Stopped Muon/Pion Measurements Jim Miller, BU May 2012 UW Test Beam Meeting.

Slides:



Advertisements
Similar presentations
NUCP 2371 Radiation Measurements II
Advertisements

Gamma-Ray Spectra _ + The photomultiplier records the (UV) light emitted during electronic recombination in the scintillator. Therefore, the spectrum collected.
GEANT4 Simulations of TIGRESS
X-Ray Astronomy Lab X-rays Why look for X-rays? –High temperatures –Atomic lines –Non-thermal processes X-ray detectors X-ray telescopes The Lab.
Basic Principles of X-ray Source Detection Or Who Stole All Our Photons?.....
M. Carson, University of Sheffield, UKDMC ILIAS-Valencia-April Gamma backgrounds, shielding and veto performance for dark matter detectors M. Carson,
A Muon Veto for the Ultra-Cold Neutron Asymmetry Experiment Vince Bagnulo LANL Symposium 2006 Outline ● UCNA Experiment ● Muon background ● Proposed Veto.
M. Carson, University of Sheffield IDM 2004, University of Edinburgh Veto performance for a large xenon detector.
Pair Spectrometer Design Optimization Pair Spectrometer Design Optimization A. Somov, Jefferson Lab GlueX Collaboration Meeting September
Hall D Photon Beam Simulation and Rates Part 1: photon beam line Part 2: tagger Richard Jones, University of Connecticut Hall D Beam Line and Tagger Review.
More phenomena difficult to observe A MacKinnon. More phenomena difficult to observe synchrotron radiation of positrons: sub-mm observations? inner bremsstrahlung.
LBL Comet-Mu2E Workshop January 24, 2009 Mu-e Conversion Backgrounds and Sensitivities– from proposal to measurement Doug Bryman "Wishing does not make.
Neutral Particles. Neutrons Neutrons are like neutral protons. –Mass is 1% larger –Interacts strongly Neutral charge complicates detection Neutron lifetime.
Lecture 2-Building a Detector George K. Parks Space Sciences Laboratory UC Berkeley, Berkeley, CA.
Gamma Spectroscopy HPT TVAN Technical Training
Ion Beam Analysis of Gold Flecks in a Foam Lattice F E Gauntlett, A S Clough Physics Department, University of Surrey, Guildford, GU2 7XH, UK.
experimental platform
Radiation therapy is based on the exposure of malign tumor cells to significant but well localized doses of radiation to destroy the tumor cells. The.
Stopping Power The linear stopping power S for charged particles in a given absorber is simply defined as the differential energy loss for that particle.
© JP 1  alpha e-e-  beta  gamma Marie Curie Antoine-Henri Becquerel (1852 – 1908) α,  and  RADIATION.
NEEP 541 Radiation Interactions Fall 2003 Jake Blanchard.
HYP03 Future Hypernuclear Program at Jlab Hall C Satoshi N. Nakamura Tohoku University 18 th Oct 2003, JLab.
Ivan Logashenko for Mu2e Collaboration
Status of the Beamline Simulation A.Somov Jefferson Lab Collaboration Meeting, May 11, 2010.
The Production of Cold Antihydrogen w. A Brief History of Antimatter In 1928, Paul Dirac proposes antimatter with his work in relativistic quantum mechanics.
SHMS Optics and Background Studies Tanja Horn Hall C Summer Meeting 5 August 2008.
Nuclear Forensics: Neutron Activation & Radiography
Study of the Halo Nucleus 6 He using the 6 Li(   ) 6 He Reaction Derek Branford - Edinburgh University for the A2-Collaboration MAMI-B Mainz.
GERMANIUM GAMMA -RAY DETECTORS BY BAYAN YOUSEF JARADAT Phys.641 Nuclear Physics 1 First Semester 2010/2011 PROF. NIDAL ERSHAIDAT.
Setup for hypernuclear gamma-ray spectroscopy at J-PARC K.Shirotori Tohoku Univ. Japan for the Hyperball-J collaboration J-PARC E13 hypernuclear  -ray.
Background from the NIST test The pencil neutron beam (1 mm 2 ) with intensity about 7000 n/sec The beam was completely absorbed in the beam stop with.
SNS2 Workshop August 28-29, 2003 Richard Talaga, Argonne1 Calibration of the OMNIS-LPC Supernova Neutrino Detector Outline –OMNIS Experiment and Detectors.
