Fiber Optic Cable Testing

Slides:



Advertisements
Similar presentations
OPTICAL FIBRE : TESTS AND MEASUREMENTS. BY TX-I FACULTY A.L.T.T.C; GHAZIABAD.
Advertisements

Chapter Twenty-Four: Fiber Optics
Fiber Optic Communication Systems
Session 4: Termination and Splices. 2 FO Connectors Specifications Specifications Loss Repeatability Environment (temp, humidity, vibration, etc.) Reliability.
Chromatic Dispersion Measurement methods  Pulse Delay Method (time-of-flight) ‏ IEC / ITU-T G650.1 EIA/TIA-455- FOTP-175-B  Phase Shift Method.
Pursuit of Better testing Instrument Let's go in the grandway......
Fiber Optics BASIC FIBER OPTIC LINK.
Optical Interfaces Lab Last Update Copyright 2014 Kenneth M. Chipps Ph.D. 1.
Optical Fiber Basics Part-3
Fiber-Optic Communications
Optical Fiber Testing Paul Minko EE 566 Oct. 22, 2003.
Lecture 4b Fiber Optics Communication Link 1. Introduction 2
Fiber-Optic Communications
OPTICAL MEASUREMENT DEVICES PRESENTED BY POOJA.P. NIKHIL SHARMA POOJA PRASAD RAJNEESH YADU ANNAPURNA CHANDRAKAR.
TESTING MULTIMODE FIBER
Testing Optical Fiber Links
Chapter 10 Optical fiber measuring instruments and testing single-mode fiber networks.
1 Fiber Optic Measurement Technique Piotr Turowicz Poznan Supercomputing and Networking Center Training Session Kiev 9-10 October.
LIGHT PROPAGATION IN FIBER
Chapter Twenty-Five: Optical Communication Systems.
Transmission Media Used in Campus Networks
Fiber Optic Basics. Why fiber? – Low loss & low signal spreading means greater distances between expensive repeater stations. – Less weight means easier.
FIBER OPTIC SYSTEM DESIGN
L5 Optical Fiber Link and LAN Design
LOCALIZATION & RECTIFICATION OF OPTICAL FIBER FAULT
OPTICAL TIME DOMAIN REFLECTOMETER (OTDR)
Testing Fiber Optic Media Last Update
Fundamental of Fiber Optics. Optical Fiber Total Internal Reflection.
1 Fiber Optics MULTIMODE VS. SINGLEMODE FIBER. 2 Fiber Optics When we talk about fiber we refer to either multimode or singlemode fiber. We further clarify.
Fiber-Optics Chad Richmond Aaron Parker Billy Spies Fiber.
1 Fiber Optics FIBER PERFORMANCE. 2 Fiber Optics The purity of optical fiber is critical for the best transmission of an optical signal inside a fiber.
Installation and testing
Network IQ Training Manual Chapter 6 - Fibre Testing and Measurement
Fiber Optics FUSION SPLICING.
Poznan Supercomputing and Networking Center
Fiber Optics LINK LOSS BUDGET.
1 Optical Time Domain Reflectometer Piotr Turowicz Poznan Supercomputing and Networking Center 9-10 October 2006.
1 §5 Multiplexed and distributed sensors 1.Basic sensor array topologies 2.Time division multiplexing (TDM) 3.Wavelength division multiplexing (WDM) 4.Optical.
Light Wave Systems Dr Manoj Kumar Professor & Head Department of ECE DAVIET,Jalandhar.
Optical Fiber Connections joints and couplers
 What is fiber-optic communication?  Method of transmitting information from one place to another  Sending pulses of light through optical fiber 
Dense Wavelength Division Multiplexing (DWDM) Technology
CS 453 Computer Networks Lecture 4 Layer 1 – Physical Layer.
A Company Selling Technology and not just a Product.
Mahmoud Al-Saba – Majed Al-Bishi –
Objectives Understand the importance of fiber-optic technologies in the information society Identify the fundamental components of a fiber-optic cable.
LOSSES IN FIBER OPTIC SYSTEM
O ptical R eturn L oss testing using KI 7340 series Loss Tester Kingfisher International PTY LTD V
Advantages of the One-Jumper Reference Method 15 July The Advantages of the One-Jumper Reference Method Over the Two-Jumper Reference Method when.
OBJECTIVE  INTRODUCTION OF OPTICAL FIBER  CONSTRUCTION OF OPTICAL FIBER  PRINCIPLE OF OPTICAL FIBER  TYPES OF OPTICAL FIBER  OPTICAL FIBER FAULTS.
Optical Loss Budget (Example 2)
Optical telecommunication networks.  Introduction  Multiplexing  Optical Multiplexing  Components of Optical Mux  Application  Advantages  Shortcomings/Future.
Fiber Optic Transmission SL/HL – Option C.3. Reflection/Refraction Reflection – A wave encounters a boundary between two mediums and cannot pass through.
Fiber Optic Transmission SL/HL – Option F Mr. Jean.
IB Physics Option F – Fibre Optics Mr. Jean. The plan: Video clip of the day Fibre Optics – C+-+Imaginghttps://ibphysics2016.wikispaces.com/Option+
Image: digikey.com 5 Image:
Application Note Fiber Connectivity Riedel solutions for broadcast applications 1 Application Note - Fiber Connectivity.
3 Fiber-Optic Cable Permission granted to reproduce for educational use only.© Goodheart-Willcox Co., Inc. Objectives  Explain how fiber-optic cable.
Digital Hierarchies There are two hierarchical structures that exist for digital networks: 1. Plesiochronous Digital Hierarchies 2. Synchronous Digital.
More stuff to know… MODULE 10
The Basics of Fiber Optics
Optical Fiber.
Introduction to Computers
Design of Optical Digital Transmission Systems
Fiber Optics 3 Losses and Testing
Long-Distance Communication (Carriers, Modulation, And Modems)
Guidelines for Fiber Optic Design and Installation
Design of Optical Digital Transmission Systems
Fiber Optic Transmission
Fibre Optic Transmission
Presentation transcript:

Fiber Optic Cable Testing Revised 11-24-08

Testing Requirements Parameter Example Instrument Optical power Source output, receiver signal level Power meter Attenuation or loss Fibers, cables, connectors Power meter and source, or Optical Loss Test Set (OLTS) Back reflection or Optical Return Loss (ORL) OTDR or OCWR (Optical Continuous Wave Reflectometer) Source wavelength Spectrum analyzer Backscatter Loss, length, fault location OTDR Fault location OTDR, VFL Bandwidth/dispersion Bandwidth tester

Power Meters The power meter by itself can be use to measure source power With a source, it can measure the loss of a cable plant, called insertion loss Most power measurements are in the range +10 dBm to -40 dBm Analog CATV (cable TV) or DWDM (Dense Wavelength Division Multiplexing) systems can have power up to +30 dBm (1 watt) Image from lanshack.com

Wavelengths Power meters are calibrated at three standard wavelengths 850 nm, 1300 nm, 1550 nm Typical measurement uncertainty is 5% (0.2 dB)

Sources Sources are either LED or laser 665 nm for plastic optical fiber 850 nm or 1300 nm for multimode 1310 nm or 1550 nm for singlemode Test your system with a source similar to the one that will be actually used to send data Image from lanshack.com

Optical Loss Test Set Power meter and source in a single unit Normally used in pairs Automated, more complex and expensive than the combination of a source and a power meter Rare in field testing Image from aflfiber.com

OTDR Optical Time-Domain Reflectometer Image from exfo.com

OTDR Uses Measure loss Locate breaks, splices, and connectors Produces graphic display of fiber status Can be stored for documentation and later reference Cable can be measured from one end

Backscatter A small amount of light is scattered back to the source from the fiber itself Splices or connector pairs cause a larger reflection of light back to the source Figure from techoptics.com (link Ch 17a)

OTDR Display Dead zone

OTDR Accuracy OTDR can give false loss values when coupling different fibers together Splices can even show more light on the other side “gainer” This is an illusion caused by increased scattering on the other side Splice loss uncertainty up to 0.8 dB

