Light Output Uniformity of Long CsI(Tl) crystals - the “bottle-neck” for gamma and proton spectroscopy Light Output Uniformity for CsI(Tl) as supplied.

Slides:



Advertisements
Similar presentations
Topic 8. Gamma Camera (II)
Advertisements

Dror Malka and Zeev Zalevsky
Recent news about SiPM based applications R&D in DESY Nicola D’Ascenzo University of Hamburg - DESY.
JYFLTRAP: Spectroscopy with multi-trap facility Facility Mass purified beams In-trap spectroscopy Future plans.
Hybrid Detector Array ( ) The RIKEN-ATOMKI hybrid array Gábor Kalinka (ATOMKI, Debrecen) 3rd Japan-Hungary Joint Seminar on Physics in Modern Science.
Prototype of the Daya Bay Neutrino Detector Wang Zhimin IHEP, Daya Bay.
Geant4 simulations for the calorimeter prototypes D. Di Julio, J. Cederkäll, P. Golubev, B. Jakobsson Lund University, Lund, Sweden.
Physics 121: Electricity & Magnetism – Lecture 5 Electric Potential Dale E. Gary Wenda Cao NJIT Physics Department.
Fiberless Coupled Tiles for a High Granularity Scintillator-SiPM Calorimeter Rick Salcido Northern Illinois University November 14, 2009 Prairie Section.
Proton test facilities Uppsala, TSL, GWC, B-line (Blue hall): Energy ±0.80 MeV. Flux reduced from normal 2·10 8 s -1 to 900 s -1 with a profile as.
Geant4 simulations for the calorimeter prototypes D. Di Julio, J. Cederkäll, P. Golubev, B. Jakobsson Lund University, Lund, Sweden.
Tests of scintillators CsI, CsI(Na), BGO, NaI(Tl) CsI(Tl)
Observation of Fast Scintillation of Cryogenic PbI 2 with VLPCs William W. Moses, 1* W.- Seng Choong, 1 Stephen E. Derenzo, 1 Alan D. Bross, 2 Robert Dysert,
ipno.in2p3.fr Milano - October 2006IPNO-RDD-Jean Peyré1 Measurements of CsI(Tl) Crystals with PMT and APD Jean Peyré Milano - Oct 2006.
R&D on CsI(Tl) + APD Optimisation of the energy resolution M. Gascón I.Durán.
Crystals !? R3B/EXL meeting Milan Oct-06. Crystal growing factories Quality and price on 20(23)*20(23)*110 mm 3 detector light output uniformity* price.
Proportional Counters
INFN of Genova, Pavia and Roma Flavio Gatti, PSI, February 9 th, Timing Counter status Timing Counter status.
GEANT4 simulations for the Lund R 3 B prototype Douglas Di Julio Lund University, Lund, Sweden.
Nustar/crystal simulations B. Genolini Crystal: CsI(Tl) (Saint Gobain), wrapped with reflector (VM2000, Tyveck?) Geometry:
Especially concerning optimization of identification power, energy resolution, efficiency, optimal readout device for the barrel part of CALIFA, a calorimeter.
Status of the Calorimeter Working group activities GSI, 16 th October 2007.
What the Lund/Dubna group wishes to achieve until next annual meeting produce two* close-to-final (forward) EGPA clusters requiresCsI(Tl) decided (alternatives?,doping.
B. Jakobsson, CWG meeting, June 18-19, 2007: Intoductory slide
Uniformity Test of Diffuser Shahab Khan & Peter Torres UIC.
ipno.in2p3.fr Orsay - October 2007IPNO-RDD-Jean Peyré1 Test Protocole for Crystals with Gamma Sources Jean Peyré Oct 2007.
ipno.in2p3.fr Lund - June 2007IPNO-RDD-Jean Peyré1 Measurements of some Crystals with PMT R&D on Calorimeters Jean Peyré Lund - June 2007.
Ideas on VFEE I. Durán Universidad de Santiago de Compostela NUSTAR Calorimeter WG Valencia, June 2005.
H. Alvarez Pol - NUSTAR Calorimeter WG R3B/EXL Collaboration Meeting - Santiago Sept Geometrical design, simulation progress and first detector.
B W Kennedy, CCLRC Rutherford Appleton Laboratory VPTs for the CMS experiment B W Kennedy CCLRC Rutherford Appleton Laboratory St Petersburg, 26 April.
Trend ground array 1 1.General considerations 2.Study on the prototype detector 3.Inclined ground array simulation 4.Making work plan in 2014.
1 Light Collection  Once light is produced in a scintillator it must collected, transported, and coupled to some device that can convert it into an electrical.
Photon detection Visible or near-visible wavelengths
Absolute light output determination of crystal scintillators
Realistic requirements from R 3 B program  In-beam tests of Demonstrators (no TRD yet) Decisions on: Readout device, Forward cap detectors (  Detector.
PPARC forum on developments in scintillator technology R M Brown - RAL 1 Scintillating Crystals for Particle Physics Outline  Performance considerations.
EXL/crystal simulations B. Genolini Simulation of NUSTAR crystals with Litrani Presentation of Litrani: simulation of.
DSSD – Si, 300 mkm, 1.85 mm pitch, 59.5x59.5 mm**2. CsI(Tl)/PD, 20x20(front)23x23(back)x100mm**3. Produced by St.Gobain, Khar’kov and China Companies PD.
1 Alessandra Casale Università degli Studi di Genova INFN Sezione Genova FT-Cal Prototype Simulations.
Photo-detector and scintillator studies at ITEP Outline 1. Check of casting form 2. Study of MRS APD’s from CPTA 3. MC simulation of light collection in.

