Benoit Scherrer, ISBI 2011, Chicago Toward an accurate multi-fiber assessment strategy for clinical practice. Benoit Scherrer, Simon K. Warfield.

Slides:



Advertisements
Similar presentations
Diffusion Tensor Imaging
Advertisements

1 Detecting Subtle Changes in Structure Chris Rorden –Diffusion Tensor Imaging Measuring white matter integrity Tractography and analysis.
Institute for Biomedical Engineering EXCITE Afternoon Hands-On MRI Sessions: fMRI & DTI.
Methods for Medical Imaging– Prof. G. Baselli 2012 Diffusion weighted MRI and DTI tractography Maria Giulia Preti
National Alliance for Medical Image Computing Diffusion Weighted MRI.
Statistical Parametric Mapping
Mapping Cortical Development Using Diffusion Tensor Imaging Jeff Neil, MD, PhD Departments of Neurology, Radiology and Pediatrics.
DTI group (Pitt) Instructor: Kevin Chan Kaitlyn Litcofsky & Toshiki Tazoe 7/12/2012.
Parameters and Trade-offs
DIFFUSION TENSOR IMAGING
MaxEnt 2007 Saratoga Springs, NY
ADC and ODF estimation from HARDI
The Danish National Research Foundation’s Center of Functionally Integrative Neuroscience Aarhus University / Aarhus University Hospital Diffusion weighted.
High Angular Diffusion Imaging and its Visualization… Limitations of DTI Why HARDI is better?!? Different HARDI models My ideas and current work.
Diffusion Tensor MRI And Fiber Tacking Presented By: Eng. Inas Yassine.
Inferring Axon Diameter Sizes using Monte Carlo Simulations of Magnetic Resonance Oscillating Gradient Spin Echo Sequences ME Mercredi 1, TJ Vincent 2,3,
Diffusion Tensor Imaging Tim Hughes & Emilie Muelly 1.
Reproducibility of diffusion tractography E Heiervang 1,2, TEJ Behrens 1, CEM Mackay 3, MD Robson 3, H Johansen-Berg 1 1 Centre for Functional MRI of the.
Geometric Flows over Lie Groups Yaniv Gur and Nir Sochen Department of Applied Mathematics Tel-Aviv University, Israel HASSIP, September 2006, Munich.
DTI-Based White Matter Fiber Analysis and Visualization Jun Zhang, Ph.D. Laboratory for Computational Medical Imaging & Data Analysis Laboratory for High.
ISMRM 2010 Quantitative Imaging and MS. N. D. Gai and J. A. Butman, NIH T1 Error Analysis for Double Angle Technique and Comparison to Inversion Recovery.
Master thesis by H.C Achterberg
Introduction to diffusion MRI
Diffusion Physics H 2 O in the body is always in random motion due to thermal agitation B.M. Ellingson, Ph.D., Dept. of Radiological Sciences, David Geffen.
05/19/11Why’n’how | Diffusion model fitting and tractography0/25 Diffusion model fitting and tractography: A primer Anastasia Yendiki HMS/MGH/MIT Athinoula.
Multi-site Investigation of DTI Reproducibility K. G. Helmer 1, M-C. Chou 2, A. Song 3, J. Turner 4, B. Gimi 5, and S. Mori 6 1 Massachusetts General Hospital,
J OHNS H OPKINS U NIVERSITY S CHOOL O F M EDICINE Statistically-Based Reorientation of Diffusion Tensor Field XU, D ONGRONG S USUMU M ORI D INGGANG S HEN.
Rician Noise Removal in Diffusion Tensor MRI
Imaging Sequences part II
Brain Lab Imaging Didactics
Benoit Scherrer, ISBI 2010, Rotterdam Why multiple b-values are required for multi-tensor models. Evaluation with a constrained log- Euclidean model. Benoit.
Ramifications of Isotropic Sampling and Acquisition Orientation on DTI Analyses David H. Laidlaw 1, Song Zhang 1, Mark Bastin 2,3, Stephen Correia 4, Stephen.
Trade-offs between Angular and Spatial Resolution in High Angular Resolution Diffusion Imaging Liang Zhan 1, Neda Jahanshad 1, Alex D. Leow 2,3, Matt A.
Tensor Distribution Function in Multiple Shell High Angular Resolution Diffusion Imaging Tensor Distribution Function in Multiple Shell High Angular Resolution.
