1200 kV AC Substations - Products and Integrated Solutions International UHV Symposium New Delhi, 29. January 2009 Edelhard Kynast Siemens AG, Energy.

Slides:



Advertisements
Similar presentations
Medium-Voltage Switchgear - Then and Now -
Advertisements

CONDITIONS FOR SUCCESSFUL INTERRUPTION:
1 CNS/GSS/2008/M1 1 Module 1 Basic Terminologies and Characteristics of Switchgear.
International Symposium on Standards for UHV Transmission System Impacts on UHV Substation Equipment On behalf of CIGRE WG A January 2009,
IEC Short-circuit current making and breaking tests Taiwan-European HVAC apparatuses Accreditation and Certification forum Harethe El Ouadhane.
SHS2 Gas insulated switch–disconnector / isolator
Concept Design Review (CoDR) Shore Station DC Breaker Cable model Transient Analysis Components.
INTRODUCTION OF ULTRA-HIGH VOLTAGE (UHV) 1000 kV AC TRANSFORMER
High Voltage Engineering
FIPTMV Medium Voltage Technology
Mr. Harethe El Ouadhane IEC member for IEC MT14. |Infrastructure Business | Germany | Test Engineer & Expert (Internal Arc, Making, Breaking.
3AH5 Vacuum Circuit-Breaker For Standard Applications
Standardization Aspects in UHV Networks New Delhi, January 2009 Denis Dufournet Chairman IEC TC17 Member CIGRE WG A3-22.
ABS Ennin, George Coleman, David Dadson & Anthony Ansah
Unit-3 SUBSTATIONS.
THE ELECTRIC SUB STATION
BRIEF ON THE REPORT OF CIGRE WG B4-45 –
ABSTRACT: Electricity is a form a energy and is playing vital role in the world. Electricity has become a part of human life. Electricity is developed.
Development and testing of 1100 kV GIS
MNS Sprint - A Market Driven Solution
All rights reserved Surge Arrester.
Frankfurt (Germany), 6-9 June 2011 Hans-Erik Olovsson – Sweden – Session 1 Network Components – Paper 0453 Innovative Compact 145/12 kV Indoor Air Insulated.
All rights reserved Gas-insulated Switchgear (GIS)
A low - cost high performance MV RMU with circuit breakers for use in remote controlled MV / LV substations Fabio GIAMMANCO Luca GIANSANTE 1 1.
SUBSTATIONS SESSION Chairman: Ernst GOCKENBACH Reporter: Mark WALDRON.
Medium Voltage Outdoor Apparatus Portfolio
1 Progress of, and prospects for, commercial applications of UHV 1100kV Transmission System in TEPCO 2 nd International Symposium on International Standards.
Cigre / IEC UHV Symposium, New Delhi Strategic Agenda for CIGRE‘s Technical Activities Klaus Fröhlich.
POWER HOUSE.
What is POWERGRID??? The Power Grid Corporation of India Limited (POWERGRID), is an Indian state-owned electric utilities company headquartered in Gurgaon,
First Draft Language (B) Service Equipment. In addition to the requirements in (A), service equipment shall contain the following information: (1)
A PRESENTATION OF PRACTICAL TRAINING ON “400KV GSS “ \
A SUMMER TRANNING PRESENTATION ON 400 KV GRID SUB STATION BIKANER
A Presentation On 132 KV GSS BEHROR
Submitted to: Submitted by:
SUBSTATION LAYOUT AND ACCESSORIES
Distribution Systems-General
Air Blast Circuit Breaker
Department of Electrical Engineering
A Training Presentation On 220 KV GSS CHOMU,JAIPUR
A SEMINAR ON 400 KV GSS(RRVPNL) BIKANER.
Submitted To:- Submitted By:- Mr.
Disconnector Switches and Earth Switches
HIGH VOLTAGE UNION Vacuum Circuit Breaker 110 kV VRS-110 Series ВЫСОКОВОЛЬТНЫЙ СОЮЗ
Presentation Topic: Circuit Breakers Represented to: Dr. M. Riaz Khan Represented by: M. Mujahid.
This project on Primary sub station of Visakhapatnam port trust at Visakhapatnam. It is 132kv/11kv substation with incoming feeder from APTransco and 11.
5SL4 10 kA / 5SL6 6 kA miniature circuit breakers
HVDC Transmission.
EE 2353 HIGH VOLTAGE ENGINEERING
SYNERGY INSTITUTE OF ENGINEERING AND TECHNOLOGY
6 Week industrial Training Presentation
STUDY OF ELEMENTS OF A 220/132/33KV SUBSTATION
Comparison of AIS and GIS Grid Station Muhammad Ali Ashraf Management Associate (Electrical) CPP Project.
Sub Station.
v1/2011 Strikesorb Protection Solutions
SUB-STATIONS.
Chapter # 25 Sub-Stations risemark.pbworks.com.
3AH5 Vacuum Circuit-Breaker For Standard Applications
SINGLE LINE DIAGRAM.
PRESENTATION ON SUMMER TRAINING PROGRAM
Basics of electrical engineering
Circuit Breakers & Reclosers
3AH5 Vacuum Circuit-Breaker For Standard Applications
EHV Transmission Equipments
All rights reserved Gas-insulated Switchgear (GIS)
NOTICE The size of display board is 1m (width)×2.40m(height). A size 0.95m (width)×1.40m(height) of your poster is recommend. In the poster, please edit.
3AH5 Vacuum Circuit-Breaker For Standard Applications
CIRCUIT BREAKERS E. Chikuni. Circuit Breakers Mechanical Switches capable of making and breaking currents under normal circuit conditions and for a specified.
Biosco: MV/LV prefabricated substations IEC Presentation of the standard Safety is a choice.
Substation Equipment's
Presentation transcript:

1200 kV AC Substations - Products and Integrated Solutions International UHV Symposium New Delhi, 29. January 2009 Edelhard Kynast Siemens AG, Energy

1200 kV AC Substation Basic requirements - Example: PGCIL Electrical Requirements Rated voltage 1200 kV Rated current, feeder 5000 A Rated frequency 50 Hz Short-circuit current 50 kA / 1 s Rated lightning impulse withstand voltage 2400 kV Rated switching impulse withstand voltage 1800 kV Creepage distance 25 mm/kV (Total 30000 mm) Environmental conditions Temperature (min / average / max) +4 ºC / 38 ºC / 50 ºC Seismic Zone 1 Wind 47 m/s Altitude <1000 m

1200 kV AC Substation Basic requirements - Example: PGCIL Minimum Clearances Minimum clearance phase to earth 8300 mm Minimum clearance phase to phase 11600 mm (According to draft „IEC 60071-1 Amd.1 Ed. 8.0, 2008-05-16“) Lowest part of insulation 3500 mm Min. height lowest live part 18000 mm Working clearance 18000 mm AIS is PGCIL preferred technology Assumed distances Bay distances Phase to phase distance 20000 mm Bay width 62000 mm Three live part levels Height of lower conductor level 18000 mm Height of busbar 36000 mm Height of long spans 55000 mm

1200 kV AC Substation Circuit Configurations 1 ½ Breaker Configuration 2 Breaker Configuration Recommended solution: Double Busbar Configuration Arrangement is simple and clear Acceptable costs Unrestricted and non-stop operation of all feeders in 2 groups Busbar maintenance without interruption of power supply more

1200 kV AC Substation Double Busbar arrangement - Layout

1200 kV AC Substation Double Busbar Arrangement - Layout - Surge Arresters Disconnectors Dead Tank Circuit Breakers Current Transformers Capacitive Voltage Transformers

1200 kV AC Surge Arresters Development Based on 800 kV DC-Application 5 unit surge arrester with grading and corona ring Active part with four columns in parallel Additional cooling with aluminum blocks between MO varistors 800 kV DC Design

1200 kV AC Surge Arresters Technical Data Designation 3EQ5 850-5PT95 Rated voltage 850 kV Continuous operating voltage 723 kV Nominal discharge current 20 kA Lightning impulse protection level 1700 kV Switching impulse protection level 1500 kV Energy discharge capability 55 MJ Creepage distance 35750 mm (30 mm/kV) Height 12 m Bending moment 150 kNm Voltage-current characteristic of a MO surge arrester for 1200 kV AC power system

1200 kV AC Disconnector - Project Powergrid India Recommendation for Double Side Break Design Double Side Break design advantages for 1200 kV AC application - high reliability due to the reduced number of moving parts in the kinematic chain and in the current path - well proven turn and twist design of the current path - space savings in the vertical dimension due to the current path movement only in the horizontal direction Experience in Double Side Break Disconnectors for UHV application - Double side break ZBF 800 kV AC in service in Ucraine - Double side break ZBF 515 kV DC in service in China - Double side break ZBF 824 kV DC installation in China

