PACS SVR 22/23 June 2006 PACS FPU Subunits1 FM FPU Subunits A. Poglitsch.

Slides:



Advertisements
Similar presentations
OTA Status Report K.Ichimoto/Y.Suematsu, NAOJ Following institutes/companies are in collaboration. J-side:ISAS (Institute of Space and Astronautical Science)
Advertisements

30-meter cabin refurbishment for a large Field Of View: status of on-going study S.Leclercq 28/04/2008.
M3 Instrument Design and Expected Performance Robert O. Green 12 May 2005.
LWIR FPA Mirror Image Problem & Recovery April 11, 2011 Roy W. Esplin Dave McLain.
Purpose of this Minilab
November 20, 2003University of Colorado The Off-Plane Option Study Results Potential Capabilities Webster Cash University of Colorado.
SXC meeting SRON, July 19-20, SXC meeting 19-20/07/2007 Alignment Positioning of mirror with respect to detector (internal). Positioning of total.
PACS IIDR 01/02 Mar 2001 Photoconductor Detector Arrays1 Photoconductor Detector Arrays for PAC S IIDR - ESTEC Stefan Kraft ANTEC-GmbH Germany Günter.
990901EIS_Opt.1 The Instrument: Optical Design Dr. John T. Mariska Data Coordination Scientist Naval Research Laboratory
Spectroscopic Data ASTR 3010 Lecture 16 Textbook Ch. 11.
PACS IQR13 Jan 2005 Optical Plans PFM 1 Optical Qualification and Plans for PFM N. Geis MPE.
PACS IIDR 01/02 Mar 2001 Instrument Overview1 PACS Instrument Design Description and System Performance A. Poglitsch.
Test Cryostat, OGSE and MGSE PACS IHDR: MPE 12/13 Nov 2003 AIV1 PACS Test Cryostat, OGSE and MGSE Gerd Jakob MPE.
FIR Optics Meeting – January Calibration issues related to the optical performances David Teyssier.
Use of a commercial laser tracker for optical alignment James H. Burge, Peng Su, Chunyu Zhao, Tom Zobrist College of Optical Sciences Steward Observatory.
W. Aalders FPU CDR 1-3 July 2003 HIFI 1 FPU CDR MCS HIFI MECHANISMS 1.Focal Plane Chopper (FPC) 2.Diplexer Rooftop Mirror Translator (DRT) 3.Pivot development.
September 19, 2002University of Colorado The Off-Plane Option for the Reflection Grating Spectrometer Webster Cash University of Colorado.
 Design  Manufacturing  Recent X-Ray tests  Status Vadim Burwitz, Peter Friedrich on behalf of the eROSITA team.
Optical Characterization of Liquid Crystal Switchable Mirror Philippe Lemarchand School of Physics You Supervisors’ Names Here Prof. Brian Norton Dr. John.
PACS IHDR 12/13 Nov 2003 PACS FPU Mirrors and Black Paint R. Graue, D. Kampf Kayser-Threde.
PACS IQR 13 Jan 2005 AVM/CQM ILT – test results1 PACS CQM/AVM ILT Results of functional/performance/ calibration tests.
PACS IHDR MPE 12/13 November 2003 AIV 1 PACS IHDR Integration, Qualification and Testing Reinhard Katterloher.
PACS SVR22/23 June 2006 PACS Thermal Behaviour1 PACS Thermal Behaviour Tests T. Müller, H. Feuchtgruber, A. Contursi, Cs. Kiss, Sz. Csizmadia.
CEA / PACS SVR phase 2 Photometer results from the first part of the FM ILT CEA - MPE - NHSC.
PACS IIDR 01/02 Mar 2001 Instrument Interfaces1 PACS FPU Opto-mechanical Design Overview and Interfaces J. Schubert MPE.
PACS IIDR 01/02 Mar 2001 FPFPU Alignment1 D. Kampf KAYSER-THREDE.
FM-ILT Results of the PACS FM1 Chopper Markus Nielbock Ulrich Klaas Jeroen Bouwman Helmut Dannerbauer Jürgen Schreiber Ulrich Grözinger.
1 of 28 A design study of a Cryogenic High Accurate Derotator.
14 October Observational Astronomy SPECTROSCOPY and spectrometers Kitchin, pp
15 October Observational Astronomy Direct imaging Photometry Kitchin pp ,
PACS FM-ILT SPECTROMETER SPATIAL CALIBRATION A. Contursi (H. Feuchtgruber) PACS Science Verification Review – 8/9 November 2007 MPE-Garching.
PACS IBDR 27/28 Feb 2002 Optical System Design1 N. Geis MPE.
FM-ILT Results: Mechanisms FM1 Chopper and Calibration Sources Markus Nielbock (MPIA) Babar Ali (IPAC) Jeroen Bouwman (MPIA) Helmut Dannerbauer (MPIA)
Herschel Space ObservatoryPACS Science Verification ReviewMPE 22/23 June 2006 GJ / MPE 1 PACS Test Facility Capabilities – Cryogenics and OGSE Gerd Jakob.
