An acoustic resonator to enhance the sensing of cells within micro-fluidic chambers R. J. Townsend 1, M. Hill 1, N. R. Harris 2, S. P. Stacey 3, L. A.

Slides:



Advertisements
Similar presentations
Normal mode method in problems of liquid impact onto elastic wall A. Korobkin School of Mathematics University of East Anglia
Advertisements

of Single-Type-Column 3D silicon detectors
Ozone Level ppb (parts per billion)
Copyright 2011 Elsevier Inc. All rights reserved.
FIGURE 5.1 Potentiometric displacement sensor.
ANALYSIS OF THE LIGHT WEIGHT DEFLECTOMETER IN-SITU STRESS AND STRAIN
University of Greenwich Computing and Mathematical Sciences
Photon Collimation For The ILC Positron Target Lei Zang The University of Liverpool Cockcroft Institute 24 th March 2007.
Introduction Acoustic radiation forces on particles within standing waves are used in processes such as particle separation, fractionation and agglomeration.
Moisture effect on the dielectric response and space charge behavior of mineral oil impregnated paper insulation Jian Hao1, 2, George Chen2, Ruijin.
High frequency annular arrays can provide very good resolution in ultrasound bio-microscopy Numerical simulation of their imaging patterns is essential.
EXPERIMENTAL & NUMERICAL INVESTIGATION OF WIND LOADS ON ROOFS FOR VARIOUS GEOMETRIES İsmail EKMEKÇİ, Mustafa ATMACA* and Hakan Soyhan The University of.
A Bezier Profiled Horn for Reducing Penetration Force with Applications in Surgery Dung-An WANG and Hai-Dang Tam NGUYEN Graduate Institute of Precision.
ENE 428 Microwave Engineering
S A L T M O D A computer program for the prediction of the salinity of soil moisture, ground water and drainage water, the depth of the water table, and.
Stresses due to fluid pressure in thin cylinders
Living room acoustics You can use the heading from the model documentation for the title. © 2013 COMSOL. All rights reserved.
Sedan Interior Acoustics
1 Application of for Predicting Indoor Airflow and Thermal Comfort.
School of Mechanical, Aerospace & Civil Engineering Postgraduate Research Conference, PGR-MACE10 Performance of two k T -k L -ω models in a separation-induced.
Using DEM-CFD method to model colloids aggregation and deposition
Technická univerzita v Liberci Magnetic Field of Massive Conductor at Low Frequency Martin Truhlá ř Faculty of Mechatronics, Informatics and Interdisciplinary.
Running a model's adjoint to obtain derivatives, while more efficient and accurate than other methods, such as the finite difference method, is a computationally.
Waveguide group velocity determination by spectral interference measurements in NSOM Bill Brocklesby Optoelectronics Research Centre University of Southampton,
Electronics Cooling MPE 635 Mechanical Power Engineering Dept.
Electricity and It’s charge
Minimising the Propulsive Power Consumption of a Fleet of AUVs Pareecha Rattanasiri 1, Philip A. Wilson and Alexander B. Phillips Faculty of Engineering.
A New Design Tool for Nanoplasmonic Solar Cells using 3D Full Wave Optical Simulation with 1D Device Transport Models Liming Ji* and Vasundara V. Varadan.
Design and Simulation of a MEMS Piezoelectric Micropump Alarbi Elhashmi, Salah Al-Zghoul, Advisor: Prof. Xingguo Xiong Department of Biomedical Engineering,
Trough Figure 2. Entire trough used for sand transmission tests. Sound transmission in geological materials Mikel-Stites M. 1,2, Ulrich R. 2,3, El Shafie.
School of Physics and Astronomy, University of Nottingham, Nottingham, NG7 2RD, UK. Electrically pumped terahertz SASER device using a weakly coupled AlAs/GaAs.
EE 5340/7340, SMU Electrical Engineering Department, © Carlos E. Davila, Electrical Engineering Dept. Southern Methodist University slides can be.
