NRUCFC Headquarters Building Sterling, VA Architectural Engineering Senior Thesis Margaret McNamara | Mechanical Option Advisor | Dr. Stephen Treado.

Slides:



Advertisements
Similar presentations
DOUG BOSWELL MECHANICAL OPTION APRIL 16, 2008 Temple University Tyler School of Art.
Advertisements

Kevin Edstrom Mechanical Option 2011 Senior Thesis April 12 th, 2011 Georgetown University New Science Center Washington, DC.
Chilled Beam Presentation
The Hearst Tower 959 Eighth Avenue New York, NY
STEM Center Delaware County Community College – Media, PA Thesis Final Presentation Dan Saxton Mechanical Option.
The Medical Office Building Brendon Burley Structural Option April 11, 2005 Advisor: Dr. Thomas Boothby.
West Virginia University Alumni Center Gregory Smithmyer | Mechanical Option | Penn State University | April 15, 2009 | Advisor: Dr. Srebric.
Jacksonville, FL The Pennsylvania State University Department of Architectural Engineering Zachary Polovchik Mechanical Option Advisor – Dustin Eplee Duval.
WESTINGHOUSE ELECTRIC NUCLEAR ENGINEERING HEADQUARTERS DANIEL AUGHENBAUGH - MECHANICAL OPTION Westinghouse Nuclear Engineering Headquarters Daniel Aughenbaugh.
Coppin State University Physical Education Complex Kaylee Damico – Mechanical Option April 12 th, 2011 Presentation Outline Project Team Project Overview.
Presentation Outline Introduction CHP Analysis Electrical Analysis Acoustical Analysis Thermal Storage Analysis System Optimization Analysis Conclusion.
Integration of Mechanical System Redesign Geothermal Heat Pump Redesign Wesley S. Lawson Architectural Engineering Mechanical Option Pennsylvania State.
Building Systems Integration - Energy and Cost Analysis The Milton Hershey School New Supply Center Justin Bem AE Senior Thesis – Spring 2007 Mechanical.
Bowie State University Fine and Performing Arts Center Zachary Lippert Faculty Advisor: Dr. Stephen Treado.
The Edward St. John Student Center Zachary Haupt Faculty Advisor: Dr. William Bahnfleth 11 April 2011.
North Pocono High School
Technology and Engineering Development (TED) Building Thomas Jefferson National Accelerator Facility Newport News, VA David Blum | Mechanical Option Dustin.
Rebecca S. Allen THE PALESTRA BUILDING Optimizing Energy Efficiency of the Palestra Building London, England.
CENTRAL HIGH SCHOOL Central High School MID-ATLANTIC REGION ADAM BROWN MECHANICAL OPTION SPRING 2014 Introduction Existing Mechanical System Thesis Proposal.
Presentation Outline Introduction System Optimization Analysis Acoustical Breadth Conclusion Acknowledgements Questions Thesis Final Presentation Army.
National Institutes of Health Building 37 Modernization Katie L. McGimpsey Mechanical Option The Pennsylvania State University Department of Architectural.
The New RLPS Architects Office Building Lancaster, PA Brice Ohl – Mechanical Option Presented on 4/10/13.
SENIOR THESIS PRESENTATION
Energy Efficient System Design: Geothermal System Coupled with Chilled Beams and DOAS Montgomery College New Science Center.
City of Hope Amini Medical Center Christopher Bratz Pennsylvania State University Architectural Engineering Mechanical Option Faculty Advisor: Dr. Jelena.
Kennedy Krieger Institute Outpatient Medical Center Baltimore, Marylan d Katie Sennett Construction Management Dr. Messner Spring 2008.
Nate Mooney | Mechanical Option Advisor: William P. Bahnfleth, PH.D., PE The Pennsylvania State University Architectural Engineering Spring Ames.
Architectural Engineering Mechanical Option Ft. Detrick Defense Medical Logistics Center Building Systems Redesign April 16, 2008 Senior Thesis Presentation.
Senior Thesis 2013 Ji Won Park Mechanical Option Advisor: Dr. Stephen Treado.
Ray & Joan Kroc Corps Community Center Mathias Kehoe | Mechanical Option April 09, 2012.
Army Reserve Center Newport, Rhode Island Alexander Hosko Mechanical Option.
UNIFIED SCIENCE CENTER THE UNIVERSITY OF SCRANTON SCRANTON, PA DALE E. HOUCK MECHANICAL OPTION.