Physics 1D03 Version number J. P. Student Multiple-choice answer sheets: HB pencil only; ink will not work Fill circle completely No extra marks.
Experimental set-up for on the bench tests Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE/Photonis Multi-Channel.
Scintillator tile-SiPM system development for CALICE Engineering AHCAL Prototype Michael Danilov, ITEP & CALICE LCWS10 Beijing March 2010 Outline New scintillator.
Design and optimization of Electromagnetic particle Detectors (EDs) in LHAASO-KM2A Xiangdong Sheng, Jia Liu, Jing Zhao on behalf of the LHAASO collaboration.
1 SiPM Gain Test SiPM Multiple APD pixels operating at Geiger mode. Output is the sum of the outputs from all APD pixels. Advantages Compact size High.
Hyper-Kamiokande project and R&D status Hyper-K project Motivation Detector Physics potential study photo-sensor development Summary Kamioka.
Synopsis of Yang/Wang’s Analysis and Optimization on Single-Zone Binary Flat-Top Beam Shaper Blake Anderton Mon, Dec
KEN, JERI FU JEN CATHOLIC UNIVERSITY 2008/DEC./11 1 Testing Status of P.P. & APD.
LHC The Large Hadron Collider (LHC) is an accelerator with 27 km circumference. Being built on the France- Switzerland border west of Geneva. It will start.
1/10/2016Collaboration Meeting Feb 2011 Start Counter 1 Start Counter Update W. U. Boeglin L. Guo E. Pooser Measurements on EJ-212 scintillator bars Attenuation.
Warm-Up #1 11/30 1. Write down these 3 formulas:
Gain stability and the LYSO beam radiation monitor measurements
Scintillators suitable for PET applications must be characterized by a high efficiency for gamma-ray detection, determined by a high density and atomic.
Avalanche Photodiodes from the Start.
Performance of Scintillator-Strip Electromagnetic Calorimeter for the ILC experiment Satoru Uozumi (Kobe University) for the CALICE collaboration Mar 12.
1 Simulation, Formatter & Analysis Kyo Tsukada Tohoku Univ.
Practice Problems A horizontal wire is moving vertically upwards in a horizontal magnetic field of strength tesla which is perpendicular to the.
Limitations on the Design of the CEDAR Light-guide Calculations of the light-collection efficiency indicate a severe limitation in the possible collection.
Ilhan TAPAN* and Fatma KOCAK
Solar gamma-ray and neutron registration capabilities of the GRIS instrument onboard the International Space Station Yu. A. Trofimov, Yu. D. Kotov, V.
A. F. Yanin, I. M. Dzaparova, E. A. Gorbacheva, A. N. Kurenya, V. B
Electric Potential Energy and Potential Difference
The Lund R3B prototype: In-beam proton tests and simulations
superB Detector Workshop I University of Perugia and INFN
Electrical Energy & Capacitance Pgs
Review 1+3= 4 7+3= = 5 7+4= = = 6 7+6= = = 7+7+7=
R&D of MPPC in kyoto M.taguchi.
Area Surface Area Volume
2. An ion accelerated through a potential difference of 115 V experiences an increase in kinetic energy of 7.37 × 10–17 J. Calculate the charge on the.
Presentation transcript:

Light Output Uniformity of Long CsI(Tl) crystals - the “bottle-neck” for gamma and proton spectroscopy Light Output Uniformity for CsI(Tl) as supplied by manufacturers… …and Energy Resolution for gammas, measured by a APD ( 5x5), when irradiating the whole crystal volume… * CsI(Tl), L=110 mm source 20x20 Lund-Dubna, VC_2007_12_13 L=110 mm

Effect of crystal Light Output nonuniformity ( a)- 5%, b)-10% on the Light collected by Photodetector. Calculated for Protons. For Gammas – the picture looks similar, but with energy scaled by factor 1/4 - 1/5. Conclusion – dLO/LO must be less than 1% along the length of crystal Straggling and Nonlinearity for Protons and Gammas due to dL/L Lund-Dubna, VC_2007_12_13

Test with highly uniform in Light Output Crystal, L=110 mm, dL/L <0.7% CsI(Tl) – 20x20 – 110 – 23x23 mm**3 Irradiated for 110 mm distance… Photodetectors: PD – 10x10 mm**2 APD – 5x5 mm**2 / =40 APD – 10x10 mm**2 / =50 Our data… compare APD of 5x5 and 10x10 mm**2 !!!! Published data, 10x10x10 mm**3 CsI(Tl)+ 10x10 APD !!! Lund-Dubna, VC_2007_12_13

a) b) Effect of VM200 ( ESR) Light Guide reflector on Light collection and Energy Resolution a)- Active area of APD = Active area of Light Guide, 10x10 mm**2. S_ APD /S_ LG =1.0 b)- Active area of APD = 0.25 of Active area of Light Guide, 5x5 mm**2. S_ APD /S_ LG =0.25 Light Collection coefficient, L(5x5)/L(10x10) = 0.65, due to the VM2000 (ESR) reflector, covering an extra surface By using an APD of 10x10 mm**2 we can gain around 12% in the energy resolution as compared with the APD of 5x5 mm**2 Lund-Dubna, VC_2007_12_13

Some Conclusions and Plans for Future R&D Lund-Dubna, VC_2007_12_13 1.Light Output uniformity for Long crystals is more important than the active area of the APD 2.For the highly uniform in L.O. crystals we can get almost ideal Energy Resolution 3.New groups must be involved in the Uniformity Problem for real Califa geometries Plans for nearest future: 1.Light Uniformity adjustment for the real CALIFA crystal geometry 2.Tests with APD’s, PMT’s / like R7400U-3, 20 – insensitive to magnetic field 3.To mount CsI(Tl) “demonstrator” for bench and in-beam tests