Gwenaëlle LEFEUVRE APC-Collège de France, Paris, France paris7.fr
1) Production of secondary electrons Widening of the fluorescence volume : 2 mm Negligible impact on electron length Atm. pressure : 99 % of electrons have E ≤ 5 keV
Gwenaëlle LEFEUVRE APC-Collège de France, Paris, France paris7.fr 2) Diffusion on the lead Influence on the electron spectrum simulated :
Gwenaëlle LEFEUVRE APC-Collège de France, Paris, France paris7.fr 3) Retro-diffusion on the scintillator Only effect : negligible
Gwenaëlle LEFEUVRE APC-Collège de France, Paris, France paris7.fr Gas circulation Switch
Gwenaëlle LEFEUVRE APC-Collège de France, Paris, France paris7.fr Principle of the DAQ
Gwenaëlle LEFEUVRE APC-Collège de France, Paris, France paris7.fr Calibration : how do the PMTs work ? electron-PMT : μ ~ pe integral & spectro PMT : μ ~ 0.02 pe P(0) = 0 Efficiency ~1 P(0) = 0.98, P(1) ~ 0.02 single photoelectron mode Poisson law :
Gwenaëlle LEFEUVRE APC-Collège de France, Paris, France paris7.fr Pure single pe in PMTs Analog signal ADC channel Photonis XP2020Q « 0 » / « 1 » ~ 50
Gwenaëlle LEFEUVRE APC-Collège de France, Paris, France paris7.fr Pure single pe in PMTs ADC channel Analog signal
Gwenaëlle LEFEUVRE APC-Collège de France, Paris, France paris7.fr Pure single pe in PMTs Detection inefficiency integral-PMT : 3.76 % spectro-PMT : 3.85% Analog signal ADC channel
Gwenaëlle LEFEUVRE APC-Collège de France, Paris, France paris7.fr Efficiency measurement process 1.X-Y mapping 2.Absolute efficiency in (x 0, y 0 ) 3.Normalization of the map New method in 3 steps uncertainty < 2 % CNRS patent application
Gwenaëlle LEFEUVRE APC-Collège de France, Paris, France paris7.fr 1) Mapping
Gwenaëlle LEFEUVRE APC-Collège de France, Paris, France paris7.fr 1) Mapping integral-PMT spectro-PMT
Gwenaëlle LEFEUVRE APC-Collège de France, Paris, France paris7.fr 1) Mapping spectro-PMT
Gwenaëlle LEFEUVRE APC-Collège de France, Paris, France paris7.fr 2) Absolute efficiency Absolute comparison with something known calibrated source or photodetector spatial distribution of light ~10 % accuracy NO gain ~1 when PMT have gain ~10 7
Gwenaëlle LEFEUVRE APC-Collège de France, Paris, France paris7.fr 2) Absolute efficiency Integrating spheres AND diaphragms
Gwenaëlle LEFEUVRE APC-Collège de France, Paris, France paris7.fr 2) Absolute efficiency Integrating Sphere NIST photodiode
Gwenaëlle LEFEUVRE APC-Collège de France, Paris, France paris7.fr 2) Absolute efficiency everything stays the same but the PMT 2 Spheres + 3 diaphragms Flux reduction 2.42 × 10 6
Gwenaëlle LEFEUVRE APC-Collège de France, Paris, France paris7.fr 3) Normalization of the map 18.5 % 1.7 % uncertainty Efficiency (%) integral-PMT
Gwenaëlle LEFEUVRE APC-Collège de France, Paris, France paris7.fr Result for integral-PMT Absolute efficiency measured (377 nm) Integral-PMT response adjusted to measurement Ulrich’s fluorescence spectrum Absolute efficiency of fluorescence detection ± Uncertainty : 2.2 % wavelength (nm) Efficiency
Gwenaëlle LEFEUVRE APC-Collège de France, Paris, France paris7.fr Integral measurement QuantityUncertainty Detection inefficiency, scaler dead timenegligible geometry (L e and solid angles)1.5 % Transmission of the quartz window1 % Efficiency of the PMT2.2 % TDC4 % Statistics0.2 % TOTAL4.91 % 4.23 ± 0.22 photons / m After normalizations (P, T, E) : 5 % G. Lefeuvre et al, to be published (NIM A)
Gwenaëlle LEFEUVRE APC-Collège de France, Paris, France paris7.fr Spectral measurement 3.9 ± 0.8 ph/m (Ulrich, Airlight workshop, 2003) wavelength (nm) yield (photons / m)
Gwenaëlle LEFEUVRE APC-Collège de France, Paris, France paris7.fr Spectral measurement Our results Ulrich’s spectrum, convoluted with our 3 nm resolution wavelength (nm) yield (photons / m)
Gwenaëlle LEFEUVRE APC-Collège de France, Paris, France paris7.fr Conclusion Bahcall & Waxman hep-ph/ v5 Fly’s Eye Extra-Galactic + Galactic Galactic No GZK HiRes Fly’Eyes Yakutsk AGASA E (eV) J x E 2,61 (eV 1,61 /m 2. sr. s)
Gwenaëlle LEFEUVRE APC-Collège de France, Paris, France paris7.fr Still much to measure... Pressure & Temperature dependences Impurities Spectrometer + CCD + light intensifier Reduction of the TDC uncertainty Flash-ADC
Gwenaëlle LEFEUVRE APC-Collège de France, Paris, France paris7.fr Thank you