Adaptive Composite Blades for Horizontal Axis Tidal Turbines R.F. Nicholls-Lee, S.R. Turnock and S.W. Boyd Fluid Structure Interactions Research Group,
2006 GSK Mathematical Modeling Symposium Modelling Particle Flow Dynamics Using Discrete Element Methods Mark Palmer, Valeriu Damian-Iordache, Pankaj DoshiRob.
Dr. Laila Guessous Suresh Putta, M.S. Student Numerical Investigations of Pulsatile Flows To develop a better understanding of the characteristics of pulsating.
Magnetic Field Characteristics of a Magneto-Biosensor Detection coil. John Eveness 1, Janice Kiely 2, Peter Hawkins 1, Richard Luxton 1. 1 Faculty of Applied.
HIGH CYCLE FATIGUE DELAMINATION MEASUREMENT AND GROWTH PREDICTION
Pierre Gélat National Physical Laboratory 3 April 2003 Developments in Acoustic Emission at the UK’s National Physical Laboratory.
Development of a Theoretical Model for Membrane Hydrophone Transfer Characteristics Pierre Gélat 3 April 2003.
Abstract An upgrade to the ATLAS silicon tracker cooling control system may require a change from C 3 F 8 (octafluoro-propane) to a blend containing 10-30%
Ultrasound – Physics & Advances
SOLUTION FOR THE BOUNDARY LAYER ON A FLAT PLATE
Theoretical Analysis of a Nanosensor based on WO 3 coated Carbon Nanotube for Ultra-high Sensitive Breath Acetone Sensing Ming Xia, Advisor: Prof. Xingguo.
Introduction The traditional method for actuating microengineered structures using PZT has been to use bulk PZT bonded to the structure in question. Work.
MSc and BSc projects for 2005/2006 Supervisor: Rune W. Time These projects are mainly intended for MSc thesis work, but may be simplified to BSc thesis.
A Comparison between Electroluminescence Models and Experimental Results D. H. Mills 1*, F. Baudoin 2, G. Chen 1, P. L. Lewin 1 1 University of Southampton,
Development of an Active Micromixer by Dielectrophrosis Particle Manipulating 姓名:黃朝鴻 Chao-hong Huang 班級:奈米一甲 學號:MA11V108.
BIOPARTICLE SEPARATION AND MANIPULATION USING DIELECTROPHORESIS Advisor: Yi-Chu Hsu Student: Le Van Cong ( 黎 文 功 ) Date: 11/04/2011.
Analysis and Design of Multi-Wave Dilectrometer (MWD) for Characterization of Planetary Subsurface Using Finite Element Method Manohar D. Deshpande and.
HYDRAULICS of steady and pulsatile flow in systemic circulation Motivation Experimental techniques for measurement pressure and flowrate How to calculate.
Slide # Basic principles The effect is explained by the displacement of ions in crystals that have a nonsymmetrical unit cell When the crystal is compressed,
Ultrasound Physics Reflections & Attenuation ‘97.
Figure 23.1: Comparison between microfluidic and nanofluidic biomolecule separation. (a) In microfluidic device, friction between liquid and the molecule.
Numerical Modelling of Needle-Grid Electrodes for Negative Surface Corona Charging System Y. Zhuang*, G. Chen and M. Rotaru University of Southampton,
Longitudinal Motion Characteristics between a Non- Matched Piezoelectric Sensor and Actuator Pair Young-Sup Lee Department of Embedded Systems Engineering,
Surface Acoustics Wave Sensors. Outline Introduction Piezoelectricity effect Fabrication of acoustic waves devices Wave propagation modes Bulk Wave sensor.
1/22 R. Long 1, P. Cawley 1, J. Russell 1,2 1. UK Research Centre in NDE, Imperial College 2. Rolls-Royce Marine, Derby.
Modelling and Simulation of Passive Optical Devices João Geraldo P. T. dos Reis and Henrique J. A. da Silva Introduction Integrated Optics is a field of.
