development Series Gates Sonic Tension Meter 507C NEW! Measures Tension in BothV-BeltsAnd Synchronous Belts.
North Zone – Communications
Nokia Bluetooth Headset BH-108 for Contact Centers
Self Guided Tour of TagMate™QC Display Tag DATA Tag Data: PRINT TagMate™QC SETUP Display STATS Tags: START and READ SEND All Data to PC Additional Capabilities.
© 2008 Masimo Corporation RAD-57 EMS Carry Case Lightweight: 13 oz. Small: 6.2” x 3.0” x 1.4” Portable: operates on 4 “AA” batteries Supplied with high-visibility,
Model 1621M Trainer’s Guide. General Overview Model 1621M is a Geiger Meuller based Personal Radiation Detector (PRD) Complies with ANSI Used for.
Scout Pro Training Introducing the Scout Pro Portable Balance: 7 Models From 200g x 0.01g to 6000g x 1g 5 Application Modes Optional USB or RS232 Interface.
GCS 300 System Operation Application – Level 1.
MSA Five Star 4-Gas Monitor Air Monitoring Instrumentation.
© 2007 Multigas Detector Reliability in a small package.
O ptical R eturn L oss testing using KI 7340 series Loss Tester Kingfisher International PTY LTD V
BMC Medical Co., Ltd. Nov Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP.
MODEL : EDF-102 SERIES 1. APPLICATION The EDF-102 thermostat is designed to provide temperature control of heating or cooling systems in villas, hotels.
BMC Medical Co., Ltd. Nov Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP.
To complete installation on electronic models run one wash cycle then click the DIP switch setting no.4 to the on position DIP switch settings.
Service Section Technical Training December 2005.
InnoSys Park Brake Tool Master Control Panel Screens Revision A, 12Dec /12/20071.
Spring Hill Assembly1 InnoSys Park Brake Tool Master Control Panel Screens 1 3-Mar-2008.
BMC Medical Co., Ltd. Nov Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP.
Zones 1 to 8 Siren Keypad Power 12V Data and clock By default: Zone 1 Entry Exit 2 Follower 3 Instant 4 Instant 5 Instant 6 Instant 7 Instant 8 Panic.
F-900 PORTABLE ETHYLENE ANALYZER INSTRUMENT TRAINING
All Freezer Advance. When the Freezer is first supplied with power or if a power outage occurs, the display will indicate this by flashing the temperature.
USER GUIDE TEMPERATURE CONTROLLER TR-2006 Hot runner temperature controller ShenZhen TanRex Electronic Co.ltd.
2015 Touch Screen Voting Device Training For AVPM and Non-AVPM TSX Counties Presented by: Derrick Cooper Elections Systems Training Specialist Mississippi.
Quick Start Guide for Flex Flow Pump
CA05FS Owner’s Manual Fuel Cell Technology Breath Alcohol Tester.
Analog Room Command Module
NSA-7000 Stylish flush mount Network Sensors
User Manual 1 2a 2b A. Introduction This product is a battery-powered, true-rms, auto-ranging digital multimeter.
G450 and G460 battery pack maintenance
PHASE IDENTIFICATION UNIT (PIU)
Digital Chart Recorder Operation
724 Temperature Calibrator
System 57 Gas Control System
Dräger X-am 5000 / X-am 5600 VIDEO BASIC TRAINING
Presentation transcript:

Training Manual: KI9600A Series Pocket Power Meters Level 1 June 2011

2 Course Contents 1.General Features 2.Models 3.Detector Types 4.Keypad 5.Instrument Care 6.Operation 7.Operating Modes 8.Log / Linear display 9.Special Features

3 1. General Features  Battery life – 300 hours  Calibration at multiple wavelengths  Ruggedised, water & dust resistant  3 year re-calibration interval  3 year warranty – extendable to 5 or 7 years  Special Features: ‘Multi-fiber ID’, SlowMode and TamperLock  Entry skill level  Fits in shirt pocket  Test tone detection  Industry standard interchangeable connectors – Including SFF