Types of OTDR Full-size Mini-OTDR Fault Finder Complex, powerful, expensive Mini-OTDR Fewer features Fault Finder Simplified, shows distance to a fault Links Ch 17c, d, e

Visual Cable Tracers and Visual Fault Locators Cable tracer is just a flashlight VFL uses an LED or Laser source to get more light into the fiber Useful to test a fiber for continuity To check to make sure the correct fiber is connected With bright sources, you can find the break by looking for light shining through the jacket Visible light only goes 3-5 km through fiber Images from links Ch 17 e & f

Fiber Identifiers Bends the fiber to detect the light Can be used on live fiber without interrupting service Can detect a special modulated tone sent down a fiber Image from tecratools.com (link Ch 17d)

Optical Continuous Wave Reflectometer (OCWR) Measures optical return loss (reflectance) of connectors Inaccurate on installed systems because it includes backscatter and all sources of reflectance See link Ch 17h Cable to be Tested

Microscope Used to inspect fibers and connectors Particularly during epoxy-polish process Image from link Ch 17g

Talkset Telephone calls over unused fibers Rarely needed now that we have cellphones See link Ch 17i

Attenuators Simulates the loss of a long fiber run Variable attenuators allow testing a network to see how much loss it can withstand Can use a gap, bending, or inserting optical filters Image from link Ch 17j

Reference Cables Test cables are needed to connect the cables to be tested to the test instruments Must have correct connectors, be clean, and high-quality (low loss) Use high-quality mating adapters Ceramic or metal – not plastic Singlemode rated are most accurate

Optical Power Levels Network Type Wavelength Power Range (dBm) Telecom 1330, 1550 +3 to -45 Telecom DWDM 1550 +20 to -30 Data 665, 790, 850, 1300 -10 to -30 CATV 1300, 1550 +10 to -6 Detectors are Silicon, Germanium, or Indium-Gallium-Arsenide semiconductors

Calibrations NIST is a standards laboratory Offers power calibration services at 850, 1300, and 1550 nm wavelengths Instruments should be returned to the manufacturer for calibration annually

Uncertainties Absolute power: 5% or 0.2 dB Insertion loss: 0.5 dB or more OTDR: up to several dB Optical return loss: 1 dB or more Although meters show a reading with hundredths of a decibel, they don’t mean anything A 2.13 dB loss might well re-measure as 2.54 dB

Optical Fiber Testing Before installation Test continuity with cable tracer or VFL Measure attenuation with cutback method Cut off known length, measure power increase

Sources for Loss Measurements Most multimode systems use LED sources High-speed multimode often uses VCSELs (1 Gbps and higher) See link Ch 17k Singlemode systems use laser sources Test with the source you will really use BUT Argilent says you should test all Multimode with LEDs (link Ch 17l)

Modal Effects in Multimode Fiber Mode scramblers mix modes to equalize power in all modes Can be made with a section of step-index fiber Mode filters remove higher-order modes to reach equilibrium modal distribution Can be made with a mandrel wrap

Modal Effects in Singlemode Fiber Singlemode fibers shorter than 10 meters may have extra modes Use a launch cord to avoid that problem

OTDR Pulse Width Longer pulses can see further down the cable because they have more light But they have less accuracy finding locations From link Ch 17a

OTDR Uncertainties Dead zone Distance Resolution Nothing can be measured for the first 100 meters or so Distance Resolution Two events too close together cannot be resolved Especially with long pulses

OTDR Distance Errors Speed of light in fiber Slack in fiber May not be exactly what the OTDR expects, distorting distances Slack in fiber OTDR measures length along the fiber, which is usually 1% - 2% longer than the length along the cable

OTDR Loss Errors Joining two fibers with different backscatter coefficients will cause: Too high a loss when measured in one direction Too low a loss in the other direction For accurate loss measurements, measure from both ends and average the results

OTDR Ghosts Secondary reflection appears at double the real cable length Using index-matching gel will eliminate ghosts

Dispersion Multimode fibers suffer from modal dispersion All fibers suffer from chromatic dispersion Because different wavelengths travel at different speeds, and no source is completely monochromatic In very long singlemode networks, polarization mode dispersion also matters