Instructor Kwan-Jin Jung, Ph.D. (Carnegie Mellon University) Technical Assistant Nidhi Kohli (Carnegie Mellon University) David Schaeffer (University of.
NA-MIC National Alliance for Medical Image Computing Validation of DTI Analysis Guido Gerig, Clement Vachet, Isabelle Corouge, Casey.
NA-MIC National Alliance for Medical Image Computing NAMIC UNC Site Update Site PI: Martin Styner Site NAMIC folks: Clement Vachet, Gwendoline.
References: [1]S.M. Smith et al. (2004) Advances in functional and structural MR image analysis and implementation in FSL. Neuroimage 23: [2]S.M.
DSim: An MR Diffusion Weighted Imaging Simulator Bob Dougherty Shyamsundar Gopalakrishnan Stanford University June 13, 2008.
Luke Bloy1, Ragini Verma2 The Section of Biomedical Image Analysis
Analytic ODF Reconstruction and Validation in Q-Ball Imaging Maxime Descoteaux 1 Work done with E. Angelino 2, S. Fitzgibbons 2, R. Deriche 1 1. Projet.
Contrast Mechanism and Pulse Sequences
Fiber Demixing with the Tensor Distribution Function avoids errors in Fractional Anisotropy maps Liang Zhan 1,Alex D. Leow 2,3, Neda Jahanshad 1, Arthur.
Sharpening Improves Clinically Feasible Q-Ball Imaging Reconstructions
FMRI – Week 4 – Contrast Scott Huettel, Duke University MR Contrast FMRI Graduate Course (NBIO 381, PSY 362) Dr. Scott Huettel, Course Director.
BMI2 SS08 – Class 7 “functional MRI” Slide 1 Biomedical Imaging 2 Class 7 – Functional Magnetic Resonance Imaging (fMRI) Diffusion-Weighted Imaging (DWI)
Conclusions Simulated fMRI phantoms with real motion and realistic susceptibility artifacts have been generated and tested using SPM2. Image distortion.
NA-MIC National Alliance for Medical Image Computing Mathematical and physical foundations of DTI Anastasia Yendiki, Ph.D. Massachusetts.
NA-MIC National Alliance for Medical Image Computing NAMIC UNC Site Update Site PI: Martin Styner UNC Site NAMIC folks: C Vachet, G Roger,
Measuring Water Diffusion In Biological Systems Using Nuclear Magnetic Resonance Karl Helmer HST 583, 2006
Robust Regularization for the Estimation of Intra-Voxel Axon Fiber Orientations Also presented at MMBIA Anchorage, Jun, 2008 Alonso Ramirez-Manzanares.
NA-MIC National Alliance for Medical Image Computing UNC/Utah-II Core 1 Guido Gerig, Casey Goodlett, Marcel Prastawa, Sylvain Gouttard.
DTI Acquisition Guide Donald Brien February 2016.
COMPARATIVE LATERALIZING ABILITY of MULTIMODALITY MR IMAGING in TEMPORAL LOBE EPILEPSY ¹ Karabekir Ercan, M.D. ¹ ¹ H.Pinar Gunbey, M.D. ¹ ¹ Elcin Zan,
Data analysis steps Pre-process images to reduce distortions
Diffusion Tensor MRI From Deterministic to Probabilistic Modelling
Mapping White Matter Connections in the Brain using Diffusion-Weighted Imaging and Tractography Andy Alexander Waisman Center Departments of Medical Physics.
Parameters which can be “optimized” Functional Contrast Image signal to noise Hemodynamic Specificity Image quality (warping, dropout) Speed Resolution.
Melanie Martin University of Winnipeg
Microstructure Imaging Sequence Simulation Toolbox
FMRI data acquisition.
Diffusion Tensor Imaging
Conclusion/Discussion
Introduction to diffusion MRI
Introduction to diffusion MRI
Introduction to diffusion MRI
Eduardo H. M. S. G. de Figueiredo, BSc, Arthur F. N. G
Anisotropy Induced by Macroscopic Boundaries: Surface-Normal Mapping using Diffusion-Weighted Imaging  Evren Özarslan, Uri Nevo, Peter J. Basser  Biophysical.
3T-versus-7T DTI with 36 diffusion-encoding directions at b = 3000 s/mm2 and 2.0 × 2.0 × 2.0 mm isotropic voxel resolution. 3T-versus-7T DTI with 36 diffusion-encoding.
Presentation transcript:

Benoit Scherrer, ISBI 2011, Chicago Toward an accurate multi-fiber assessment strategy for clinical practice. Benoit Scherrer, Simon K. Warfield

Benoit Scherrer, ISBI 2011, Chicago Diffusion imaging  Diffusion tensor imaging (DTI)  Describes the 3-D local diffusion with a 3-D tensor  Requires relatively short acquisitions  Reveals major fiber bundles = “highways” in the brain  Assessment of underlying fiber bundles characteristics (fractional anisotropy, radial diffusivity, …)  Widely used Good approximation for voxels containing a single fiber bundle direction But inappropriate for assessing multiple fiber bundles orientations

Benoit Scherrer, ISBI 2011, Chicago Overcome the limitations of DTI  Novel q-space sampling schemes [Hagmann, P et al., 2006]  Cartesian q-space sampling q-space : space of the diffusion-sensitizing gradients  Spherical q-space sampling HARDI  Single shell, multi-shell [Hagmann, P et al., 2006]

Benoit Scherrer, ISBI 2011, Chicago Overcome the limitations of DTI  Novel models for characterization of the DW-signal  Non-parametric: DSI, QBI, E-QBI, …  Parametric: SD, GDTI, DOT, …  do not characterize the proportions of each fiber bundle  do not enable the assessment of the fiber bundle characteristics Drawbacks:  Describe the general shape of the diffusion profile  Do not consider each fiber bundle independently HARDICartesian

Benoit Scherrer, ISBI 2011, Chicago Consider in each voxel a mixture of independent fibers Multi-fiber modeling  Ball and stick model [Behrens 2003] [FSL] Estimate “sticks” to represent a fiber bundle  Multi-tensor representation of a MFM  Assessment of diffusion tensor parameters for each fiber bundle independently  Great interest for fiber integrity assessment  Individual fiber bundle well represented by a single tensor  multiple fiber bundles expected to be well represented by a set of tensors. Were known to be numerically challenging and unstable. [Scherrer and Warfield, ISBI2010, ISMRM2010] : Theoretical demonstration that multiple b-values are required. Single non-zero b-value : collinearity in the parameters  Do not enable the fiber characteristics assessment

Benoit Scherrer, ISBI 2011, Chicago Contributions  A novel acquisition scheme for the assessment of multiple fibers. Combines CUbic and SPherical q-space sampling (CUSP) Acquisition of multiple b-values without increasing the TE  A novel procedure for the estimation of a multi-fiber model (MFM) Variational log-Euclidean framework Ensures valid and regularized tensor estimates CUSP-MFM CUbe and SPhere Multi-Fiber Model

Benoit Scherrer, ISBI 2011, Chicago. CUbe and SPhere acquisition scheme.

Benoit Scherrer, ISBI 2011, Chicago CUSP acquisition scheme  Theoretical demonstration ISBI2010: Multiple b-values are necessary for the full MFM estimation 8  How to satisfy this requirement? First remark: Pulsed-gradient spin echo (PGSE) sequence b-value, echo time (TE) and gradient strength are linked proton gyromagnetic ratio duration of the diffusion gradient pulses time between diffusion gradient RF pulses diffusion sensitizing gradient norm Modify the nominal b-value  different TE [Perrin2005] For a single-shell HARDI G=1 for all gradients

Benoit Scherrer, ISBI 2011, Chicago CUSP acquisition scheme 9  How to satisfy the requirement of multiple b-values?  Multiple shell HARDI acquisition (G≤1)  Nominal b-value = for the largest shell  TE = TE for the highest b-value.  Longer acquisition time  Higher geometric and intensity distortion  Lower SNR for all measurements  Separate single-shell HARDI acquisitions (G=1) Different nominal b-values  Spatial misregistration caused by motions between scans  Different TE => Different geometric distortions patterns [Qin2009] SNR at 3Tesla We need multiple non-zero b-values. BUT do we really need a set of full shells ?

Benoit Scherrer, ISBI 2011, Chicago CUSP acquisition scheme  CUbe and SPhere q-space sampling Combine one HARDI shell and the gradients on the enclosing cube 10 Never used for multiple fiber bundle assessment  Hexahedral gradients √2-norm : double the nominal b-value  Tetrahedral gradients √3-norm : nominal b-value x 3  Fix a nominal b-value (generally 1000s/mm2 for adult brains) Inspired by [Conturo96], [Peled2009]  Gradients of the HARDI shell : unit-norm gradients  Provides multiple non-null b-values without modifying the TE  Introduces high b-values, known to better characterize MFMs  Does not increase the imaging time nor the distortion

Benoit Scherrer, ISBI 2011, Chicago. Novel MFM estimation procedure. [ In conjunction with the CUSP acquisition… ]

