Methods Validation with Simulated Data 1.Generate random linear objects in the model coordinate system. 2.Generate a random set of points on each linear.

Slides:



Advertisements
Similar presentations
PLUS 2.0 Architecture Adam Rankin, Andras Lasso, Csaba Pinter, Tamas Ungi, and Gabor Fichtinger Laboratory for Percutaneous Surgery (Perk Lab) School of.
Advertisements

Intel Research Internet Coordinate Systems - 03/03/2004 Internet Coordinate Systems Marcelo Pias Intel Research Cambridge
Evaluation of Reconstruction Techniques
SlicerRT Image-guided radiation therapy research toolkit for 3D Slicer Csaba Pinter 1, Andras Lasso 1, An Wang 2, David Jaffray 2, and Gabor Fichtinger.
Improvements in SlicerRT, the radiation therapy research toolkit for 3D Slicer Csaba Pinter1, Andras Lasso1, An Wang2, David Jaffray2, and Gabor Fichtinger1.
Automatic determination of skeletal age from hand radiographs of children Image Science Institute Utrecht University C.A.Maas.
Treatment Planning of HIFU: Rigid Registration of MRI to Ultrasound Kidney Images Tara Yates 1, Penny Probert Smith 1, J. Alison Noble 1, Tom Leslie 2,
Using fCal for Freehand Ultrasound Calibration Csaba Pinter, Andras Lasso, Tamas Heffter, Tamas Ungi, Adam Rankin, and Gabor Fichtinger Laboratory for.
Hybrid Position-Based Visual Servoing
N-view factorization and bundle adjustment CMPUT 613.
Characterization of Ultrasound Elevation Beamwidth Artefacts for Brachytherapy Needle Insertion Mohammad Peikari Advisor: Dr. Gabor Fichtinger Laboratory.
Introduction Visual feedback mounted on surgical tool K. Carter, T. Vaughan, G. Gauvin, P. Pezeshki, A. Lasso, T. Ungi, E. Morin, J. Rudan, C. J. Engel,
Methodology Performance Estimate and Noise Modelling A baseline performance estimate was determined for a very low cost commercial MEMS-based IMU, the.
Volkan Cevher, Marco F. Duarte, and Richard G. Baraniuk European Signal Processing Conference 2008.
UC SANTA CRUZ, AUTONOMOUS SYSTEMS LAB Improved Orbit Estimation Using GPS Measurements for Conjunction Analysis Gabriel Hugh Elkaim, Assistant Professor.
NA-MIC National Alliance for Medical Image Computing Coming of age for a NA-MIC DBP Gabor Fichtinger, Andras Lasso, Tamas Ungi, Csaba.
3D full object reconstruction from kinect Yoni Choukroun Elie Semmel Advisor: Yonathan Afflalo.
Patient Specific 3D Surfaces for Interactive Medical Planning and Training Felix G. Hamza-Lup, Ph.D. Associate Professor Computer Science and Information.
M. Holden is funded by the ISCAS student travel scholarship. G. Fichtinger is funded as a Cancer Care Ontario Research Chair. Scalable ultrasound calibration.
Image Guided Surgery in Prostate Brachytherapy Rohit Saboo.
Introduction Background In image-guided interventions, anatomical structures are typically derived from medical images through segmentation. In radiation.
SensEye: A Multi-Tier Camera Sensor Network by Purushottam Kulkarni, Deepak Ganesan, Prashant Shenoy, and Qifeng Lu Presenters: Yen-Chia Chen and Ivan.
SlicerRT 3DSlicer extensions for radiotherapy research Andras Lasso 1, Csaba Pinter 1, Kevin Wang 2, Steve Pieper 3, Greg Sharp 4, and Gabor Fichtinger.
Introduction Methods Conclusion References [1] G Gauvin et al., "Real-Time Electromagnetic Navigation for Breast Tumor Resection: Proof of Concept," in.
Image-guided therapy and medical robotics tutorial using a LEGO Mindstorms NXT robot and 3D Slicer Danielle F. Pace, B.CmpH Ron Kikinis, M.D. Nobuhiko.
Objective Evaluation of Sonographic Skill in Focussed Assessment with Sonography for Trauma (FAST) Examinations Matthew S. Holden 1, Tamas Ungi 1, Conor.
3D SLAM for Omni-directional Camera
MESA LAB Multi-view image stitching Guimei Zhang MESA LAB MESA (Mechatronics, Embedded Systems and Automation) LAB School of Engineering, University of.
EMIS 8381 – Spring Netflix and Your Next Movie Night Nonlinear Programming Ron Andrews EMIS 8381.
Photogrammetry for Large Structures M. Kesteven CASS, CSIRO From Antikythera to the SKA Kerastari Workshop, June
Localization for Mobile Robot Using Monocular Vision Hyunsik Ahn Jan Tongmyong University.