Paul Roberts Senior Thesis 2010 Construction Management.
Caitlin Ferrell Structural Option Senior Thesis Presentation Spring 2006 The Erie Convention Center and Sheraton Hotel Erie, Pennsylvania Architectural.
Bronx School for Law Government & Justice Yulien Wong Mechanical Option 2006 Senior Thesis Bronx, New York.
Tri-Valley Jr./Sr. High School Hegins, PA Senior Thesis, Spring 2004 Studying The Feasibility of a Dedicated Outdoor Air System.
Architectural Engineering Senior Thesis Mechanical System Redesign Saint Joseph Medical Center Chris Nicolais.
Spring 2007 Senior Thesis Justin D. Schultz Mechanical Option The Hauptman-Woodward Medical Research Institute Dedicated Outdoor Air Applications at the.
APPELL LIFE SCIENCES York College of Pennsylvania Joshua Martz | Dr. Srebric | April 11, 2011 Image Courtesy of RLPS, Ltd.
University of Maryland’s Gossett Field House College Park, MD Jason Borowski Architectural Engineering Mechanical Option Pennsylvania State University.
The Sunshine Elementary School Redesign Proposal Pennsylvania State University AE Senior Thesis Nicholas Scheib Mechanical Option- IP.
Jonathon Gridley Senior Thesis – Spring 2007 Mechanical Option Energy Efficient Mechanical System Alternatives South Jefferson High School S OUTH J EFFERSON.
Greenbriar East Elementary School Fairfax, Virginia Michelle L. Siano Mechanical Option Spring 2005 Senior Thesis.
Straumann USA 60 Minuteman Road Andover, MA Kevin Kaufman Mechanical Option The Pennsylvania State University Architectural Engineering.
SteelStacks Performing Arts Center Sarah Bednarcik | Structural BAE/MAE Faculty Advisors: Dr. Linda Hanagan & Dr. Ali Memari Spring Thesis 2013Bethlehem,
Building Systems Integration - Energy and Cost Analysis The Milton Hershey School New Supply Center Justin Bem AE Senior Thesis – Spring 2007 Mechanical.
INOVA Fairfax Hospital South Patient Tower Falls Church, VA Senior Thesis 2012 Mike Morder Mechanical Option Advisor: Dr. William Bahnfleth.
Flood Athletic Center Woong June Chung Penn State University Mechanical Option Thesis Advisor : DR. Willam Bahnfleth, P.E.
Malory J. Faust ∙ Mechanical Option ∙ Senior Thesis 2007.
Twin Rivers Elementary/Intermediate of McKeesport Area School District Tessa Bauman Mechanical Option Technical Consultant: Laura Miller 1600 Cornell St.,
Britt Kern Mechanical Option Advisor: Dr. Treado Hunter’s Point South School Queens, New York.
Jesse A. Fisher Mechanical Option Spring 2005 Riverpark Corporate Center, Phase 1 Salt Lake City, Utah.
Hamot Women’s Hospital Erie, PA Michael Galleher Mechanical Option l AE-Senior Thesis l April 12, 2011 l Advisor Dr. Jelena Srebric.
The School District of Philadelphia Administration Headquarters Shell and Core Renovations 440 North Broad Street Philadelphia, PA Jayme Antolik Architectural.
The New Student Housing Building at The Mount St. Mary’s University Emmitsburg, Maryland Erik Shearer Mechanical Option Advisor: Dr. Srebric Spring 2007.
Alexander Radkoff Mechanical Option | Spring 2014 Advisor: Dr. Stephen Treado 123 Alpha Drive Pittsburgh, Pennsylvania
New Castle Center for Delaware Hospice, Inc Zachary Klixbull Penn State University – Architectural Engineering Mechanical Option Advisor: Professor Bahnfleth.
Manoa Elementary School Amanda Cronauer Faculty Advisor: Dr. William Bahnfleth 14 April 2010.
Michael Reilly, Jr. – Mechanical Option Advisor – James Freihaut, PhD & Dustin Eplee The Pennsylvania State University Nassau Community College Life Sciences.
ENVIROCENTER PHASE II JESSUP, MD
David Anderson Mechanical Option
Grunenwald Science and Technology Building
Acterna Headquarters John M Sekel, EIT Germantown, Maryland
Munters DOAS, Chilled Beams and VRV
Biobehavioral Health Building, University Park, PA
LONGWOOD AT OAKMONT HEALTHCARE CENTER
The Ed Roberts Campus Berkeley, CA Introduction Existing Systems
Feasibility of Ice Storage
Senior Thesis Presentation
Virtua Replacement Hospital -Voorhees NJ
Presentation transcript:

NRUCFC Headquarters Building Sterling, VA Architectural Engineering Senior Thesis Margaret McNamara | Mechanical Option Advisor | Dr. Stephen Treado

Project Overview Systems Overview Existing Mech. System Depth 1Depth 2Breadth 1 Acknowledgements NRUCFC Headquarters Building | Margaret McNamara | Mechanical | Advisor Dr. Stephen Treado Introduction Project Overview Systems Overview Existing Mechanical System Depth1 | DOAS w. Chilled Beams Depth 2 | Hybrid PVT Solar System Breadth 1 | Electrical Breadth 2 | Architectural Conclusion Acknowledgements Questions ConclusionQuestions

Project Overview Systems Overview Existing Mech. System Depth 1Depth 2Breadth 1 Acknowledgements NRUCFC Headquarters Building | Margaret McNamara | Mechanical | Advisor Dr. Stephen Treado Introduction Project Overview Systems Overview Existing Mechanical System Depth1 | DOAS w. Chilled Beams Depth 2 | Hybrid PVT Solar System Breadth 1 | Electrical Breadth 2 | Architectural Conclusion Acknowledgements Questions ConclusionQuestions

Project Overview Systems Overview Existing Mech. System Depth 1Depth 2Breadth 1 Acknowledgements NRUCFC Headquarters Building | Margaret McNamara | Mechanical | Advisor Dr. Stephen Treado Introduction Project Overview Systems Overview Existing Mechanical System Depth1 | DOAS w. Chilled Beams Depth 2 | Hybrid PVT Solar System Breadth 1 | Electrical Breadth 2 | Architectural Conclusion Acknowledgements Questions ConclusionQuestions

Project Overview Systems Overview Existing Mech. System Depth 1Depth 2Breadth 1 Acknowledgements NRUCFC Headquarters Building | Margaret McNamara | Mechanical | Advisor Dr. Stephen Treado Introduction Project Overview Systems Overview Existing Mechanical System Depth1 | DOAS w. Chilled Beams Depth 2 | Hybrid PVT Solar System Breadth 1 | Electrical Breadth 2 | Architectural Conclusion Acknowledgements Questions ConclusionQuestions

Project Overview Systems Overview Existing Mech. System Depth 1Depth 2Breadth 1 Acknowledgements NRUCFC Headquarters Building | Margaret McNamara | Mechanical | Advisor Dr. Stephen Treado Introduction Project Overview Systems Overview Existing Mechanical System Depth1 | DOAS w. Chilled Beams Depth 2 | Hybrid PVT Solar System Breadth 1 | Electrical Breadth 2 | Architectural Conclusion Acknowledgements Questions ConclusionQuestions

Project Overview Systems Overview Existing Mech. System Depth 1Depth 2Breadth 1 Acknowledgements NRUCFC Headquarters Building | Margaret McNamara | Mechanical | Advisor Dr. Stephen Treado Introduction Project Overview Systems Overview Existing Mechanical System Depth1 | DOAS w. Chilled Beams Depth 2 | Hybrid PVT Solar System Breadth 1 | Electrical Breadth 2 | Architectural Conclusion Acknowledgements Questions ConclusionQuestions