Benoit Scherrer, ISBI 2011, Chicago Diffusion signal modeling  Homogeneous Gaussian model (DTI) Diffusion weighted signal S k along a gradient g k (||g k ||=1) : D: 3x3 diffusion tensor, S 0 : signal with no diffusion gradients, b k : b-value for the gradient direction k.  MFM DW signal modeling. For N fibers =2:  An isotropic compartment to model the diffusion of free water  N fibers anisotropic compartments related to the fibers Diffusivity of free waterModels the two fiber tracts Fractions of occupancy

Benoit Scherrer, ISBI 2011, Chicago Log-Euclidean framework  log-Euclidean representation  Has been successfully applied to the one-tensor estimation [Fillard et al., 2007] Tensor estimation  Care must be taken to ensure non-degenerate tensors  We consider Tensors with null or negative eigen-values are at an infinite distance

Benoit Scherrer, ISBI 2011, Chicago A Novel MFM fitting procedure  Variational framework Simultaneous estimation and regularization of f and L : minimizing the energy: Least-square criteria:Spatial homogeneity : Anisotropic regularization: Gradient of the tensor field j

Benoit Scherrer, ISBI 2011, Chicago. Evaluation.

Benoit Scherrer, ISBI 2011, Chicago Evaluation  Numerical simulations  100 tensors crossing with a given angle in various configurations  Simulation of the DW signal, corrupted by a Rician noise (SNR=30dB) Ground truthHARDI35-MFM 5B=0 + 1 shell 30directions CUSP35-MFM 5B=0 + 1 shell 16directions + 1xhexahedral+ 2xtetrahedral CUSP-MFM achieves a better tensor estimation accuracy

Benoit Scherrer, ISBI 2011, Chicago Evaluation  How to design a CUSP acquisition? How many repetitions of the gradients with norm>1 to counterbalance the lower SNR?  Evaluation of the relationship between three parameters:  Number of total images acquisitions  Optimal number of repetition of sqrt(2)-norm gradients  Optimal number of repetition of sqrt(3)-norm gradients  Comparison of the estimation accuracy with the ground truth Average log-Euclidean distance  comparison of the full tensors  Simple linear model: (blue is better) 35

Benoit Scherrer, ISBI 2011, Chicago Evaluation  Quantitative evaluation CUSP-MFM achieves in average the better angular resolution.  Simulation of various crossing angles  Comparison with the ball-and-stick model (FSL) Metric: Average minimum angle (Tuch2002) Crossing Angle AMA

Benoit Scherrer, ISBI 2011, Chicago Evaluation  Quantitative evaluation Average log-Euclidean distance between the tensors Average absolute difference between the fractions  Comparison of three acquisition schemes Introducing multiple b-values is better than employing a large number of directions Crossing Angle Whole tensors estimation accuracyFractions estimation accuracy

Benoit Scherrer, ISBI 2011, Chicago Evaluation  Tensors representing two uniform crossing fibers Assessment of the fractional anisotropy along the tracts Quantitative analysis HARDI35-MFM CUSP35-MFM The FA of two uniform crossing fibers is uniform with CUSP-MFM

Benoit Scherrer, ISBI 2011, Chicago Evaluation – real data HARDI35-MFMCUSP35-MFM HARDI35-FSLCUSP35-FSL CUSP-MFM: Better tensor uniformity (regions 1, 2, 3) vs HARDI-MFM Better alignment of the two tensors when single fiber (4) FSL: Not enough data to estimate correctly the ball-and-stick model?

Benoit Scherrer, ISBI 2011, Chicago Evaluation – real data  Preliminary results MFM tractography HARDI45-1TCUSP45-MFM HARDI45-1TCUSP45-MFM CUSP-MFM tracts better represent expected connectivity Corticospinal tractsArcuate fasciculus

Benoit Scherrer, ISBI 2011, Chicago Discussion CUSP-MFM CUSP-MFM enables to perform both tractography and individual fiber bundles’ characteristics assessment.  A novel acquisition scheme  Satisfies the need of multiple b-values and introduces high b-values  Does not increase the echo time: no impact on the distortion  Provide the relation to design a CUSP acquisition  A novel multi-tensor fitting procedure  log-Euclidean framework: ensures valid tensors  Variational formulation: simultaneous estimation and regularization Focus on very short duration acquisitions, compatible with routine clinical practice Evaluation

Benoit Scherrer, ISBI 2011, Chicago Discussion Future works  Model selection  Number of fibers at each voxel?  Investigation of the optimal CUSP  Finer discretization of the cube edges?  Optimal nominal b-value?  Full evaluation on real data: comparison with other approaches  Q-Ball imaging, Spherical deconvolution, …

Benoit Scherrer, ISBI 2011, Chicago Thank you for your attention, CUSP-MFM