Registration of functional PET and structural MR images PVEOut satellite meeting Budapest, June 11 th 2004 Peter Willendrup & Claus Svarer Neurobiology.
A Novel Image Registration Pipeline for 3- D Reconstruction from Microscopy Images Kun Huang, PhD; Ashish Sharma, PhD; Lee Cooper, MS; Kun Huang, PhD;
A Frequency-Domain Approach to Registration Estimation in 3-D Space Phillip Curtis Pierre Payeur Vision, Imaging, Video and Autonomous Systems Research.
Medical Image Analysis Image Registration Figures come from the textbook: Medical Image Analysis, by Atam P. Dhawan, IEEE Press, 2003.
Copyright © 2010 Siemens Medical Solutions USA, Inc. All rights reserved. Hierarchical Segmentation and Identification of Thoracic Vertebra Using Learning-based.
Conclusions The success rate of proposed method is higher than that of traditional MI MI based on GVFI is robust to noise GVFI based on f1 performs better.
NA-MIC National Alliance for Medical Image Computing An Integrated System for Image-Guided Radiofrequency Ablation (RFA) of Liver Tumors.
Jeff J. Orchard, M. Stella Atkins School of Computing Science, Simon Fraser University Freire et al. (1) pointed out that least squares based registration.
Real-Time Simultaneous Localization and Mapping with a Single Camera (Mono SLAM) Young Ki Baik Computer Vision Lab. Seoul National University.
Lijuan Zhao Advisors: Prof. Fatima Merchant Prof. Shishir Shah.
Automated Reading Assistance System Using Point-of-Gaze Estimation M.A.Sc. Thesis Presentation Automated Reading Assistance System Using Point-of-Gaze.
An Open-Source Solution for Interactive Acquisition, Processing and Transfer of Interventional Ultrasound Images Jonathan.
Image Registration Lecture ?: Detecting Failure & Assessing Success June 14, 2005 Prof. Charlene Tsai.
Visual Odometry David Nister, CVPR 2004
NA-MIC National Alliance for Medical Image Computing DBP2: Software Integration for Image Guided Surgery Gabor Fichtinger & Andras Lasso.
Affine Registration in R m 5. The matching function allows to define tentative correspondences and a RANSAC-like algorithm can be used to estimate the.
Methods Conclusions References ResultsIntroduction After all tests were performed, the optimal tolerance value was This tolerance value had an overall.
PLUS overview (Public software Library for UltraSound imaging research) Andras Lasso, Tamas Heffter, Csaba Pinter, Tamas Ungi, Thomas Kuiran Chen, Alexis.
PLUS overview (PerkLab ultrasound library and applications)
PLUS overview (PerkLab ultrasound library and applications) Andras Lasso Laboratory for Percutaneous Surgery, Queen’s University May 2, 2011.
Introduction Motivation Ultrasound-guided (USG) needle interventions, such as central venous catheterization (CVC), require simultaneous sonography and.
OpenIGTLink in Plus Tamas Ungi, Andras Lasso Laboratory for Percutaneous Surgery, Queen’s University August 4, 2011.
Methods Conclusions References ResultsBackground The program using the enhanced algorithm produces an optimal surface when used with simple inputs. Here,
Deformation Modeling for Robust 3D Face Matching Xioguang Lu and Anil K. Jain Dept. of Computer Science & Engineering Michigan State University.
PLUS overview (Public software Library for UltraSound imaging research) Andras Lasso, Tamas Heffter, Csaba Pinter, Tamas Ungi, Thomas Kuiran Chen, Alexis.
PLUS Model Catalog: A library of 3D-printable models
Introduction Results Methods Conclusions Acknowledgements
Assessing Technical Competence in Simulated Colonoscopy Using Joint Motion Analysis Matthew S. Holden1, Chang Nancy Wang2, Kyle MacNeil1, Ben Church1,
Homework | Reprojection Error
Dynamic management of segmented structures in 3D Slicer
Quantification of tumor localization needle displacement prior to tumor excision in navigated lumpectomy Christina Yan1, Tamas Ungi1, Gabrielle Gauvin2,
Matthew S. Holden, Zsuzsanna Keri, Tamas Ungi, Gabor Fichtinger
Figure 1: Current Setup of the Photoacoutic Registration System
Excitation based cone-beam X-ray luminescence tomography of nanophosphors with different concentrations Peng Gao*, Huangsheng Pu*, Junyan Rong, Wenli Zhang,
RGBD Camera Integration into CamC Computer Integrated Surgery II Spring, 2015 Han Xiao, under the auspices of Professor Nassir Navab, Bernhard Fuerst and.
Orthogonal and Least-Squares Based Coordinate Transforms for Optical Alignment Verification in Radiosurgery Ernesto Gomez PhD, Yasha Karant PhD, Veysi.