Project Overview Systems Overview Existing Mech. System Depth 1Depth 2Breadth 1 Acknowledgements NRUCFC Headquarters Building | Margaret McNamara | Mechanical | Advisor Dr. Stephen Treado Introduction Project Overview Systems Overview Existing Mechanical System Depth1 | DOAS w. Chilled Beams Depth 2 | Hybrid PVT Solar System Breadth 1 | Electrical Breadth 2 | Architectural Conclusion Acknowledgements Questions ConclusionQuestions

Project Overview Systems Overview Existing Mech. System Depth 1Depth 2Breadth 1 Acknowledgements NRUCFC Headquarters Building | Margaret McNamara | Mechanical | Advisor Dr. Stephen Treado Introduction Project Overview Systems Overview Existing Mechanical System Depth1 | DOAS w. Chilled Beams Depth 2 | Hybrid PVT Solar System Breadth 1 | Electrical Breadth 2 | Architectural Conclusion Acknowledgements Questions ConclusionQuestions

Project Overview Systems Overview Existing Mech. System Depth 1Depth 2Breadth 1 Acknowledgements NRUCFC Headquarters Building | Margaret McNamara | Mechanical | Advisor Dr. Stephen Treado Introduction Project Overview Systems Overview Existing Mechanical System Depth1 | DOAS w. Chilled Beams Depth 2 | Hybrid PVT Solar System Breadth 1 | Electrical Breadth 2 | Architectural Conclusion Acknowledgements Questions ConclusionQuestions

Project Overview Systems Overview Existing Mech. System Depth 1Depth 2Breadth 1 Acknowledgements NRUCFC Headquarters Building | Margaret McNamara | Mechanical | Advisor Dr. Stephen Treado Introduction Project Overview Systems Overview Existing Mechanical System Depth1 | DOAS w. Chilled Beams Depth 2 | Hybrid PVT Solar System Breadth 1 | Electrical Breadth 2 | Architectural Conclusion Acknowledgements Questions ConclusionQuestions

NRUCFC Headquarters Building | Margaret McNamara | Mechanical | Advisor Dr. Stephen Treado Project Overview Location | Sterling, VA Project Overview Building Type | Office Building Size | 120,000 GSF Number of Stories | 3 above grade Construction Dates | Nov Sept Project Cost | $45 million Project Delivery Method | Design-Bid-Build Project Overview Systems Overview Existing Mech. System Depth 1Depth 2Breadth 1 Acknowledgements Project Team Architect | Kishimoto.Gordon.Dalaya PC Interior Architect | Fox Architects Landscape Architect | EDAW Site/Civil Engineers | Dewberry Structural Engineers | SK&A MEP Engineers | WSP Flack + Kurtz LEED Consultants | Sustainable Design Cunsulting General Contractor | Whiting-Turner N ConclusionQuestions

Architecture Structural System Foundation| Combination of isolated columns and strip wall footings with a 5” slab-on grade Frame | Steel Frame that utilizes composite beams and slabs Atrium | Arched trusses made of HSS members form atrium dome with an oculus Project Overview Systems Overview Existing Mech. System Depth 1Depth 2Breadth 1 Acknowledgements NRUCFC Headquarters Building | Margaret McNamara | Mechanical | Advisor Dr. Stephen Treado ConclusionQuestions Electrical/Lighting System Generators | Two pad-mounted 600kW generators serve emergency power and required standby service Microturbines | Two 65 kW microturbines serve data center Lighting | Daylight sensors and occupancy sensors control the lighting

Water Side Summary Cooling | Two 210 ton electric centrifugal chillers located in first floor central plant Heating | Two high efficiency natural gas boilers located in the penthouse Project Overview Systems Overview Existing Mech. System Depth 1Depth 2Breadth 1 Acknowledgements Air Side Summary Four Rooftop AHUs | 18,000-24, 000 CFM Fan Powered Boxes | Perimeter Heating and Cooling VAV Boxes | Interior Heating and Cooling NRUCFC Headquarters Building | Margaret McNamara | Mechanical | Advisor Dr. Stephen Treado ConclusionQuestions Atrium Heating and Cooling Ground Source Heat Pumps Radiant Flooring

