Cerebral Haemodynamics and Auto-Regulatory Models of the Circle of Willis K T Moorhead, C V Doran, J G Chase, and T David University of Canterbury Dept.

Slides:



Advertisements
Similar presentations
Application of the Root-Locus Method to the Design and Sensitivity Analysis of Closed-Loop Thermoacoustic Engines C Mark Johnson.
Advertisements

ARTreat Vision. Atherosclerosis The problem Definition: “Atherosclerosis is a vascular disease associated with the accumulation of lipids leading to the.
Blood Pressure. blood pressure is the pressure blood on the walls of the circulatory system. Blood pressure depends on two factors… 1.cardiac output -
FIRST AND SECOND-ORDER TRANSIENT CIRCUITS
Computational Mechanics & Numerical Mathematics University of Groningen Multi-scale modeling of the carotid artery G. Rozema, A.E.P. Veldman, N.M. Maurits.
System Science Ph.D. Program Oregon Health & Science Univ. Complex Systems Laboratory 1 Estimation of Subject Specific ICP Dynamic Models Using Prospective.
One Dimensional Steady Heat Conduction problems P M V Subbarao Associate Professor Mechanical Engineering Department IIT Delhi Simple ideas for complex.
BLOOD PRESSURE - PHYSIOLOGY ROBYN DANE AND KATY DAVIDSON.
THE BLOOD VESSELS & BLOOD PRESSURE Lecture – 9 Dr. Zahoor Ali Shaikh 1.
Cardiovascular Dynamics During Exercise
Blood Pressure  Blood pressure is the force of blood surging against the walls of the arteries.  Blood pressure measurements are expressed in two numbers.
Blood Pressure— The driving force Stephen Hales 1733 Blood pressure (hydrostatic pressure) is the force exerted by the blood against any unit area of vessel.
The Cardiovascular System … and the beat goes on..
RF-Accelerating Structure: Cooling Circuit Modeling Riku Raatikainen
FIRST ORDER TRANSIENT CIRCUITS
The Cardiovascular System blood vessels. Blood Circulation Blood is carried in a closed system of vessels that begins and ends at the heart.
Chapter 26 The Urinary System Part B.
Biology 2672a: Comparative Animal Physiology Circulation II: Regulation of Circulation.
Circulation.
Identification of Time Varying Cardiac Disease State Using a Minimal Cardiac Model with Reflex Actions 14 th IFAC SYMPOSIUM ON SYSTEM IDENTIFICATION, SYSID-2006.
Glomerular Filtration Rate (GFR) and Renal Blood Flow (RBF) Beth Lee, PhD Physiology and Cell Biology The Ohio State University College of Medicine.
VITAL SIGNS Vital signs are measures of various physiological statistics, often taken by health professionals, in order to assess the most basic body.
Dynamics of Blood Flow Transport System A closed double-pump system: Systemic Circulation Lung Circulation Left side of heart Right side of heart.
Hemodynamics of the Vasculature
Quality of Curve Fitting P M V Subbarao Professor Mechanical Engineering Department Suitability of A Model to a Data Set…..
Blood Pressure Required to move blood and all its constituents throughout the body.
Blood Pressure Clinical Science Applied to Nursing CopyrightCSAN2005CardiffUniversity.
Driving Force of Filtration n The filtration across membranes is driven by the net filtration pressure n The net filtration pressure = net hydrostatic.
