Pulse-Height Analyzers Basic Functions Single Channel Analyzers Time Methods Multi-channel Analyzers.

Slides:



Advertisements
Similar presentations
A computer uses electric current to process information.
Advertisements

Computer Graphics- SCC 342
Lecture 17: Analog to Digital Converters Lecturers: Professor John Devlin Mr Robert Ross.
Cathode Ray Tubes and their Uses.
POTENTIAL GRADIENT & CATHODE RAY TUBE
4.6.CATHODE RAY OSCILLOSCOPE Ambar Sarup. What is a Cathode Ray? A cathode ray is a beam of fast flowing electrons.
Medical Oscilloscopes. Cathode ray oscilloscope (CRO) basics: –Many measurement are made easier by the CRO because it will display not only amplitude,
CATHODE RAY TUBE.
Oscilloscope. 1.Electron guns 2.Electron beams 3.Focusing coils 4.Deflection coils 5.Anode connection 6.Mask for separating beams for red, green, and.
OSCILLOSCOPES Introduction The Cathode-Ray Tube
Post Deflection Acceleration
Advanced Radio and Radar
Unit 9 Oscilloscopes. Objectives –After completing this chapter, the student should be able to: Explain the function of an oscilloscope. Identify the.
PRINCIPLES OF MEASUREMENT AND INSTRUMENTATION EKT 112
Screen Monitor Visual display unit (VDU)
EET 450 – Advanced Digital Video Display Systems.
Multichannel Analyzers A multichannel pulse-height analyzer (MCA) consists of an ADC, a histogramming memory, and a visual display of the histogram recorded.
Imaging Science Fundamentals Chester F. Carlson Center for Imaging Science Display Systems Viewing Images.
Instruments for Radiation Detection and Measurement
Day 19: Electrostatic Potential Energy & CRT Applications
 Popular instrument to show time, voltage both DC and AC. Shows Volts / Time.  Display waveforms. Spectrum scope shows volts to Frequency  Cathode (-ve.
CHAPTER 9 Oscilloscopes and Graphing Multimeters
Lecture 03 Fasih ur Rehman
ECE 5th SEMESTER Subject Consumer Electronics (CE)
The Television Picture
Chapter 13 AC Measurements. 2 Objectives –After completing this chapter, the student should be able to: Identify the types of meters available for AC.
Lecture No. 3.  Screen resolution  Color  Blank space between the pixels  Intentional image degradation  Brightness  Contrast  Refresh rate  Sensitivity.
Computer Graphics Hardware
Oscilloscope Muhajir Ab. Rahim School of Mechatronic Engineering
Vertical deflection system: * The function of the deflection system provides an amplified signal of the proper level to derive the vertical deflection.
Scopes  An oscilloscope is a visual voltmeter.  An oscilloscope converts electrical signals into a visual image representing voltage changes over a.
Chapter 17 Electric Potential.
Overview of Graphics Systems. Cathode-ray Tube (CRT) - colors are represented using Red, Green, and Blue components - the CRT has a mechanism for.
Introduction to Graphical Hardware Display Technologies
2/1 A Look at Monitors Roll call Video: monitors Step-by-step lecture.
What Exactly is Television?  A process of transmitting images through a signal from one place or another.
The electron.  An indivisible quantity of charge that orbits the nucleus of the atom.
Beam Penetration & Shadow Mask Method
TELEVISION CAMERA TUBES
Oscilloscope The main purposes of the oscilloscope are: Can view the input waveform voltage or current. Can measure instantaneous values of the input waveform.
4.5 ELECTRON BEAMS ELECTRONS AND ELECTRONICS. Electron Beams Given enough energy, electrons can escape from a conductor and move through a vacuum space.Beams.
 Display Devices Display Devices  Display Hardware  Components of CRT Components of CRT  Refresh CRT Refresh CRT  Electron Gun  Focussing system.
Week 9 Monitors and output to the screen. Monitors, also known as Visual display units (V.D.Us) Desktop computers contain a Cathode Ray Tube (C.R.T.)
Chapter No. 18 Radiation Detection and Measurements, Glenn T. Knoll, Third edition (2000), John Willey. Multichannel Pulse Analysis.
1 Chapter No. 17 Radiation Detection and Measurements, Glenn T. Knoll, Third edition (2000), John Willey. Measurement of Timing Properties.
Electrons Thermionic Emission
Physics Section 12.3 Apply the properties of sound resonance Recall: A standing wave is the result of the superposition of a wave and its reflection from.
1.  The primary output device in a graphics system is a video monitor. These monitors are based on Cathode Ray Tube (CRT) design.  CRT is a vacuum tube/electron.
PICTURE TUBE. ELECTROSTATIC FOCUSSING The electric field due to the positive potential at the accelerating grid extends through the opening the of the.
POWER POINT PRESENTATION ON
Oscilloscopes. Objectives –After completing this chapter, the student should be able to: Explain the function of an oscilloscope. Identify the basic parts.
DONE BY : RAWDA ALNWAISEH BAYAN TALEB
OSCILLOSCOPE: The device which convert any electrical signal to visual.(waveform) The graph, usually called the trace, is drawn by a beam of electrons.
The Cathode Ray Tube Monitor
Oscilloscope.
1 Chapter No. 9 Measurements and Detection of Radiation, Nicholas Tsolfanadis, 2010, McGRAW-HILL BOOK INTRODUCTION TO SPECTROSCOPY.
Presentation of cathode ray oscilloscope
ELECTRONIC DEVICES AND CIRCUITS
Oscilloscope.
Electronic Instrumentation CATHODE RAY OSCILLOSCOPE (CRO)
IMAGE ORTHICON.
Oscilloscope and its applications
INTRODUCTION PRESENTATION: OSCILLOSCOPE..
CATHODE RAY TUBE.
Graphics Systems SUBJECT: COMPUTER GRAPHICS LECTURE NO: 02 BATCH: 16BS(INFORMATION TECHNOLOGY) 1/4/
Electrons Thermionic Emission
Fluoroscopy: Viewing Systems
Fluoroscopy – Viewing Systems Optical Mirrors TV Camera & TV Camera Tubes Charge Coupled Devices (CCD) Based on: Principles of Radiographic Imaging, 3rd.
Chapter 2 Overview of Graphics Systems
CATHODE RAY TUBE By Dr. Vaibhav Jain Associate Professor, Dept. of Physics, D.A.V (PG) College, Bulandshahr, U.P., India.
Presentation transcript:

Pulse-Height Analyzers Basic Functions Single Channel Analyzers Time Methods Multi-channel Analyzers

Basic Function The amplitude of output signal is proportional to the energy of the radiation event detected Selective counting of those pulses within certain amplitude resulted in counting of selective energy range A certain energy range or interval is called energy channel

Single Channel Analyzers Counting only those within a single energy range Composed of three parts: Lower Level Discriminator (LLD), Upper Level Discriminator (ULD) and Anticoincidence Percentage window: a certain percentage of the window’s central voltage. A single channel analyzer without ULD is a circuit called discriminator

Timing Method Determine the timing of radiation event is important in Nuclear Medicine applications There are a number of timing methods available but two of those are often used in nuclear medicine: leading-edge and zero- crossing. Leading-edge uses the rising portion of the input pulse to trigger the lower level discriminator which depends on the pulse amplitude (suffer certain amount of inaccuracy--5 to 50 nsec for NaI(Tl)). Zero-crossing requires bipolar pulses and is more accurate (4 nsec for NaI(Tl)).

Multichannel Analyzers Simultaneous recording of multiple energy radiations. The principle of the popular Multichannel Analyzer (MCA) is different from the single channel analyzer The center of the Multichannel analyzer is the analog-to-digital converter (ADC) A memory is required for the sorting of energy channels (energy ranges, energy spectrum).