4 There are two model styles: A.KI9600A: for popular connector types – the most popular. B.KI9600-XL: fitted with a wide area detector - plastic fibre, MT-RJ, ribbon and specialty fibre applications up to 3 mm core diameter. 2. Models

5 3. Detector Types Several Detector types are available to suit your application. Choose a detector style to suit your power and wavelength requirements. H series High power – CATV, DWDM Power level configurations of up to +24 dBm Filtered InGaAs Si Wide area detector configuration - LAN at 850nm, POF Power levels of up to 0 dBm Will not work at 1300 nm Available XL series meters only InGaAs Telco & LAN Power Levels of up to +5 dBm Most accurate detector type at Telco wavelengths Ge LAN at 850 & 1300nm Power levels of up to +10 dBm Not as accurate as InGaAs. Can be affected by temperature Not recommended above 1550 nm

6 3.1 Typical Detector Spectral responses New InGaAs detectors work well at 850 nm.

7 4. Keypad Power On/Off Connector release Wavelength toggle and special features DUAL FUNCTION dBm, dBr & W + SET REF DUAL FUNCTION Hold + Min/Max Connector housing cap

8 5. Instrument Care Keep the instrument in a carry case during storage and transport Use only high quality batteries. For prolonged storage remove batteries. The instrument is resistant to normal dust and moisture, however it is not waterproof. If moisture gets into the instrument, remove batteries & dry it out carefully before using it again. Where possible, keep instrument away from strong sunlight. Clean the instrument case using Iso-Propyl-Alcohol (IPA) or other non solvent cleaning agents. DO NOT use Acetone or other active solvents as damage may result.

9 6. Operation 1.Fit batteries 2.Turn power meter on 3.Select / determine test cord configuration 4.Fit correct adaptor style to meter 5.Measure

Fit batteries To Fit Batteries. Press battery cover latch down and push away from case. Insert 2 ‘AAA’ cells Replace battery cover Battery life. Alkaline ‘AAA’ batteries: 300 Hrs Low Battery Display. Indicator shows when batteries are low. Warning. Do not use lithium batteries, or other batteries with a nominal voltage greater than 1.8 V as the instrument may become damaged.

Power On To turn on Push the Aqua [On/Off] button To Defeat auto time out. Press [On/Off] & [HOLD] for several seconds. Instrument will beep twice. ‘on’ will display. ‘Perm’ will display on the upper part of the LCD. 10 minutes auto off Permanent operation Low battery indicator

Determine type of test cord Identify fibre type required for test cord and configuration required. Connector / boot colours may identify the fibre type:- OM1 (62.5 µm) Beige OM2 (50 µm) Black OM3 (50 µm) Aqua SMF Blue or Green Cordage colours may identify the fibre type:- SMF: Yellow MMF Blue, Grey/Slate, Aqua or Orange Unlike sources, power meters accept both PC and APC connectors. EXCEPTION – wavelength selective meters are end face specific!

Fit connector Once the required test cordage configuration is identified, a matching adaptor for the power meter can be selected. Fitting the adaptor depends upon meter style

14 Standard & Wavelength Selective Instruments Supplied with :- SC connector as standard Other connector styles include:- ST, FC, LC, E2000, 2.5mm Universal, SMA, MU, D4, DIN * Universal not recommended for sources

15 To fit / change an adaptor / connector Locate quick release button on front of instrument at base of connector housing Push and hold button in Pull out existing adaptor Fit new adaptor Slot to outside

16 XL Series Connectors Industry standard 7/8”-28 TPI adaptors Select required adaptor style Screw on adaptor

17 7. Operating Modes 1.Measure Power: If receiving light from a ‘simple’ source. –Meter will display power. –dBm, dBr or W –The operator must select correct wavelength. 2.Modulation Frequency: Automatic display of modulation frequency. –Modulation 200 to 2,500 Hz 3.Multi-fibre Identification number: Automatic display of 12 fibre identification numbers. Connect power meter to DUT. In the presence of light the meter will operate in one of three ways:

Measure Power Power meter receives light from the source. User must select the correct wavelength. To select wavelength. Toggle [λ  ] or [  λ] to select λ –Wavelength toggling is circular. [<λ] [>λ]

Test Tone When receiving modulated light. Instrument displays modulated frequency & beeps. When receiving Test Tone. 270, 1,000 or 2,000 Hz. Instrument displays modulated frequency & beeps. Tone measurement can be disabled in Slow Mode.