Microphononic Crystals B. Ash, G. R. Nash, P. Vukusic ex.ac.uk/BenAsh Abstract. This project investigates.
Date of download: 5/28/2016 Copyright © ASME. All rights reserved. From: Ultrasonic Measurement of Rolling Bearing Lubrication Using Piezoelectric Thin.
CONVECTION : An Activity at Solid Boundary P M V Subbarao Associate Professor Mechanical Engineering Department IIT Delhi Identify and Compute Gradients.
All-Dielectric Metamaterials: A Platform for Strong Light-Matter Interactions Jianfa Zhang* (College of Optoelectronic Science and Engineering, National.
1 Opto-Acoustic Imaging 台大電機系李百祺. 2 Conventional Ultrasonic Imaging Spatial resolution is mainly determined by frequency. Fabrication of high frequency.
BCP Analysis Update Thomas Jones 22/7/16.
ANTENNA THEORY ANALYSIS AND DESIGN Chapter.1
Investigation of Flow in a Model of Human Respiratory Tract
A Dual Frequency, Ultrasonic, Microengineered Particle Manipulator
The application of an atmospheric boundary layer to evaluate truck aerodynamics in CFD “A solution for a real-world engineering problem” Ir. Niek van.
HYDRAULICS of steady and pulsatile flow in systemic circulation
Computed Tomography (C.T)
Presentation transcript:

An acoustic resonator to enhance the sensing of cells within micro-fluidic chambers R. J. Townsend 1, M. Hill 1, N. R. Harris 2, S. P. Stacey 3, L. A. Kuznetsova 3, K. A. J. Borthwick 3, W. T. Coakley 3 1 School of Engineering Sciences, University of Southampton, SO17 1BJ, UK 2 Electronics and Computer Science, University of Southampton, SO17 1BJ, UK. 3 School of Biosciences, Cardiff University, CF10 3TL, UK [1]J. J. Hawkes, M. J. Long, W. T. Coakley, and M. B. McDonnell, Ultrasonic deposition of cells on a surface, Biosensors & Bioelectronics, 19, pp , [2]M. Hill, Y.J. Shen, J.J. Hawkes, Modelling of layered resonators for ultrasonic separation, Ultrasonics, 40, no. 1-8, pp , [3]S.P. Martin, R.J. Townsend, L.A. Kuznetsova, K.A.J. Borthwick, M. Hill, M.B. McDonnell, W.T. Coakley, Spore and micro-particle capture on an immunosensor surface in an ultrasound standing wave system, Biosensors & Bioelectronics, 21, no. 5, pp , 2005 INTRODUCTION TO ACOUSTIC FORCES University of Southampton Figure 1: Schematic showing how particles move to the nodal plane of an acoustic standing wave. By generating a quarter-wavelength field and positioning the node close to the reflector surface, particles or cells will move towards the surface (figure 2). This has applications in the sensing of biohazard spores where sensitivity can be increased by moving the particles of interest to the sensor element, as compared to relying on diffusion alone [1]. Figure 2: A quarter-wavelength chamber where spores are pushed up to a sensor surface NUMERICAL SIMULATIONS A 1-d impedance transfer model coded in MATLAB [2] is used to predict the nature of the acoustic field within a device fabricated and tested at Cardiff University, who also instigated the work reported here [3]. The device operates at 2.8MHz, therefore the depth of the quarter-wavelength fluid chamber was chosen to be ~130 m. The various layers of the device are essentially clamped together with the fluid/particle sample passing through inlet and outlet ducts extending the width of the chamber (10mm). The influence of the reflector thickness is investigated, where Figure 4 contains the modelled pressure field and resulting radiation force on a 1 m latex bead. Experimentally measured acoustic pressure amplitude data, collected at Cardiff University, is used as input to the model. It can be seen that the geometry of the resonator has a significant impact on the acoustic behaviour of the device and position of the node; i.e. as the reflector thickness is increased, the pressure node moves from the fluid layer and into the reflector layer. This in turn will influence the capture of cells on the reflector surface. The radiation force profile in the fluid (Figure 4(b)) shows that in the case of a 1mm thick reflector, the majority of particles within the chamber will experience a positive force up to the reflector surface. However, for a 0.98mm reflector particles will be forced away from the reflector surface and will not be captured. Figure 4: (a) Pressure field and (b) radiation force for a range of reflector thicknesses. The generation