Target Registration Error
Target Registration Error
Presentation transcript:

Methods Validation with Simulated Data 1.Generate random linear objects in the model coordinate system. 2.Generate a random set of points on each linear object. 3.Apply a random (ground-truth) transformation to all points and add noise. Validation for Tool-to-Model Registration Linear Object Registration Algorithm Given a set of linear objects collected in the sensor coordinate system and a set of linear objects defined in the interventional tool coordinate system: Conclusions References & Acknowledgements Results Introduction Validation with Simulated Data Validation for Tool-to-Model Registration Validation for Volume-to-Model Registration The proposed registration algorithm is sufficiently accurate for practical registration of interventional phantoms and tools without fiducial points. The algorithm is implemented as a SlicerIGT ( module for 3D Slicer ( Future work involves refining the matching step, further automating the algorithm, and additional image registration experiments. [1] Anand, M., King, F., Ungi, T., Lasso, A., et al. (2014) "Design and Development of a Mobile Image Overlay System for Image-Guided Needle Interventions," 36th Annual International Conference of IEEE EMBS. [2] Carbajal, G., Lasso, A., Gomez, A., & Fichtinger, G. (2013). Improving N-wire phantom-based freehand ultrasound calibration. Int J Comput Assist Radiol Surg., 8, [3] Fitzpatrick, J. M., West, J. B., & Maurer, C. R. (1998). Predicting Error in Rigid-Body Registration. IEEE Transactions on Medical Imaging, 17, [4] Ungi, T., Sargent, D., Moult, E., Lasso, A., et al. (2012). Perk Tutor: An open-source training platform for ultrasound-guided needle insertions. IEEE Transactions on Biomedical Engineering, 59 (12), [5] Walsh, R., Soehl, M., Rankin, A., Lasso, A., et al. (2014). Design of a tracked ultrasound calibration phantom made of LEGO bricks. SPIE Medical Imaging. Matthew S. Holden is supported by the Ontario Graduate Scholarship. Gabor Fichtinger is supported as a Cancer Care Ontario Research Chair in Cancer Imaging. Linear Object Registration of Interventional Tools Matthew S. Holden, Gabor Fichtinger Laboratory for Percutaneous Surgery, School of Computing, Queen’s University, Kingston, Canada Motivation Registration allows clinicians to view tracked physical objects and images (from multiple modalities) in a common navigation space. Most applications use point-set registration algorithms; however, landmark points are not present on all interventional tools. Objective The objective is to develop a practical registration method for when landmark points are not available. We propose a method which uses points, lines, and planes (linear objects). The method should guarantee convergence to the optimal solution, even when correspondence is unknown. Table 1. Mean rotational and translational error for the fCal [2], lumbar spine [4], and gel block targeting tool [1] phantoms compared to the ground-truth point-set registration. Fig. 1. Photograph of user collecting points on the a) fCal phantom [2], b) lumbar spine phantom [4], c) LEGO® brick phantom [5], d) gel block targeting tool [1]. References indicated in green. Fig. 3. Plot of error in calculated registration as a function of noise for simulated data. Blue line indicates rotational error; red line indicates translational error. Four navigation phantoms were used for validating tool-to-model registration (Fig. 1). Because the LEGO® brick phantom does not have fiducial points, target registration error (TRE) [3] and point reconstruction accuracy (PRA) [2] were used to evaluate the registrations. Validation for Volume-to-Model Registration Validation for volume-to-model registration was performed using a reconstructed ultrasound volume of the Targeting Tutor phantom [4] (Fig. 2). Because the phantom had no fiducials, target registration error (TRE) [3] was used to evaluate the registrations. Fig. 2. Photographs of Targeting Tutor phantom [4] a) user ultrasound scanning, b) model of phantom, and c) ultrasound volume reconstruction. References indicated in green. PhantomRotational Error (°)Translational Error (mm) fCal Phantom Lumbar Spine Phantom Gel Block Tool AlgorithmMean TRE (mm)Mean PRA (mm) Point-Set Registration Linear Object Registration AlgorithmMean TRE (mm) Point-Set Registration4.05 ± 1.57 Linear Object Registration3.87 ± 0.91 Table 2. Target registration error (TRE) and point reconstruction accuracy (PRA) for point-set registration and linear object registration for the LEGO® brick phantom [5]. Table 3. Target registration error (TRE) for point-set registration and linear object registration for the Targeting Tutor phantom [4]. 1.Map collected points to linear objects via principal component analysis. 2.Match linear objects in the two coordinate frames using distances to a set of reference points. 3.Calculate the linear object centroid in each coordinate frame. 4.Perform point-set registration with known correspondence using centroid projections and direction/normal vectors. 5.Iteratively adjust the translation and rotation: a)Find the closest point on linear objects to collected points. b)Calculate the translational difference between point-sets. c)Calculate spherical point-set registration.