PACS IHDR 12/13 Nov 2003 IBDR Close-out1 Close-out of IBDR Recommendations A. Poglitsch.
PACS IQR 13 Jan 2005 First Assessment1 The PI’s Self-Assessment A. Poglitsch.
PACS SVR 2 18 Jan 2007 FM ILT: Mechanisms1 FM ILT Results: Mechanisms H. Feuchtgruber, H. Dannerbauer, N. Geis, C. Hartinger, U. Klaas, P. Royer.
Simple Double Beam Spectrometer
PACS SVR-II 18 January 2007 FM ILT overview1 The PACS FM ILT Phase I overview on actual test execution and analysis Eckhard Sturm MPE.
PACS IQR ESTEC 13 January 2005 Mech Qual Status 1 PACS IQR Mechanical Qualification Status and Plans for PFM Reinhard Katterloher R. Graue, D. Kampf, R.
PACS IBDR 27/28 February 2002 PACS Grating Assembly1 Grating Assembly E. Renotte Centre Spatial de Liège (B)
DECam Daily Flatfield Calibration DECam calibration workshop, TAMU April 20 th, 2009 Jean-Philippe Rheault, Texas A&M University.
PACS Spectrometer Spatial Calibration plan in PV phase A.Contursi D. Lutz and U. Klaas.
PACS SVR 22/23 June 2006 Instrument Performance Prediction1 PACS Instrument Model and Performance Prediction A. Poglitsch.
PACS IIDR ESTEC 01/02 March 2001 OGSE 1 PACS Instrument Intermediate Design Review (IIDR) Reinhard Katterloher OGSE.
The Active Optics System S. Thomas and the AO team.
Optimisation of the PACS Chopper Markus Nielbock Ulrich Klaas Jeroen Bouwman Helmut Dannerbauer Jürgen Schreiber Ulrich Grözinger.
PACS IHDR 12/13 Nov 2003 Filters1 N. Geis MPE. PACS IHDR 12/13 Nov 2003 Filters2 PACS Filter Scheme Filter scheme with 5 or 6 filters in series in each.
PACS SVR 22/23 June 2006 Scientific/Performance Requirements1 PACS Science and Performance Requirements A. Poglitsch.
1/10 Tatsuya KUME Mechanical Engineering Center, High Energy Accelerator Research Organization (KEK) ATF2-IN2P3-KEK kick-off meeting (Oct. 10, 2006) Phase.
PACS SVR 2 18 Jan 2007 FM ILT: Spectrometer1 Spectrometer Performance H. Feuchtgruber, T. Müller, A. Poglitsch.
PACS IHDR MPE 12/13 November 2003 System Engineering 1 PACS IHDR Model Philosophy, Budgets, Interfaces and IID-B Reinhard Katterloher.
PVPhotFlux PACS Photometer photometric calibration MPIA PACS Commissioning and PV Phase Plan Review 21 st – 22 nd January 2009, MPE Garching Markus Nielbock.
PACS IHDR MPE, 12/13 Nov 2003 Overall Schedule1 Otto H. Bauer MPE Garching.
Jan 21/22, 2009PACS PV Review Photometer Spatial Cal1 PACS Photometer Spatial Calibration PVPhotSpatial D.Lutz PACS PV Review Jan 21/ , MPE.
PACS ICC Readiness Review MPE, July 3/ PACS Photometer PV Phase Plan 1 Status Report M. Nielbock: PACS PHOT PV Phase Plan Markus Nielbock (MPIA)
Overview, Spectrometer Products and Processing Philosophy Phil Appleton on Behalf of PACS Team PACS IFU Spectrometer.
System Performance Metrics and Current Performance Status George Angeli.
PACS IBDR MPE 27/28 Feb 2002 System Engineering 1 PACS IBDR Model Philosophy / Development Plan Reinhard Katterloher.
14FEB2005/KWCAE2-UsersGroup Astro-E2 X-Ray Telescopes XRT Setup & Structure Performance Characteristics –Effective Area –Angular Resolution –Optical Axes.
10/2007 M.Taborelli, TS-MME M.Taborelli Structure fabrication: dimensional tolerances Contributions of : G.Arnau-Izquierdo, A.Cherif, D.Glaude, R.Leuxe,
Herschel EQM – Results and Lessons Learnt6/7 Feb 2006 PACS Overall Analysis1 Overall PACS EQM IMT Analysis Contributions by PACS ICC.
PACS IBDR MPE 27/28 Feb 2002 AIV 1 PACS IBDR Test Cryostat and OGSE Gerd Jakob MPE.
PACS IIDR 01/02 Mar 2001 Optical System Design1 N. Geis MPE.
0 Frequency Gain 1/R 1 R 2 R 3 0 Frequency Intensity Longitudinal modes of the cavity c/L G 0 ( ) Case of homogeneous broadening R2R2 R3R3 R1R1 G 0 ( )
SRI 2007: CLS Optical Metrology Facility- Overview
30-Nov-2006 Jean-Marc Defise - CSL
Interference.
MAMBO PRE-LAUNCH CALIBRATION CONSIDERATIONS
Observational Astronomy
Presentation transcript:

PACS SVR 22/23 June 2006 PACS FPU Subunits1 FM FPU Subunits A. Poglitsch

PACS SVR 22/23 June 2006 PACS FPU Subunits2 Performance of FPU and Subunits (I) Structure –Temperature (stability) requirements –Mechanical/optical tolerances, alignment Mirrors –Optical performance Chopper –Pointing accuracy –Dynamic behaviour (duty cycle) Grating –Optical performance of grating –Mechanical performance of grating drive Precision of position readout/actuator; jitter Dynamic properties (scanning/dithering/frequency switching)

PACS SVR 22/23 June 2006 PACS FPU Subunits3 Performance of FPU and Subunits (II) Filters –In-band transmission –Out-of-band suppression Calibration Sources –Absolute emissivity –Homogeneity

PACS SVR 22/23 June 2006 PACS FPU Subunits4 FPU Structure Most (but not all) of the FPU structure has been used in CQM Thermal requirements fulfilled by CQM as far as tested – expect no changes with FM –More detailed tests necessary w.r.t. sensitivity to L0/L1 interface temperature tolerances/variations –Ge:Ga detector thermal interface changed for thermal curing LHe Optical Alignment Stability Test under way –CQM ILT revealed no anomalies

PACS SVR 22/23 June 2006 PACS FPU Subunits5 Optics: Mirrors All mirrors tested individually at ambient temperature Visible light end-to-end test –Documentation with delivery of FPU No unexplained anomalies observed in QM –But PSF measurements were hampered by telescope simulator defocus

PACS SVR 22/23 June 2006 PACS FPU Subunits6 Chopper Mirror optical performance –Flatness< 150 nmtested; failed but accepted –Roughness< 50 nmtested; passed –Reflectivity> 98%by verified coating process Actuator performance (static/dynamic) –Range observation ± 4.1°; accuracy ± 1 arcmintested; ok –Duty cycle 10 Hz >80%tested; ok –Range calibration± 9°; accuracy ± 2 arcmintested; ok –Duty cycle calibration >70%tested; ok ± 0.5 arcsec on sky

PACS SVR 22/23 June 2006 PACS FPU Subunits7 Grating (I) Groove period - spec (± 0.7) µm –Only measured for CQM: g= ± 0.11 µm (2 sigma) Facet angles - spec 34.5° (± 1°) and 62.4° (± 1°) –Average: °; standard deviation: ° –Average: °; standard deviation: ° Groove regularity - spec 0.3 µm r.m.s. –Not verified  search for grating ghosts in ILT essential! –Positioning precision of machine used for ruling is 0.1 µm w.r.t. reference (reference: Heidenhain glass ruler). Measured ruler error (interferometric) over 100 mm travel: 0.15 µm (p-p); no measurement over full length available Groove depth - spec 56 µm ± 2 µm –Not measured, but 0 th order diffraction efficiency indicates no major deviation of grating profile from spec

PACS SVR 22/23 June 2006 PACS FPU Subunits8 Grating (II) Groove parallelism - spec ± 10” –Each groove to each other: not verified, but hard to miss with machine used for ruling –Grooves to rotation axis: no absolute measurement done, but grating drive wobble measured – uses up error entire budget!  Thorough test of position shifts and spectral shear/tilt as function of grating angle during ILT required! Overall surface flatness - spec 3 (goal 1.5) µm r.m.s. –Verification by WFE measurement with 10 µm interferometer in three grating orders partly achieved (only partial coverage of grating area by beam at a time); machining error <0.5 µm (but internal stress in grating body could lead to deformation)  Confirmation by measurement of PSF / spectral profile during ILT

PACS SVR 22/23 June 2006 PACS FPU Subunits9 Grating Drive Position precision within the useful angular throw: 8 arcsec (goal: 4 arcsec) –Calibration certificate: ± 3 arcsec; ± 4 arcsec (nom.; red.) Grating position “jitter” shall be < 0.1 arcsec/√Hz –verified by test Wavelength switching: amplitude of < 3 arcmin with frequencies of < 3 Hz and a duty cycle of 80% –verified by test Stabilization time for a grating step of 18 arcsec: < 23 ms –verified by test

PACS SVR 22/23 June 2006 PACS FPU Subunits10 Filters: “Red” Photometer

PACS SVR 22/23 June 2006 PACS FPU Subunits11 Filters: “Green” Photometer

PACS SVR 22/23 June 2006 PACS FPU Subunits12 Filters: “Blue” Photometer

PACS SVR 22/23 June 2006 PACS FPU Subunits13 Filters: “Red” Spectrometer

PACS SVR 22/23 June 2006 PACS FPU Subunits14 Filters: “Green” Spectrometer

PACS SVR 22/23 June 2006 PACS FPU Subunits15 Filters: “Blue” Spectrometer

PACS SVR 22/23 June 2006 PACS FPU Subunits16 Calibration Sources No measurements of FM CSs possible before FM ILT Cause of inhomogeneity in CS1 illumination identified in QM FPU; avoided in FM FPU Emissivity adjusted Stability expected in spec (similarity with QM) QM CS1CS2