Active Chilled Beams Advantages Uses less air and allows for smaller duct work and AHUs Lower floor to floor height Requires minimum maintenance Reduces energy consumption Active Chilled Beam Disadvantages Higher initial cost Larger than tradition diffuser Sensitive to humidity Project Overview Systems Overview Existing Mech. System Depth 1Depth 2Breadth 1 Acknowledgements Depth 1 | DOAS with Chilled Beams Redesign Proposal Replace four existing AHUs with DOAS unit Replace VAVs and FPBs with Chilled Beams NRUCFC Headquarters Building | Margaret McNamara | Mechanical | Advisor Dr. Stephen Treado Redesign Goal Reduce energy consumption Reduce airflow Active Chilled Beams (ACBs) ConclusionQuestions

Project Overview Systems Overview Existing Mech. System Depth 1Depth 2Breadth 1 Acknowledgements DOAS w. ACBs Design Conditions NRUCFC Headquarters Building | Margaret McNamara | Mechanical | Advisor Dr. Stephen Treado Supply AirOutdoor Air Space Design T DB (F˚) Humidity (Grains) Dew Point (F˚)45-- ModelQuantityLengthTotal Cost IQIC-4854’$ 72, IQIC-6986’$ 93, IQIC-8688’$ 71, Total251$ 236, Chilled Beam Summary Chilled Beam Sizing and Selection Latent and Sensible Load from TraneTRACE ASHRAE Standard 62.1 | Ventilation Requirements Ventilation Requirements to meet Latent Load ExSel Air Chilled Beam Calculator Depth 1 | DOAS with Chilled Beams ConclusionQuestions SEMCO IQID Series CHW Supply | 57 ˚F | 1 gpm

Project Overview Systems Overview Existing Mech. System Depth 1Depth 2Breadth 1 Acknowledgements DOAS Unit Selection 40,000 CFM NRUCFC Headquarters Building | Margaret McNamara | Mechanical | Advisor Dr. Stephen Treado SEMCO Pinnacle System (PVS) Depth 1 | DOAS with Chilled Beams ConclusionQuestions PVS Advantages Total Energy Wheel & Passive Dehumidification Wheel Delivers low dew points Provides high levels of OA and controls humidity Large latent load capacity

Project Overview Systems Overview Existing Mech. System Depth 1Depth 2Breadth 1 Acknowledgements NRUCFC Headquarters Building | Margaret McNamara | Mechanical | Advisor Dr. Stephen Treado PVS Heating Mode PVS Unoccupied Mode PVS Cooling Mode Depth 1 | DOAS with Chilled Beams ConclusionQuestions

Project Overview Systems Overview Existing Mech. System Depth 1Depth 2Breadth 1 Acknowledgements NRUCFC Headquarters Building | Margaret McNamara | Mechanical | Advisor Dr. Stephen Treado First Cost Comparison Depth 1 | DOAS with Chilled Beams ConclusionQuestions Energy Consumption Comparison Existing System QuantityItemEquipmentInstallationTotal 132VAV/FPB Boxes $ 56, $ 24, $ 81, AHUs $ 700, $ 48, $ 748, Total $ 748, Redesigned System 251Chilled Beams $ 236, $ 32, $ 269, Pinnacle DOAS Unit $ 278, $ 18, $ 296, Total $ 566, First Cost Savings$ 181, Utility Cost Savings$ 24, Total$ 206, Cost Savings

Redesign Proposal and Goals Add hybrid PVT Collectors to the roof Produce heat and electricity from solar radiation Project Overview Systems Overview Existing Mech. System Depth 1Depth 2Breadth 1 Acknowledgements NRUCFC Headquarters Building | Margaret McNamara | Mechanical | Advisor Dr. Stephen Treado Depth 2 | Hybrid Photovoltaic/Thermal (PVT) Solar System ConclusionQuestions Advantages More efficient than traditional PV modules One unit instead of two | Installation, Materials, Energy PVTWINS Schematic Liquid Collector Disadvantages Not used frequently Costly and little to no incentives