Analog-to-Digital Converter Two types of ADC are used in nuclear medicine for MCA and the interface between scintillation cameras and computers: Wilkinson or Ramp converter and successive approximation Both require time for the conversion which could be a “bottle neck” for the time resolution but is not a major problem for nuclear medicine application Both of the converters use binary number representation which means that the more bits the more accurate but requires more time and memory.

Ramp ADC RC circuitry and clock oscillator Discharging time proportional to the amplitude of the input pulse (radiation energy) Clock oscillator produces pulse train that are counted in a counting circuit The number of the clock pulses counted are proportional to the discharging time which in turn proportional the radiation energy).

Successive Approximation The input pulse is compared with one-half of the full scale The comparison voltage is then either increased or decreased by one half of its initial level depending on whether the pulse amplitude did or did not exceed the initial level. The process is repeated for several steps.

Time to Amplitude Converter

Scalers and Timers A device that only counts pulses is called a scaler An auxiliary device that controls the scaler counting time is called timer.

Analog Ratemeters A analog ratemeter is used to determine the average number of events occurring per unit time. The average is determined continuously rather than over discrete counting time Linear vs logarithmic ratemeters : V 0 =knQR p vs V0=klog(nQR p ) - wider range of counting rate Ratemeter responds to the rate change has a time constant which can be adjusted (change the capacitor)

Coincidence Unit

Cathode Ray Tube (CRT) Electron Gun Deflection Plates Phosphor-coated Display Screens Focus and Brightness Controls Colour Cathode Ray Tubes

Electron Gun Cathode: Hot filament-Tungsten, thoriated tungsten, nickel coated with oxides of barium and strontium, etc Control grid: a cape with a hole in its centre and a negative potential applied to control the passage of electrons. Accelerating anode: similar to control grid but reverse in shape. Positive potential applied to accelerate the electrons. Focusing anode: a second anode that further shapes the electron beam. A negative potential is applied to compress and focus the beam of electrons.

Deflection Plates Deflection plates are used for the positioning the electron beams on the screen: electronstatic or electromagnetic types. Electrostatic type applies voltages to the two sets of plates. Used for small screen with fast speed. Electromagenetic type uses two sets of wire coil. Used for large screen with a slower speed.

Phosphor-coated Display Screen Electrons strike the screen (glass coated with phosphorescent materials) and release phosphorescent light. Persistence time: the lifetime of the light emission from the phosphor. Persistence scope: long persistence time up to a few minutes. Composed of storage mesh and flood gun etc. Used as visual monitor for patient positioning with the gamma camera.

Focus and Brightness Control Second anode in the CRT controls the focus. It is a potentiometer that varies the potential applied to the anode. The control grid controls the brightness or electron intensity. Increasing the voltage (negative) decreases the intensity

Colour Cathode Ray Tube Three electron guns produce different electron beams onto arrays of individual phosphors which in turn, produce three colours, red, green and blue. A total of 64 colours can be produced by mixing the three colours for human eyes.

Oscilloscopes Oscilloscope is composed of a CRT, a signal amplifier and a time-sweep generator. It is used for displaying signal amplitude or frequency as a function of time. The signal amplifier is used to amplify the small signals to be displayed which is connected to the vertical deflection plates. The sweep signal is applied to horizontal deflection plates which sweeps the electron across the screen at a constant speed and is repeated. Often used in cardiac studies for nuclear medicine

Television or Computer Monitors A CRT tube with the two deflection plates controlled by constant frequency time-sweep generators. Electron gun controls the intensity at each point. Active or retrace sweeps: the electron gun is on or off. Most TV monitors use interlacing. The two sets of scan lines are called fields and the two interlaced fields is called frame. Each frame takes 1/30 or 1/25 sec depending on the frequency of the electricity. The resolution depends on the number of lines (65%) for the vertical direction and the changing rate of the brightness during the horizontal sweep.