7.3 Fibre ID Number When receiving a Multi-fibre identification signal: Displays Fibre identification number Applies to KI9600 Firmware version r0.05 and above. Legacy instruments will display a modulation frequency. 20 Some Light sources have the ability to send a ‘multi-fibre identification’ number in the range of 1 to 12.

21 8. Log/linear Display 1.Absolute Mode Measure actual power level at a particular location – dBm –Typically used during installation & maintenance activities. 2.Relative Mode Measure power level ‘relative’ to a particular location – dBr –Typically used for loss measurement. 3.Linear Measures power in watts – nW, µW, W –Typically a laboratory measurement. The meter defaults to last setting and wavelength at power on. The power meter can display power in logarithmic (dB) or Linear (W) units.

22 Toggle - Absolute/Relative/Linear To toggle between Absolute / Relative and Linear mode. Briefly, Press soft button [dB/dBm/mW] to toggle between the three modes. [dB/dBm/mW] dBm dBrW [dB/dBm/mW]

23 Set Reference Must be in Relative mode (dBr) not Absolute mode (dBm). Press and hold [Set Ref] for several seconds. –Meter will beep 2 times and zero at indicated wavelength. –Reference value remembered at power off. [Set Ref] dBr

9. Special Features 24 1.Hold This feature is useful where you want to show a measurement to a third party. 2. Min & Max recording This feature is useful where a level needs to be monitored over a time period. 3. SlowMode Tone detection disabled, enables measurement power in the presence of audio level modulation. Improved low power measurement accuracy. 4. TamperLock Mode Display settings are locked. Useful for low skilled areas or where only 1 wavelength is in use.

9.1 Hold Function To activate the Hold function: Briefly press [HOLD] The instrument will beep. The word ‘Hold’ will flash in the lower RHS of the display. To turn Hold off. Briefly press [HOLD] 25 [Hold]

9.2 Min / Max To retrieve the Maximum and Minimum value: Press and hold [Max Min] Instrument will beep twice and the word ‘min’ will display on the upper RHS of the LCD. Repeat above to toggle to ‘max’ Repeat above to turn function ‘Off’. 26 Min Max [Max Min] To reset Max/Min: Toggle to another wavelength and back or Turn power Off and then back On.

9.3 SlowMode To Activate at Power On Press and Hold [dB/dBm/mW] while turning meter On. “- tonE” will be displayed. To Activate when meter powered On Press and Hold [λ  ], then press [dB/dBm/mW] “- tonE” will be displayed. To Activate when test tone detection is active Press [dB/dBm/mW]. 27 When SlowMode is On, alternating “  ” and “B” symbols will be displayed. To exit SlowMode Press and hold [λ  ], then press [dB/dBm/mW] or turn power Off and then back On.

9.4 Tamper Lock Mode To activate Set meter to required λ & measurement mode, e.g. 850 and dBm Press and hold [λ  ], then press and hold [HOLD] ‘codE’ will display Press any 6 keys, other than [Power] record keystroke sequence for future use. Instrument will beep 3 times and display ‘Lout’ When active ‘ >>’ displayed To clear Press and hold [λ  ] & [HOLD] whilst turning power On ‘codE’ will display, enter 6 key code sequence If successful ‘PASS’ will display. Alternatively, TamperLock will be cleared after 3 unsuccessful attempts. 28

Application Notes Application Notes Comprehensive selection available at 29