Regional Technical Forum July 8, 2002 Ken Anderson, NW Energy Efficiency Alliance Business Computer Energy Savings EZConserve’s Surveyor Software.

Slides:



Advertisements
Similar presentations
Northwest Power and Conservation Council Draft Deemed Measures for Commercial Lighting Retrofit Regional Technical Forum March 8, 2005.
Advertisements

Introduction Build and impact metric data provided by the SGIG recipients convey the type and extent of technology deployment, as well as its effect on.
Portable Classroom Controls Project Chuck Collins RCM Meeting April 27, 2007.
“Update on the Expansion of CSU’s Underground Electric System” Selection of a Street Light Monitoring System Presented by : Timothy R. Crabb, P.E. Assistant.
Home Area Networks …Expect More Mohan Wanchoo Jasmine Systems, Inc.
DISPUTES & INVESTIGATIONS ECONOMICS FINANCIAL ADVISORY MANAGEMENT CONSULTING Guidelines for Energy Efficiency Measure Cost and Non-Energy Benefits Subcommittee.
1 Retail Plug Load Portfolio (RPP) Work Paper Abstract Briefing for California Technical Forum Steve Blanc, Engineering Services Brian Smith, Evaluation,
D EEMED M EASURE U PDATES June 1, 2011 Regional Technical Forum Presented by: Bob Tingleff SBW Consulting, Inc.
BOA Electrical. E L E C T R I C A L Outline F Computers and printers F Appliances F Demand and consumption F ENERGY STAR ratings F Car plugs F Miscellaneous.
MVP House in Montana Energy Savings and Costs March 2 nd, 2009 Regional Technical Forum 1.
Deeming Savings for Ductless Heat Pumps in Manufactured Homes Regional Technical Forum January 4 th, 2011.
Review Tabled Agenda Item: Additional M&V Data on Ag Pump VFD Projects Determination of M&V requirements and/or deemed savings Regional Technical Forum.
PRJ566: Project Planning and Management
VRF for the Seventh Plan Preliminary Approach and Data for a Variable Refrigerant Flow Measure for the Seventh Plan Regional Technical Forum January 21,
Grocery Measure: LEDs for Reach-In Display Cases Regional Technical Forum July 21 st, 2015 Mohit Singh-Chhabra.
Power and Energy. Power Power means work over a time period Units = Watts Electric power is measured in Watts.
LED Case Lighting With and Without Motion Sensors Michele Friedrich – Sr. Engineer PECI 1/5/2010.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Savings of Specialty CFLs and LED Downlights Danielle Gidding Bonneville Power Administration.
Comprehensive IT Consulting Services an innovative approach to business.
BPA Pre-Pilot, Monmouth  14 homes with installed DHP, single zone, single compressor.  11 Monmouth, 2 Moses Lake, 1 Tacoma  Savings.
22 April 2004Energy Star Conference1 of 27 EC ENERGY STAR ® The Way Forward Conference Frankfurt 22 April 2004.
Northwest Power and Conservation Council Deemed Energy Savings and Cost-Effectiveness of 80-Plus Power Supplies RTF January 2007.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Commercial Kitchen Cooking Measures Convection Ovens, Combination Ovens, Dishwashers.
IntelliCon ™ Product Line Manufactured by Intellidyne, LLC Distributed by: IMC.
Plans to bring Out-of-Compliance UES Measures back into Compliance: 1. Agricultural Irrigation Hardware UES 2. Agricultural Motors UES Regional Technical.
Northwest Power and Conservation Council 6 th Plan Conservation Resource Supply Curve Workshop on Data & Assumption Overview of Council Resource Analysis.
Energy Free Stock Tanks Review of Existing Deemed Savings Regional Technical Forum July 7, 2009.
Non-Residential Network Computer Power Management UES Measure Update Regional Technical Forum July 16, 2013.
B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Residential LED Recessed Down light Fixtures RTF January 4, 2011.
NYS Forum IT Greening Workgroup Thin Client Devices DHCR Experience with Virtual Desktops June 12, 2010.
IT Greening Computer Power Consumption Study Christian Grieco Time Warner Cable
Grocery Measure: EC Motors for Display Cases Regional Technical Forum July 21 st, 2015 Mohit Singh-Chhabra.
Grocery Measure: EC Motors for Display Cases Regional Technical Forum June 16 th, 2015 Mohit Singh-Chhabra.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Residential Appliance Measure Updates Danielle Gidding Bonneville Power Administration.