Multi-scale modeling of the carotid artery
Pulmonary Flow Resistive Device Taya Furmanski Albert Attia Advisor: Thomas Doyle, M.D. April 9, 2003.
Metabolism and properties of the myocardium, arterial and venous haemodynamics, blood pressure Romana Šlamberová, M.D. Ph.D. Department of Normal, Pathological.
Lumped Parameter and Feedback Control Models of the Auto-Regulatory Response in the Circle of Willis World Congress on Medical Physics and Biomedical Engineering.
The Heart Chapter 18 – Day 4 2/13/08.
Clinical cardiovascular identification with limited data and fast forward simulation 6 th IFAC SYMPOSIUM ON MODELLING AND CONTROL IN BIOMEDICAL SYSTEMS.
Simulating Cardiac Disease From Onset with a Minimal Cardiac Model Including Reflex Actions THE 12 th INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING.
Control and regulation of GFR and renal blood flow
Blood Pressure Clinical Science Applied to Nursing CopyrightCSAN2005CardiffUniversity.
1 Mathematical modeling of blood flow in translational medicine (1) Moscow Institute of Physics and Technology (2) Institute of Numerical Mathematics Workgroup.
1D and 3D Models of Auto-Regulated Cerebrovascular Flow THE 26th ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY.
Feedback systems for controlling body functions
Pulmonary Flow Resistive Device Taya Furmanski Albert Attia Advisor: Thomas Doyle, M.D. March 17, 2003.
DR—Noha Elsayed The Circulatory System.
CV Dynamics flow dynamics For Biol 260 PART 1. Physiology of Circulation: Definition of Terms Blood flow – Volume of blood flowing through a vessel, an.
Topic 1.2/1.3, Risk factors for CVD Blood Pressure and tissue fluid formation.
Glomerular Filtration and Regulation of Glomerular Filtration Rate
Question 1 Which of the following is NOT true of the parasympathetic control of the heart? A. It affects muscarinic receptors. B. It decreases heart.
Date of download: 7/3/2016 Copyright © 2016 SPIE. All rights reserved. Static autoregulation. The classic static autoregulation curve shows a plateau of.
Identification of Patient Specific Parameters for a Minimal Cardiac Model THE 26th ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE.
ME 7980 Cardiovascular Biofluid Mechanics
Homeostasis.
The Electrocardiogram
Capillary Fluid Exchange
Human Circulation A closer look.
FIRST AND SECOND-ORDER TRANSIENT CIRCUITS
Chapter 30 – Respiratory & Circulatory Systems
Blood Pressure.
CARDIOVASCULAR 5 BLOOD FLOW.
Subarachnoid hemorrhage after carotid artery stenting
Human Circulation A closer look.
Figure 1 Management of acute ischaemic stroke after ICA-T occlusion
Volume 80, Issue 5, Pages (May 2001)
Glomerular Filtration and Regulation of Glomerular Filtration Rate
Chapter 26 The Urinary System Part B.
Chapter 46 – Circulatory & Respiratory Systems
Kidney.
AUTOREGULATIONOF CEREBRAL BLOOD FLOW
Autoregulation Of Cerebral Blood Flow
Spontaneous recanalization of a middle cerebral artery occlusion with subsequent carotid endarterectomy  Andrew J. Jackson, BSc, MBChB, MRCS, Amit Patel,
W. Wakeland 1,2, J. Fusion 1, B. Goldstein 3
The Vascular System.
Presentation transcript:

Cerebral Haemodynamics and Auto-Regulatory Models of the Circle of Willis K T Moorhead, C V Doran, J G Chase, and T David University of Canterbury Dept of Mechanical Engineering

Research Goals Desire: Better understand cerebral haemodynamics in the Circle of Willis cerebral arterial system (CoW) –Including realistic dynamics for auto-regulation phenomenon –Account for “essential dynamics” of the system –Match existing clinical data and/or understanding Goal: Create a simplified model of CoW haemodynamics to assist in rapid diagnosis of stroke risk patients prior to surgery or other procedures –Must be computationally simpler than higher dimensional CFD –Must be flexible enough to model different geometry’s and conditions of the CoW arterial system

Circle of Willis (CoW) Definitions Simplified geometry schematic of arterial system for basic dynamic analysis

Modeling the CoW R P1P1 P2P2 q Constant resistance between nodes captured by simple circuit analogy: Q = (P1 – P2)/R Leads to system of linear equations for flow rates q(t) due to input conditions p(t): Ax(t) = b(t) Auto-regulation not included yet

Auto-Regulation Dynamic phenomena where in blood perfusion pressure to efferent arteries (L and R: ACA, MCA, PCA) is maintained within set limits. Feedback controlled system based on the body’s sensing of changes of flow rate from a set (desired) reference. Control input “u” changes the dilation/contraction of the arterioles within the cerebral territory supplied by the efferent artery to increase (flow to high) or decrease (flow to low) resistance. Auto-regulation modeled as feedback controlled, time varying resistances on efferent arteries, creating a non-linear system

Auto-Regulation Model vessel wall q  qref smooth muscle cells Ca 1.Pressure and/or flow that is different than desired is sensed 2.Ca ions released 3.Triggering muscle fiber contraction/expansion 4.Contracting/Dilating vessel radius 5.Changing resistance of vessels Resistance dynamics of contraction/dilation Standard PID feedback control law Amount of change is limited Resistance is a function of error,e(t) Error is a function of flow rates Flow rates are what you solve for System is nonlinear: A(x(t))*x(t) = b(t) Solve it iteratively between resistance and flow rates

Model Parameters Reference and constant resistances based known physiological data –Lengths, radii, etc –Communicating arteries generally have very high resistance Geometry may commonly have one omitted element Physiological data from thigh cuff experiments is used to determine control gains –Correlated to match 20% drop and 20 second return time in clinical data for 20 mmHg drop in afferent blood pressure –Reference resistances for efferent arteries determined to match physiological data which states that efferent resistances follow the ratio (6:3:4) for the ACA:MCA:PCA arteries in the steady state Boundary conditions: –Afferent pressure: 93mm Hg –Efferent pressure: 4mm Hg

Simulations Run Drop in RICA of 20mm Hg is tested to simulate a stenosis Simulations run for a single vessel omission, testing each element of the CoW –Used to verify model versus prior research using higher dimensional (2D) CFD methods that are computationally intense Simulation of a high risk stroke case with ICA blockage increasing resistance –To illustrate potential of this model. All simulations run for symmetric configuration where resistances on L and R sides are not varied.

Results – Omitted Artery Cases % drop in flow through RMCA after 20% pressure drop in RICA (Ferrandez, 2002)(Present Model) Balanced Configuration 1819 Missing LPCA 1 Not simulated19 Missing LPCoA1819 Missing LACA Missing ACoA1820 Missing RACA Missing RPCoA2019 Missing RPCA 1 Not simulated19 No failure to return to qref flow Return times ~15-25 seconds Shows robustness of CoW system in maintaining flow and pressure

Results – Omitted Artery Cases Change in flow rate due to pressure drop: No omitted arteries Red shows change direction from steady state ACoA omitted – common anomaly All results are % change of steady state values Prior to pressure drop Note loss of communicating artery flow to support right side

Results – High Stroke Risk Case High stroke risk case: –LICA and RICA radii reduced 50% and 30% respectively, representing potential carotid artery blockages –LPCA1 (Left Proximal Posterior Cerebral Artery) is omitted –20mm Hg pressure drop in RICA simulating a stenosis is simulated This individual would be hypertensive to maintain steady state flow requirements – captured by model. –93mm Hg does not maintain reference flow rates in several efferent arteries, even at maximum dilation –~113mm Hg required to attain desired level. Case is not common in all individuals but is encountered in those needing carotid artery surgery

Results – High Stroke Risk Case LEFTRIGHT LMCA fails to achieve desired flow rate indicating a potential stroke risk under any procedure which entails such a pressure drop

Conclusions A new, simple model of cerebral haemodynamics created Model includes dynamics of auto-regulation and is non-linear Iterative solution method developed offering fast solution and enabling use as a rapid diagnosis “what-if” tool. Model verified against limited clinical data and prior research using higher dimensional CFD Several simulations run for omitted artery cases illustrate the robustness of the CoW High stroke risk case illustrates the potential for simulating patient specific geometry and situation to determine risk Future work includes more physiologically accurate auto-regulation and geometry modelling, more clinical verification using existing data, and modelling of greater variety of potential structures (eg fused vessels).