of this mode relies on an nλ/2 resonance within the reflector layer which imposes a pressure minimum (node) close to the fluid/reflector interface. Because of this resonance, the acoustic energy is predominantly associated with the reflector rather than the fluid layer. Figure 5: Particle capture in biohazard detection system for a range of reflector thicknesses ( - modelled, - measured ) Slide depth (mm) Capture per image % Particle Capture Particles within an ultrasonic standing wave experience acoustic radiation forces. These forces move the particles to acoustic nodes within the acoustic field, as demonstrated schematically in Figure 1 where two nodes are present. A piezo-electric transducer is used to generate the acoustic field. The thickness of the water layer, in which the particles are held, and the glass reflector must be carefully selected in order to support a standing-wave of sufficient energy. REFERENCESCONCLUSIONS Acoustic resonators have significant potential in particle manipulation devices. Their operation is very sensitive to the acoustic design, but can be evaluated using numerical modeling. The simulations used allow the position of the acoustic node, and plane to which particles converge, to be predicted with reasonable accuracy. Further, the simulation can predict the combined effect of the acoustic radiation force and laminar flow profiles, and resulting effectiveness of the system when compared to other geometric designs. It is hoped that this modeling technique will lead to an improved quarter-wavelength resonator design. Water Acoustic field Nodal planes Particles or cells Piezoelectric Transducer Glass reflector Here, a quarter-wavelength system is investigated which moves spores to a surface using acoustic radiation forces. The acoustic field and movement of particles is calculated numerically and gives an indication of how effective the system is at transporting particles. This is compared to experimental data. This phenomenon is being exploited in devices fabricated using micro- engineering fabrication techniques to ultimately be incorporated into Micro- total-analysis-systems (μTAS) for rapid processing and sensing of small fluid/particle samples. PARTICLE CAPTURE RESULTS Because it operates as a flow-through devices, a parabolic laminar flow profile exists within the fluid chamber. Therefore, as well as radiation forces, fluid drag forces are acting on the particles. Again by using MATLAB to resolve both the acoustic and drag forces, the trajectories and concentration of particles can be calculated. In turn, the proportion of particles captured can be estimated. Experimental data and modelled data are shown in Figure 5, where the length of the chamber and reflector surface are 20mm. (The modelled data assumes that all particle which contact the surface will adhere, however, this is not necessarily true experimentally. Therefore, the modelled data is normalised such that the trends may be compared.) QUARTER-WAVELENGTH OPERATION Biohazard spores Piezoelectric Transducer Sensor surface Glass reflector /2 y p(y) Transducer Glass reflector Matching layer This unfavourable distribution of energy is in part illustrated in Figure 3, where the pressure amplitude in the reflector layer is significantly greater than that in the fluid layer. Whilst, these systems are associated with low energy and low acoustic radiation force, a quarter-wavelength system still provides a promising means to collect particles on a surface, Figure 3: Typical acoustic pressure field distribution. The graph shows that the proportion of particles captured on the surface is low for thin reflectors <1mm, due to the positioning of the pressure node within the fluid layer (Figure 4). However, at greater thicknesses, the node is located within the reflector layer and particle capture reaches a maximum for a 1.01mm thick reflector. In this case, a significant proportion of the fluid layer is associated with a positive radiation force up to the reflector surface. Generally, the experimental and predicted capture data show very similar trends, and using predictions of the acoustic pressure and radiation force profile it is possible to interpret these trends. This study supports further work using the simulation to improve the design of such resonators.