Bandwidth Testers There is a new unit available to test bandwidth in the field, but it is not commonly done yet (link Ch 17 k) Input Output

Connector Insertion Loss Test This test gives the typical loss of a connector type

Modal Distribution The insertion loss test FOTP-34 by the TIA Three options of modal distribution EMD or steady state After a mandrel wrap Fully filled After a mode scrambler Any other specified conditions

Microscopes Used to inspect the ends of polished connectors Helpful to view the connector at an angle while lighting it from the side Only defects over the core really matter

Optical Return Loss in Connectors A pair of glass-air interfaces for nonphysical contact connectors without index-matching gel 4% reflectance – loss of 0.3 dB due to reflectance PC connectors can have a reflectance of 1% or an ORL of 20 dB Much less with Angled PC connectors – 40 to 60 dB Reflectance can be a problem in high bitrate singlemode systems

Basic Cable Loss Test Test FOTP-171 Measure power through launch cable Then add cable to test This tests only one connector – turn the cable around to test the other end

Double-Ended Loss Test Uses both a launch and receive cable

Single-Cable Reference Refer to this condition Test this way EIA/TIA 568 requires this See link Ch 17m

Why Use Single-Cable Reference? It gives highest loss and lowest uncertainty It tests both connectors on the cable to test

Choosing a Launch Cable for Testing Choose cables with low loss It is not necessary to get connectors and fiber with tighter specifications Handle the launch cables carefully Inspect them with a microscope Keep them clean Use splice bushings with metal or ceramic alignment sleeves

Mismatched Fibers Coupling a smaller fiber to a larger one causes only a small loss (0.3 dB or so) Connecting large fiber to small fiber causes a large loss Both because of diameter and numerical aperture

Testing the Installed Cable Plant Can use one-cable reference, or two-cable, or three-cable, but the type of reference must be documented

Wavelengths Usually test multimode at both 850 and 1300 nm with LED sources Singlemode test is usually at 1300 nm only 1550 nm is sometimes required also For long-distance, and to show that WDM can be performed later Also shows microbends – 1550 test is much more sensitive to bending loss

Optical Splitter Splits light signal from one fiber into two fibers Figures from tpub.com (link Ch 17n)

Couplers Can Split or Combine You can also split one to M, or combine M to 1

M to N Coupler

Making Couplers

Wavelength Division Multiplexers Light entering from the left containing two wavelengths is separated into the two fibers on the right Combining the two signals is also possible Requires special equipment and techniques to test Image from link Ch 17o

Fiber Optic Amplifiers Boosts signal without converting it to electricity Complicated to test, require special equipment Image from link Ch 17p

Fiber Optic Switch See links Ch 17q and 17r

Fiber Optic Datalinks The diagram shows a single link Most networks will be bidirectional (full duplex) with two links working in opposite directions

Bit Error Rate The receiver power must be within the operating range Too little power leads to high bit error rates (wrong data at receiver) Too much power saturates the detector and also leads to high bit error rates Use an attenuator in this case

What Goes Wrong? Often the two fibers are connected backwards – check them with a visual tracer Check receiver power level Check plant loss with double-ended method

Don’t Use an OTDR to Measure Plant Loss OTDR does not see the loss of the end connectors Its power source is not the same as normal LAN power sources OTDR measurements are affected by backscatter coefficient which may not be the same for all the cables in a network

Back Reflection Back reflection can cause networks to fail even though the loss is low Power meter can’t measure reflection Use an OTDR or OCWR Cure it by splicing in low-reflection patch cords to replace high-reflectance connectors Angled PC connectors are designed to minimize reflectance for this reason (not mentioned in textbook)

Reliability Once installed, the fiber optics should work for a long time People break the cable by accident Mark where cables are buried Bury a marker tape above the cable Use orange or yellow jacket cable indoors A broken cable just behind a connector in a patch panel is hard to find

Source Failure LED in laser transmitter drops in power as it ages Laser sources are feedback-stabilized so they remain constant in power till they fail