Design Information # of Collectors | 10 Collectors Area | 6.4 m 2 each collector Tilt | 40˚ Project Overview Systems Overview Existing Mech. System Depth 1Depth 2Breadth 1 Acknowledgements NRUCFC Headquarters Building | Margaret McNamara | Mechanical | Advisor Dr. Stephen Treado Depth 2 | Hybrid Photovoltaic/Thermal (PVT) Solar System ConclusionQuestions PVTWIN Series 1025 | PVT Liquid Collector Month Solar Radiation (kWh/m 2 /day) Energy Output (kWh) ThermsCost January $ February $ March $ April $ May $ June $ July $ August $ September $ October $ November $ December $ Total Savings$ 2, Solar Thermal Energy Output Total Solar Thermal Savings | $2,911.66

Cost Summary Total Collector Cost | $98,350 Total PVT Savings | $7,544 Simple Payback | 13 Years Project Overview Systems Overview Existing Mech. System Depth 1Depth 2Breadth 1 Acknowledgements NRUCFC Headquarters Building | Margaret McNamara | Mechanical | Advisor Dr. Stephen Treado Depth 2 | Hybrid Photovoltaic/Thermal (PVT) Solar System ConclusionQuestions PVTWIN Series 1025 | PVT Liquid Collector Month Solar Radiation (kWh/m 2 /day) Energy Output (kWh) ThermsCost January $ February $ March $ April $ May $ June $ July $ August $ September $ October $ November $ December $ Total Savings$ 2, Solar Thermal Energy Output Total Solar Thermal Savings | $2,911.66

Redesign Goals Condense Panel Boards | Remove FPBs Electrical Production of PVT Collectors Condense Panel Boards Project Overview Systems Overview Existing Mech. System Depth 1Depth 2Breadth 1 Acknowledgements NRUCFC Headquarters Building | Margaret McNamara | Mechanical | Advisor Dr. Stephen Treado Breadth 1 | Electrical ConclusionQuestions New Feeder Size (4) #4 + (1) #8 G. in 1-1/4” C. [Type THHN/THWN]

Redesign Goals Condense Panel Boards | Remove FPBs Electrical Production of PVT Collectors PVT Collector Electric Energy Output Project Overview Systems Overview Existing Mech. System Depth 1Depth 2Breadth 1 Acknowledgements NRUCFC Headquarters Building | Margaret McNamara | Mechanical | Advisor Dr. Stephen Treado Breadth 1 | Electrical ConclusionQuestions Month Solar Radiation (kWh/m 2 /day) AC Energy (kWh) Energy Value ($) January3.594,164$ February4.284,370$ March4.805,278$ April5.345,457$ May5.325,328$ June5.665,495$ July5.465,354$ August4.385,369$ September5.075,004$ October4.724,967$ November3.563,767$ December3.033,354$ Total57,907$ 4, PV Schematic

Depth 1 | DOAS w. Chilled Beams Total Savings | $206, Simple Payback | 4 years Recommendations Project Overview Systems Overview Existing Mech. System Depth 1Depth 2Breadth 1 Acknowledgements NRUCFC Headquarters Building | Margaret McNamara | Mechanical | Advisor Dr. Stephen Treado Conclusion Questions Depth 2 | Hybrid PVT Solar System Total Savings | $7, Simple Payback | 13 years Recommendations

Project Overview Systems Overview Existing Mech. System Depth 1Depth 2Breadth 1 ConclusionAcknowledgementsQuestions NRUCFC Headquarters Building | Margaret McNamara | Mechanical | Advisor Dr. Stephen Treado Acknowledgements Penn State University Architectural Engineering Faculty Dr. Stephen Treado | Thesis Advisor Robert Holland | Course Coordinators M. Kevin Parfitt | Course Coordinators National Rural Utilities Cooperative Finance Corporation John L. Moone CPM, CFM Industry Professionals Darren Bruce, PE, LEED AP BD+C | Sebesta Blomberg Trevor Boz, LEED AP | WSP Flack+Kurtz Alexandra Parris | KGD Architecture Penn State AE Class of 2012 Friends & Family

Project Overview Systems Overview Existing Mech. System Depth 1Depth 2Breadth 1 Acknowledgements NRUCFC Headquarters Building | Margaret McNamara | Mechanical | Advisor Dr. Stephen Treado Thank you! Questions? ConclusionQuestions