M. Aoki Translation of slides in 2010 JPS meeting (Okayama) By K. Shimomura and M. Aoki M. Aoki A , T. Ebihara A , N. Kawamura , Y. Kuno A , P. Strasser.
HPS Beamline: Background Rates, Sensitivity to Field Uncertainties M. Ungaro1HPS Collaboration Meeting, JLAB, May Concrete Wall thickness Study.
Measurements of the (n,xn) reactions cross sections using new digital methods. Habib Karam Group GRACE.
Accelerator Physics, JU, First Semester, (Saed Dababneh). 1 Principles of Spectrometry.
Artificial Radioactivity
Stopped Muon/Pion Measurements Jim Miller, BU May 2012 UW Test Beam Meeting.
RAL Muon Beam Line Properties. ISIS 70 MeV H- injection Ring accelerates up to 800 MeV in about 10 ms 50 Hz cycle - Dual Harmonic System ~ 2 x 1.5 MHz;
Neutron detection in LHe ( HMI run 2004) R.Golub, E. Korobkina, J. Zou M. Hayden, G. Archibold J. Boissevain, W.S.Wilburn C. Gould.
Beam test possibilities at JINR and Fermilab V. Pronskikh Fermilab 02/15/2012.
Chapter 5 Interactions of Ionizing Radiation. Ionization The process by which a neutral atom acquires a positive or a negative charge Directly ionizing.
Nov Beam Catcher in KOPIO (H. Mikata Kaon mini worksyop1 Beam Catcher in the KOPIO experiment Hideki Morii (Kyoto Univ.) for the KOPIO.
Physics Colloquium Ⅱ Shibata Laboratory OKA, Hiroki Nucleosyntheses studied with a Van de Graaff Accelerator [Contents] 1. Objective.
Development of a Segmented Planar Germanium Imaging Detector
COMET and DeeMe. Mu-e conversion search at J-PARC COMET Target sensitivity 10 C.L. using aluminum target – SINDRUM II 7x – MEG 2.4x
Giovanni Onorato Fermilab University of Rome “Guglielmo Marconi” INFN Lecce Mu2e general presentation.
Recent Studies on ILC BDS and MERIT S. Striganov APD meeting, January 24.
00 Cooler CSB Direct or Extra Photons in d+d  0 Andrew Bacher for the CSB Cooler Collaboration ECT Trento, June 2005.
1 Beam Extinction and Monitoring at the Upcoming Mu2e Experiment Ryan J. Hooper on behalf of the Mu2e Collaboration DPF 2015 August 5th, 2015.
B. Azadegan, S. A. Mahdipour Hakim Sabzevari University
Mu to e Meeting BNL, June 2006 Extinction requirement relaxation (Kevin O’Sullivan) Stopping Target Geometry (Cenap Ozben, David Morse) Yannis Semertzidis.
Radiation study of the TPC electronics Georgios Tsiledakis, GSI.
1 Giuseppe G. Daquino 26 th January 2005 SoFTware Development for Experiments Group Physics Department, CERN Background radiation studies using Geant4.
1 Peter Kammel Mu2e Test Run at PSI July 09 n Purpose of short presentation Run coordination Update to full collaboration and potential input n Structure.
The physics of Mu2e Bertrand Echenard California Institute of Technology Mu2e computing review doc-db XXXXX.
Present status of production target and Room design Takashi Hashimoto, IBS/RISP 2015, February.
The Mu2e Experiment at Fermilab Jim Miller Boston University for the Mu2e Collaboration.
Muon Rare Decay at PRISM Masaharu Aoki Osaka University KEKNP01 December 10-12, 2001, KEK.
N_TOF EAR-1 Simulations The “γ-flash” A. Tsinganis (CERN/NTUA), C. Guerrero (CERN), V. Vlachoudis (CERN) n_TOF Annual Collaboration Meeting Lisbon, December.
AlCap Analysis Discussion Analysis Steps  Protons: BG, response, unfolding Question: perform alternative fast signal analysis  Muons: BG, efficiency.
K2K and JHF-nu muon monitor Jun Kameda (KEK) 1. K2K muon monitor 2. JHF-ν muon monitor 3. Summary International workshop on Neutrino Beam Instrumentation,
Test of Hybrid Target at KEKB LINAC
at TSL high energy neutron facility
K2K and JHF-nu muon monitor
Neutronics Studies for the Nab Experiment
PARTICLE FLUX CALCULATION-III
Neutron Detection with MoNA LISA
Gamma-ray Spectroscopy technique is commonly used in Planetary Exploration Missions.
CLIC luminosity monitoring/re-tuning using beamstrahlung ?
Presentation transcript:

Stopped Muon/Pion Measurements Jim Miller, BU May 2012 UW Test Beam Meeting

Possible Measurements with Stopped Muons and Pions For beam normalization: Collect muonic, pionic xray data in singles mode – Ideally muons and pions are done separately in pure beams – How serious is background from electrons/positrons in beam? – Run rate up artificially with a radioactive source to test performance of Ge at high rates Look at activation gammas following mu and pi capture as alternative to xrays for normalization; run beam for a while with known total number of stopped muons to calibrate – Pi activation could confuse us but there are far fewer stopped pi’s than stopped mu’s – Other sources of excited Al? e.g. e?

Examples of muonic x ray spectra 3 F.J.Hartman, et al. Z. Phys. A 305, 189 (1982) J. Miller - Director's CD-1 Review Magnesium Lyman Series Aluminum Balmer Series

Physics Requirements- Xray Monitor 4 J. Miller - Director's CD-1 Review On the choice of detector type Excellent energy resolution (~ a few keV) Sufficiently large photopeak efficiency (>50%) Ability to tolerate background particles including neutrons and low energy photons Handle potentially high count rates, especially at injection time  n-type intrinsic germanium detector with a fast reset preamp (size > 45cm 3, depth > 3cm) On the location of the detector The detector should only view the target. – good collimation ahead of the detector. Far from the stopping target due to the large xray production rate ~10 10 Hz, the detector must be far from the source, Path from target: low attenuation of xrays A sweeper magnet should be used to eliminate charged particles The detector must be lie beyond the DS magnetic field and enclosure where it can be serviced periodically and annealed to repair neutron damage.

Location of stopping target monitor R. Ray - Director's CD-1 Review5

6 Conceptual Design J. Miller - Director's CD-1 Review The Muon Stopping Target Monitor is placed along the axis of the Detector Solenoid, at the downstream end of the end cap steel. End cap shielding Permanent magnet dipole Ge detector 1 mm thick SS window

Conceptual Design 7 J. Miller - Director's CD-1 Review

Conceptual Design 8 J. Miller - Director's CD-1 Review Selected specs: Photopeak efficiency at 1.33 MeV = 50% Resolution = 2.2 keV (FWHM) at 1.33 MeV Count rate = up to 10 6 /s at 1 MeV An example of commercially available Ge detector Ortec GMX HPGe detector GMX50P4 with X-cooler II mechanical cooler and a ultra-high count rate preamplifier option

Estimated Rates Muon stopping rate ~ 1x10 10 Hz 2p-1s xray production rate ~0.8x p-1s xray detection rate in photopeak, assuming 50% photopeak efficiency, 80% through 2p-1s: 1x10 10 x 0.5(photopeak efficiency)x2.8x10 -6 (geometric acceptance)x0.8(BR of 2p-1s)=11000 Hz Estimate of neutron damage: anneal every 1-3 months R. Ray - Director's CD-1 Review9

Other Measurements Other alternatives to xray stopping monitor for flux monitoring – Look at high energy photons from radiative DIO (RDIO) of stopped muons (flux drops fast above 53 MeV), also similar photon spectrum from bremsstrahlung in target following regular DIO [BR 1.4%] – Look at flux of photons from RMC (BR quite low but may have higher flux than gammas from RDIO at high energies). – Neutrons from stopped muons Could high-E neutrons be used to monitor muon capture rate? Neutrons, Protons from muon capture 70 MeV positrons from Calibration photons(need thin converter to make e+-e-) from – Use e.g. Lithium borate, see how clean the 129 MeV peak is.

Contaminated Targets Oxygen has a higher endpoint energy than either Al or Ti, therefore the DIO’s can create background With Oxidized targets of Al and Ti, measure relative number of xrays and hence relative number of muons stopped in O compared to Al or Ti (e.g. Al 2 O 3, … )

Comment We should select one or two measurements for the TRIUMF run