Technical parameters 1200 kV AC disconnector & earthing switch 1200 kV AC Disconnector Specified Requirements - Project Powergrid India Technical parameters 1200 kV AC disconnector & earthing switch Rated voltage 1200 kV Frequency 50 Hz  Normal current 6000 Amps Short time withstand current 50 kA / 1 s Peak withstand current 125 kA Lightning impulse withstand voltage - phase- to- earth 2400 kV - across isolating distance 2400 kV+685 kV Switching impulse withstand voltage - phase- to- earth 1800 kV - across isolating distance 1800 kV + 980kV Creepage distance of insulators 25 mm/kV ZBF 824 kV DC, DoubleSideBreak Project Yun Guang, China

UHV - Circuit-Breaker 1200 kV Testing: Short circuit performance 8DR1-P5-1100 kV – 50 kA Test at KEMA, Arnhem , February / April 2008 T100a (February 2008) Full pole test Time constant 120 ms Value of last current loop 115 kA First pole to clear factor 1,3 p. u. TRV peak value 1600 kV Minimum arcing time 10,3 ms T10 (April 2008) First pole to clear factor 1,5 p. u. TRV peak value 2062 kV Minimum arcing time 5,1 ms

UHV - Circuit-Breaker 1200 kV Testing: Dielectric performance 8DR1-P5-1100 kV – 50 kA Prototype Test at FGH, Manheim , July / August 2008 Withstand voltage tests Lightning impulse voltage - phase to earth 2400 kV - across open cb 2400 + 630 kV Switching impulse voltage - phase to earth 1800 kV - across open cb 1675 + 900 kV Power-frequency voltage - phase to earth 1100 kV - across open cb 1180 + 320 kV

1200 kV AC Current Transformers Solutions: SF6 – Free-standing or Ring-core CB-solution Main parameters Rated voltage 1200 kV Rated current 5000 A Lightning impulse voltage 2400 kV Switching impulse voltage 1800 kV Power-frequency voltage 1215 kV Composite insulators Creeping distance 25 mm/kV Overall height 11,3 m Weight 4.240 kg Current Transformer Ring-core CB-solution

1200 kV AC Capacitive Voltage Transformer Requirements and Technical Data Main parameters Rated voltage 1200 kV Rated current 5000 A Lightning impulse voltage 2400 kV Switching impulse voltage 1800 kV Power-frequency voltage 1200 kV Capacitance 2000 pF Creeping distance 25 mm/kV Overall height 11,6 m Weight 2450 kg 1100kV CVT Prototype running in Wuhan UHV AC testing base

Solutions for 1200 kV AC Substations Conclusions UHV substations are important node-points in the power supply and distribution with a need of high reliability and high availability. Standards for the UHV level are under consideration, but not available today. The switchgear systems and equipment presented here for UHV are tailor made to the customers needs. A simple copying and scaling up from the system levels below is not always possible for the dimensions and parameters, but the basic knowledge of technologies and designs can be adapted from the experience with 800 kV DC systems and with 800 kV and 1100 kV AC systems.

Thank you, for your attention International UHV Symposium New Delhi, 29. January 2009

Circuit Configurations Arrangement is simple and clear Acceptable costs Busbar maintance with shut down of the feeders Unrestricted and non-stop operation of all feeders in 2 groups 2 BB – Double Busbar Configuration

Circuit Configurations Circuit scheme and arrangement not clear Expensive design High availability Selective Fault clearing with interuption of operation, if both busbars under operation 1 ½ Breaker Configuration

Circuit Configurations Expensive design High availability Selective Fault clearing with interuption of operation 2 Breaker Configuration

1200 kV Circuit Configurations Comparison 2 Breaker Configuration 1 ½ Breaker Configuration Double Busbar Configuration Arrangement Clear arrangement High space requirement because of double number of CB and DS Arrangement not so clear Higher space requirement due to 3rd CB per 2 feeder Arrangement is simple and clear Acceptable space requirement Operation Highest availability Uninterrupted supply by failing of 1 busbar Uninterrupted supply during CB maintenance High availability for radial circuit, only few meshes Uninterrupted supply by failing of 1 busbar High availability and flexibility for meshed networks Uninterrupted supply by failing of 1 busbar with coupler bay Interrupted power supply during maintenance of CB Cost Expensive design Redundancy of CB and related DS per bay Additional CB per diameter Busbar current = bay current Acceptable costs