ERU WATSAN MOD. 15 SETA plant centrifugal pump: Maintenance and replacement.

Slides:



Advertisements
Similar presentations
International Mechanical Codes Scald Protection. – Where a combination potable water-heating and space-heating system requires water for space.
Advertisements

Boiler Operation Procedures
HS-30 Hydrostatic Pressure Sensor Presented By Peter Ward Hydrological Services Pty Ltd.
Daikin Altherma™ Troubling Shooting
Cooling & Lubrication Chapter Review MARCH-2004 Cooling & Lubrication Chapter review Image viewing Interactive questions Closing.
Panasonic Expérience Leadership in Japon : CO2 Models Most famous manufacturer of compressor in the world(high technology of inverter) High experience.
RMM Systems, LLC By Sam Rietta RMM Systems, LLC is a manufacturer's representative firm focused on providing value added sales solutions by providing.
Transportation Tuesday TRANSPORTATION TUESDAY VEHICLE CARE BE AWARE !! Reliable vehicle care = Safety and Dependability.
FoamPro 1600 Series Fully automatic Class A foam ONLY
 Description of PressurePro System  Identify system components  Display and Operational Modes  Sensor alerts  Checking of tire pressures  Manual.
Air Finned Heat Exchanger for Mechanical Seal EXPERT ENGINEERING – MUMBAI, INDIA Air Finned Heat Exchanger for Mechanical Seals - having immense potential.
Cooling As working temperatures rise, the strength of metals used reduces. This in turn will force manufacturers to use superior metals/alloys, which can.
1 Expansion Tanks. 2 3 Expansion Tanks WHY USE THEM TYPES LOCATION SIZING.
Installation and Initial Start Up Worldwide Manufacturer of PSA Generators by Laco Remias, Service Engineer, Aftersales & Service.
1 Engine Protector Safe Rider Vehicle Technologies (Pty) Ltd PO Box 11376, Rynfield South Africa Tel./ fax Cell:
Introduction to FLUID COPLING.
Water pumping.
ERU WATSAN SPANISH RED CROSS Water Treatment Plant SETA.
M3D - LMEA Coles. Aim To achieve a greater understanding and appreciation of HMS Lancaster’s Pall Rochem Reverse Osmosis Plants.
Measuring Pressure. Atmospheric Pressure Recall: Caused by the weight of the air molecules above us. Typically kPa or Pa Measured using.
SPD Cooling workshop: PLC item details. ups upgrade: 10-12' after trigger 24V - what to do in 10 minutes Present situation: In case of “normal power”
Iris Range : «Unconventional» conventional detectors.
Water Storage, Transport & Distribution. Water Storage, Transport and Distribution WATSAN M15 ERU 2 Contents 1.Needs 2.Crucial principles 3.Storage 4.Transport.
EESIFLO International Pte Ltd
Lease Automatic Custody Transfer
PHENIX UPGRADE Stony Brook Project Hadron Blind Detector Glove Box 31Aug05.
FMTV COOLING SYSTEMS 4/23/2017.
Chapter 9 Fluid Mechanics. Fluids “A nonsolid state of matter in which the atoms or molecules are free to move past each other, as in a gas or liquid.”
(U-shaped tank) WATER TANK SLUDGE TANK This system makes it possible to recover the liquid part of the suctioned material in the sludge compartment.
SETA Water treatment plant maintenance
Chapter 9 Fluid Mechanics. Fluids “A nonsolid state of matter in which the atoms or molecules are free to move past each other, as in a gas or liquid.”
Good Morning! 6/5/2016 Starter: why is it that a 1000 mega gram cruise ship can float when a ½ kg rock sinks? (there are two answers really) Today we.
Safety Talk 3 / 1 Safety Talk 3 Safe Operation of Storage Tanks: Temperature and Pressure.
OXFAM-DELAGUA Water analysis kit. OXFAM-DELAGUA water analysis kit WATSAN M15 ERU 2 Contents 1.Components 2.Capabilities 3.Maintenance 4. Summary of bacteriological.
Chapter 9 Fluid Mechanics. Fluids “A nonsolid state of matter in which the atoms or molecules are free to move past each other, as in a gas or liquid.”
TECHNICAL TRAINING INVERTER-Y
Installation scenarios. WATSAN M15 ERU 2 Installation scenarios WATSAN M15 ERU 3 SUMMARY OF EQUIPMENT 5 Water pumps (abstraction). Maximum pumping capacity.
Urban Storm Drain Design: Multiple Pumps. Multiple Pumps The HDM and FHWA recommend more than one pump Redundancy Flexibility Ability to manage flows.
Cooling & Lubrication Chapter Review November 7, 2000By Laval Paradis - NSCC Cooling & Lubrication Chapter review Image viewing Interactive questions.
Cooling plant upgrade Jose Botelho Direito, Michele Battistin, Stephane Berry, Sebastien Roussee 2 nd SPD Cooling Workshop 30/11/201112nd SPD.
CUE – Make Any Pump an E-Pump
Variable Speed Applied to Pumps. Life Cycle Costs - Courtesy of Hydraulic Institute and Europump Initial cost is not the only cost associated with a pump.
Hydro Multi-B – (2) or (3) CME Pumps in Parallel
Service Section Technical Training December 2005.
Charging Cart Instruction & User Manual EnTrans Technology Co., Ltd.
What is a Cryocar? It is a liquid nitrogen powered vehicle. Propulsion systems are cryogenic heat engines in which a cryogenic substance is used as a.
C5305 – WASTE WATER AND WATER SUPPLY ENGINEERING
Oil-free Vacuum Pump / Compressor Today’s Instruments Co., Ltd.
The water project Pictures: Mats Lagergren ……………………….. Partner Church in Zimbabwe.
Apparatus Testing Sugar Land Fire Department Driver/Operator-Pumper Academy Spring 2003.
MAINTENANCE INTERVAL SCHEDULE D6R TRACK TYPE TRACTOR 7AR EVERY 10 SERVICE HOURS OR DAILY.
All Freezer Advance. When the Freezer is first supplied with power or if a power outage occurs, the display will indicate this by flashing the temperature.
Charging Cart Instruction & User Manual EnTrans Technology Co., Ltd.
shift to the Test Mode (Forced Operation).
WP 2 – Valorisation of Sludge
2016 RZR xp Turbo – COOLING Hood Scoop & Air Deflector
Radiopharmaceutical Production
REVIEW AND RECOMMENDATIONS
TABLE OF CONTENTS A- Unit description B- Microprocessor Control box
Lecture Objectives: Look at the cooling side of air condition
Digital Chart Recorder Operation
More and more power failures are being experienced through the Republic of South Africa. It is clear that this situation is not improving, nor will it.
February 2019.
Last 30 days status indicator
November technical stop activities:
Filling of SAPPHIRE 25 & 42 Bar Systems (TFPP Hardware)
Houseplants Project By:.
JOH-KGN JvW-X1 FABRICATION OF FLOW CONTROL VALVES FOR OLKARIA I GEOTHERMAL POWER PLANT Fredrick Olwal - Snr Technician and Joseph Odhiambo.
Presentation transcript:

ERU WATSAN MOD. 15 SETA plant centrifugal pump: Maintenance and replacement

WATSAN M15 ERU SETA plant centrifugal pump 2 1.Grundfos MQ 3-45 centrifugal pump description 2.Functioning 3.Maintenance 4.Pump replacement Contents

WATSAN M15 ERU SETA plant centrifugal pump 3 1.MQ 3-45 centrifugal pump description

WATSAN M15 ERU SETA plant centrifugal pump 4 Grundfos MQ 3-45 centrifugal pump

WATSAN M15 ERU SETA plant centrifugal pump 5 Technical data Maximum pressure: 4.5 bares Minimum ambient temperature: 0 ºC Maximum ambient temperature: 45 ºC Minimum liquid temperature: 0 ºC Maximum liquid temperature: 35 ºC Net weight: 13 kg Air pressure in tank: 1,5 – 1,7 bares

WATSAN M15 ERU SETA plant centrifugal pump 6 2. Functioning

WATSAN M15 ERU SETA plant centrifugal pump 7 READ MANUFACTURER INSTRUCTIONS

WATSAN M15 ERU SETA plant centrifugal pump 8 Control panel

WATSAN M15 ERU SETA plant centrifugal pump 9 Maximum water level in the sedimentation tank The water level control starts the submergible pump below the maximum water level. The water level control stops the submergible pump above the maximum water level. Minimum water level in the sedimentation tank The water level control stops the centrifugal pump and starts the submergible pump below the minimum water level. The water level control starts the centrifugal pump and stops the submergible pump above the minimum water level but the maximum water level control keeps the submergible pump working. Starting up

WATSAN M15 ERU SETA plant centrifugal pump 10 Stopping The pump includes an electronic protection function which will stop the pump in case of: lack of water over temperature overload engine frequent starts/stops (the “Alarm” light blinks) The pump automatically restarts after 30 minutes (over 24 hours) in case any kind of failure if the automatic restart function is activated.

WATSAN M15 ERU SETA plant centrifugal pump Maintenance

WATSAN M15 ERU SETA plant centrifugal pump 12 Maintenance The pump is maintenance free under normal conditions. See instruction manual for possible breakdowns.

WATSAN M15 ERU SETA plant centrifugal pump Replacement of the pump

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

WATSAN M15 ERU SETA plant centrifugal pump 30 Thank you……….