Northwest Power Planning Council Fixing the Plumbing An Assessment of PNW Irrigated Agriculture Conservation Resource Potential July 1, 2003.
Residential Single Family and Manufactured Home Heat Pump Water Heaters Christian Douglass Regional Technical Forum 4/14/2015.
Networked Computer Power Management Software Determining “Equivalency” to Surveyor RTF Meeting February 5, 2008.
Deemed Savings Update: ECMs in Display Cases Ben Cartwright PECI January 5, 2009.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump RTF Sub-Committee February 22, 2012 Mira Vowles, P.E., CEM.
Network PC Power Management RTF May 4, Network PC Power Management What it is –Control of a networked computer's advanced energy management systems.
N ETWORK PC P OWER M ANAGEMENT June 28, 2011 Regional Technical Forum Presented by: Bob Tingleff SBW Consulting, Inc.
SEEM Calibration: Phase II Single Family Heating Energy Regional Technical Forum September 17, 2013 Presented By: Josh Rushton and Adam Hadley Subcommittee.
1 Distribution Efficiency Conservation Voltage Regulation (CVR) Jillianne Welker 4/21/2009.
Schools Lighting Hours of Use Data Regional Technical Forum May 13, 2014.
1 Management Information Systems NYC Human Resources Administration Richard Siemer – Deputy Commissioner MIS.
Rudan ltd. For efficient energy management. Our Vision With efficient management and application of new technologies, to become a leading company in the.
Of moderated conference calls on energy efficiency Utility Brown Bag Series BPA’s Rooftop Unit Service Pilot Jan 29, to 2 p.m. (PST) Facilitator:
Northwest Power and Conservation Council 1 Distribution System Efficiency Potential & Conservation Voltage Reduction Power Committee April 2009.
Proposed Deemed Savings Rates for Energy Star 3.0 Plus 30% Televisions By Christina Steinhoff June 1,
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump RTF Sub-Committee July 24, 2013 Mira Vowles, P.E., CEM Emerging.
Ductless Heat Pumps (DHP) in Single Family Homes with Zonal Electric Heat Proven UES Measure Proposal Regional Technical Forum October 16, 2013.
GrocerSmart TM Energy Modeling Software -Revision Status Report- & -Request For Input- July 13, 2010.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Information-Technology RTF Sub-Committee July 2, 2013 Mira Vowles, P.E., CEM Emerging.
Network PC Management Slides for RTF March 1, 2011.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Information-Technology RTF Sub-Committee May 7, 2013 Mira Vowles, P.E., CEM Emerging.
PNW RoofTop Unit Working Group - RTUG – RTU Savings Research Project Phase 3 December 15, 2009.
Week 13 Introduction to compiling an energy efficiency audit report and Writing the utility analysis section.
Experience you can trust. Californial Industrial Energy Efficiency Potential CALMAC/MAESTRO Meeting San Francisco, CA July 27, 2006 Fred Coito
Computer System Support   The costs of installing, operating and maintaining computer systems are called total costs o ownership or TCO  TCO includes.
ENERGY STAR Commercial Refrigerators and Freezers Regional Technical Forum January 21 st, 2016 Mohit Singh-Chhabra.
D EEMED M EASURE U PDATES May 3, 2011 Regional Technical Forum Presented by: Bob Tingleff SBW Consulting, Inc.
Non-Residential Network Computer Power Management Christian Douglass Regional Technical Forum January 21, 2016.
LED Traffic Signals Review of Existing Deemed Measures Regional Technical Forum August 4 th, 2009.
Regional Telecommunications Workshop on FMRANS 2015 Presentation.
A complete solution…..
07 December 2011 Faronics UK Green IT Survey. Would you consider yourselves to be a 'green' organisation in terms of IT efficiency?
1 Energy Efficiency Opportunities Bubble Chart Background.
U.S. Energy Information Administration Independent Statistics & Analysis US. Energy Information Administration Cornell University April 4,
Behavior Modification Report with Peak Reduction Component
DO NOW Copy down your homework: 2-4 Lesson Check on page 105
Presentation transcript:

Regional Technical Forum July 8, 2002 Ken Anderson, NW Energy Efficiency Alliance Business Computer Energy Savings EZConserve’s Surveyor Software

Introductions can be tricky

Team Approach  EZConserve Inc. (  Energy Efficiency Company  Software Background  Problem Solving  Quantec, LLC (  Evaluation Contractor  Survey Customers and Team Members  Field Verify Software Performance & Energy Savings

EZConserve’s First Problem  In 1999 US Businesses used 74 TWh/year of Electricity for Office and Network Equipment  25 to 30 TWh/year for Personal Computers and Displays (Monitors)  If 100% of PCs used Energy Star Power Management and night shut-off, save 12 TWh/year in the US  PNW is 5% of the US--Technical potential savings of 0.6 TWh/year or 68 aMW  Current Alliance project is going after 450,000 units for 9.3 aMW by 2010 in PNW region

Surveyor Software Solution  Company-wide power management and remote shut-down for PCs & Displays on a business network  Cost is $10 to $15 per PC depending on volume plus $5 in- house labor for installation, test, and activation  Non-Energy Benefits  Automation eliminates manual reminders and shut-down  IT administrator selects client PCs to shut-down  Night security from hacking  Isolate PCs from virus attack and power outage  Free tool to push other software to client PCs  Monitor the adoption of energy profiles  Automated real-time reports on energy savings and PC usage

Energy Savings Methodology Development  Previous studies  Lawrence Berkeley National Labs (LBNL)  Kawamoto 2001  Roberson 2002  Arthur D. Little  Roth 2002  (Summarized other LBNL studies including Webber 2001 which looked at usage patterns of 1,280 computers and 1,458 displays in 11 offices in California and Washington DC)

UEC Unit Energy Consumption Equation (kWh/year)  UEC = (SPM X (PA X HA + PL X HL + PO X HO) / 7) X 365 /  ((1 – SPM) X PA X (HA + HL) +PO X HO) / 7) X 365 / 1000  where  PA= Average active ON power (Watts)  PL= Average low-power PM (Watts)  PO= Average off power OFF (Watts)  HA= Hours active (hours/week)  HL= Hours low-power (hours/week)  HO= Hours off (hours/week)  SPM= Power-management-enabled rate for computer or monitor (%)

Current/Baseline Values for Key Variables ComputerMonitorReference  PA 7065Watts(Roberson-2002-Draft)  PL 9 5Watts(Roberson-2002-Draft)  PO 3 1Watts(Roberson-2002-Draft)  HA Hours/week(Roth-2002)  HL Hours/week(Roth-2002)  HO Hours/week(Roth-2002)  SPM 25%60%(Kawamoto-2001)

Surveyor Inputs  InputsPAPLPOHAHLHOSPM  Max, 168 ON Hours %  %  No Energy Star %  %  Current Baseline %  %  Surveyor %  %  50 ON, Current SPM %  %  50 ON, 85% SPM %  %

Surveyor Savings

Surveyor Savings Compared to Competitor Claims  USDOE/EPA test of EZSave for monitors only  DOE’s Office of Energy Efficiency and Renewable Energy  312 monitors  SPM 32% to 95%, After 3 months SPM=85%  Typical savings suggested at 200 kWh/year monitor only  WattSavvy by Blue Owl Technologies  LADWP provides it to residential customers free by web-site  PC and monitor savings suggested at 300 kWh/year

Proposal  Propose that the RTF recommend to BPA that they deem the energy savings of the EZConserve Surveyor software product at 200 kWh/year per PC/Display combination ( SPB = 2 $0.05/kWh and $20 per PC)  Propose that the RTF recommend to BPA that the RTF review the Alliance’s final evaluation results of EZConserve Surveyor (due first quarter 2003) and that the deemed savings be revised as necessary at that time.