Solar Energy Technology Science Summer Camp Session 9: Fri 9:00 AM - 12:00 N : Field trip to Energy Masters and Installing/Commissioning the System.

Slides:



Advertisements
Similar presentations
Solar PV On-Site Guide Solar PV On-Site Installers Guide.
Advertisements

Commissioning, Maintenance, and Troubleshooting
Introducing Electricity and Electrical Safety
Introducing Electricity and Electrical Safety
The Electrical GuruTM Paul W. Abernathy,CME
Solar Schoolhouse and San Mateo College Designing and Installing Solar Electric Systems Types of Solar Electric Systems For Technology Teachers San Mateo.
PV System Design and Installation LO 8 – PV Electrical Design.
A/C Generator Systems.
PHSAUTOMOTIVESALSPHSAUTOMOTIVESALS Charging System tests & Voltage information Checking the charging system with just a volt meter.
© 2011 Ericson Manufacturing, Willoughby, Ohio
Solar Home UPS 850VA & 1400VA India’s first Sine wave inverter with in built Solar Charge Controller and Controlled DC Load Output. Simultaneous Charging.
Charging System Service
AGENDA INTRODUCTION CELLS AND COMPONENTS PV PERFORMANCE PV APPLICATIONS CODES AND STANDARDS EMERGENCY RESPONSE.
Sustainable Energy Systems Engineering Peter Gevorkian Ch 2: Solar Power Generation Design Brevard Community College EST1830 Bruce Hesher.
Lesson 9: Electrical Components
Quiz in progress Don’t forget to put your name on the quiz 1) How hard was the quiz? A.Easy B.Hard C.In-between D.What quiz?
OBJECTIVES 1. Identify the three general steps required for the diagnostics and troubleshooting of PV systems and demonstrate knowledge of their use.
Objectives Review electric circuits and electricity pricing - Introduce HW5 Select conductor and conduit List electrical devices.
Designing Solar PV Systems (Rooftops ). Module 1 : Solar Technology Basics Module 2: Solar Photo Voltaic Module Technologies Module 3: Designing Solar.
Using a DVOM.
PV System Components Advanced Engineering The Technology Landstown High School.
7.1.3 Student Book © 2005 Propane Education & Research CouncilPage Applying a Systems Approach to Gas Appliance Troubleshooting Troubleshooting.
Dimensioning and Protection of PV Plants with examples of design
13.2: Current and Voltage Objectives: Ampere Voltage Volt Voltmeter
المــــركــز الوطنــــــي لبحــــــوث الطـــاقــــــة National Energy Research Center Commissioning Tests & Inspection of PV Systems According to IEC
Assumption University Thailand EE4503 Electrical Systems Design Main Circuit 1.
Diagnostics of photovoltaic power plants operation
System Sizing Sizing methodologies Sizing calculations.
Power Systems DC Disconnects & Junction Boxes. Functions Overcurrent protection Solar Charge Controller PV Disconnect Solar Charge Controller Battery.
E8 / PPA Solar PV Design Implementation O&M Marshall Islands March 31-April 11, Preventive Maintenance.
Balance of Systems (BOS)
Lesson Measuring and Calculating Electricity. Interest Approach § Have you or your parents ever been using several appliances in the kitchen and had a.
ASK THE EXPERT SESSION Michael Ziloudis Solar PV Specialist.
Inverter power supply symptoms can be typically broken down into the following categories: 1. All Outputs Normal: 2. All Outputs Dead (no output): 3.
Grid Tied PV Systems – Part 5
Battery Backup PV Systems Design Considerations
SERVICE ENTRANCE EQUIPMENT
Diagnostics of photovoltaic power plants operation Vitezslav Benda, CTU Prague, Faculty of Electrical Engineering.
Electrical Safety, Subpart K
PV System Design and Installation LO 10 Performance Analysis and Troubleshooting.
PV System Design and Installation LO 5B - Solar Energy Fundamentals.
ESX10-T Electronic Circuit Protectors with Hazardous Area approvals.
STUDY OF ELEMENTS OF A 220/132/33KV SUBSTATION
SEC598F16 Photovoltaic Systems Engineering Session 12 PV System Components Inverters Balance of Systems (BOS) October 04, 2016.
Assessment and Design of Rooftop Solar PV system
Photovoltaic and Battery Primer
Solar PV Updates PDE Summit, December 2009
Photovoltaic Systems Engineering Session 21
Photovoltaic Systems Engineering Stand-Alone PV Systems – Review
Photovoltaic Systems Engineering Residential Scale – Part 2
How to Design and Implement a Reliable PV System which could last 30+ years ZAKI IQBAL SENIOR R&D ENGINEER RAK RESEARCH AND INNOVATION CENTER.
Subpart K Electrical Long recognized as a serious hazard.
PV System Quality and Performance
ELECTRICAL INSTALLATION AND MAINTENANCE (EIM) 5 INSTALL ELECTRICAL PROTECTIVE DEVICES FOR DISTRIBUTION, POWER, LIGHTING, AUXILIARY, LIGHTNING PROTECTION.
SOLAR INSTALLATION AND DESIGN: THE DOS AND DON’TS
AGENDA INTRODUCTION CELLS AND COMPONENTS PV PERFORMANCE
Smitty’s Two Minute Drill Photovoltaic Systems
Photovoltaic Systems Engineering Session 16 Solar+Storage Systems
AGENDA INTRODUCTION CELLS AND COMPONENTS PV PERFORMANCE
Photovoltaic Systems Engineering Residential Scale – Part 2
Photovoltaic Systems Engineering Session 19a Solar+Storage Systems
Objectives Learn about Electricity Pricing Electric systems.
Objectives Learn about 3 Phase vs. 1 phase F&N vs. 1 phase F&F
Solar Energy Commercialization Session 16
Solar Energy Commercialization Utility Scale Solar Development
Objectives Finish Transformers Introduce HW5 (Pricing)
Presentation transcript:

Solar Energy Technology Science Summer Camp Session 9: Fri 9:00 AM - 12:00 N : Field trip to Energy Masters and Installing/Commissioning the System

Day 3 Introduction Description of Facilities – if needed Go Over Day 2 and rest of Course Handout Notes Safety RulesReview Safety Rules –Safety first –Always follow safety rules

Session 9 Topics Installing the System (Instructor TBD) –Utility Interconnection –Permitting and Inspection. Details of Role Inverters Commissioning, Maintenance, and Troubleshooting Activities: 3

Getting Up and Running, Maintenance and Trouble shooting Utility Interconnection * Permitting and Inspection. Details of Role Inverters * Commissioning, Maintenance, and Troubleshooting * Activities:

PV System Design and Installation LO 10 Performance Analysis and Troubleshooting

Task/Skill Describe typical system design errors Describe typical system performance problems Associate performance problems with typical causes List equipment needed for typical system performance analysis Compare actual system power output to expected Identify typical locations for electrical/mechanical failure Performance Analysis and Troubleshooting (7% of test questions)

Overall PV System Efficiencies PV Array Input (DC) = 70 to 80% AC Output (AC) Reference 2

Typical Design Errors General Issues 1.Not accounting for shading issues (trees, chimneys, inter-row spacing, etc.) 2.Inadequate structural support (wind, snow, seismic and dead loads) Inverter Issues 1.Under/oversizing PV array relative to inverter capacity 2.Too many modules in a string (Voc x Temp Correction < Max Inverter DC input) 3.Too few modules in strings (Vmp with temp correction to make sure that do not drop below inverter cut-off voltage) 4.Under sizing wires for voltage drop (see voltage drop formula) NEC Issues 1.Under sizing overcurrent protection devices (Isc - fuses and circuit breakers) 2.Under sizing wires for ampacity requirements (Isc – wire sizes, conduit fill and temperature correction factors, etc.) 3.Equipment labeling

Performance Analysis and Trouble Shooting Tools 1.Basic tool kit (screw drivers, etc) 2.Irradiance meter 3.Multimeters DC Voltage DC Current (Clamp-on / Hall Effect) AC voltage (RMS) AC current (RMS) 4. Hydrometer (battery systems)

PV System Problems from 1000 Solar Roof Project in Germany Reference 2

Check Site Conditions 1.Module Condition 2.Array Condition 3.Roof condition 4.Array Shading 5.Inverter Condition (error messages, signs of charring, unusual noises, hot spots) 6.Wiring (connections, insulation abrasion, discoloration)

Check Performance Inverter Efficiency = Displayed AC Power Array Imp x Array Vmp Array IV Curve 1.Take irradiance temperature and measurement. 2.Apply correction factors 3.Measure Isc (current) and Voc (voltage) being produced by the array 4.Compare theoretical to practical

Check for Ground Faults 1.Possible signs 2.Voltage-to-ground from PV module frames, rack, inverter and other equipment. 3.Blown Ground Fault Fuse (> 1 amp fault) 4.Error code (minor fault) 5.Isolate and test individual module strings Causes Reference 3 1.Loose, broken or pinched wires 2.Loose connections 3.Rodent damage

Current Paths Ground Fault Protection Normal Operation

Current Paths Positive Ground Fault

Current Paths Negative Ground Fault