Recyclable Replacement Service Pack Contents Batteries Grease pouch prefilled Waterproof cover Technolube Electromechanical Refillable Lubricators * *

Slides:



Advertisements
Similar presentations
Filter Changing Procedures For TEOM Series 1400ab and Model 8500 FDMS (B & C Types)
Advertisements

Build Your Own Future RC2 Serviceability. Build Your Own Future Safety and Ground Rules Before servicing, always remove A/C power from the unit and disconnect.
Zebra® 105SL™ * Removing and Installing Printhead
Canon 6000 series When taking cartridge out of the printer, make sure to seal the ink outlet with Scotch tape before refilling the ink. Step 1 Step 2 Make.
CHAPTER 45 Engine Lubrication.
Replacing the Maintenance Kit HP Printers OIT lab services.
H.E. Anderson Company Maintenance Tip How to Replace a Chemical Side Diaphragm This presentation will show you how to change a chemical side diaphragm.
Brio 2000 / Brio 2000-M E-Learning Service Manual Rev. 0.0.
Changing the Oil in a 2006 Mitsubishi Eclipse. Introduction Changing the oil in your 2006 Mitsubishi Eclipse is easier than you may think. With a few.
Troubleshooting Guide. Table of Contents 2 Shower Filter 3 Leak Between Top Housing & Filter4 Leak Between Swivel Collar & Housing5 Leak at Top of Swivel.
ZIPP 404 BEARING REPLACMENT GUIDE Tools Needed:
©Task Force Tips, Inc 2004 Task Force Tips Handline Upgrade Program Upgrade Brings Any Old Style Nozzle Up to Current NFPA Compliance Upgrade Adds a New.
Automatic Lubrication Products
Yamaha oil pump rebuild
¾”-2”. Modification Overview  Production of the series began in 1989 and is current.  Early models of ¾”-2” series did not always.
Step-by-step assembly instructions
Unit Test Calibration Training
Milling Machine Setups
Blackwood Fire Company Stihl Chainsaw Maintenance.
1 USDOC41 Rev 0 1/04 Training and Education Program ©2004 HemoCue, Inc. HemoCue ® Training and Education Program The HemoCue Hb System.
Copyright 2008 Kenneth M. Chipps Ph.D. How to Terminate a Corning Unicam Connector Last Update
DR-2000 Customer Benefits Security; Tamper resistant programming protects your customer and you! Low maintenance, long battery life & long squeeze tube.
860 (LF), 880 ½”- 2” 860 (LF), 880 ½”- 2”. Modification Overview  Production of the ½ - 2” 860 series began in 1997 and is current.  The 880 is an “N”
1 Zebra 170 XiIII Plus Removing and Installing Printhead Calibrating Head Resistance Print Quality Adjustments.
Hydraulic Digger Step-by-step assembly instructions (c) 2013 Mechanical Kits Ltd.1.
Clean Air Box Usage & Care CABs RAMs CO Monitors.
1 InnoSys Quick Connect End Effecter Service and Maintenance Procedures Nov. 19, 2007 Rev. B.
AquaGlo Water Detector Kit For Detecting Water in Jet Fuel
Powered Air-Purifying PARTICLE Respirator (PAPR) Copyright © 2013 by The S.E.A. Group.
Control Panel Overview Key pad: A Qwerty Keypad, used to enter an address. Programmable Features: The programmable features allow you to program.
Using the Unity 98 Cordless Response System Directions : Courtesy of IHC public relations.
Powered Air-Purifying Respirator (PAPR) Copyright © 2015 by The S.E.A. Group.
AccuMax Multi-Point Injection Mechanics
After Receiving this error code, Follow these steps to correct the problem… Click for next slide.
Tru Count Air Clutch Maintenance
Lubricus – settings and changes LUB-B-1 LUB-B-2 LUB-V-1 LUB-V-2 Grützner GmbH – Kohlenhofstr. 60 – Nürnberg Lubricus Schmiersystem –
© 2011 Pearson Education, Inc. All Rights Reserved Automotive Technology, Fifth Edition James Halderman IN-VEHICLE ENGINE SERVICE 27.
Domina PLUS B WORKING DIAGRAMS TROUBLESHOOTING INTERNAL VIEWS WIRING DIAGRAMS INSTALLATION 03 PREVIOUS MODEL.
The most common problem is for a mouthpiece to get stuck. Try not to use force to remove. Try gripping the mouthpiece and turning the instrument. We have.
Removing and Replacing the Battery Cover 1. Ensure the phone is turned off. 2. Press the Battery cover locker; lift the battery cover up and away from.
Optical Manufacturing Solutions 1 FOLLOW THE DIRECTIONS BELOW AFTER INSTALLING A NEW CUTTER BODY WITH POLISHING WHEELS INTO THE 7E TYPE MACHINES. IT IS.
Exacta ™ Digital Torque Wrenches Sturtevant Richmont Global Reach. Local Support.
PARKING BRAKE OPERATION, DIAGNOSIS, AND SERVICE
825, 825Y, 825YD 21/2”-10”. Modification Overview  825- ( ) Cast iron body- Threaded in seats- Internal check parts are epoxy coated iron. Old.
975, 975XL ¾”-2” 975, 975XL ¾”-2”. Modification Overview  Production of the original 975 began in This version had buna-n check discs and did not.
SIP POU cooler Installation Guide. Getting Started The SIP 2000 can be easily installed in most POU coolers in just a few minutes. The tools needed are.
994 2½ ”- 10”. Modification Overview  Production for the 994 began in 1999 and is current.
Flex Cam – Training This shows one version of a complete FlexCam system including Power Unit HCP and Compact Cam CC for piercing operation.
Clearing Procedures. DISASSEMBLY Major Groups Barrel Group Turn the cover latch and raise the cover group Grasp the retracting slide handle with the.
375, 375XL ¾”-1”. Modification Overview  Production of the ¾”-1” 375 began in 2004 and is current.  The lead free version 375XL was introduced in 2010.
ACCU-CHEK Inform II Operator Training
CLM Maintenance. Covers : 1 - Side cover, 2 - Back cover, 3 Top cover, 4 - Lamp door, 5 - Side cover input and communication side, 6 - HEPA dust filter,
1 InnoSys Quick Connect End Effecter Service and Maintenance Procedures Shreveport Assembly 14 MAY, 2008.
½”-10”. Modification Overview  Production of the series began in 1989 and is current.
009 (M3) ½”-2” 009 (M3) ½”-2”. Modification Overview- 009  009 ¾-1” ( ) (1” ) ¾-1” ( ) (1” ) 1¼ -2” ( ) 1¼.
Smart Board Troubleshooting.  The User Guide contains useful information such as installing, connecting, maintaining, and troubleshooting your Smart.
IMPLEMENTATION LOCATION VARIABLE AXIS LUBE VARIABLE SPINDLE LUBE PARAMETERS ELECTRICAL SERVICE MINIMAL LUBE SYSTEM.
Get Easy Battery Replacement Guide at Battfix.com
Basics of Medical Equipment Lecture 5
Shaft Replacement Standard Operating Procedure
IN-VEHICLE ENGINE SERVICE
Automatic Lubrication Products
Service Procedure For Changing Engine Oil And An Oil Filter
009 2½”-3”.
Call to Fix Canon Pixma MX340 printer Error 5200
Simple Way to Install Auto Lock Door in Car
Recyclable Replacement Service Pack Contents
CHAPTER 45 Engine Lubrication.
¾”-2”.
4000B (M3) ½”-2”.
Presentation transcript:

Recyclable Replacement Service Pack Contents Batteries Grease pouch prefilled Waterproof cover Technolube Electromechanical Refillable Lubricators * * * * * * * * * Plus replacement grease type label. Main Unit Replacing the used grease pouch and battery pack. Next.. ** ** For the MS (Synchronized w/Power) units replacement battery not included or required.

Technolube Electromechanical Refillable Lubricators * * * * * * * * *. Replacing the used grease pouch and battery pack. Order service packs from your distributor, with the grease pouches pre-filled with your choice of lubricant. The pack also includes a replacement battery, waterproof cover and new grease label. (The battery should be replaced for each new grease pouch as the old battery does not have enough power remaining for a second dispense period.) Procedure: Unscrew the housing and then the empty grease pouch. Remove old battery and replace with the new one, pressing down firmly. The used pouch and battery can be recycled. Next..

Technolube Electromechanical Refillable Lubricators * * * * * * * * * One very important step – check the hole in the centre of the base for proper setup. The check valve beneath the hole in the centre of the unit base has been improved by making it deeper in the most recent production. As the valve no longer protrudes into the grease pouch it is important to squeeze out grease until it is slightly above the tip of the grease pouch as shown below, to fill any space above the valve and eliminate an air bubble. If the check valve in your unit appears to protrude as in the picture below, please go to the next slide for instructions Now reassemble the unit with the new pouch. Press and hold the TEST button to activate a test cycle before resetting and replacing the unit on its location. RESETTING INSTRUCTIONS AFTER THE NEXT SLIDE.. So please be sure to screw the grease pouch down firmly but do not over-tighten. If you strip the thread on the pouch air can enter more easily. New and older style check valves Grease pouch ready to assemble

Technolube Electromechanical Refillable Lubricators * * * * * * * * * For the older style checkvalve, one very important step – ALWAYS ensure that there is no air bubble in the unit. When you remove the grease pouch from the unit, the pressure release often causes air to be drawn into the greaseway forming an air bubble. Unless removed this will stop the grease In the newly installed pouch from travelling into the bearing. There is a check valve beneath the hole in the centre of the unit base to deal with this. After removing the pouch, gently depress the check valve as illustrated a few times with a thin Allen wrench or screwdriver, or similar tool. This will remove any air which has been suctioned in. Wipe away any grease and reassemble the unit with the new pouch. Press and hold the TEST button to activate a test cycle before resetting and replacing the unit on its location. RESETTING INSTRUCTIONS NEXT.. Check valve location Tool inserted

Technolube Electromechanical Refillable Lubricators * * * * * * * * * month s After you have confirmed active dispensing, press RESET to stop, clean off the excess grease from the outlet, and check the bearing for any solidified grease. Fill the bearing to entrypoint with the same grease if necessary. Re-install the lubricator. If the lock icon appears on the display deactivate by pressing MODE LOCK until it disappears, and resume setup. The MODE LOCK will protect your setting from accidental change after a few seconds. Fix the grease label in place and replace the new clear plastic cover and you are done! Next.. Reset button Press POWER for two seconds If you have the 125cc or 250cc unit, press the “125/250/TEST” button until the display shows the correct capacity for your lubricator. Reset the dispensing rate by pressing the MODE LOCK until you reach the required month number. See setup chart below.

Technolube Electromechanical Refillable Lubricators * * * * * * * * * Your lubricator is now programmed and running. The setting is locked against accidental change, the display is giving you confirmation of your settings, and the time left is being displayed in days. These are the tests and procedures we use when assembling your initial refillable Mechanical Lubricator purchased “ready to set up” on arrival. The display unit may later flash various codes; charts with the message translations are on our flyers for the Mechanical series, and on our website. If you need more information, please get in touch with us by phone or . Technolube Inc. Richmond BC V7A 3K5 Canada Ph – tollfree Fax – tollfree “We strive to exceed your expectations”